VX1410 IntelliFrameEnhanced Monitor Upgrade Kit 3
Installation Instructions
These instructions assume a certain familiarity with the instrument. If you need
further details, refer to the VX1410 IntelliFrame Instruction Manual. For
assistance to install this kit, please call your nearest Tektronix, Inc., Service
Center or Tektronix Factory Service.
CAUTION. Many components within this instrument are extremely susceptible to
static-discharge damage. Service the instrument only in a static-free environ-
ment. Observe standard handling precautions for static-sensitive devices while
installing this kit. Always wear a grounded wrist and foot strap while installing
this kit.
Installing the Enhanced Monitor Board (Option 1M)
Before you install the Enhanced Monitor Board, you need to remove the fan
assembly and the Standard Monitor board.
To remove the fan assembly, refer to Figures 1 and 2 and follow these steps:
1. Power down the instrument and disconnect the power cord.
2. Disconnect the Passive Monitor cable, if used. The Passive Monitor
connector is the 25 pin D-connector on the rear of the mainframe.
3. From the rear of the mainframe, use a Torx with a T-10 driver to remove the
four 8-32 screws (refer to Figure 1 for the screw locations).
4. Use a Torx with a T-20 driver to remove the 8-32 Safety Ground screw and
the Chassis Ground screw (if installed).
5. Gently pivot the fan assembly outward from the mainframe far enough to
access the fan cables on the right side of the mainframe.
6. Unplug the fan cables and set the fan assembly aside on a clean working
surface.
Remove Fan Assembly