Thies CLIMA 5.4103.20.041 User manual

Precipitation Sensor
Instruction for Use
with analogue Intensity Output
5.4103.20.041, 5.4103.20.641, 5.4103.20.741, 5.4103.26.041
Dok. No. 021335/10/23
T H E W O R L D O F W E A T H E R D A T A

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 2 of 16
Safety Instructions
•Before operating with or at the device/product, read through the operating instructions.
This manual contains instructions which should be followed on mounting, start-up, and operation.
A non-observance might cause:
- failure of important functions
- endangerment of persons by electrical or mechanical effect
- damage to objects
•Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified
technician who is familiar with and observes the engineering regulations, provisions and standards
applicable in each case.
•Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG.
Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG
should be used for repairs.
•Electrical devices/products must be mounted and wired only in a voltage-free state.
•Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no
modifications have been made to the mechanics, electronics or software, and that the following points
are observed:
•All information, warnings and instructions for use included in these operating instructions must be taken
into account and observed as this is essential to ensure trouble-free operation and a safe condition of
the measuring system / device / product.
•The device / product is designed for a specific application as described in these operating instructions.
•The device / product should be operated with the accessories and consumables supplied and/or
recommended by Adolf Thies GmbH & Co KG.
•Recommendation: As it is possible that each measuring system / device / product may, under certain
conditions, and in rare cases, may also output erroneous measuring values, it is recommended using
redundant systems with plausibility checks for security-relevant applications.
Environment
•As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to
the objectives of environmental protection and is therefore willing to take back all
supplied products governed by the provisions of "ElektroG" (German Electrical and
Electronic Equipment Act) and to perform environmentally compatible disposal and
recycling. We are prepared to take back all Thies products concerned free of charge if
returned to Thies by our customers carriage-paid.
•Make sure you retain packaging for storage or transport of products. Should packaging
however no
longer be required, please arrange for recycling as the packaging materials
are designed to be recycled.
Documentation
•© Copyright Adolf Thies GmbH & Co KG, Göttingen / Germany
•Although these operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG
can accept no liability whatsoever for any technical and typographical errors or omissions in this
document that might remain.
•We can accept no liability whatsoever for any losses arising from the information contained in this
document.
•Subject to modification in terms of content.
•The device / product should not be passed on without the/these operating instructions.

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 3 of 16
Contents
1Models available ................................................................................................................4
2Application .........................................................................................................................4
3Construction and Mode of Operation..................................................................................4
4Installation..........................................................................................................................5
4.1 Mechanical Mounting...................................................................................................5
4.2 Electrical Mounting for Precipitation Sensor with Cable Gland.....................................6
4.3Electrical Mounting for Precipitation Sensor with Plug Connection...............................7
4.3.1 Plug Mounting .......................................................................................................7
4.4 Connecting Diagram....................................................................................................8
5Taking into Operation.........................................................................................................9
6Maintenance ......................................................................................................................9
7Technical Data.................................................................................................................10
8Dimension diagram..........................................................................................................11
9Accessories (Optional).....................................................................................................12
10 EC-Declaration of Conformity...........................................................................................13
11 UK-CA-Declaration of Conformity.....................................................................................14

