TeichTip SunSun SuperEco JTP Series User manual

Operation Manual
SunSun SuperEco Filter Pump
JTP and JTP-R Series
51634–61645
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 2
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
The information contained in this document may be altered at any time without prior notice. Copying or
spreading any part of this document in any way without prior written permission is prohibited. All rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operation manual, including the diagrams and figures contained within.
Even though, the WilTec Wildanger Technik GmbH has undergone the utmost effort to ensure that this
operation manual is complete, faultless and up to date, mistakes cannot be entirely avoided. We are
looking forward to hearing from you in case of you finding any mistakes or wishing to submit suggestions
for improvement.
Send an e-mail to:
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us in advance
or to place your order via our webshop.
E-mail: service@wiltec.info
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15
To return orders for exchange, repair or for other purposes, please use the following address. Attention!
In order to allow for a smooth processing of your complaint or return, it is important to contact our cus-
tomer service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: [email protected]o
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 3
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients
take some basic safety precautions when using this product. Please read this operation manual
carefully and make sure you have understood its content.
Keep this operation manual safe and accessible at all times.
CAUTION:
On and near standing water, garden and swimming ponds, use of the unit is only permitted with a resid-
ual current circuit breaker with a tripping rated current of up to 30 mA (according to VDE 0100 parts 702
and 738).
The unit is not suitable for use in swimming pools, paddling pools of any kind and other water bodies in
which people may be present during operation. Operation of the unit with people being in the danger
zone is not permitted. Consult your electrician!
This device is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and/or knowledge, unless they have been given supervision
or instruction concerning use of the device by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the device.
ATTENTION:
•Perform a visual inspection of the device before each use. Do not use the device if safety de-
vices are damaged or worn. Never override safety devices.
•Only use the device in accordance with the intended use specified in these instructions for use.
•You are responsible for safety in the work area.
•If the power cord or electrical plug is damaged due to external influences, do not repair the cable
but replace it with a new one. This work may only be carried out by a qualified electrician.
•The voltage of 230 V AC indicated on the unit's rating plate must correspond to the existing
mains voltage.
•Never lift, transport or fasten the unit by the power cord.
•Make sure that the electrical plug connections are protected from moisture and flooding.
•Always disconnect the plug before working on the unit.
•Avoid exposing the unit to a direct jet of water or rain.
•The operator is responsible for compliance with local safety and installation regulations. Consult
a qualified electrician if necessary.
•The user must take suitable measures (e.g., installation of an alarm system, standby pump,
etc.) to prevent damage caused by flooding of rooms in the event of a malfunction of the unit.
•In the event of a failure of the unit, repair work may only be carried out by a qualified electrician.
•The unit must never run dry or be operated with the intake line completely closed.
•The unit must not be used for operating swimming pools.
•The unit must not be installed in the drinking water circuit.
WARNING:
Read all safety notices and instructions. Failure to comply with safety notices and instructions may
result in electric shock, fire and/or serious injury. Keep all safety notices and instructions for future ref-
erence.
Resistance
•The maximum temperature of the pumped liquid should not exceed +35 ℃in continuous oper-
ation.
•Avoid pumping aggressive liquids (of acids, alkalis, silo leachate, etc.) and liquids with abrasive
(rubbing-off) substances (e.g., sand).

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 4
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
Electrical connection
•The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse protection at least
6 A.
•The motor is protected against overloading or blocking by the built-in thermal motor protection.
In case of overheating, the overheating protection of the motor automatically switches off the
pump and after cooling down, the pump switches on again automatically.
Mains connection
The pond pump you have purchased is already equipped with a protective contact plug. The pump is
intended for connection to a 230 V~50 Hz earthed socket. Make sure that the socket is sufficiently fused
(min. 6 A) and in perfect condition. Insert the pump plug into the socket; the pump is then ready for
operation.
Notice:
Installation
Please position the pump under water and ensure that no water can get into the socket.
Features
New and clear design with variable frequency technology, low power consumption, high flow rate, large
capacity, good noise insulation, can be used in water and on land.
•Wear-resistant, rust-proof, and durable ceramic shaft
•Suitable for fresh and salt water as it contains no copper
•All components can be disassembled for easy cleaning.
•With stepped hose nozzle, suitable for connecting hoses with different diameters.
•Rotor blockage protection with immediate power cut-off in case of pump impeller blockage.
Technical data
Model
Item №
Power supply
Power (W)
Max. head (m)
Output (ℓ⁄h)
JTP-1800
51634
230 V/50 Hz
11
2.2
1800
JTP-2800
51635
18
3.0
2800
JTP-3800
51636
25
3.8
3800
JTP-4800
51637
32
4.5
4800
JTP-4000R
51638
25
3.2
4000
JTP-5000R
51639
30
3.6
5000
JTP-6000R
51640
40
4.0
6000
JTP-7000R
51641
50
4.4
7000
JTP-8000R
51642
60
4.8
8000
JTP-10000R
51643
80
6.0
10000
JTP-12000R
51644
100
6.5
12000
JTP-14000R
51645
120
7.0
14000

