Topcon FC-2000 User manual

Thank you for purchasing the TOPCON Data Collector FC-2000.
For superior product performance, please read this instruction manual carefully and keep it in a convenient place for future reference.
GENERAL HANDLING PRECAUTIONS
•Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.
•Always make sure instrument is dry before putting it in the soft case. Never store a damp instrument.
•Do not leave the instrument under strong sunlight for a long time. It may cause the instrument to malfunction.
•When waterproofness is necessary, close all the caps securely. However, the serial connector COM1 has a waterproof structure, so it will remain
waterproof even if its cap is not closed.
DISPLAY FOR SAFE USE
In order to ensure the safe use of this product, prevent any danger to the operator or others, or damage to property, important warnings are placed on the
product and inserted in the instruction manual. We recommend that you become familiar with the meaning of these Warnings and Cautions before con-
tinuing.
INSTRUCTION MANUAL
DATA COLLECTOR
• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to equipment and structure
or furnishings.
Display Meaning
WARNING
Ignoring or disregard of this display may
lead to the danger of death or serious injury.
CAUTION
Ignoring or disregard of this display may
lead to personal injury or physical damage.
WARNING
• The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
• Battery can cause outbreak of fire.
Do not use any other type of charger other than the one specified.
• Risk of fire or electric shock.
Do not use any power voltage except the one given on manufacturers instructions.
CAUTION
• Do not allow skin or clothing to come into contact with acid from the batter-
ies, if this does occur then wash off with copious amounts of water and seek
medical advice.
• Do not connect or disconnect equipment with wet hands, you are at risk of
electric shocks if you do!
• Do not touch the charger, AC-DC converter or heating part of the instrument
for a long period while charging the battery.
There is a risk of low-temperature burn.
Exceptions from Responsibility
1The user of this product is expected to follow all operating instructions and make periodic checks of the product’s performance.
2The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
3The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
4The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an unusable product.
5The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than explained in the user manual.
6The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products.
NOMENCLATURE AND FUNCTIONS
SAFETY CAUTIONS
WARNING
• There is a risk of fire, electric shock or physical harm if you attempt to disas-
semble or repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only!
• May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.
• High temperature may cause fire.
Do not cover the charger while it is charging.
• Risk of fire or electric shock.
Do not use a wet battery or charger.
• Battery can cause explosion or injury.
Do not dispose in fire or heat.
• To reduce the risk of hazards, use only CSA/UL certified power supply cord set,
cord is Type SPT-2 or heavier, minimum No.18 AWG copper, one end is pro-
vided with a moulded-on male attachment plug cap (with a specified NEMA
configuration), and the other end is provided with a moulded-on female connec-
tor body (with a specified IEC non-industrial type configuration).
FC-2000
Function key
Power key
Hook for neckstrap
Microphone
Speaker
Battery cover
Hard reset switch
Inside the cover
Hook for handstrap
AC adapter, external
battery Connector
Serial COM2
(Total Station)
Serial
COM1
USB Connector
(Mini-B)
CF slot
CF slot cover
Screw
To tighten or loosen the
screw, use a coin.
CF card
CF card eject button
To eject the CF card, press the button.
Handstrap
Screw
To tighten or loosen the
screw, use a coin.
Display and Touch screen
Hook for handstrap
Hook for tripod
CONNECTORS
Serial COM1 No.1 DCD (IN)
No.2 RXD (IN)
No.3 TXD (OUT)
No.4 DTR (OUT)
No.5 GND
No.6 DSR (IN)
No.7 RTS (OUT)
No.8 CTS (IN)
No.9 RI (IN)
No.1 GND
No.2 CTS (IN)
No.3 TXD (OUT)
No.4 RXD (IN)
No.5 RTS (OUT)
No.6 VDD (IN)
Serial COM2
(Total Station)
FC-2000
Enter key
Escape key
Cursor keys
TAB key
1 FC-2000 Instrument........................................... 1set
2 BT-62Q Battery ................................................. 2pcs.
3 Battery charger BC-30....................................... 1pc.
4 AC-DC converter AD-9B or AD-7C*1)............ 1pc.
5 Instruction manual ............................................. 1vol.
6 Handstrap........................................................... 1pc.
7 Neckstrap ........................................................... 1pc.
8 Soft case............................................................. 1pc.
9 Stylus pen .......................................................... 1pc.
10 Display protection sheet .................................... 5pcs.
11 Interface cable F-25 ........................................... 1pc.
STANDARD PACKAGE COMPONENTS
Upon opening, make sure that all the followings are
included.
*1) AD-9B is for AC 120V use, AD-7C is for AC 230V use.
2) Components are different by the markets.
