Technotherm TPF-EcoRF User manual

FR Thermostat programmable radio
EN Wireless programmable thermostat
DE Programmierbarer Funkthermostat
NL Draadloos programmeerbare thermostaat

- 31 -- 31 -
EN
Contents
1. Installation............................................................................. 33
2. Description............................................................................ 34
3. Wireless association ............................................................ 35
4. Configuration ........................................................................ 36
CF01 - Correcting the temperature measured............................ 36
CF02 - Temperature displayed in AUTO mode........................... 37
CF04 - Control type .................................................................... 37
CF05 - Energy saving mode....................................................... 37
CF06 - ON/OFF button display in standby mode........................ 38
CF07 - Backlighting .................................................................... 38
CF08 - Opening detection function............................................. 38
CF09 - Presence detection function ........................................... 39
CF10 - Value of the max. comfort setting.................................... 39
CF11 - Programming format....................................................... 39
CF12 - Time display format ........................................................ 40
CF13 - Automatic change to summer/winter time ...................... 40
CF15 - Display of the symbol ............................................... 40
CF16 - Display of the symbol (heating request) ..................... 40
CF17 - Display of the symbol ............................................. 41
CF18 - Display of the consumption ............................................ 41
CF28 - Anticipation function ..................................................... 42
CF29 - Anticipation sensitivity settings....................................... 42
CF30 - Display of room temperature in shutdown mode ........... 42
5. Setting the clock ................................................................... 43

- 32 -- 32 -
Contents
6. Setting the temperatures (settings) .................................... 44
6.1 Defining the comfort setting.................................................. 44
6.2 Defining the Economy setting............................................... 44
6.3 Defining the Frost protection setting..................................... 44
6.4 Behavioural indicator............................................................ 45
7. Programming ........................................................................ 46
8. AUTO mode ........................................................................... 48
9. "Party" mode......................................................................... 49
10. Absence mode .................................................................... 50
11. External override ................................................................ 51
12. Anticipation......................................................................... 51
13. Information button.............................................................. 52
14. Locking access to the settings ......................................... 53
15. Off mode.............................................................................. 53
16. Return to initial settings.....................................................54
16.1 Automatic reset of parameters to factory setting ................ 54
16.2 Initialisation of all the parameters....................................... 55
17. Remove the wireless association...................................... 56
18. Changing the batteries....................................................... 57
19. Troubleshooting .................................................................. 57
20.Technical characteristics ................................................... 58

- 33 -- 33 -
EN
1. Installation
Place the thermostat:
- in the main room (e.g. living room/dining
room) or in the centre of your home,
- wall-mounted or placed on a piece of
accessible furniture at a height of 1.50 m
- away from heat sources (fireplaces,
sunlight) and draughts (windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact
with the outdoors or with an unheated room (e.g. garage, etc.).
Mini 20 cm
1
2
3
3
4
5
OR

- 34 -- 34 -
2. Description
❶AUTO mode
❷Comfort mode
❸Economy mode
❹Frost protection
mode
❺Date and time setting/
Programming
❶Time
❷Day
❸Temperature measured
or setting
❹Active setting
❺Wireless transmission
❻"Party" mode
❼Absence mode
❽Information
❾Shutdown mode
Temperature
setting
1
2
3
4
5
1
3
4
2
5
8 96 7
Standby mode:
The product switches to standby mode after a certain time
without any activity. Activate the product by pressing a button
or turning the selector knob

- 35 -- 35 -
EN
>5s
>3s
>5s
2
1
3
4
... ... ...
3. Wireless association
❶Set the receiver(s) to association
mode (refer to receiver guide),
❷The thermostat must be in
shutdown mode.
Press and hold the 2nd button from
the left for 5 seconds.
The screen displays the thermostat version.
❸Press and hold the 2nd button from
the left for 5 seconds again.
The screen displays the rF01 menu.
❹Press OK.
The thermostat searches for the receivers
to associate.
The number of receivers found and
associated is displayed in the centre of
the screen. Number of receivers

