Thermo King MAGNUM PLUS 098212 User manual

Revision A
October 2019 TTKK 6600227755--44--MMMM--EENN
Container Edition
MAGNUM PLUS® with MP4000
Maintenance Manual

©2020 Trane Technologies TK 60275-4-MM-EN
Introduction
This manual is published for informational purposes only. Thermo King® makes no representations warranties express
or implied, with respect to the information recommendations and descriptions contained herein. Information provided
should not be regarded as all-inclusive or covering all contingencies. If further information is required, Thermo King
Corporation Service Department should be consulted.
TThheerrmmoo KKiinngg’’ss wwaarrrraannttyy sshhaallll nnoott aappppllyy ttoo aannyy eeqquuiippmmeenntt wwhhiicchh hhaass bbeeeenn ““ssoo iinnssttaalllleedd,, mmaaiinnttaaiinneedd,, rreeppaaiirreedd
oorr aalltteerreedd aass,, iinn tthhee mmaannuuffaaccttuurreerr’’ss jjuuddggmmeenntt,, ttoo aaffffeecctt iittss iinntteeggrriittyy..””
MMaannuuffaaccttuurreerr sshhaallll hhaavvee nnoo lliiaabbiilliittyy ttoo aannyy ppeerrssoonn oorr eennttiittyy ffoorr aannyy ppeerrssoonnaall iinnjjuurryy,, pprrooppeerrttyy ddaammaaggee oorr aannyy
ootthheerr ddiirreecctt,, iinnddiirreecctt,, ssppeecciiaall,, oorr ccoonnsseeqquueennttiiaall ddaammaaggeess wwhhaattssooeevveerr,, aarriissiinngg oouutt ooff tthhee uussee ooff tthhiiss mmaannuuaall oorr
aannyy iinnffoorrmmaattiioonn,, rreeccoommmmeennddaattiioonnss oorr ddeessccrriippttiioonnss ccoonnttaaiinneedd hheerreeiinn.. TThhee pprroocceedduurreess ddeessccrriibbeedd hheerreeiinn sshhoouulldd
oonnllyy bbee uunnddeerrttaakkeenn bbyy ssuuiittaabbllyy qquuaalliiffiieedd ppeerrssoonnnneell.. FFaaiilluurree ttoo iimmpplleemmeenntt tthheessee pprroocceedduurreess ccoorrrreeccttllyy mmaayy ccaauussee
ddaammaaggee ttoo tthhee TThheerrmmoo KKiinngg uunniitt oorr ootthheerr pprrooppeerrttyy oorr ppeerrssoonnaall iinnjjuurryy..
General Information
O_\ dX`ek\eXeZ\ `e]fidXk`fe `e k_`j dXelXc Zfm\ij le`k df[\cj6
H<BIPH KGPN ,54.-.
,54.-2
,54.-4
,54.-5
,54../
,5414,
,5414-
,5414.
,5414/
,54141
,54142
,54143
,54144
,54145
,5415,
,5415-
,5415.
,5415/
,54150
=Xj\ Pe`kj ,54.,/
Afi ]lik_\i `e]fidXk`fe( i\]\i kf6
H<BIPH KXikj G`jk KXikj HXelXc OF 10/12
?`X^efj`e^ O_\idf F`e^ >fekX`e\i M\]i`^\iXk`fe Npjk\dj OF 0--22
@c\ZkifjkXk`Z ?`jZ_Xi^\ $@N?% OiX`e`e^ Bl`[\ OF 0,.4.
@mXZlXk`fe NkXk`fe Jg\iXk`fe Xe[ A`\c[ <ggc`ZXk`fe OF 0,2-.
Offc >XkXcf^ OF 1511
O_\ `e]fidXk`fe `e k_`j dXelXc `j gifm`[\[ kf Xjj`jk fne\ij( fg\iXkfij( Xe[ j\im`Z\ g\fgc\ `e k_\ gifg\i lgb\\g Xe[ dX`ek\eXeZ\ f] O_\idf
F`e^ le`kj*
Revision History
M\m`j`fe < $JZk .,-5% I\n dXelXc ]fidXk( ^\e\iXc lg[Xk\j k_ifl^_flk dXelXc*

