SX1000 Hot Towel Cabinet Operation Manual
Congratulations on your purchase of the TISPRO SX1000 Hot Towel Cabinet.
Please read the instructions and safety tips before use. Your Hot Towel Cabinet comes
with a one-year limited warranty. If for any reason you need service, please call 800-520-6000.
Product Specification
Towel Warmer
Voltage: Single phase, 110V/60Hz
Power: 200W
Temperature: 158°F – 176°F
Safety device: Thermal fuse
Insulation: Glass wool
Inside size: 14 1/2”W x 7 1/2”D x 9 1/2”H
Outer size: 17 3/4”W x 10 1/2”D x 14”H
UV Bulb
Bulb type: E17 (17mm diameter)
Power: 3W
Radiation type: UV-C, wave length 240nm
Names of all parts
Before Operation
• Be sure to remove all packing material before use.
• Place the unit on a well ventilated, flat, sturdy surface away from heat sources. The unit
should not be used in the immediate vicinity of water (such as bathtub, washbowls,
etc.) where the likelihood of immersion may occur.
• Plug cord into a 110V power outlet.
• Remove the wire basket and set aside.
Operation
1. Run towels briefly under water.
2. Wring out excess water from the towels. Towels should be damp, not soaked. You
may need to wring out several times.
3. Fold or roll towel and place towels into the wire basket. Do not overload the wire
basket or directly place towels into the towel warmer.
4. Insert the basket with towels into towel warmer.
5. Close the door firmly.
6. Turn on the HEAT switch and indicator light will go on. In about 10 minutes, the
temperature inside the cabinet will heat up to approximately 200°F and the indicator
light will go off. When the temperature drops in cabinet the light will go back on. The
unit will automatically heat up again, and continue to cycle like this.
7. Turn on the UV switch. The UV indication lamp will remain illuminated.
Maintenance
1. Turn OFF the unit.
2. Unplug the cord from the outlet.
3. Wait for contents to cool before handling. Contents may be hot. Remove the wire
basket and towels. Set the wire basket aside to dry.
4. With a soft cloth, wipe down the internal surfaces. Do not use harsh chemicals or
abrasives. To clean exterior, use a soft cloth and mild soap.
5. Pull the drip tray forward and empty contents. Set the drip tray aside to dry.
Replacing the UV Bulb
1. Turn OFF the unit.
2. Unplug the cord from the outlet.
3. Screw off the faulted UV bulb.
4. Screw on a new E17/3W UV bulb, recommended wave length 240nm (UVC).