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 4 of 16
1 Models available
Order - No. Measuring
value
Electrical
Output
Delay time Operating
Voltage
Connection
5.4103.20.041 Precipitation
intensity 4 … 20mA 180 seconds 24V AC/DC
±15% Cable glandP
5.4103.20.741 Precipitation
intensity 4 … 20mA 180 seconds 24V AC/DC
±15% 7- pole plug
connection
5.4103.20.641 Precipitation
intensity 4 ... 20mA 50 seconds 24V AC/DC
±15% Cable glandP
5.4103.26.041
Precipitation
intensity 4 … 20mA 180 seconds
24V AC/DC
±15% Cable glandS
P) Cable gland plastic S) One cable gland stainless steel
2 Application
The precipitation sensor serves as measuring instrument for the determination of the
instantaneous precipitation intensities (mm precipitation / min.). By integration of the
precipitation intensities, the precipitation quantity can be calculated, as well. Control- and
warning signals can be derived from the precipitation intensity.
The measuring signal is output as intensity-dependent analogue output value. The dimension
of the measurement value output is divided into 4 linear characteristic segments, which show a
tenth of the slope of the more sensitive segment.
Thus, it is possible to represent an intensity range from approx. 0,001mm/min. (light drizzle) up
to 10mm/min. (extremely heavy rain) with reasonable resolution (quasi-logarithmic output).
3 Construction and Mode of Operation
Precipitation in the form of drizzle, rain, snow, or hail falls through a light band, induced by light
diodes, and lead to shadowing effects on the receiving side. The sent light is pulse-modulated.
From the extent of shading along with the duration of falling through a factor is calculated that
gives the information if there is a precipitation incident or not.
Heating
The instrument is equipped with a heating system for extreme weather condition. This avoids
ice and snow forming on the housing surface. In addition, the surface retains a temperature of
>0° by means of a regulated heating. The heating is always active, the control temperature is
approx. 8°C.
At the end of the precipitation the analogue output goes in one time of 180sec. (5.4103.2x.041,
5.4103.20.741) or 50sec. (5.4103.20.641) to 4mA. If the precipitation starts, the analog output
rises again to the measured value.
Housing
The housing consists of polycarbonate, the support of stainless steel.
A special coating serves for reducing measurement errors which might arise by drop formation
at the housing in the range of the measured distance. This coating must not be removed.

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 5 of 16
4 Installation
Please Note:
The hydrophilic coating must not be damaged. The electrical connection is to be
carried out by experts only. Please open the instrument only with dry ambient
conditions. Do not damage the exposed electronics!
Remark:
In order to achieve an optimal electro-magnetic immunity (> 20V/m) please use shielded
cable.
4.1 Mechanical Mounting
Note:
When mounting and aligning, take into
account that direct sunlight on the receiving
diodes can cause the sensor to malfunction.
When using several precipitation sensors in
parallel operation, the distance between the
mast must be greater than 1.5m.
When using sensors of other manufacturers
with infrared measuring technology, it must
be excluded that the receiving diodes of the
precipitation sensor are disturbed. This can
be realized e.g. by appropriate alignment of
the sensors.
5.4103.10.xxx
The operating position of the precipitation
monitor is horizontal.
The mounting system of the instrument is
designed for attachment to a mast. When
mounting make sure, that the precipitation
can easily reach the sensor field, and that
the instrument, while operating, is not
exposed to strong vibrations or shocks.
The pictured tube is not included in delivery.
Area of the
coating
receiving diodes

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 6 of 16
4.2 Electrical Mounting for Precipitation Sensor with Cable Gland
For: 5.4103.2x.041, 5.4103.20.641 see circuit diagram in chapter 4.
Process:
- Remove 5 screws at the bottom side of the precipitation monitor.
- Remove upper part (cover). The connecting terminals are the freely accessible.
- Insert a respective prepared cable from the bottom through the cable glands situated in
the housing bottom, and connect it to the connecting terminals and shield connector,
acc. to circuit diagram.
- Secure cable by cable glands.
- Put on the upper part again and screw it evenly and tightly to the bottom.
Attention:
The fixing screws for the cover must be srewed down with a torsional of 1Nm to 2Nm.

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 7 of 16
4.3 Electrical Mounting for Precipitation Sensor with Plug
Connection
For: 5.4103.20.741, see circuit diagram in chapter 5.
4.3.1 Plug Mounting
Applies only to instruments with connection „plug“.
Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp
Cable connection: without cable shield
1. Stringing parts on cable acc. to plan given above.
2. Stripping cable sheath 20mm.
3. Cutting uncovered shield 20mm.
4. Stripping wire 5mm.
5. Soldering wire to the insert.
6. Positioning shield in cable clamp.
7. Screwing-on cable clamp.
8. Assembling remaining parts acc. to upper plan.
9. Tightening pull-relief of cable by screw-wrench (SW16
und 17).
Cable clamp
Cable sheath
Wire

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 8 of 16
4.4 Connecting Diagram
Order-No.
5.4103.20.041
5.4103.20.641
5.4103.26.041
Clamp connection
Note:
The 5.4103.20.641 has a bridge rectifier at the input of the power supply
This means, that the power supply "-" does not have the same potential
as output "-". Power supply "-" and output "-" must not be connected.
All other variants have half-wave rectification at the input of the power
supply. There is the power supply "-" and has the same potential as
output "-".