TK 60275-4-MM-EN 3
Recover Refrigerant
NNoottee:: In the USA, EPA Section 608 Certification is required to work on refrigeration systems. In the EU, local F-gas
Regulations must be observed when working on refrigeration systems.
At Thermo King®, we recognize the need to preserve the environment and limit the potential harm to the ozone layer
that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere.
When working on transport temperature control systems, a recovery process that prevents or minimizes refrigerant
loss to the atmosphere is required by law. In addition, service personnel must be aware of the appropriate European
Union, National, Federal, State, and/or Local regulations governing the use of refrigerants and certification of
technicians. For additional information on regulations and technician programs, contact your local THERMO KING
dealer.
SSeerrvviiccee TToooollss - Use the proper service tools. Gauge manifold sets should include appropriate shutoff valves or
disconnects near the end of each service line.
RReeccoovveerryy EEqquuiippmmeenntt - Recovery equipment must be used. Proper recovering, storing and recycling of refrigerants is
an important part of all service work.
SSeerrvviiccee PPrroocceedduurreess - Recommended procedures must be used to minimize refrigerant loss.
CCoommppoonneennttss mmaayy bbee iissoollaatteedd by closing service valves and performing system pump-downs.
CCoommppoonneennttss uunnaabbllee ttoo bbee iissoollaatteedd for service must be repaired only after refrigerant is properly recovered.
R-404A/R-452A
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
UUssee oonnllyy PPoollyyoolleesstteerr--bbaasseedd rreeffrriiggeerraattiioonn ccoommpprreessssoorr ooiill iinn RR--113344aa//RR--440044AA//RR--445522AA ssyysstteemmss.. SSeeee TThheerrmmoo KKiinngg
PPaarrttss MMaannuuaall ffoorr ppaarrtt nnuummbbeerr..
NNOOTTIICCEE
SSyysstteemm CCoonnttaammiinnaattiioonn!!
DDoo nnoott mmiixx PPoollyyoolleesstteerr aanndd ssttaannddaarrdd ssyynntthheettiicc ccoommpprreessssoorr ooiillss.. KKeeeepp PPoollyyoolleesstteerr ccoommpprreessssoorr ooiill iinn ttiigghhttllyy
sseeaalleedd ccoonnttaaiinneerrss.. IIff PPoollyyoolleesstteerr ooiill bbeeccoommeess ccoonnttaammiinnaatteedd wwiitthh mmooiissttuurree oorr ssttaannddaarrdd ooiillss,, ddiissppoossee ooff
pprrooppeerrllyy––DDOO NNOOTT UUSSEE..
NNOOTTIICCEE
SSyysstteemm CCoonnttaammiinnaattiioonn!!
WWhheenn sseerrvviicciinngg TThheerrmmoo KKiinngg RR--113344aa,, RR--440044AA oorr RR--445522AA uunniittss,, uussee oonnllyy tthhoossee sseerrvviiccee ttoooollss cceerrttiiffiieedd ffoorr aanndd
ddeeddiiccaatteedd ttoo RR--113344aa//RR--440044AA//RR--445522AA rreeffrriiggeerraanntt aanndd PPoollyyoolleesstteerr ccoommpprreessssoorr ooiillss.. RReessiidduuaall nnoonn--HHFFCC
rreeffrriiggeerraannttss oorr ooiillss wwiillll ccoonnttaammiinnaattee RR--113344aa//RR--440044AA//RR--445522AA ssyysstteemmss..
Customer Satisfaction Survey
Let your voice be heard!
Your feedback will help improve our manuals. The survey is accessible through any internet-connected device with a
web browser.
Scan the Quick Response (QR) code or click or type the web address https://tranetechnologies.iad1.qualtrics.com/jfe/
form/SV_2octfSHoUJxsk6x?Q_CHL=qr&Q_JFE=qdg to complete the survey.
IInnttrroodduuccttiioonn

4TK 60275-4-MM-EN
SSaaffeettyy PPrreeccaauuttiioonnss .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 1122
Danger, Warning, Caution, and Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
General Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Refrigerant Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Electrical Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
High Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Low Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electrostatic Discharge Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electrostatic Discharge and the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Welding of Units or Containers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
First Aid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Identifying Unit Safety and Warning Decals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Serial Number Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Component Serial Number Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SSeerrvviiccee GGuuiiddee .. .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 1199
SSppeecciiffiiccaattiioonnss .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 2200
System Net Cooling Capacity - Full Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Evaporator Airflow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Refrigeration System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Normal R-404A/R-452A System Operating Pressures (Scroll Compressor) . . . . . . . . . . . . . . . . . . . . . . . . . . 22
MP4000 Controller Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Metric Hardware Torque Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
UUnniitt DDeessccrriippttiioonn .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 2266
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Scroll Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Digital Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Intermediate Suction Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
MP4000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Power Module Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Compressor Digital Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Economizer Heat Exchange System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Fresh Air Exchange System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Receiver Tank Sight Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Evaporator Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table of Contents

TK 60275-4-MM-EN 5
Condenser Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
USDA Cold Treatment Temperature Recording (Standard). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Unit Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Electronic Chart Recorder (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Remote Monitoring Modem (RMM, RMM+) (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Suction and Discharge Pressure Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Water-Cooled Condenser/Receiver Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Air Ventilation Logging (AVL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Advanced Fresh Air Management (AFAM) System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
AFAM Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
AFAM Vent Door Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Advanced Fresh Air Management Plus (AFAM+) System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
CCoonnttrroolllleerr DDeessccrriippttiioonn .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .. .. .... .. .. .. .. .. .. .. .. 3366
MP4000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Back-up Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Input and Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Standard Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Idle Screen and Check Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Unit Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Display Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Mode Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Keys and Indicator LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Function Keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Special Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Indicator LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Software Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
OOppeerraattiinngg IInnssttrruuccttiioonnss .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .. .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 4488
Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Unit On/Off Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Unit Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Initiating a Manual Defrost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Pretrip Inspection (PTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Viewing Alarms/Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Display Alternate Fahrenheit (F) or Celsius (C) Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Changing Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Lock Padlock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Controller Back-up Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Controller Lockup Issue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Emergency Run Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Rotation Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
FULL COOL Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
DEFROST Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
TTaabbllee ooff CCoonntteennttss

6TK 60275-4-MM-EN
High or Low Speed Fans Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
NNaavviiggaattiinngg CCoonnttrroolllleerr OOppeerraattiinngg MMeennuu .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 5544
Menu Scrolling Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Changing Screen Contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
MMaaiinn MMeennuu.... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ...... 5566
Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Values Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Controls Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Cold Treatment (CT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Multiple Temperature Set (MTS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
OptiSet™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Temperature Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Controlling Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Pull Down Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Water Cooled Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Dehumidify Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Dehumidify Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
AVL (Air Ventilation Logging) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Fresh Air Vent Man - AFAM Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Fresh Air Vent Man - AFAM+ Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
AFAM Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
AFAM Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
AFAM+ CO2 Max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
AFAM+ O2 Min. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Smart PTI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Alarm Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Alarm Code States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Message Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Configuration Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Calibrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Icon Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Log View Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Info Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
SSppeecciiaall FFuunnccttiioonn KKeeyyss -- UUsseerr AAccttiivvaatteedd CCoommmmaannddss .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 7766
PTI Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Defrost Key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
TTaabbllee ooff CCoonntteennttss

