Techly I-ALARM-KPAD User manual

Wireless
Keypad
www.techly.com EN

2
This keypad enables you to arm and disarm your alarm
system, or arm it in Home Mode.
Before entering your home, all you need to do is type
your passcode and press the Disarm button [ ], or swipe
the RFID tag (sold separately) in front of RFID reader to
disarm the system.
Box Content
Keypad X 1
AAA 1.5V batteries X 3
Screws x 4
User’s manual

3
Appearance
LED Indicator
Arm/Unlock
Disarm
Home Mode /
Unlock
SOS key
RFID reader*
*RFID tag (125 KHZ) sold separately.
The keypad supports up to 50 RFID tags.
Refer the instructions on page 9 of this
manual to learn how to register and
RFID tag in the keypad.

4
Rear cover
Battery compartment
Tamper switch

5
Preparation Before Use
How to turn the keypad on
The keypad is powered by 3 AAA batteries. Before using
for the rst time, remove the battery strip.
1. Unscrew and open the case.
2. Insert the batteries according to the positive and
negative signs.
3. Close the case and screw it back.
Remark
Because of the tamper switch, opening the rear cover of
the keypad when the latter is on triggers the alarm. In
such case, stop the alarm by disarming the system, as
explained in page 10 of this manual.

6
Installation
1. Unscrew the case and open it.
2. Screw the rear cover to a door frame or to a wall.
3. Fasten the front cover of the keypad to the real cover
and screw them together.
Remark
Because of the tamper switch, opening the rear cover of
the keypad when the latter is on triggers the alarm. In
such case, stop the alarm by disarming the system, as
explained in page 10 of this manual.

7
Setup
The keypad operates under 4 modes.
Normal mode
The LED indicator blinks once every 5 seconds.
Sleep mode
Under Normal mode, the keypad switches to sleep mode if
no operation is made for 35 seconds. Press the Arm [ ] or
Home Mode [ ] keys to exit Sleep mode. When the keypad
is in sleep mode, the LED indicator is o.
RFID Reader mode
Under Normal mode, press [*] on the keypad to activate
the RFID reader for 10 seconds: the LED indicator turns
on. After 10 seconds, the LED light turns o as the
RFID reader turns o automatically.
Setup mode
To enter Setup mode, switch to Normal mode and then
enter [your admin code+#] on the keypad. The LED in-
dicator blinks once every second. Press [*] to exit the
Setup mode and switch to the Normal mode. After 30
seconds without operation, the keypad goes back to the
Normal mode.
Default admin code: 123456
Remark
Correct operation: 1 beep and the LED light blinks once.
Wrong operation: 2 beeps and LED light blinks twice.

8
Register the keypad in the control panel
Make sure the control panel is in Connection mode (re-
fer to the user’s manual of your alarm system)
Press Arm [ ] or Home Mode [ ]
on the keypad to unlock it.
Type your usercode or admin
code on the keypad, and then
press any of the Arm [ ], Dis-
arm [ ] or Home Mode [ ]
keys. Your hear short beeps: the
registration has succeeded.
Default admin code: 123456. Defaut user code: 1234
The control panel of your alarm system can be con-
trolled from distance on the keypad once the latter has
been registered in the control panel.
Connect the keypad to a siren
The keypad can be connected to an indoor or outdoor
siren, which enables you to trigger the siren by pressing
the [SOS] key on your keypad.
To connect the keypad to a siren, set the wireless siren
to Connection Mode (refer to the manual of your siren if
necessary). Press the Arm [ ] or Home Mode [ ] key on
the keypad to switch to Normal Mode. Then type [your
admin code or user code] and press any of the Arm [ ],
Disarm [ ] or Home Mode [ ] keys on the keypad.

9
Register an RFID tag in the keypad
1. Press Arm [ ] or Home Mode
[] on the keypad to unlock it.
Then type [admin code + #] to
enter Setup Mode.
Default admin code: 123456
If you hear 2 beeps, the code you have typed is wrong.
2. Type [41#]. You hear one
beep and the LED indicator
lights up: the keypad switches
to Connection Mode.
3. Swipe the RFID tag in front
of the RFID reader. You hear
one beep: the connection is
successful.
lf you hear two
beeps, the RFID tags has
already been connected.
Press [*] to exit Setup Mode.
To clear all registred RFID tags, press any of the Arm [ ]
or Home Mode [ ] keys on the keypad to unlock it, and
then type [admin code + #42#]. You hear one beep: the
RFID tags have been deleted from the keypad.

