Teknik SMARTBAY One Box User manual

APPROVED
VEET
IPART
APPROVED
[SMARTBAY]
“ONE BOX” LED HIGHBAY
USER MANUAL
Teknik Lighting Solutions Pty Ltd
ABN: 44 608 397 913
Tel: 1300 313 780
www.tekniklighting.com.au

INTRODUCTION
Thank you for selecting the [SMARTBAY] “One Box” LED Highbay. Please ensure that the luminaire
is installed in accordance with the below instructions. Teknik Lighting Solutions Pty Ltd assumes
no responsibility for inappropriate use or installation of the product, including any associated damage
caused.
1. Read the entire manual carefully prior to
installation and operation.
2. The warranty period is listed on the product as
well as on the packaging. Teknik will repair or
replace the product if it becomes defective under
normal use due to a manufacturing defect within
the prescribed period.
3. Declared lumen output is based upon
measurements obtained during operation on
the appointed LED electronic driver under
standardised laboratory conditions.
4. Installation must be performed by a licensed and
qualied electrician, in accordance with these
instructions and relevant Australian Standards.
5. Instant restart is allowed.
6. Do not change or tamper with any internal electric
circuits, add any wires, connectors or cables for
any reason.
7. Please do not insert any physical objects of any
nature into the tting as this may cause electric
shock, malfunction or damage to the products.
8. Before replacement of the tting turn the power o
and allow to cool down.
9. In case of weight discrepancy when replacing old
lamps, please ensure that the mounted structure
is rated to withstand the weight of the new lamp
and installation materials.
10. For further information, please contact Teknik
(www.tekniklighting.com.au) or your local
distributor.
PRECAUTION
\ 5 year warranty
\ 5 option wattage switchable functionality
\ Unique heat sink design to reduce dust
build up
\ Smart hook system for easy and quick
installation
\ Integrated motion and daylight sensor for
intelligent lighting control
www.tekniklighting.com.au

Hook Mount
Bracket Mount (Optional)
Note: Supplied safety lanyard should be used for all installation options.
INSTALLATION DIAGRAM
³150mm
³150mm
³500mm
CHAIN
(iron)
load capacity > 30kg
M8
b
a
9
6
6
42
120
9
e
c
d

DIMENSIONAL DRAWING
WATTAGE SWITCHABLE FUNCTION
60
21.45
6.80
Unit = mm
[SMARTBAY] “One Box” LED Highbay
[SMARTBAY] Microwave Motion Sensor
102
336
When sensor option is required, ensure sensor module is tted and use sensor option switches as below.
When non sensor option is required, ensure blanking module is tted and use non sensor switches as below.
ON
ON ON
ON ON
ON
80W
80W
SENSOR
NO SENSOR
120W 150W 175W
Sensor Version No Sensor Version
150W
200W
120W
175W
Sensor
Wattage
DIM
+12V
GND
OFF
OFF OFF
OFF OFF
OFF
1
11
1
1
1
1
22
2
2
2
2
33
3
3
3
3
44
4
4
4
4
2

SENSOR INFORMATION
SENSOR DEFAULT SETTINGS
SENSOR INSTRUCTIONS
ab
Silica gel soft
Product Type Microwave Motion Sensor
Operating Voltage 12VDC/55mA
HF System 5.8GHz CW radar
Detection Angle 30o~ 50o
Power Consumption <1W
Detection Range (DXH) Max 16x12m
Hold Time 30s ~ 30min
Daylight Sensor 2 ~ 500Lux; Disable
Stand-by Period 0s, 10s ~ 1h, +∞
Stand-by Dimming Level 10% ~ 50%
Mounting Indoors, ceiling & wall mounted
Working Temperature -20 ~ +60oC
Model HS-SEN Microwave/constant illumination
HS-SEN-RF Microwave/constant illumination + RF (868MHz)
Detection Range (DXH) 100%
Hold Time 20mins
Daylight Sensor 500Lux
Stand-by Period +∞
Stand-by Dimming Level 30%
Note: When sensor option is not required, replace sensor module with supplied blanking module

SECTION 1: TYPICAL APPLICATIONS
The [SMARTBAY] turns on at full or dims to
maintain the lux level. The light output regulates
according to level of natural light available
HF MOTION DETECTOR
Daylight Harvesting
When the ambient light is below the selected daylight threshold lux level, The [SMARTBAY] will adjust its output
to maintain that selected level. If no motion is detected for the selected hold time, the [SMARTBAY] will dim to
the selected standby dimming level. If no motion is detected during the standby time, the [SMARTBAY] will
switch to power saver mode (10% light output).
The [SMARTBAY] will remain in power saver
mode (10% light output) if the ambient light level
is above the daylight threshold.
When no movement is detected after the
selected hold time, light will dim to the selected
standby level.
When the ambient light level is below the
selected daylight threshold the [SMARTBAY]
will automatically adjust light output to meet
selected daylight threshold level.
The [SMARTBAY] will enter power saver
mode (10% light output) when no motion is
detected during the selected standby time.