TK 60275-4-MM-EN 7
PTI (Pretrip) Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Manual Function Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Function Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
AAiirr VVeennttiillaattiioonn LLooggggiinngg ((AAVVLL)) .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8833
AAddvvaanncceedd FFrreesshh AAiirr MMaannaaggeemmeenntt ((AAFFAAMM)) SSyysstteemm .. .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8844
Starting the AFAM System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Change the AFAM Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Change the AFAM Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
AAddvvaanncceedd FFrreesshh AAiirr MMaannaaggeemmeenntt PPlluuss ((AAFFAAMM++)) SSyysstteemm .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8877
Set AFAM+ System Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Change the AFAM Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Change the CO2 Minimum and Maximum Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Change the AFAM+ Settings Using OptiSet™. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Modify OptiSet Product Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Testing AFAM / AFAM+ System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
AFAM+ Option Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
System Operation Verification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Alarm Codes and Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
PPuullssaattiinngg VVeenntt DDoooorr .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .. .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 9933
AFAM+ Door Closes Automatically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Pulsating AFAM+ Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
AFAM+ Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
OOppeerraattiinngg TThheeoorryy .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 9944
Chill Loads (Setpoint at -9.9 C [14.1 F] and Above) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Supply Air Sensor Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Frozen Loads (Setpoint at -10 C [14 F] and Below). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Cooling Capacity Display in Main Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Power Limit Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Compressor Vapor Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
High Temperature Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Power Limit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Evaporator Fan Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Chill Loads (Setpoints of -9.9 C [14.1 F] and Above) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Frozen Loads (Setpoint at -10.0 C [14.0 F] or Below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Condenser Fan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Probe Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Dehumidify Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
TTaabbllee ooff CCoonntteennttss

8TK 60275-4-MM-EN
Continuous Temperature Control Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Chill Loads (Controller Setpoint at -9.9 C [14.1 F] and Above). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Cool with Modulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Heat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Frozen Loads (Controller Setpoint at -10 C [14 F] and Below) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Cool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Null . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Defrost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Compressor Digital Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Economizer System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Data Recording and Downloading Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Cold Treatment (CT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Multiple Temperature Setpoint (MTS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
CCoonnttrroolllleerr MMaaiinntteennaannccee.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..110077
Controller Door Open and Close Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Flashloading Controller Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
MP4000 Test System Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Controller Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
EElleeccttrriiccaall MMaaiinntteennaannccee.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..111111
Unit Protection Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Main Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Evaporator Overheat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
High Pressure Cutout Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
High Pressure Cutout Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
High Pressure Cutout Switch Removal/Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Low Pressure Cutout Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Low Pressure Cutout Switch or Suction Transducer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Discharge and Low Pressure Sensors (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Condenser Fan and Evaporator Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Check Condenser Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Check Evaporator Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Reversing Power Phase on MAGNUM Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Evaporator Heater Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Extended Capacity Heaters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Electric Heaters Malfunction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Compressor Discharge Temperature Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
TTaabbllee ooff CCoonntteennttss

TK 60275-4-MM-EN 9
Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Sensor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Sensor Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Resistance Values for Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
RReeffrriiggeerraattiioonn MMaaiinntteennaannccee .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .... .. .. .. .. .. .. ..112233
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Vacuum Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Filters and Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Refrigerant Recovery Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Detecting Leaks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Special Service Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Oil Acid Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Isolate Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Gauge Manifold Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Using a New Gauge Manifold Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Gauge Manifold Valve Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Gauge Manifold Set Installation & Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Checking Refrigerant Charge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Receiver Tank Sight Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Leak Testing Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Using Pressurized Nitrogen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Purge High Side to Low Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Maximum Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Recovering Refrigerant from System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Evacuation and Cleanup of Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Unit Preparation and Hookup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Unit Evacuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Pressure Rise Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Factors Affecting Speed of System Evacuation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Heat Saves Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Charging System with Refrigerant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Unit Charging by Weight (from an Evacuated Condition) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Evacuation Station Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Compressor Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
TTaabbllee ooff CCoonntteennttss

10 TK 60275-4-MM-EN
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Condenser Coil Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Filter Drier/In-line Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Evaporator Expansion Valve (TXV) Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Economizer Expansion Valve Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Economizer Heat Exchanger Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Receiver Tank/ Water-Cooled Condenser Tank Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
Vapor Injection Valve Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Compressor Digital Control Valve Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
SSeerrvviicciinngg tthhee UUnniitt .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..114477
Taking Care of the Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Inspecting Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Checking Mounting Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Cleaning the Condenser Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Cleaning the Evaporator Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Cleaning the Defrost Drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Positioning the Condenser Fan Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Positioning the Evaporator Fan Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Adjusting the Fresh Air Exchange System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
DDiiaaggnnoossttiiccss .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .... .. .. .. .. .. .. ..115500
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
MP4000 Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Mechanical Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Refrigeration Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Status Messages and Controller Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Alarm Codes and Corrective Actions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
TTaabbllee ooff CCoonntteennttss

TK 60275-4-MM-EN 11
DDiiaaggrraammss .. .... .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .... .. .. .. .... ..118822
Diagram Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
TTaabbllee ooff CCoonntteennttss