- 36 -- 36 -
4. Configuration
The thermostat must be in shutdown mode.
❶Press and hold the 2nd button from the left for 5 seconds.
The screen displays the thermostat version.
❷Press OK.
The screen displays the CF01 menu.
❸Choose your selection or setting with + and -.
Press OK to validate and go to the next setting.
To exit the mode, turn the selector knob
Note: the greyed out sections of the tables match the default
values
CF01 - Correcting the temperature measured
Can be set from -5°C to +5°C.
Example: the temperature displayed by the unit is 19°C and the
actual temperature (thermometer) is 20°C, set +1°C.
>5s
EXIT
-5°C -> +5°C
1 2
3
4

- 37 -- 37 -
EN
4. Configuration
>5s
EXIT
-5°C -> +5°C
1 2
3
4
CF02 - Temperature displayed in AUTO mode
CF04 - Control type
CF05 - Energy saving mode
0Temperature setting
1Temperature measured
0Chrono-proportional (PI) control
1 ON/OFF control
0Display switches off after 10 seconds if nothing is pressed
1 Display switches off between midnight and 5am
2 Display always on

- 38 -- 38 -
4. Configuration
CF06 - ON/OFF button display in standby mode
CF07 - Backlighting
CF08 - Opening detection function
If a door/window magnetic contact (e.g. window) is associated with
the receiver, the heating will switch to Frost protection when the
window is opened.
0Symbol not displayed in standby mode
1Symbol displayed in standby mode
0Disabled
1 Enabled (switches off after timer)
0Disabled
1 Enabled

- 39 -- 39 -
EN
4. Configuration
CF09 - Presence detection function
If a motion detector is associated with the receiver, the
temperature will be lowered automatically in the event of an
extended absence:
• 1.5 h -> Active setting -1.5°C
• 3.5 h -> Active setting -3.5°C
• 48 h -> Frost protection setting
CF10 - Value of the max. comfort setting
Can be set from 22°C to 30°C.
Default value: 28°C
CF11 - Programming format
0Disabled
1 Enabled
0Programming in 1 h steps
1 Programming in 1/2 h steps

- 40 -- 40 -
4. Configuration
CF12 - Time display format
CF13 - Automatic change to summer/winter time
If CF13 = 0, the date setting will not be proposed.
CF15 - Display of the symbol
If CF08 = 1:
CF16 - Display of the symbol (heating request)
012 (AM/PM)
1 24
0Disabled
1 Enabled
0Symbol always steady even for a presence detection
event
1 Symbol flashes if there is a presence detection event
0Symbol not displayed
1 Symbol displayed

- 41 -- 41 -
EN
4. Configuration
CF17 - Display of the symbol
CF18 - Display of the consumption
If the display of the consumption is enabled, specify the power of
the heating elements
0Symbol steady if there is a presence detection event
1 Symbol flashes if there is a presence detection event
0Disabled
1 Enabled
❶Select the heating element
❷Confirm with OK.
❸Specify its power in Watts.
❹Confirm with OK.
2 4

- 42 -- 42 -
4. Configuration
CF28 - Anticipation function
The anticipation function enables the required Comfort tempera-
ture to be obtained at the programmed time.
Press + or - to activate or deactivate.
Press OK to confirm. Change to the CF29 menu.
CF29 - Anticipation sensitivity settings
The slope setting depends on the heating system.
It is set between 1°C to 6°C (in increments of 0.1°C).
Default value: 3°C.
If the temperature is reached too early, reduce the value.
If the temperature is reached too late, increase the value.
Press + or - to set.
Press OK to confirm. Change to the CF30 menu.
CF30 - Display of room temperature in shutdown
mode
Press + or - to activate or deactivate.
Press OK to confirm and leave the setting mode.
0 Deactivated
1 Activated
0 Deactivated
1 Activated

- 43 -- 43 -
EN
5. Setting the clock
❶Turn the selector knob to PROG.
7
22300 5900
121
3
5
311
4
2015...
6
1
❷Enter the hour
and confirm with
OK.
❺Enter the month
and confirm with OK.
❸Enter the min-
utes and confirm
with OK.
❻Enter the year
and confirm with OK.
❹Enter the day
and confirm with
OK.
❼Turn the
selector knob
to AUTO to exit
the mode
The date setting cannot be
proposed (see CF13 configuration).

