For a product brochure please contact:
Timeguard Ltd. Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020-8452-1112
A Group company
67-058-330
HELPLINE
020-8450-0515
For assistance with the product please contact:-
3 Year Guarantee
In the unlikely event of this product becoming
faulty due to defective material or manufacture
within 3 years of the date of purchase, please
return it to your supplier in the first year with proof
of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year
telephone the helpline on
020 8450 0515.
5. Specifications
Current rating: 16 (4) A
Voltage: 230V, 50HZ
Switch type: Single pole, double throw
(SPDT)
Operating
temperature range: 0 to 55°C
Set temperature
range: 40 to 80°C
Complies with: BS EN 60730
Conforms to
directives: 73-23-EEC, 89-336-EEC
Always isolate the mains supply before
starting work.
Incoming cable should be 1.5mmsq.
Remove cover from unit by unscrewing cover
retaining screw, and easing off the temperature
adjusting knob.
Thread incoming wire though the cable gland.
Allow sufficient excess cable to wire up the
unit, but not too much to make it difficult to
close the cover on the unit.
Connect the conductors to the relevant
terminals, according to the wiring diagram.
Ensure that the brass washer grips the conductor.
Pull some of the excess cable back through the
gland and then tighten the gland to trap the
cable and give good strain relief.
Replace the cover and the adjustment knob.
Adjust the length of the spring wire, and use it
to strap the TRT044 to the hot water cylinder.
Restore mains to the unit after checking all
system wiring is complete.
NL
Cylinder/Pipe
Thermostat
Cat. No. TRT044
Operating & Installation Instructions
2. Siting
The TRT044 is designed to be surface mounted
onto the domestic hot water cylinder. For
cylinders with an insulating foam covering, a
section of foam must be removed so the back
of the thermostat is in direct contact with the
metal body of the tank.
The TRT044 should be mounted between a
quarter and third of the way up from the base
of the tank in a position that gives good access
to the dial.
3. Installation
This product must be installed in accordance
with the appropriate building and wiring
regulations.
In all cases if there is a doubt as to how to
proceed with an installation consult a qualified
electrician, your local authority’s building
control department or the Timeguard helpline
(020 8450 0515).
Contents
TRT044 cylinder thermostat
TRT044 instruction leaflet
Spring wire
Wire strap
4. Operation
Use adjuster dial to set desired temperature.
For vulnerable people it may be advisable to
reduce the setting to as low as 50ºC bearing in
mind the outlet water temperature will be
somewhat higher than this due to the
temperature stratification in the tank.
To clean use a clean dry cloth only. Do not use
any liquid cleaners.
C12
TRT044
Cylinderstat
Fig. 2
Wiring Diagram
Terminals C an 2 make on temperature rise.
Terminals C an 1 make on temperature fall.
TRT044_135x90_Instructions.indd 2TRT044_135x90_Instructions.indd 2 15/6/09 15:15:5815/6/09 15:15:58