12 TK 60275-4-MM-EN
Safety Precautions
Danger, Warning, Caution, and Notice
Thermo King® recommends that all service be performed by a Thermo King dealer and to be aware of several general
safety practices.
Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this unit
depend upon the strict observance of these precautions.
De[`ZXk\j Xe `dd`e\ekcp _XqXi[flj j`klXk`fe n_`Z_( `] efk Xmf`[\[( n`cc i\jlck `e [\Xk_ fi j\i`flj `ealip*
De[`ZXk\j X gfk\ek`Xccp _XqXi[flj j`klXk`fe n_`Z_( `] efk Xmf`[\[( Zflc[ i\jlck `e [\Xk_ fi j\i`flj `ealip*
De[`ZXk\j X gfk\ek`Xccp _XqXi[flj j`klXk`fe n_`Z_( `] efk Xmf`[\[( Zflc[ i\jlck `e d`efi fi df[\iXk\ `ealip Xe[ lejX]\
giXZk`Z\j*
De[`ZXk\j X j`klXk`fe k_Xk Zflc[ i\jlck `e \hl`gd\ek fi gifg\ikp)[XdX^\ fecp XZZ`[\ekj*
General Practices
DDAANNGGEERR
HHaazzaarrdd ooff EExxpplloossiioonn!!
NNeevveerr aappppllyy hheeaatt ttoo aa sseeaalleedd rreeffrriiggeerraattiioonn ssyysstteemm oorr ccoonnttaaiinneerr.. HHeeaatt iinnccrreeaasseess iinntteerrnnaall pprreessssuurree,, wwhhiicchh mmiigghhtt
ccaauussee aann eexxpplloossiioonn rreessuullttiinngg iinn ddeeaatthh oorr sseerriioouuss iinnjjuurryy..
DDAANNGGEERR
HHaazzaarrddoouuss GGaasseess!!
RReeffrriiggeerraanntt iinn tthhee pprreesseennccee ooff aann ooppeenn ffllaammee,, ssppaarrkk,, oorr eelleeccttrriiccaall sshhoorrtt pprroodduucceess ttooxxiicc ggaasseess tthhaatt aarree sseevveerree
rreessppiirraattoorryy iirrrriittaannttss wwhhiicchh ccaann ccaauussee sseerriioouuss iinnjjuurryy oorr ppoossssiibbllee ddeeaatthh..
DDAANNGGEERR
RRiisskk ooff IInnjjuurryy!!
KKeeeepp yyoouurr hhaannddss,, ccllootthhiinngg,, aanndd ttoooollss cclleeaarr ooff ffaannss aanndd//oorr bbeellttss wwhheenn wwoorrkkiinngg oonn aa uunniitt tthhaatt iiss rruunnnniinngg oorr wwhheenn
ooppeenniinngg oorr cclloossiinngg ccoommpprreessssoorr sseerrvviiccee vvaallvveess.. LLoooossee ccllootthhiinngg mmiigghhtt eennttaannggllee mmoovviinngg ppuulllleeyyss oorr bbeellttss,, ccaauussiinngg
sseerriioouuss iinnjjuurryy oorr ppoossssiibbllee ddeeaatthh..
DDAANNGGEERR
RReeffrriiggeerraanntt VVaappoorr HHaazzaarrdd!!
DDoo nnoott iinnhhaallee rreeffrriiggeerraanntt.. UUssee ccaauuttiioonn wwhheenn wwoorrkkiinngg wwiitthh rreeffrriiggeerraanntt oorr aa rreeffrriiggeerraattiioonn ssyysstteemm iinn aannyy ccoonnffiinneedd
aarreeaa wwiitthh aa lliimmiitteedd aaiirr ssuuppppllyy.. RReeffrriiggeerraanntt ddiissppllaacceess aaiirr aanndd ccaann ccaauussee ooxxyyggeenn ddeepplleettiioonn,, rreessuullttiinngg iinn
ssuuffffooccaattiioonn aanndd ppoossssiibbllee ddeeaatthh..
WWAARRNNIINNGG
HHaazzaarrdd ooff EExxpplloossiioonn!!
NNeevveerr cclloossee tthhee ccoommpprreessssoorr ddiisscchhaarrggee sseerrvviiccee vvaallvvee wwhheenn tthhee uunniitt iiss ooppeerraattiinngg.. NNeevveerr ooppeerraattee tthhee uunniitt wwiitthh
tthhee ddiisscchhaarrggee vvaallvvee cclloosseedd ((ffrroonntt sseeaatteedd)).. TThhiiss ccoonnddiittiioonn iinnccrreeaasseess iinntteerrnnaall pprreessssuurree,, wwhhiicchh ccaann ccaauussee aann
eexxpplloossiioonn..