SECTION 2: REMOTE CONTROL (OPTIONAL)
DETECTION PATTERN
3
6
9
12
15
1 2 3 41235476
2
2 4 64
68
8
2468 10 12 14 16 18 20
857 68
height (m)
height (m)
high sensitivity area low sensitivity area
Ceiling mounting (m )W all mounting (m)
Note: the red LED indicator flash one time when RC
receives signal successfully
1
3
7
9
6
8
10
11
13
14
12
2
4
5
HS-REM
&
A
4hh
4
h
Permanent ON/OFF[ button ]
Press button ,to select permanent ON or permanent OFF mode.
1
1
* Press button / to resume automatic operation.
The mode will change to AUTO Mode after power failure or circuit power is cycled (via switch or breaker)
2 4
Note: "Off" activates power saver mode (10% light output)
Note: the red LED indicator will flash once when
RC receives signal successfully
high sensitivity area low sensitivity area
Ceiling mounting (m) Wall mounting (m)


Short press “Learn/Erase” button on RC to activate pairing mode, and the
receiver unit will flash once every second for 3min.
Note: the unit can only pair up to 30 units.
Step
1
The receiver unit (slave unit)
Red LED indicator is on for 3min
Short press “Learn
/Erase” button
Step3
The receiver unit (slave unit)
Red LED indicatoron in on
Erase:
Long press “Learn/Erase” button for 3s to the sensor unit. The red LED indicator
rapidly flash for about 5s. all commands it has received before will be erased.
Step2
The commander unit (master unit)
The red LED indicator flash one time.
The red LED indicator flash rapidly
when RF signal is received
Short press “Transmit” button on RC, the commander unit (master unit) will
flash one time to send the transmission signal.
Upon receiving the transmission signal, the receiver unit (slave unit) will
rapidly flash 3 times in 1s to indicate the success of pairing. Repeat this step
to pair more units. One more short press on “Learn/Erase” button to the
receiver unit to complete the pairing process, the receiver unit will quit the
pairing mode.
Note:
Press button RX100%, the light on receiver unit is 100% on upon receiving
RF on signal; Press “RX STBY%” button, the light(s) goes to preset stand-by
dimming level directly.`
The receiver unit (slave unit)
Short press “Transmit”
button
Short press “Transmit”
button
RF GROUPING
MALFUNCTION CAUSE REMEDY CAUSE REMEDY
The fixture does not light up
The fixture is always on
The fixture is on when it should not Adjust zone, change installation site
Incorrect daylight threshold setting
Continous movement in the detection zone
Sudden change in temperature due to weather (wind,
rain, snow) or air expelled from fans, or open windows
Faulty fixture
No power supply
Adjust daylight threshold setting
Replace fixture
Check power to sensor
Check detection area setting
SECTION 3: TROUBLESHOOTING
1. Minimum distance from luminaire to any ammable object is 2m.
2. In case of weight discrepancy when replacing old lamps, please ensure that the mounting structure is rated to
withstand the weight of the new lamp and installation materials.
3. For further information, please contact Teknik (www.tekniklighting.com.au) or your local distributors.
NOTES

www.tekniklighting.com.au
DISCLAIMERS
1. This product must be installed and used as per these instructions.
2. This product contains no serviceable parts and no attempt should be made to repair this product. If the
product is faulty it should be discarded.
3. This product is not suitable for installation in hazardous and/or corrosive areas.
4. Electrical installations periodically receive transient over voltages. This product has been designed to minimise
the eect of such voltages on connected equipment. It may not give full protection for extreme over-voltage
transients such as those resulting from a close lightning strike.
5. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such
intellectual property remains the property of Teknik Lighting Solutions Pty Ltd in all cases.
6. This product has been designed to operate in ambient temperatures -40oC to + 50oC.
Table of contents
Other Teknik Floodlight manuals