Shortcut Keys
Backlight
ON/OFF
[Func]+[ . ]
Ctrl Key [Func]+[S.P]
Soft Reset
[Shift]
+
[Func]
+
[ESC]
Push those keys
up for at least
2 seconds.
Windows Start
Menu
[Func]+[ / ]
Shortcut
Commands
Press [Alt]
+
Tap on an item
is the same as a
right click on a
mouse. A menu is
displayed contain-
ing commands spe-
cific to the item.
Windows CE
Task Manager
Press [Alt]
+
[TAB]
to switch to
another active pro-
gram or to END
Task on
running pro-
gram(s).
USB Connector
(Type Mini-B) No.1 VDD
No.2 V-
No.3 V+
No.4 NC
No.5 GND
Charge LED
Stylus pen*
CF Card Slot
In the Suspend (power OFF) and Standby modes, this instrument
does not supply power to the CF card.
If you switch to the Standby mode while a Bluetooth™card or
some other I/O communication card is in use, the link will be cut.
Turn off the Standby mode before using these cards.
*Insert direction of stylus pen
Insert the stylus pen so that the clip is fac-
ing outwards.
Clip
Cap
Cap

Microprocessor :XScale PXA 255
Processor speed :400MHz
Operating system :Microsoft Windows CE.NET 4.2
Memory :64MB RAM
64MB/128MB flash disc (internal)
Display :320x240 QVGA (color)
3.5 inch TFT Transflective type
Illumination :LED back light
Key board :56 key keyboard with separate alpha and numeric
Pen touch screen :Resistive touch screen/passive Pen digitization
Interface :RS-232C serial (D-sub 9)
RS-232C serial (6 pin)
USB(1.1) (Mini-B)
CompactFlash : Type I / ll
External power :12V 1A (max)
Audio :Sealed Speaker (mono) Sealed Microphone
Durability :IP66 (Based on the standard IEC 60529) *1)
*1) With the caps
Operation
Temperature
:-20°C to +50°C (-4°F to +122°F)
Storage
Temperature
:-30°C to +60°C (-22°F to +140°F)
Protection against
shock
:Designed to protect falling on the hard surface from 1.0m above the ground.
EMC :CE, FCC
Battery BT-62Q :Li-ion rechargeable Battery 7.4V 2200mAh
(This battery does not contain mercury.)
Operating time :20 hours (Typical use )
45 hours (With no display light, no touch)
Charging time :Approx. 3 hours with BC-30
Approx. 5 hours with AD-9B/7C
Dimensions :255x130x61(mm)
Weight :0.8kg(with battery)
Battery Installation
1 Remove the handstrap from the FC-2000.
2 Using a coin, loosen the screw on the battery cover.
3 Remove the battery cover.
4 Install the battery pack.
5 Using a coin, install the battery cover. Tighten the screw
firmly.
SPECIFICATIONS Always clean the instrument after use.
Use a clean cloth moistened with neutral detergent or water.
Never use an abrasive cleaner, ether, thinner benzene, or other solvents.
Always make sure the instrument is completely dry before storing. Dry any moisture with a soft,
clean cloth.
FC-2000 64850 90052
TRANSMITTION DATA TO THE PC
1 Install ActiveSync in your PC (if it is not already installed).
2 Connect the FC-2000 to your PC with an interface cable F-25 as shown below.
3 The FC-2000 will give the prompt, “Connecting to Host”.
4 The PC will prompt you to set up a partnership or set up as a guest.
5 Select the [NO] key to setting up as a guest.
6 Press the [Next] key.
Once a connection has been established, the ActiveSync window will appear on your PC.
7 Click the [Explorer] icon. You will then see the FC-2000 file structure.
PC
Interface(USB) cable F-25
FC-2000
USB port
(Type Mini-B)
USB port
(Type A)
Reference software for Connectivity
See the WEB page as follows.
http://www.microsoft.com/windowsmobile/
PREPARATION FOR USE
There are two ways to charge the battery as follows.
Battery Charging (Using BC-30)
1 Install the battery on the BC-30.
2 Plug the power cord in an outlet.(AC-120V or 230V) Charging is
completed after approximately 3 hours.
The Power LED of BC-30;
Red ON : Power is on.
The Charge LED of BC-30 will indicate charging status;
On Solid : Wait for charging.
Red ON : Charging.
On Solid : Charging completed.
Red Flashing : Charging error.
Battery Charging (Using AD-9B/7C)
1 After installing the battery, plug the connector of AD-9B/7C in the FC-
2000.
2 Plug the AD-9B/7C in an outlet. Then the run charge LED will light.
Charging is completed after approximately 5 hours.
The display can be turned on or off by the power key.
The Charge LED of FC-2000 will indicate charging status;
Red ON : Charging.
Green ON : Charging completed.
Red Flashing : Charging error.