10
Usage
The keypad can be used as a remote control. Your user
code or your admin code will be required before arming
or disarming the system, or switching to Home Mode or
Mute Mode.
Arm the system
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Type your user code or admin code.
3. Press the Arm key [ ].The LED indica-
tor blinks once, the keypad beeps once
and sends to the control panel the sig-
nal to arm the system.
When the alarm panel receives the signal, the siren beeps
once and the Arm indicator on the control panel lights up: the
alarm system is now armed.
Default admin code: 123456, default user code: 1234
Disarming the system with the keypad
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Type your user code or admin code.
3. Press the Disarm button [ ]: the LED
indicator blinks once, the keypad beeps
once and sends to the control panel the
signal to disarm the system.
When the alarm panel receives the signal, the siren
beeps twice and the Disarm indicator lights up: the
alarm system is now disarmed.

11
Disarming by RFID tag
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Press [*] to activate the RFID reader
for 10 seconds.
3. Within the next 10 seconds, swipe
the RFID tag in front of the reader to
disarm the system.
The RFID reader turns o when a RFID tag is swiped in
front of it, when the key [*] is pressed again on the key-
pad, or after 10 seconds without operation.
Home Mode
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Type your user code or admin code.
3. Press the [ ] key: the LED indicator
blinks once, the keypad beeps once and
sends the signal to the control panel to
switch to Home Mode.
When the alarm panel receives the signal, the siren
beeps once and the Home Mode indicator lights up: the
alarm system is now in Home Mode.
All the sensors in regular zones are armed except those
in the Home Mode zone. The sensors in the Home Mode
zone are disarmed so that users can move inside their
home.

12
Emergency call
Refer to the instructions page 14 of this manual for
more information on how to lock/unlock the SOS button.
With SOS button unlocked
1. Press Arm [ ] or Home Mode [ ]
on the keypad to unlock it.
2. Press [SOS].
3. The LED indicator blinks once,
the keypad beeps once, and the
alarm is triggered immediately.
With SOS button locked
1. Press Arm [ ] or Home Mode [ ] on the keypad to un-
lock it.
2. Type your user code or admin code.
3. Press [SOS] to trigger the alarm immediately.
Low battery indication
When the battery level is low, the LED indicator blinks 3
times every 5 seconds. In such case please change the
batteries.

13
Setting
Enter Setup mode
Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
Type [admin code+#] to enter Setup
mode.
Default admin code: 123456
Under setup mode, if no operation is made for 30 seconds
the keypad will exit the setup mode automatically. The
Setup mode can also be exited by pressing [*].
Exit delay
Detectors start detecting potential intrusions imme-
diately after the system has been armed. To prevent
alarms when you leave your house, an exit delay can be
set up. If you have set up an exit delay, the control panel
will receive the signal to arm the system when you press
the Arm key [ ] on the keypad after the time set.
1. Enter Setup mode.
2. Type [33+delay time in seconds+#].
3. You hear one beep: the setus is
successful.
To deactivate the Exit delay, set 0 as
delay time.
Remark
The time is set in seconds, it can be set from 0 to 255.
Default setting: 0.

14
If the exit delay has been set, the control panel will beep
once every second after having pressed the Arm [ ] key.
The rhythm of the beeps will speed up during the last 15
seconds. After the exit delay time has elapsed, the con-
trol panel is armed. If an exit delay has been set up for
both the control panel and the keypad, the actual delay
time will be the combination of both exit delays.
This setting does not apply to the Home Mode.
Remark
Only the Exit delay can be set on the keypad. The Entry
delay can be set on the control panel (refer to the user
manual of your alarm system).
Lock / Unlock the SOS button
Lock the SOS button
1. Enter Setup mode.
2. Type [3410#].
3. Your hear one beep: the Setup is
successful.
If the SOS button is locked, you will
need to press Arm [ ] (or Home Mode
[]) to unlock the keypad, to type
your admin or user code, then to press
[SOS] to trigger the alarm.
Unlock the SOS button
1. Entet Setup mode.
2. Type [3411#].
3. You hear one beep: the setup is
successful.
If the SOS button is unlocked, the
control panel ring out immediately
when you press Arm [ ] (or Home
Mode [ ]) and then [SOS].
Remark
Default setting: SOS button is locked.

15
Keyboard clicks
Keyboard clicks can be turned on or o. If keyboard
clicks are o, the successful setup notication sound
will be o too.
Turn keyboard clicks on
1. Enter Setup mode.
2. Type [3510#].
3. You hear one beep: the setup is
successful.
Turn keyboard clicks o
1. Enter Setup mode.
2. Type [3511#].
Remark
Default Setting: keyboard clicks are on.