TK 60275-4-MM-EN 13
WWAARRNNIINNGG
PPrrooppeerr EEqquuiippmmeenntt CCoonnddiittiioonn!!
GGaauuggee mmaanniiffoolldd hhoosseess mmuusstt bbee iinn ggoooodd ccoonnddiittiioonn bbeeffoorree uussiinngg tthheemm.. NNeevveerr lleett tthheemm ccoommee iinn ccoonnttaacctt wwiitthh
mmoovviinngg bbeellttss,, ffaannss,, ppuulllleeyyss oorr hhoott ssuurrffaacceess.. DDeeffeeccttiivvee ggaauuggee eeqquuiippmmeenntt ccaann ddaammaaggee ccoommppoonneennttss oorr ccaauussee
sseerriioouuss iinnjjuurryy..
WWAARRNNIINNGG
PPeerrssoonnaall PPrrootteeccttiivvee EEqquuiippmmeenntt ((PPPPEE)) RReeqquuiirreedd!!
AAllwwaayyss wweeaarr ggoogggglleess oorr ssaaffeettyy ggllaasssseess wwhheenn wwoorrkkiinngg oonn aa uunniitt.. RReeffrriiggeerraanntt lliiqquuiidd,, ooiill,, aanndd bbaatttteerryy aacciidd ccaann
ppeerrmmaanneennttllyy ddaammaaggee yyoouurr eeyyeess.. SSeeee ““FFiirrsstt AAiidd””..
WWAARRNNIINNGG
EEqquuiippmmeenntt DDaammaaggee aanndd RRiisskk ooff IInnjjuurryy!!
NNeevveerr ddrriillll hhoolleess iinnttoo tthhee uunniitt uunnlleessss iinnssttrruucctteedd bbyy TThheerrmmoo KKiinngg.. HHoolleess ddrriilllleedd iinnttoo hhiigghh vvoollttaaggee ccaabblleess ccoouulldd
ccaauussee aann eelleeccttrriiccaall ffiirree,, sseevveerree ppeerrssoonnaall iinnjjuurryy,, oorr eevveenn ddeeaatthh..
WWAARRNNIINNGG
RRiisskk ooff IInnjjuurryy!!
WWhheenn uussiinngg llaaddddeerrss ttoo iinnssttaallll oorr sseerrvviiccee rreeffrriiggeerraattiioonn ssyysstteemmss,, aallwwaayyss oobbsseerrvvee tthhee llaaddddeerr mmaannuuffaaccttuurreerr’’ss
ssaaffeettyy llaabbeellss aanndd wwaarrnniinnggss.. AA wwoorrkk ppllaattffoorrmm oorr ssccaaffffoollddiinngg iiss tthhee rreeccoommmmeennddeedd mmeetthhoodd ffoorr iinnssttaallllaattiioonnss aanndd
sseerrvviicciinngg..
CCAAUUTTIIOONN
SShhaarrpp EEddggeess!!
EExxppoosseedd ccooiill ffiinnss ccaann ccaauussee llaacceerraattiioonnss.. SSeerrvviiccee wwoorrkk oonn tthhee eevvaappoorraattoorr oorr ccoonnddeennsseerr ccooiillss iiss bbeesstt lleefftt ttoo aa
cceerrttiiffiieedd TThheerrmmoo KKiinngg tteecchhnniicciiaann..
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
AAllll mmoouunnttiinngg bboollttss mmuusstt bbee tthhee ccoorrrreecctt lleennggtthh ffoorr tthheeiirr aapppplliiccaattiioonnss aanndd ttoorrqquueedd ttoo ssppeecciiffiiccaattiioonn.. IInnccoorrrreecctt bboolltt
lleennggtthhss aanndd iimmpprrooppeerr ttoorrqquuee ssppeecciiffiiccaattiioonnss ccaann ddaammaaggee eeqquuiippmmeenntt..
Refrigerant Hazards
DDAANNGGEERR
HHaazzaarrddoouuss PPrreessssuurreess!!
AAllwwaayyss ssttoorree rreeffrriiggeerraanntt iinn pprrooppeerr ccoonnttaaiinneerrss,, oouutt ooff ddiirreecctt ssuunnlliigghhtt aanndd aawwaayy ffrroomm iinntteennssee hheeaatt.. HHeeaatt
iinnccrreeaasseess pprreessssuurree iinnssiiddee ssttoorraaggee ccoonnttaaiinneerrss,, wwhhiicchh ccaann ccaauussee tthheemm ttoo bbuurrsstt aanndd ccoouulldd rreessuulltt iinn sseevveerree
ppeerrssoonnaall iinnjjuurryy..
DDAANNGGEERR
CCoommbbuussttiibbllee HHaazzaarrdd!!
DDoo nnoott uussee ooxxyyggeenn ((OO22 )) oorr ccoommpprreesssseedd aaiirr ffoorr lleeaakk tteessttiinngg.. OOxxyyggeenn mmiixxeedd wwiitthh rreeffrriiggeerraanntt iiss ccoommbbuussttiibbllee..
WWAARRNNIINNGG
HHaazzaarrddoouuss GGaasseess!!
DDoo nnoott uussee aa HHaalliiddee ttoorrcchh.. WWhheenn aa ffllaammee ccoommeess iinn ccoonnttaacctt wwiitthh rreeffrriiggeerraanntt,, ttooxxiicc ggaasseess aarree pprroodduucceedd.. TThheessee
ggaasseess ccaann ccaauussee ssuuffffooccaattiioonn,, eevveenn ddeeaatthh..
SSaaffeettyy PPrreeccaauuttiioonnss

