©2008 Thermaco, Inc. • All rights reserved • Patented/Patents Pending • Specications subject to change without notice
8/08 Thermaco, Inc. • PO Box 2548 • Asheboro, NC 27204-2548 • Phone: (336) 629-4651 • Online: www.big-dipper.com 2
Trapzilla®Grease Trap System
Install “P” trap on outlet connection
of tank. (Note: the unit already has
an internal gas trap).
DON’T . . . Reduce pipe size on outlet piping.
DO . . .
READ instruction manual included with
system before doing anything.
Install unit allowing for the minimum
clearances shown.
Make piping connections with rubber
“No Hub” connectors.
Keep outlet piping as straight as pos-
sible. Use only “sweep” connections.
Install vent on outlet piping.
INSTALLATION INFORMATION
Suggested Minimum Footprint Dimensions
NOTE: Drawing for reference only. Equip-
ment must be installed in compliance with
all applicable laws, regulations and codes,
including plumbing codes. Installation should
be performed by a qualied plumber.
SOLIDS
U.S. and International Patents Issued and Pending
www. .com
AA
DO NOT USE
MECHANICAL CRUST
BREAKING DEVICES
GREASEGREASE
TZ-600 Specications
The Trapzilla® requires 6”
of clearance all the way
around the lid.
Job Specication:
Grease and oils separator(s) shall be Thermaco Trapzilla hydromechanical grease/oil interceptor system(s) as
manufactured by Thermaco, Inc., Asheboro, North Carolina as noted on plans.
Separator Specications:
Furnish and install ___ Thermaco Trapzilla Model No. TZ-600, linear low-density rotationally molded polyethylene
grease and oil separator(s) for below or above-ground installation, shall be ASME A112.14.3-rated at 75 GPM and
factory-rated at 150 gallons per minute peak ow, 600+ pounds of grease storage capacity with a at grease sepa-
ration efciency curve, crush-resistant cylindrical walls, twin integral portals for access by grease pump truck for
grease removal, single separate integral portal for vacuum access for removal of solids, self guiding pipe for pump
truck access/solids removal, integral non-oatation anchor ring for in-ground installation, integral horizontal bafe,
laminar inlet ow diverter, integral vessel vent, separate storage compartments for grease and solids, and including
as an integral part of the unit an integral gas trap and a fully removable polyethylene self-positioning keyed cover
equipped with sealed thread fasteners.