16
Enable / Disable deactivation by RFID tag
Enable deactivation of the system by RFID tag
1. Enter Setup mode.
2. Type [3610#].
3. You head one beep: the setup is
successful.
Disable deactivation of the system by RFID tag
1. Enter setup mode.
2. Type [3611#].
3. You hear one beep: the setup is
successful.
Remark
Default setting: deactivation of the system by RFID tag
is enabled.

17
Change user code
The user code may be required to interact with the con-
trol panel (arm or disarm the system, or switch to Home
Mode). We recommend you to change the user code be-
fore using the keypad for the rst time.
1. Enter setup mode.
2. Type [38+new user code+#].
3. You hear one beep: the setup is
successful.
Remark
The user code must consist of 4 digits. Default user code
is “1234”.
Change admin code
The admin code may be required to change the settings
and interact with the control panel (arm or disarm the
system or switch to Home Mode). We recommend you
to change the admin code before using the keypad for
the rst time.
1. Enter setup mode.
2. Type [39+new user code+#].
3. You hear one beep: the setup is
successful.
Remark
The admin code must consist of 6 digits. Default admin
code is “123456”.

18
Reset
After having reset the keypad, the user code, the admin
code, and other settings will be restored to default set-
tings.The RFID tags that have been registered will not be
deleted from the keypad.
1. Enter Setup mode.
2. Type [987654321#].
3. You hear one beep: the setup is suc-
cessful.
FAQ
Low battery Change the battery
No response from the
keypad
The batteries‘
positive and negative
terminals are
reversed.
Remove and insert
the batteries again
according to the
instructions in this
manual.
The keypad is locked
Press Arm or Home
Mode on the keypad
to unlock it.
The keypad cannot
be registered to the
control panel
No response from the
alarm panel
Make sure the alarm
panel is on.
Make sure the alarm
panel is in Connection
Mode.

19
No response from the
control panel when
operating on the
keypad
The keypad is not
registered in the
control panel.
Register the keypad
in the control panel
by following the
instructions in this
manual.
The keypad is
installed too far from
the control panel.
Install the keypad
and the control panel
closer to each other.
It is recommended
to buy a repeater
to expand the
transmission distance.
Cannot disarm the
system by RFID tag.
The RFID tags have
not been registered in
the keypad.
Register the RFID tag
in the control panel
according to the
instructions in this
manual.
The RFID reader is
disabled.
Enter Setup mode and
activate the function
"Enable/Disable
deactivation by RFID
tag".
The keypad is locked.
Press Arm or Home
Mode then [*] before
disarming.
The keypad cannot be
set up.
The keypad is not
unlocked.
Refer to instructions
in this manual.
The keypad does not
switch to Setup mode.
Refer to instructions
in this manual.
The keypad cannot
arm, disarm or switch
to Home Mode.
Your user code or
admin code has not
been typed before
each operation.
Type your user code
or admin code before
operation.

20
Care and Maintenance
For a safer use and a longer lifetime of the keypad, we
recommend you to follow the instruction listed below.
Usage notices
• This keypad must be registered in the control panel
of your alarm system before being used for the rst
time.
• The power supply of this keypad may aect transmis-
sion distance of the wireless signal.
• The keypad is powered by 3 x AAA batteries.
• Remove the battery strip before using for the rst
time.
• Do not press the SOS key on the remote control if it is
unnecessary to avoid disturbing neighborhood.
• Check the system regularly to make sure the system
works properly.
• The keypad is neither waterproof nor moisture-proof,
install it in a shady, cool and dry place.
• The case of this keypad is made of ABS plastic. Keep
away from bright light for a longer lifespan.
• The keypad is not explosion-proof. Keep away from
re and ames.
• Dismantling of this product must be done by profes-
sional personnel only.
This manual suits for next models
1
Table of contents
Languages:
Popular Keypad manuals by other brands

Overhead door
Overhead door Universal Wireless Keypad user manual

FBII
FBII XL STAR 4500 owner's manual

DMP Electronics
DMP Electronics 9800 Series Installation and programming guide

Allen-Bradley
Allen-Bradley Poweflex 525 VFD Setting Procedure

BFT
BFT T-Box quick start guide

SDC
SDC EntryCheck 923P installation instructions

Savant
Savant WFB LV02 Series Quick reference guide

X-keys
X-keys XK-0991-UMAK24-R product manual

Comcast
Comcast Security Keypad quick start guide

Dinsafer
Dinsafer DKPD01A user manual

Digital Monitoring Products
Digital Monitoring Products Thinline 7070 Installation sheet

AMX
AMX Metreau DAS-MET-6SRC installation guide