14 TK 60275-4-MM-EN
WWAARRNNIINNGG
PPeerrssoonnaall PPrrootteeccttiivvee EEqquuiippmmeenntt ((PPPPEE)) RReeqquuiirreedd!!
RReeffrriiggeerraanntt iinn aa lliiqquuiidd ssttaattee eevvaappoorraatteess rraappiiddllyy wwhheenn eexxppoosseedd ttoo tthhee aattmmoosspphheerree,, ffrreeeezziinngg aannyytthhiinngg iitt ccoonnttaaccttss..
WWeeaarr bbuuttyyll lliinneedd gglloovveess aanndd ootthheerr ccllootthhiinngg aanndd eeyyee wweeaarr wwhheenn hhaannddlliinngg rreeffrriiggeerraanntt ttoo hheellpp pprreevveenntt ffrroossttbbiittee..
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
WWhheenn bbeeiinngg ttrraannssffeerrrreedd,, rreeffrriiggeerraanntt mmuusstt bbee iinn lliiqquuiidd ssttaattee ttoo aavvooiidd ppoossssiibbllee eeqquuiippmmeenntt ddaammaaggee..
Electrical Hazards
EElleeccttrriiccaall PPrreeccaauuttiioonnss
• The possibility of serious or fatal injury from electrical shock exists when servicing a refrigeration unit. Extreme care
must be used when working with a refrigeration unit that is connected to its power source.
• Extreme care must be used even if the unit is not running. Lethal voltage potentials can exist at the unit power cord,
inside the control box, inside any high voltage junction box, at the motors and within the wiring harnesses.
• In general, disconnect the units power cord before repairing or changing any electrical components.
• Even though the controller is turned off, one of the phases is still live and represents a potential danger of
electrocution.
High Voltage
DDAANNGGEERR
HHaazzaarrddoouuss VVoollttaaggee!!
LLeetthhaall aammoouunnttss ooff vvoollttaaggee aarree pprreesseenntt iinn ssoommee eelleeccttrriiccaall cciirrccuuiittss.. UUssee eexxttrreemmee ccaarree wwhheenn wwoorrkkiinngg oonn aann
ooppeerraattiinngg rreeffrriiggeerraattiioonn uunniitt..
WWAARRNNIINNGG
HHaazzaarrddoouuss VVoollttaaggee!!
TTrreeaatt aallll wwiirreess aanndd ccoonnnneeccttiioonnss aass iiff tthheeyy wweerree hhiigghh vvoollttaaggee uunnttiill aa mmeetteerr aanndd wwiirriinngg ddiiaaggrraamm iinnddiiccaattee
ootthheerrwwiissee.. OOnnllyy uussee ttoooollss wwiitthh iinnssuullaatteedd hhaannddlleess.. NNeevveerr hhoolldd uunniinnssuullaatteedd mmeettaall ttoooollss nneeaarr eexxppoosseedd,, eenneerrggiizzeedd
ccoonndduuccttoorrss..
WWAARRNNIINNGG
HHaazzaarrddoouuss VVoollttaaggee!!
NNeevveerr wwoorrkk aalloonnee oonn hhiigghh vvoollttaaggee cciirrccuuiittss iinn tthhee rreeffrriiggeerraattiioonn uunniitt.. AAnnootthheerr ppeerrssoonn sshhoouulldd bbee nneeaarrbbyy ttoo sshhuutt
ooffff tthhee uunniitt aanndd pprroovviiddee aaiidd iinn tthhee eevveenntt ooff aann aacccciiddeenntt..
WWAARRNNIINNGG
PPeerrssoonnaall PPrrootteeccttiivvee EEqquuiippmmeenntt ((PPPPEE)) RReeqquuiirreedd!!
SSaaffeettyy ggllaasssseess,, rruubbbbeerr--iinnssuullaatteedd gglloovveess,, aanndd ccaabbllee ccuutttteerrss sshhoouulldd bbee nneeaarr yyoouurr wwoorrkk aarreeaa iinn tthhee eevveenntt ooff aann
eelleeccttrriiccaall aacccciiddeenntt..
WWAARRNNIINNGG
HHaazzaarrddoouuss VVoollttaaggee!!
TThhee uunniitt OOnn//OOffff sswwiittcchh mmuusstt bbee ttuurrnneedd OOffff bbeeffoorree ccoonnnneeccttiinngg oorr ddiissccoonnnneeccttiinngg tthhee ssttaannddbbyy ppoowweerr pplluugg.. NNeevveerr
aatttteemmpptt ttoo ssttoopp tthhee uunniitt bbyy ddiissccoonnnneeccttiinngg tthhee ppoowweerr pplluugg..
SSaaffeettyy PPrreeccaauuttiioonnss

TK 60275-4-MM-EN 15
WWAARRNNIINNGG
RRiisskk ooff IInnjjuurryy!!
TThhee uunniitt ppoowweerr pplluugg mmuusstt bbee cclleeaann aanndd ddrryy bbeeffoorree ccoonnnneeccttiinngg iitt ttoo aa ppoowweerr ssoouurrccee..
WWAARRNNIINNGG
RRiisskk ooff IInnjjuurryy!!
DDoo nnoott mmaakkee rraappiidd mmoovveess wwhheenn wwoorrkkiinngg oonn hhiigghh vvoollttaaggee cciirrccuuiittss iinn rreeffrriiggeerraattiioonn uunniittss.. DDoo nnoott ggrraabb ffoorr ffaalllliinngg
ttoooollss bbeeccaauussee yyoouu mmiigghhtt aacccciiddeennttaallllyy ttoouucchh aa hhiigghh vvoollttaaggee ssoouurrccee..
Low Voltage
WWAARRNNIINNGG
LLiivvee EElleeccttrriiccaall CCoommppoonneennttss!!
CCoonnttrrooll cciirrccuuiittss aarree llooww vvoollttaaggee ((2244 VVaacc aanndd 1122 VVddcc)).. TThhiiss vvoollttaaggee ppootteennttiiaall iiss nnoott ccoonnssiiddeerreedd ddaannggeerroouuss.. LLaarrggee
aammoouunntt ooff ccuurrrreenntt aavvaaiillaabbllee ((oovveerr 3300 aammppeerreess)) ccaann ccaauussee sseevveerree bbuurrnnss iiff sshhoorrtteedd ttoo ggrroouunndd.. DDoo nnoott wweeaarr
jjeewweellrryy,, wwaattcchh oorr rriinnggss.. TThheessee iitteemmss ccaann sshhoorrttccuutt eelleeccttrriiccaall cciirrccuuiittss aanndd ccaauussee sseevveerree bbuurrnnss ttoo tthhee wweeaarreerr..
Electrostatic Discharge Precautions
Precautions must be taken to prevent electrostatic discharge while servicing the microprocessor controller and related
components. The risk of significant damage to the electronic components of the unit is possible if these precautionary
measures are not followed. The primary risk potential results from the failure to wear adequate electrostatic discharge
preventive equipment when handling and servicing the controller. The second cause results from electric welding on
the unit and container chassis without taking precautionary steps.
Electrostatic Discharge and the Controller
You must avoid electrostatic discharges when servicing the controller. Solid-state integrated circuit components can be
severely damaged or destroyed with less than a small spark from a finger to metal object. You must rigidly adhere to
the following statements when servicing these units. This will avoid controller damage or destruction.
• Disconnect all power to the unit.
• Avoid wearing clothing that generates static electricity (wool, nylon, polyester, etc.).
• Do wear a static discharge wrist strap (refer to Tool Catalog) with the lead end connected to the controller's ground
terminal. These straps are available at most electronic equipment distributors. Do not wear these straps with power
applied to the unit.
• Avoid contacting the electronic components on the circuit boards of the unit being serviced.
• Leave the circuit boards in their static proof packing materials until ready for installation.
• Return a defective controller for repair in the same static protective packing materials from which the replacement
component was removed.
• Check the wiring after servicing the unit for possible errors. Complete this task before restoring power.
Welding of Units or Containers
Electric welding can cause serious damage to electronic circuits when performed on any portion of the refrigeration
unit, container, or container chassis with the refrigeration unit attached. It is necessary to ensure that welding currents
are not allowed to flow through the electronic circuits of the unit. The following statements must be rigidly adhered to
when servicing these units to avoid damage or destruction.
• Disconnect all power to the refrigeration unit.
• Disconnect all quick-disconnect wire harnesses from the back of the controller.
• Disconnect all wire harnesses from the Remote Monitor Modem (RMM).
• Switch all of the electrical circuit breakers in the control box to the Off position.
SSaaffeettyy PPrreeccaauuttiioonnss

