technetix AIMA3000.FRAS/R Operational manual

May/2016 - Version 1.0
AIMA3000.FRAS/R
Optical Analogue Forward Receiver – Standard
Product User Manual

AIMA3000.FRAS Product User Manual
Technetix Group Limited
AIMA3000.FRAS/R
Analogue Forward Receiver - Standard
Product User Manual

AIMA3000.FRAS Product User Manual
Technetix Group Limited
Contents
1 About This Manual....................................................................................................................................................5
1.1 Related Documentation........................................................................................................................................................................5
1.2 Document Conventions........................................................................................................................................................................5
1.3 Technical Support...................................................................................................................................................................................6
2 Precautions.................................................................................................................................................................7
3 Overview.....................................................................................................................................................................8
3.1 FRAS Overview .......................................................................................................................................................................................8
3.1.1 Product Description ..................................................................................................................................................8
3.1.2 Product Key Features...................................................................................................................................................................8
3.1.3 Specifications..................................................................................................................................................................................9
3.1.4 Block Diagram ................................................................................................................................................................................11
3.1.5 Order Details...................................................................................................................................................................................12
3.2 FRAR Overview .......................................................................................................................................................................................13
3.2.1 Product description.......................................................................................................................................................................13
3.2.2 Key features.....................................................................................................................................................................................13
3.2.3 Specifications..................................................................................................................................................................................14
3.2.4 Block Diagram ................................................................................................................................................................................16
3.2.5 Order Details...................................................................................................................................................................................17
4 Module Characteristics ............................................................................................................................................18
4.1 Module Appearance and Port Layout..............................................................................................................................................18
4.1.1 Overview ..........................................................................................................................................................................................18
4.1.2 Front Panel Layout ........................................................................................................................................................................19
4.1.3 Rear Panel Layout..........................................................................................................................................................................21
5 Installation ..................................................................................................................................................................22
5.1 Preparatory Work for Installation .......................................................................................................................................................22
5.2 Unpacking.................................................................................................................................................................................................22
5.3 Module Installation .................................................................................................................................................................................23
5.4 Connecting Optical Cables .................................................................................................................................................................24

AIMA3000.FRAS Product User Manual
Technetix Group Limited
5.4.1 Using the Sliding Fibre Guide....................................................................................................................................................24
5.4.2 Using the Fibre Tray......................................................................................................................................................................27
5.4.3 Cleaning the Fibre Connector Ends and Front-panel Optical Ports .............................................................................29
5.4.4 Connecting the Optical Fibres ..................................................................................................................................................30
5.5 Redundancy Connection (for FRAR only)........................................................................................................................................30
5.6 Check Module LEDs..............................................................................................................................................................................31
5.7 Test the Optical Input Signal ...............................................................................................................................................................32
5.8 Test the RF Output Signal ....................................................................................................................................................................32
6 Module Configuration & Alarms .............................................................................................................................33
6.1 Port Configuration screen....................................................................................................................................................................33
6.2 Restore Factory Defaults......................................................................................................................................................................37
6.3 Reboot........................................................................................................................................................................................................39
6.4 Alarms Monitoring ..................................................................................................................................................................................40
6.4.1 Alarm Status Page .........................................................................................................................................................................40
6.4.2 Module Operating Voltage and Temperature Alarm..........................................................................................................41
6.4.3 Module Port Alarms.......................................................................................................................................................................42
6.4.4 Alarm Monitoring Configuration................................................................................................................................................43
6.4.5 Input/ Output Status Monitoring................................................................................................................................................44
6.5 Logs Management..................................................................................................................................................................................45
6.6 Device Upgrade......................................................................................................................................................................................46
6.7 Redundancy Configuration and Alarms (for FRAR only).............................................................................................................47
7 Troubleshooting.........................................................................................................................................................49
7.1 Indicator for determining faults ..........................................................................................................................................................49
8 Declaration of Conformity .......................................................................................................................................50

