Control Box Operation - Manual Operation
1. Power up the control box by holding
the “Front Hopper” “OPEN” and
“CLOSE” buttons on the control box
simultaneously for 3 seconds or until
the green control box light comes on
to indicate the control box is
activated.
2. Select button to perform the required
operations.
3. Power off Control Box when finished.
Push and hold the Front Hopper
“Open” and “Close” buttons on the
control box simultaneously for 3 seconds or until control box light goes off.)
Programming Remote to Easy Flow Control Box
1. Power up the control box by holding the “Front
Hopper”“OPEN” and “CLOSE” buttons on the
control box simultaneously for 3 seconds or until
the green control box light comes on to indicate
the control box is activated.
2. Open flip style lid on the remote and observe
the flashing light.
3. Press the “Mode” button to select “Front
Hopper” Mode. (First two lights flashing)
4. Repeat steps 1 and 2 for each remote to be
programmed. Up to four remotes can be
programmed. Have all remotes ready for step 5 and 6.
5. Press and hold the “Work Light” button on the
control box for 8 seconds or until the green light
starts flashing red.
6. If one remote is being programmed press the
“On/Open” on the remote 4 times. If more remotes
are to be programmed, use the
following table for the # of
“On/Open” presses for each
remote.
7. Close the flip style lid to power
down the remote. The remote
will time out after a period of
inactivity regardless if the flip lid
is open.
Table for programming multiple
remotes to control box
1st Remote
2nd Remote
3rd Remote
4th Remote
1 Remote
4
2 Remotes
1
3
3 Remotes
1
1
2
4 Remotes
1
1
1
1
Number of remotes to program
Number of ON/OPEN presses
Control Box Light
Programming/Work
Light Button
MODE Selection
Button
MODE Lights
Control Box Light
Programming/Work
Light Button
OPEN Button
CLOSE Button
402.435.4249 www.THUNDERSTONEMFG.com Page 3
Control Box Operation, Wireless Operation
1. Power up Control Box using transmitter. Open transmitter and Push “MODE” button to select the
“Front Hopper” Mode (First two lights flashing).
2. Push and hold the “On/Open” and “Off/Closed” buttons on the transmitter simultaneously for 3
seconds or until control box light comes on to indicate the control box is activated.
3. Select button to perform the required operations for the front hopper.
4. To use the rear hopper, push “MODE” button to select “Rear Hopper”(First three lights flashing).
5. Select button to perform the required operations for the rear hopper.
6. Power off Control Box when finished. Push “MODE” button to select “Front Hopper” Mode (First two
lights flashing). Push and hold the “ON/OPEN” and “OFF/CLOSED” buttons on the transmitter
simultaneously for 3 seconds or until control box light goes off.
EZ Flow Cylinder Disconnect *Emergency Operation*(if equipped)
1. Locate poppet valve buttons. (Fig A)
a. Top Button (1) is for front door
b. Bottom Button (2) is for rear door
2. Push & hold each button individually for approx. 15
secs or until system is depressurized.
3. When system has been depressurized, unlatch quick
release pin & remove. (Fig B) Repeat this step on all
cylinders as needed.
4. Door(s) are now disconnected from the cylinders
and can now be operated manually.
MODE Selection
Button
MODE Lights
ON/OPEN Button
OFF/CLOSED
Button
Poppet Valves
(1)
(2)
Figure A
Figure B

Popular Truck manuals by other brands

DAF LF45 Series manual

DAF

DAF LF45 Series manual

UniCarriers PLL Series Instruction handbook

UniCarriers

UniCarriers PLL Series Instruction handbook

Vestil AWST-3672-PU manual

Vestil

Vestil AWST-3672-PU manual

Volvo A60H manual

Volvo

Volvo A60H manual

AluTeam BR 13x-3 Assembly instructions

AluTeam

AluTeam BR 13x-3 Assembly instructions

Peterbilt 220 Operator's manual

Peterbilt

Peterbilt 220 Operator's manual

Komatsu 930E-4SE Operation & maintenance manual

Komatsu

Komatsu 930E-4SE Operation & maintenance manual

freightliner PT126SLP Maintenance manual

freightliner

freightliner PT126SLP Maintenance manual

GMC 2010 T-Series owner's manual

GMC

GMC 2010 T-Series owner's manual

RWM Casters RWM CONVERTIBLE HAND TRUCK Assembly instructions

RWM Casters

RWM Casters RWM CONVERTIBLE HAND TRUCK Assembly instructions

Labrie Optimizer Maintenance manual

Labrie

Labrie Optimizer Maintenance manual

Kalmar DCE80-100E Technical handbook

Kalmar

Kalmar DCE80-100E Technical handbook

Komatsu 930E-2 Shop Manual

Komatsu

Komatsu 930E-2 Shop Manual

Volvo L90E Operator's manual

Volvo

Volvo L90E Operator's manual

Rail-Ability SUPER BOSS RAIL OPERATIONS & EMERGENCY RECOVERY PROCEDURES

Rail-Ability

Rail-Ability SUPER BOSS RAIL OPERATIONS & EMERGENCY RECOVERY PROCEDURES

Sealey Premier CST989HD quick start guide

Sealey

Sealey Premier CST989HD quick start guide

Pierce Pumper Operation & maintenance manual

Pierce

Pierce Pumper Operation & maintenance manual

Komatsu HM300-2R brochure

Komatsu

Komatsu HM300-2R brochure

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.