Battery
Adjusting Touch Screen
1 Tap [Start], [Setting], [Control Panel], [Stylus], [Calibration], [Recalibrate] or turn on the instrument after hard-reset.
2 Using a stylus pen, touch the center of the targets.
3 After touching all targets (5 points), press [ENT] key, or tap the display.
(Use an accessory stylus pen to touch a screen. Do not use neither a ball-point pen nor pencil.)
Stylus pen
Targets
Touch Screen
Note
1)Recharging should take place in a room with an ambient temperature range of +10°C to +40°C (+50°F to +104°F).
2)The battery source will discharge when stored and should be checked before using with instrument .
3)Be sure to charge a stored battery source every 15 days and store in a place at 30°C and below when it will not
used for a long period. If you allow the battery to be completely discharged, it will have an effect on the overall
performance for proper charging in the future.
4)The charger may develop heat while charging, there is no problem of it.
5)If charging is done at high temperature, charging time of the battery may take longer.
Interface Cable
BC-30
BT-62Q
AD-9B/7C
Connector
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
TOPCON POSITIONING SYSTEMS, INC.
7400 National Drive, Livermore, CA 94551, U.S.A.
Phone: 925-245-8300 Fax: 925-245-8599 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON EUROPE B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com
TOPCON DEUTSCHLAND G.m.b.H.
Giesserallee 31, 47877 Willich, GERMANY
www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France.
TOPCON ESPAÑA S.A.
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern, Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
TOPCON SCANDINAVIA A. B.
Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249
TOPCON (GREAT BRITAIN)LTD.
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381
Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
Unit 18, 4 Avenue of Americas Newington NSW 2127, Australia
Phone: 02-8748-8777 Fax: 02-9647-2926 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 02-440-1152~7 Fax: 02-440-1158
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra,
Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA
Phone: 03-42701068 Fax: 03-42704508
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2-4/F Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road,
Shatin, N.T., Hong Kong
Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
TOPCON CORPORATION BEIJING OFFICE
Building A No.9, Kangding Street
Beijing Economic Technological Development Area, Beijing, China 100176
Phone: 10-6780-2799 Fax: 10-6780-2790
TOPCON CORPORATION BEIRUT OFFICE
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON.
Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
C/O Atlas Medical FZCO., P. O. Box 54304, C-25, Dubai Airport Free Zone,UAE
Phone: 971-4-2995900 Fax: 971-4-2995901
IRELAND OFFICE
Unit 69 Western Parkway Business Center
Phone: 01460-0021 Fax: 01460-0129
Lower Ballymount Road, Dublin 12, Lreland
Replacement of Battery
• When the battery is replaced, the data recorded in memory will be lost.
To protect the data, first execute “RAM Data Backup”, then replace the battery.
Note: The instrument may develop heat while charging, there is no problem of it.
FCC conditions
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Bluetooth™ and the Bluetooth™ logos are trademarks owned by Bluetooth™
SIG, Inc., USA.
If your device had not recharged during several days, the battery will be running down, and you would lose all of data on the
device other than that in the "CF Card (internal CF card)".
In addition, you might perform hardware-reset by the hardware problem or software problem. In this case, you would lose all
data same as the above.
You can use Backup function of FC-2000 in order to evade such kind of uneasiness. Your data will be restored to latest con-
dition* automatically when rebooting by using the Backup function.
The Backup function saves all data files of RAM (except for OS files), registry file and additionally installed programs into
named "Backup" folder in the "CF Card".
Execute the Backup function
1Tap the icon "Start"-"Settings"-"Control Panel"-"System"-"Backup". You can see the "RAM" screen on Display.
2Tap the "RAM data backup" button. Backup function will start. Return to "RAM" screen automatically, when the data back up has
been completed.
3Tap the button "OK" on title bar. After that "RAM backup" screen will close automatically.
Set the Automatic Backup for every suspension
1On the "RAM Backup" Screen, please check it 'ON' "RAM data will be backed up before suspension".(Factory setting is 'OFF' as
default)
2Tap the button "OK" on title bar. After that, "RAM backup" screen will close automatically.
Set the restoration disabled after hard reset
1On the "RAM Backup" Screen, check it 'OFF' the "Data restoration after hard reset."
(Factory setting is 'ON' as default)
2Tap the button "OK" on title bar. After that, "RAM backup" screen will close automatically.
* Restoring former backed up data may be incomplete if you upgrade OS version.
* The conditions that you executed the backup function last.
* Backing up data may be incomplete if remaining capacity of "CF Card" is not enough.
Please make sure the remaining capacity of "CF Card" before proceeding to the data back up.
* Restoration will be impossible if you delete the "Backup" folder in the "CF Card".
RAM DATA BACKUP
STORAGE PRECAUTIONS
Power LED
Charge LED
Charge LED
Other Topcon Data Logger manuals