AIMA3000.FRAS Product User Manual
Technetix Group Limited
1 About This Manual
1.1 Related Documentation
The following documents may be used in conjunction with this manual:
• Technetix.AIMA3000 - Product User Manual
• Technetix.AIMA ASMM - Product User Manual
• AIMA3000 NMS Web Management System Product User Manual
- Technetix.NMS3-EPSM - Basic Inventory Management
- Technetix.NMS3-EPSM - Basic Alarm Management
- Technetix.NMS3-EPSM - Basic System Management
- Technetix.NMS3-EPSM - Basic Template Management
1.2 Document Conventions
Before you use the manual, please familiarise yourself with the format used in this manual.
‘*’ Asterisk: Points marked with an asterisk means there is a corresponding note on the page

AIMA3000.FRAS Product User Manual
Technetix Group Limited
1.3 Technical Support
If you need help in the process of setting up and maintaining an FRAS-R, please contact Technetix’s technical
support sta:
Europe:
Technetix BV
Kazemat 5
NL-3905 NR Veenendaal
P.O. Box 385
NL-3900 AJ Veenendaal
The Netherlands
Phone: +31 318 58 59 59
Email: customer.service.[email protected]

AIMA3000.FRAS Product User Manual
Technetix Group Limited
2 Precautions
WARNING!
This equipment is intended for indoor applications. To prevent fire or electrical shock, or
damage to the equipment, do not expose units to water or moisture.
• You should carefully read and thoroughly understand the contents of the manual before
installing and using this equipment.
• A typical connector is the SC/APC 8°. Note: An 8 ° angle polished optical connectors must
be used.
• At any time, there may be dangerous voltage inside the device.
• Do not power up before the cover and the panels of the equipment are installed and the
enclosure is closed.
Cleaning
Only use a damp cloth for cleaning the front panel. Use a soft dry cloth to clean the top of the unit.
DO NOT use any spray cleaners or chemicals of any kind.
Outage or overload requiring service and repairs
Unplug the unit and refer the servicing to Technetix qualified service personnel only.
Servicing and repairs
DO NOT attempt to service this unit yourself. Refer all servicing needs to Technetix qualified service
personnel only.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3 Overview
3.1 FRAS Overview
3.1.1 Product Description
The Analogue Forward Path Receiver - Standard (FRAS) is designed to plug into Technetix latest generation Advanced
Intelligent Multi-services Access platform - the AIMA3000.
The FRAS is available in single and dual port configurations. It incorporates a low noise front-end circuit that receives
optical wavelengths from 1260 nm to 1620 nm and converts them into RF signals for Master Antenna Television (MATV),
CATV, and broadband applications. The supported RF bandwidth is from 45 to 1000 MHz.
The module oers a superior frequency response with a low distortion profile and low noise characteristics.
The FRAS optical receiver module features automatic gain control (AGC), which is based on broadband detection or
through optional pilot signal detection.
The RF output AGC threshold level and the slope can be managed remotely.
3.2 Product Key Features
• Plug-and-play with the AIMA3000 platform
• Superior performance with a low noise profile and minimal distortion characteristics
• High RF output for flexible deployment
• Supports Automatic Gain Control (AGC) for a stable RF output
• Electronic slope control
• Electronic gain setting and AGC adjustable thresholds
• Broadband GaAs amplifier technology
• Support for CENELEC and NTSC standards up to 110 channels (analogueueue and digital)
• Comprehensive status monitoring and alarm with Technetix NMS network management software
• HMS compliant
• Remote firmware upgrade and auto upload/download of configuration files through ASMM web interface or
using Technetix NMSE
• Bulk firmware updates through Technetix NMSE
• FCC, CE and RCM(1) compliant
(1) See Declaration of Conformity for current status.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.3 Specifications
Optical Performance
Optical wavelength 1260 ~ 1620 nm
Optical input -5 ~ +3 dBm
Optical return lose > 60 dB
Optical connector SC / APC (1), FC / APC, LC / APC, E2000 / APC
RF Performance
RF bandwidth 45 ~ 1000 MHz
RF output level (2) 40 dBmV
RF flatness ± 0.75 dB
Gain adjustment 0 ~ 20 dB
Slope adjustment 0 ~ 7 dB
ACG range (input variation) 10 dB
AGC accuracy ± 0.5 dB over AGC range
RF impedance 75 Ω
RF return loss > 16 dB
RF test point relative to RF output port -20 ± 1 dB
RF OUT connector GSK-type female
RF test points Mini-SMB
Alarms and status Front-panel LEDs, SNMP traps
Notes:
(1) Standard option. Contact a Technetix Sales Representative for availability of other options
(2) Measured in a typical system with 0 dBm optical input, 3% ~ 4 % OMI, and dBuV=60+dBmV.
Link Performance (3)
CNR > 53 dB
CSO > 65 dB
CTB > 70 dB