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 9 of 16
Remark:
The cable shield must only be connected on the side of the power supply.
5 Taking into Operation
After the electrical connection has been established, and the case has been screwed, the
operating voltage can be switched on. The dimension of the measurement value output is
reset when the supply voltage is switched on.
6 Maintenance
The device is maintenance free.
Cleaning:
The pollution and the pollution level is dependent on the location. Therefore, we recommend
the unit be checked at appropriate intervals and cleaned if necessary.
For the cleaning should use a damp cloth without chemical cleaning agents are used.
Remark:
The housing is coated in the front section and in the sensor area. This coating must not be
damaged.
We recommend to clean (rinse) the instrument only with water, and to blot it with a soft cloth, if
necessary. Please take care that no water gets into the instrument. Excessive rubbing might
remove the coating.
Events can, possibly, be activated with the cleaning work; they should be considered then with
the evaluation / further processing.
Order-No.
5.4103.20.741
Plug connection
View on the soldering
side of the counter
plug.
1
2
3
4
5
6
7

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 10 of 16
We recommend the threads of the plugs with a suitable corrosion inhibitors to protect against
corrosion.
7 Technical Data
Measuring Value
Precipitation intensity (mm / min)
Output Constant current, depending on measuring value, between
4.0mA and 20.0mA
Measuring range, Output,
Transfer function Measuring range Output Function1)
Segment 1 0 ….... 0.01mm / min = 4.0 ….. 8.0mA 0,0025 *x -0,01
Segment 2
0.01 …0.1mm / min
= 8.0 … 12.0mA
0,0225 *x -0,17
Segment 3
0.1 …. 1.0mm / min
= 12,0 …16.0mA
0,225 *x -2,6
Segment 4
1.0 ... 10.0mm / min
= 16.0 …20.0mA
2,25 *x -35
max. load 400Ohm
Active sensor surface 25cm²
Minimum drop size 0,2mm
Operating voltage 24 V AC/DC ±15%
Operating current
approx. 350mA @ 20°C ambient temperature
max. approx. 1A
Heating
Control temperature
Hysteresis
Power
Two-level-controller.
approx. 8°C.
0,1K.
Max. 1A @ 25V.
Ambient temperature -30 ... +60°C
Protection IP 65 acc. to DIN 40050
Weight 0.4kg
Connection See model
1)Function for calculation:
Depending on the segment, where the measured current fits in, the respective function must
be applied, wherein for “x” the measured value in mA is entered.

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 11 of 16
8 Dimension diagram
5.4103.20.041
5.4103.20.641
5.4103.26.041
5.4103.20.741

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 12 of 16
9 Accessories (Optional)
Power Supply Unit 9.3388.00.002 The power supply unit provides for the
current supply of the Precipitation
Sensor. It supplies the necessary
operation voltage for the electronics
and the heating.
Primary : 230V / 50Hz
Secondary : 24V AC / 25VA
Housing : synthetic
Protection : IP 65 acc. to
DIN 40050
Dimensions : 107 x 125 x 100mm
Weight : 1,2kg