16 TK 60275-4-MM-EN
• Weld unit and/or container per normal welding procedures. Keep ground return electrode as close to the area to be
welded as practical. This will reduce the likelihood of stray welding currents passing through any electrical or
electronic circuits.
• The unit power cables, wiring and circuit breakers must be restored to their normal condition when the welding
operation is completed.
First Aid
RREEFFRRIIGGEERRAANNTT
• EEyyeess:: For contact with liquid, immediately flush eyes with large amounts of water and get prompt medical
attention.
• SSkkiinn:: Flush area with large amounts of warm water. Do not apply heat. Remove contaminated clothing and shoes.
Wrap burns with dry, sterile, bulky dressing to protect from infection. Get prompt medical attention. Wash
contaminated clothing before reuse.
• IInnhhaallaattiioonn:: Move victim to fresh air and use Cardio Pulmonary Resuscitation (CPR) or mouth-to-mouth
resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive.
• FFrroosstt BBiittee:: In the event of frost bite , the objectives of First Aid are to protect the frozen area from further injury,
warm the affected area rapidly, and to maintain respiration.
RREEFFRRIIGGEERRAANNTT OOIILL
• EEyyeess:: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention.
• SSkkiinn:: Remove contaminated clothing. Wash thoroughly with soap and water. Get medical attention if irritation
persists.
• IInnhhaallaattiioonn:: Move victim to fresh air and use Cardio Pulmonary Resuscitation (CPR) or mouth-to-mouth
resuscitation to restore breathing, if necessary. Stay with victim until emergency personnel arrive.
• IInnggeessttiioonn:: Do not induce vomiting. Immediately contact local poison control center or physician.
EENNGGIINNEE CCOOOOLLAANNTT
• EEyyeess:: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention.
• SSkkiinn:: Remove contaminated clothing. Wash thoroughly with soap and water. Get medical attention if irritation
persists.
• IInnggeessttiioonn:: Do not induce vomiting. Immediately contact local poison control center or physician.
BBAATTTTEERRYY AACCIIDD
• EEyyeess:: Immediately flush with large amounts of water for at least 15 minutes. Get prompt medical attention. Wash
skin with soap and water.
EELLEECCTTRRIICCAALL SSHHOOCCKK
Take IMMEDIATE action after a person has received an electrical shock. Get quick medical assistance, if possible.
The source of the shock must be quickly stopped, by either shutting off the power or removing the victim. If the power
cannot be shut off, the wire should be cut with an non-conductive tool, such as a wood-handle axe or thickly insulated
cable cutters. Rescuers should wear insulated gloves and safety glasses, and avoid looking at wires being cut. The
ensuing flash can cause burns and blindness.
If the victim must be removed from a live circuit, pull the victim away with a non-conductive material. Use wood, rope,
a belt or coat to pull or push the victim away from the current. DO NOT TOUCH the victim. You will receive a shock from
current flowing through the victim’s body. After separating the victim from power source, immediately check for signs
of a pulse and respiration. If no pulse is present, start Cardio Pulmonary Resuscitation (CPR). If a pulse is present,
respiration might be restored by using mouth-to-mouth resuscitation. Call for emergency medical assistance.
AASSPPHHYYXXIIAATTIIOONN
Move victim to fresh air and use Cardio Pulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore
breathing, if necessary. Stay with victim until emergency personnel arrive.
SSaaffeettyy PPrreeccaauuttiioonnss

TK 60275-4-MM-EN 17
Identifying Unit Safety and Warning Decals
Serial number decals, refrigerant type decals, and warning decals appear on all Thermo King® equipment. These
decals provide information that may be needed to service or repair the unit. Service technicians should read and follow
the instructions on all warning decals.
Figure 1. Nameplate and Warning Locations
- >fekifcc\i IXd\gcXk\
. Pe`k IXd\gcXk\
/ >fdgi\jjfi IXd\gcXk\
Serial Number Location
Serial numbers can be found on the component’s nameplate.
• Electric Motor: Attached to the motor housing.
• Compressor: On front of the compressor.
• Unit: On unit frame in power cord storage compartment.
• Controller: On top of controller.
Component Serial Number Identification
To better identify the different electronic components, our supplier has changed their serial number labeling on the
MP4000 controller and power module. The label will show part number, date, and sequence.
MP4000 Controller: New label shows controller ID ABS782800212245390
Part number: ABS7828002; Date: 2012 24 wk 1224; Sequence 5390
ID in controller would show 1224-5390
SSaaffeettyy PPrreeccaauuttiioonnss