AIMA3000.FRAS Product User Manual
Technetix Group Limited
General
Power supply Powered via AIMA3000 backplane
Power consumption < 8 W
Operating temperature -5 ~ +55 °C
Operating humidity 90 % (Non-condensing)
Storage temperature -25 ~ +70 °C
Storage humidity 90 % (Non-condensing)
Dimensions (W*D*H) 24.6 * 410 * 152.5 mm
Weight 0.88 kg
Network management Technetix NMSE or through ASMM’s Web Interface
Notes:
(3) Loaded with 77 NTSC channels, measured with Technetix referenced optical transmitter, 0 dBm, 3%~4% OMI.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.1.4 Block Diagram
Table 3-1 FT5P Block Diagram Glossary
Figure 3-1 FRAS Block Diagram
Parameters Glossary
OPTICAL INPUT Optical Input Port
PRE AMPLIFIER Pre-Amplifier
ATTENUATOR Pre-Attenuator
MID AMPLIFIER Mid-stage amplifier
SLOPE Slope Control
OUTPUT STAGE Post-Amplifier
RF OUTPUT RF Output Port
RF TEST -20 dB -20 dB RF Output Test Port
RF DETECTOR RF Sensor
BIAS Bias Voltage Measurement
CPU Micro-processor
TO BACKPLANE AND COMMS Module power and communication interface
MODULE POWER SUPPLIES Supply Bus

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.5 Order Details
A-FRAS-[X]-[Y]-[Z] Analogue Forward Receiver – Standard
Options:
X Optical Input Ports
S Single (1)
Y Optical Connector Type
S SC/APC *
F FC/APC
L LC/APC
E E2000/APC
Z Bandwidth
1G 45 ~ 1000 MHz (Standard)
* Standard option. Contact a Technetix Sales Representative for availability of other options.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.2 FRAR Overview
3.2.1 Product description
The Analogue Forward Receiver - Redundant (FRAR) is designed to plug into Technetix latest generation Advanced
Intelligent Multi-services Access platform - the AIMA3000.
The FRAR is available in single port configurations. It incorporates a low noise front-end circuit that receives optical
wavelengths from 1260 nm to 1620 nm and converts them into RF signals for Master Antenna Television (MATV), CATV, and
broadband applications. The supported RF bandwidth is from 45 to 1218 MHz.
The module oers a superior frequency response with a low distortion profile and low noise characteristics.
The FRAR optical receiver module features automatic gain control (AGC), which is based on broadband detection.
The RF output AGC threshold level and the slope can be managed remotely.
3.2.2 Key features
• DOCSIS 3.1 compatible with operating bandwidth up to 1218 MHz
• Plug-and-play with the AIMA3000 platform
• Superior performance with a low noise profile and minimal distortion characteristics
• High RF output for flexible deployment
• Supports Automatic Gain Control (AGC) for a stable RF output
• Electronic slope control
• Electronic gain setting and AGC adjustable thresholds
• Broadband GaAs amplifier technology
• Support for CENELEC and NTSC standards up to 110 channels (analogue and digital)
• Comprehensive status monitoring and alarm with Technetix NMS network management software
• SCTE-HMS MIB compliant
• Remote firmware upgrade and auto upload/download of configuration files through ASMM web interface or
using Technetix NMSE
• Bulk firmware updates through Technetix NMSE
• Fully FCC, CE, and RCM compliant