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 13 of 16
10 EC-Declaration of Conformity
Manufacturer: Adolf Thies GmbH & Co. KG
Hauptstraße 76
37083 Göttingen, Germany
http://www.thiesclima.com
Product: Precipitation Transmitter Doc. Nr. 902-45218_CE
Article Overview:
5.4103.10.000 5.4103.10.012 5.4103.10.112 5.4103.10.700 5.4103.11.000 5.4103.20.041 5.4103.20.741 5.4103.21.021 5.4103.26.041 5.4103.30.000
5.4103.30.700 5.4103.31.000 5.4103.32.000
2014/30/EU 26.02.2014
2017/2102/EU 15.11.2017
2012/19/EU 13.08.2012
2018/1139/EU 04.07.2018
The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards:
2019-11
2011-09
2020-03
2019-05
Göttingen, 19.10.2023
General Manager - Dr. Christoph Peper
Development Manager - ppa. Jörg Petereit
This declaration of conformity is issued under the sole responsibility of the manufacturer.
DIRECTIVE2014/30/EUOF THEEUROPEANPARLIAMENT ANDOFTHECOUNCIL of 26 February 2014 on the harmonisation of the laws of
the Member States relating to electromagnetic compatibility.
DIN EN IEC 63000
DIN EN61000-6-3:2007 +
A1:2011
DIN EN 61010-1
This declaration certificates the compliance with the mentioned directives, however does not include anywarranty of characteristics.
Please payattention to the security advises of the provided instructions for use.
The indicated products correspond to the essential requirement of the following European Directives and Regulations:
DIRECTIVE2012/19/EU OF THEEUROPEANPARLIAMENT AND OFTHECOUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE).
Regulation (EU) 2018/1139 of the European Parliament and of the Council of 4 July 2018 on common rules in the field of civil aviation
and establishing a European Union Aviation Safety Agency.
DIRECTIVE(EU) 2017/2102 of the European Parliament and of the Council of November 15, 2017 amending Directive 2011/65 / EU on
the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Electromagnetic compatibility Immunity for industrial environment
Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements
Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous
substances.
DIN EN IEC 61000-6-2
Electromagnetic compatibility (EMC). Generic standards. Emission standard for residential, commercial and light-industrial
environments

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 14 of 16
11 UK-CA-Declaration of Conformity
Manufacturer: Adolf Thies GmbH & Co. KG
Hauptstraße 76
37083 Göttingen, Germany
http://www.thiesclima.com
Product: Precipitation Transmitter Doc. Nr. 902-45218_CA
Article Overview:
5.4103.10.000 5.4103.10.012 5.4103.10.112 5.4103.10.700 5.4103.11.000 5.4103.20.041 5.4103.20.741 5.4103.21.021 5.4103.26.041 5.4103.30.000
5.4103.30.700 5.4103.31.000 5.4103.32.000
1091 08.12.2016
01.01.2021
01.01.2021
2018/1139/EU 04.07.2018
The indicated products comply with the regulations of the directives. This is proved bythe compliance with the following standards:
25.02.2019
30.03.2021
31.03.2017
10.12.2018
Göttingen, 19.10.2023
Legally binding signature: Legally binding signature:
General Manager - Dr. Christoph Peper
Development Manager - ppa. Jörg Petereit
Regulation (EU) 2018/1139 of the European Parliament and of the Council of 4 July2018 on common rules in the field of civil
aviation and establishing a European Union Aviation Safety Agency.
The Electromagnetic Compatibility Regulations 2016
The indicated products correspond to the essential requirement of the following Directives and Regulations:
BS EN IEC 63000
This declaration of conformity is issued under the sole responsibility of the manufacturer.
RoHS Regulations
2012
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
3113
Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous
substances
Regulations: waste electrical and electronic equipment (WEEE)
BS EN IEC 61000-6-2
Electromagnetic compatibility (EMC). Generic standards. Immunity standard for industrial environments
BS EN IEC 61000-6-3
Electromagnetic compatibility (EMC). Generic standards. Emission standard for equipment in residential environments
BS EN 61010-1+A1
Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements
Please payattention to the security advises of the provided instructions for use.
This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics.

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 15 of 16

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany 021335/10/23
Phone +49 551 79001-0 · Fax +49 551 79001-65 · inf[email protected] ·www.thiesclima.com Page 16 of 16
Please contact us for your system requirements.
We advise you
gladly.
ADOLF THIES GMBH & CO. KG
Meteorology and environmental metrology
Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001
-0 · Fax +49 551 79001-65
www.thiesclima.com
Other manuals for 5.4103.20.041
1
This manual suits for next models
3
Table of contents