4. Operation
Use adjuster dial to set desired temperature.
Blue LED is lit when temperature is below
desired value, indicating that the thermostat is
calling for heat from the boiler. Once the room
reaches the desired temperature the LED turns
off and the TRT030 ceases to call for heat from
the boiler.
The temperature swing can be adjusted between
1°C and 0.5°C by selecting a jumper found on
the rear of the unit (see Fig 2).
We suggest using the 0.5ºC position unless the
boiler turns on and off too rapidly.
PID can also be selected on or off using a
jumper on the rear of the unit (see Fig 2).
To reinstall the unit on the wall plate first
ensure the wall plate retaining screws are
loosened enough to clear the TRT030 body then
engage the top of the TRT030 onto the wall
plate retaining tabs (see Fig 4), and push firmly
downwards and then upwards. There will be
some resistance from the terminals. Once in
place, secure with the retaining screws.
Restore mains to the unit after checking all
system wiring is complete.
Remove wall plate from unit, by undoing
retaining screws (see Fig 2), and pivoting the
bottom of the unit outwards. The TRT030 can
then be lifted off.
Pass the incoming wires through the opening in
wall plate, and fix wall plate securely to the wall,
using the screws provided(and wall plugs if
necessary) provided. The screws which secure the
product to the wall plate should be at the
bottom (see Fig 2).
Allow sufficient excess cable to wire up the unit,
but not too much to make it difficult to close
the unit to the wall plate.
Connect the conductors to the relevant terminals,
according to the wiring diagram on the wall
plate (or Fig. 3 below). Ensure that the curved
brass washer grips the conductor.
N
NO N L
L
Fig. 3
Wiring
Diagram
NO N L
Fig. 4
Back Plate Removed
Alternative
fixing holes
Retaining
tabs
Mount the wall plate in this
configuration only
Product retaining
screws
Terminal for maintaining
continuity of earth
This unit is double insulated, and hence does not
need connection to earth. If earth continuity is
required, please use earth terminal on wall plate.
5. Specifications
Current rating: 10 (2) A
Voltage: 220-240V, 50HZ
Switch type: Single pole, single throw
(SPST)
Operating
temperature range: 0 to 50°C
Set temperature
range: 5 to 30°C
Complies with: BS EN 60730
Conforms to
directives: 73-23-EEC, 89-336-EEC
Temperature
swing: 1°C or 0.5°C
Micro
disconnection: Type 1.B control action
This can help in reducing temperature over-shoot.
We suggest using the PID on position.
To clean use a clean dry cloth only. Do not use
any liquid cleaners.