TK 60275-4-MM-EN 19
Service Guide
A closely followed maintenance program will help to keep your Thermo King unit in top operating condition. The
following table should be used as a guide when inspecting or servicing components on this unit.
Pretrip Every
1,000
Hours
Annual/
Yearly
Inspect/Service These Items
Electrical:
s K\i]fid X Zfekifcc\i gi\ki`g `ejg\Zk`fe $KOD% Z_\Zb*
s s s Q`jlXccp Z_\Zb Zfe[\ej\i ]Xe Xe[ \mXgfiXkfi ]Xe*
s s s Q`jlXccp `ejg\Zk \c\Zki`ZXc ZfekXZkj ]fi [XdX^\ fi cffj\ Zfee\Zk`fej*
s s s Q`jlXccp `ejg\Zk n`i\ _Xie\jj\j ]fi [XdX^\ fi cffj\ Zfee\Zk`fej*
s s ?fnecfX[ k_\ [XkX cf^^\i Xe[ Z_\Zb [XkX ]fi Zfii\Zk cf^^`e^*
s>_\Zb fg\iXk`fe f] gifk\Zk`fe j_lk[fne Z`iZl`kj*
Refrigeration:
s s s >_\Zb i\]i`^\iXek Z_Xi^\*
s s >_\Zb ]fi gifg\i [`jZ_Xi^\ Xe[ jlZk`fe gi\jjli\j*
s>_\Zb ]`ck\i [i`\i+`e)c`e\ ]`ck\i ]fi X i\jki`Zk`fe gi\jjli\j*
Structural:
s s s Q`jlXccp `ejg\Zk le`k ]fi [XdX^\[( cffj\( fi Yifb\e gXikj*
s s s O`^_k\e le`k( Zfdgi\jjfi Xe[ ]Xe dfkfi dflek`e^ Yfckj*
s s >c\Xe \ek`i\ le`k `eZcl[`e^ Zfe[\ej\i Xe[ \mXgfiXkfi Zf`cj Xe[ [\]ifjk [iX`ej*
Note: If a unit has been carrying cargo which contains a high level of sulphor or phosphorous (e.g., garlic, salted fish etc.),
it is recommended to clean the evaporator coil after each trip.

20 TK 60275-4-MM-EN
Specifications
System Net Cooling Capacity - Full Cool
Table 1. MAGNUM PLUS Model - Air Cooled Condensing*
Return air to evaporator
coil inlet
460/230V, 3 Phase, 60 Hz Power
Net Cooling Capacity Power Consumption
60 Hz Capacity B/hr 60 Hz Capacity kW 60 Hz Power kW
.-*- > $3, A% 12(3,, -2*2,/ --*11
-*3 > $/1 A% 0,( 501 --*55, --*,/
)-3*4 > $, A% .0(341 3*.14 3*13
).5 > $)., A% -3( .-1 1(,0- 2*2
)/1 > $)/- A% -0(,,, 0*-,0 2*,/
&Npjk\d e\k Zffc`e^ ZXgXZ`kp n`k_ X /4 > $-,, A% XdY`\ek X`i k\dg\iXkli\ Xe[ M)0,0<+M)01.<*
Evaporator Airflow
Table 2. System Net Heating Capacity*
460/230V, 3 Phase, 60 Hz Power 380/190V, 3 Phase, 50 Hz Power
Heating Capacity Heating Capacity
Watts Kcal/hr BTU/hr Watts Kcal/hr BTU/hr
H<BIPH KGPN
efidXc
1(.1, 0(1-1 -3(5-0 /(5,, /(/1/ -/(/,,
H<BIPH KGPN
\ok\e[\[
3(.1, 2(./0 .0(3/4 1(11, 0(33. -4(5/3
&Npjk\d e\k _\Xk`e^ ZXgXZ`kp `eZcl[\j \c\Zki`Z i\j`jkXeZ\ if[j Xe[ ]Xe _\Xk*
Table 3. MAGNUM PLUS
External
Static
Pressure
(Pa)
460/230V, 3 Phase, 60 Hz Power 380/190V, 3 Phase, 50 Hz Power
High Speed Low Speed High Speed Low Speed
m3/hr ft3/min m3/hr ft3/min m3/hr ft3/min m3/hr ft3/min
, 12-/ //,0 .451 -3,0 031. .353 .0-1 -0.-
-,, 05/, .5,. -//1 342 /5// ./-1 03/ .34
.,, 0,20 ./5. x x .4// -223 x x
/,, /-/. -400 x x -230 541 x x
0,, .,11 -.-, x x 004 .20 x x
1,, 52/ 123 x x x x x x
Other manuals for MAGNUM PLUS 098212
1
This manual suits for next models
19
Popular Power Supply manuals by other brands

Rigol
Rigol DP700 Series Calibration guide

Tyba
Tyba TY-B-PDC user guide

Emerson
Emerson Libert AC Power System Brochure & specs

ADTRAN
ADTRAN NetVanta 1131 RPS/EPS quick start guide

Manson Engineering Industrial
Manson Engineering Industrial HCS Series user manual

Spellman
Spellman EBM30N/TEG Installation and user guide