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.2.3 Specifications
Optical Performance
Optical wavelength 1260 ~ 1620 nm
Optical input -10 ~ +3 dBm
Optical return lose > 55 dB
Optical connector SC / APC (1), FC / APC, LC / APC, E2000 / APC
RF Performance
RF bandwidth 45 ~ 1218 MHz
RF output level (2) 41 dBmV
RF flatness ± 0.5 dB
Gain adjustment 0 ~ 20 dB
Slope adjustment 0 ~ 7 dB
ACG range (input variation) 10 dB
AGC accuracy ± 0.5 dB over AGC range
RF impedance 75 Ω
RF return loss > 18 dB
RF test point relative to RF output port -20 ± 1 dB
RF OUT connector GSK-type female
RF test points Mini-SMB
Alarms and status Front-panel LEDs, SNMP traps
Redundant switching time Typical: <30 ms
Link Performance
NTSC (4) CENELEC(42ch) (5)
CNR > 52 dB > 52dB
CSO > 68 dB > 70 dB
CTB > 70 dB > 70 dB
General
Power supply Powered via AIMA3000 backplane
Power consumption < 12 W
Operating temperature -5 ~ +55 °C
Operating humidity 90 % (Non-condensing)
Storage temperature -40 ~ +70 °C
Storage humidity 90 % (Non-condensing)
Dimensions (W*D*H) 24.6 * 410 * 152.5 mm
Weight 0.88 kg
Network management Technetix NMSE or through ASMM’s Web Interface

AIMA3000.FRAS Product User Manual
Technetix Group Limited
Note:
(1) Standard option. Contact a Technetix Sales Representative for availability of other options.
(2) Measured in a typical system with 0 dBm optical input, 3%~4% OMI.
(3) dBuV=60+dBmV.
(4) Loaded with 77 NTSC channels, measured with Technetix referenced optical transmitter @ 0 dBm, 3% OMI.
(5) Loaded with 42 CENELEC channels, measured with Technetix referenced optical transmitter @ 0 dBm, 3% OMI.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.2.4 Block Diagram
Table 3-2 FRAS Block Diagram Glossary
Parameters Glossary
OPTICAL INPUT Optical Input Port
ATTENUATOR Pre-Attenuator
MID AMPLIFIER Mid-stage amplifier
SLOPE Slope Control
OUTPUT STAGE Post-Amplifier
RF OUTPUT RF Output Port
RF TEST -20 dB -20 dB RF Output Test Port
RF DETECTOR RF Sensor
BIAS Bias Voltage Measurement
CPU Micro-processor
TO BACKPLANE AND COMMS Module power and communication interface

AIMA3000.FRAS Product User Manual
Technetix Group Limited
3.2.5 Order Details
A-FRAR-[X]-[Y]-[Z] Analogue Forward Receiver – Redundant
Options:
X Optical Input Ports
S Single (1)
Y Optical Connector Type
S SC/APC *
F FC/APC
L LC/APC
E E2000/APC
Z Bandwidth
1G 45 ~ 1000 MHz (Standard)
12 45 ~ 1218 MHz (Standard)
* Standard option. Contact a Technetix Sales Representative for availability of other options.

AIMA3000.FRAS Product User Manual
Technetix Group Limited
4 Module Characteristics
4.1 Module Appearance and Port Layout
4.1.1 Overview
Front Panel
Rear Panel
Figure 4-1 Module Appearance

AIMA3000.FRAS Product User Manual
Technetix Group Limited
4.1.2 Front Panel Layout
Figure 4-2 FRAS Front Panel Layout

AIMA3000.FRAS Product User Manual
Technetix Group Limited
Table 4-1 FRAS Front Panel Functions
Item Number Item Description
1 MODE LED
Module gain control mode indicator
MGC: Green Light Blinking
AGC: Green
2 STATUS LED
Module working alarm indicator
Normal: Green
Minor Alarm: Orange
Major Alarm: Red
3 OPT IN LED
Optical input signal status indicator
ON: Green
Input signal slightly high/low: Orange
Input signal too high/low: Red
4 RF OUT LED
RF output signal status indicator
ON: Green
Output RF level slightly high/Low: Orange
Output RF level too high/low: Red
5 RF OUT TP RF output test port
6 Orange tab-retaining clip Used to plug and anchor the module. The orange tab-retaining clip will
pop-up after pressing the release and plug module.
7 OPT IN Optical forward signal input port
8 Mounting Screw Module fastening screw
Table of contents