- 44 -- 44 -
6. Setting the temperatures (settings)
6.1 Defining the comfort setting
❶Turn the selector knob to .
❷Set the Comfort temperature
(5°C to max. Comfort).
Configuration CF10
❸Confirm with OK.
6.2 Defining the Economy setting
❶Turn the selector knob to .
❷Set the Economy temperature
(5°C to max. Comfort).
❸Confirm with OK.
6.3 Defining the
Frost protection setting
❶Turn the selector knob to .
❷Set the Frost protection
temperature (5°C to max. Comfort).
❸Confirm with OK.
If you remain in one of these modes, the thermostat will operate
permanently in relation to this setting (no programming)
13
5°C -> Confort max.
15°C -> +19°C
15°C -> +10°C
2
3
2
3
2

- 45 -- 45 -
EN
6. Setting the temperatures (settings)
13
5°C -> Confort max.
15°C -> +19°C
15°C -> +10°C
2
3
2
3
2
6.4 Behavioural indicator
When the settings are adjusted, depending on the thermostat
model, the colour of the screen changes or an indicator is dis-
played according to the selected temperature.
Green up to 19°C (reduced consumption)
Orange from19.5°C to 24°C (average consumption)
Red from 24.5°C to max. comfort (High consumption)
To benefit from this function, according to the thermostat
model, activate the backlighting function (CF05).
OR

- 46 -- 46 -
7. Programming
❶Turn the selector knob to PROG.
Upon activation, the programming for each day is a comfort period
from 6am to 11pm.
You can create your different Economy and Comfort periods using
the and buttons.
Example: Comfort from 6am to 8am and 5pm to 11pm
❷Press up
to 06:00
❸Press up to
08:00
❹Press up
to 17:00
Programming can be made by steps of 1 hour or 1/2 hour
(configuration menu CF11).
6h0h 24h23h8h 17h
2 3 4
5 6 7
7
1

- 47 -- 47 -
EN
7. Programming
6h0h 24h23h8h 17h
2 3 4
5 6 7
7
1
Start again for each day of the week.
Programmable
period
Setting assigned to
the period
❺Press
up to 23:00
❻Press up
to 00:00
❼Press OK to
validate and go to the
next day.
❼Pressing OK for 3
seconds confirms the pro-
gram and copies it over
to the next day (COPY
function).
Day

- 48 -- 48 -
8. AUTO mode
In AUTO mode, the thermostat follows
the programme of the day.
The symbol indicate a heating
request (configuration CF16).
The automatic programme can be
temporarily suspended by:
- a "Party Mode" override ( ),
- an Absence mode ( ),
- a window magnetic contact (symbol ),
if the function is activated (configuration CF08).
The heating then goes to Frost Protection.
- an absence detection (symbol off), if the function is
activated (configuration CF08).
The heating then goes to "lower":
• Absence 1.5 -> Active setting -1.5°C
• Absence 3.5 -> Active setting -3.5°C
• Absence 48 h -> Frost-protection
: Heating request
: Party mode
: Absence mode
: Temperature measured
: Outdoor temperature
: Door/window magnetic
contact active
: Presence detection
in progress
: External override
: Spent battery
: Radio transmission

- 49 -- 49 -
EN
The "Party" mode can temporarily suspend the
automatic programme by applying a temperature setting chosen
for a programmed duration (from 30 minutes to 12 hours).
5°C-> Confort max.
0h30-> 12h
1 2
3
4
❶From the AUTO mode
and press the button.
❸Set the required duration.
Confirm with OK.
❷Set the required tempera-
ture. Confirm with OK.
❹The countdown starts.
Return to AUTO mode and
its settings at the end of the
countdown by by pressing
C.
9. "Party" mode
Table of contents
Other Technotherm Thermostat manuals
Popular Thermostat manuals by other brands

Tech Controllers
Tech Controllers EU-R-12b user manual

Bryant
Bryant II TSTAT-0-20 Installation and start-up instructions

Robertshaw
Robertshaw RS3110 Specifications

Venstar
Venstar ColorTouch T5800 Owner's manual and installation instructions

Lennox
Lennox Merit 51M37 Operation manual

PSG
PSG HS-4024U Installation and operating instructions