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 5
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
Note!
There are 2 types for connection to inlet and outlet:
Type 1:
1. Loosen the screw nut clockwise.
2. Connect the hose. 3.
3. Tighten the screw nut anticlockwise.
Type 2 (multi-stage connections):
1. Select the right size for the connection and cut off the smaller connections.
2. Connect the hose.

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 6
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
Explosion view, parts list, and operating instructions
JTP-1800-2800-3800-4800
No.
Designation
No.
Designation
1
Control valve
6
Bearing
2
Filter casing
7
Housing
3
Impeller cover
8
Rear cover
4
Rotor
9
Cable seal
5
O-sealing ring
10
Base plate
•Fig. 1: Set the flow rate using the rotary control.
•Fig. 2: Open the filter housing by turning it in the direction of the arrow and then pulling it off.
•Fig. 3: Move the snap lock on the base plate in the direction of the arrow.
•Fig. 4: Remove the base plate.
•Fig. 5: Turn the motor housing in the direction of the arrow and remove it.
•Fig. 6: Pull the impeller and pump shaft out of the housing to clean or replace them.
•Fig. 7: Make sure that the sealing ring is properly refitted before reassembling the pump.

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 7
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
JTP-4000R-5000R-6000R-7000R-10000R-12000R-14000R
No.
Designation
No.
Designation
1
Filter housing
6
Bearing
2
Control valve
7
Housing
3
Impeller cover
8
Back cover
4
Rotor
9
Base plate
5
O-sealing ring
•Fig. 1: Set the flow rate with the help of the control dial.
•Fig. 2: Open the filter housing by turning it in the direction of the arrow and then pulling it off.
•Fig. 3: Remove the control valve in the direction of the arrow.
•Fig. 4: Move the snap lock on the base plate in the direction of the arrow.
•Fig. 5: Loosen the base plate.
•Fig. 6: Turn the motor housing in the direction of the arrow and remove it.
•Fig. 7: Pull the impeller and the pump shaft out of the housing to clean or replace them.
•Fig. 8: Make sure that the sealing ring is properly refitted before reassembling the pump.

© by WilTec Wildanger Technik GmbH Item 51634–51645 Page 8
http://www.WilTec.de
http://www.aoyue.eu 10 2021-1
http://www.teichtip.de
Disposal regulations
EU guidelines regarding the disposal of scrap electric devices (WEEE, 2012/19/EU) were implemented
in the law related to electrical and electronic equipment and devices.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEE-
registration number DE45283704.
Disposal of used electrical and electronic devices (in-
tended for use in the countries of the European Union
and other European countries with a separate collec-
tion system for these devices).
The logo on the article or on its packaging points out
that this article must not be treated as normal house-
hold waste but must be disposed to a recycling collec-
tion point for electronic and electrical waste equipment.
By contributing to the correct disposal of this article you
protect the environment and the health of your fellow
men. Environment and health are threatened by inap-
propriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste
disposal facilities or the store where you purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this operation
manual require the written permission of WilTec Wildanger Technik GmbH.
This manual suits for next models
15
Table of contents
Other TeichTip Water Pump manuals
Popular Water Pump manuals by other brands

Rx Clear
Rx Clear Universal 701460 manual

Enerpac
Enerpac PUD-1100B instruction sheet

Ingersoll-Rand
Ingersoll-Rand 6737X-XXX Operator's manual

Becker
Becker VT 4.10 operating instructions

BRINKMANN PUMPS
BRINKMANN PUMPS SBC1520 operating instructions

Crane
Crane burks pumps WB4 Installation and operation manual

ATD Tools
ATD Tools ATD-5226 instruction manual

Clarke
Clarke CBP900 Operation & maintenance instructions

Graco
Graco Dura-Flo 7847 instructions

Agilent Technologies
Agilent Technologies 1100 Series user manual

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS S4A1-E25 460/3 Installation, operation and maintenance manual

Milton Roy
Milton Roy MILROYAL D instruction manual