–1–
EN
Air Conditioner
INSTALLATION MANUAL
<4-way air discharge cassette type>
Air-Discharge Direction Kit
MODEL: TCB-BC1602UE
• Thank you for purchasing the “Air-Discharge Direction Kit” of TOSHIBA Air Conditioner. Before starting the installation
work, please read this manual carefully and install the product properly.
• As for the “Safety precaution”, please read the installation manual and the instruction manual for the 4-way air
discharge cassette type air conditioner (indoor unit) carefully, and also read the installation manual supplied with the
ceiling panel carefully.
• Please use this kit when controlling the air direction in 3-way or 2-way air flow depending on the installation location
status of the indoor unit.
1. Applicable models and Applications
2. Accessories (The following parts are attached.)
3. Installation methods
CAUTION
• Before installing thewind shield,change theair conditioner settings according tothe procedures described onthe back
of the page.
• Unless the setting is changed, the air blow temperature becomes low. This may cause the dew condensation.
MODEL Applicable model Application
TCB-BC1602UE SM56~SM160 · Controlling the blockage of 3-way or 2-way air flow.
MODEL Product name Dimensions (mm) Shape Q’ty
TCB-BC1602UE Wind shield
A 480×80×40 1
B 400×80×40 1
C 400×80×40 1
Packing 460×110×2 2
1-EN
+00EH99664801_10L_TCB-BC1602UE.book Page 1 Wednesday, April 30, 2008 4:31 PM
–2–
EN
Installing the wind shield(s) and packings
• Attach the wind shields to the air flow openings (made of styrene foam) of the indoor unit and place the packings on
them to block the air flow. (Refer to Figs. 1 to 3.)
• Put the packings bending along the edges of the indoor unit external surface without blocking the concaved portions of
the drain pans. (If the packings are not put bending along the edge of the indoor unit external surface, the dew
condensation may occur.) (Refer to Figs. 1 and 3.)
* The size adjustment is required for the packing which are attached on the wind shield C. Cut 40 mm to adjust its size in 420
mm x 110 mm.
Installing the indoor unit
• Install the indoor unit (Install the indoor unit following the
instructions described on the installation manual of the indoor
unit.)
• Block the air flow outlets following the air flow blocking pattern
shown in the table on the back page when controlling 3-way or
2-way air flow. Also refer the piping position shown in the table
on the back page. (Refer to Fig. 4 as for the detail of the
illustrations.)
Packing Wind shield (A, B, C) Drain pan
Indoor
unit
External
surface
Interior styrene foam Air flow outlet
Packing
Packing
Wind shield B
Wind shield A
Packing
(required to
cut 40 mm.)
Wind shield C
Drain piping
Refrigerant piping
Wind shield A
Putthepackingswithout
blocking the concaved
portions.
(Fig. 1)
(Fig. 3)
(Fig. 2)
Blockage portion
Refrigerant piping Drain piping
Air flow
(Fig. 4)
2-EN
+00EH99664801_10L_TCB-BC1602UE.book Page 2 Wednesday, April 30, 2008 4:31 PM
–3–
EN
Installing the indoor unit (Continued)
• The blockage portions of the air flow outlet are specified depending on the models. Do not specify the blockage of the
airflow outlet other than specified in the table below.
Changing the setting
• The setting is changed by using a wired remote controller. (For the setting methods, follow the change procedures
written on the next page.)
• Perform “Setting the louver lock (Louver position fixing)”.
CAUTION
When the ceiling is higher than the specification, the fan control is required. So, in that case, perform the “high ceiling
setting” other than the setting described above.
The setting should be performed according to the instructions described on the installation manual attached to the indoor
unit.
“Changing procedure”: Change the setting while the device stops.
(1) Push + + buttons simultaneously for more than 4 sec.
The unit No. displayed at first shows the indoor unit address of the header
unit in group control operation. The fan operation of the indoor unit (header
unit), selected at this time, is carried out.
(2) Every time when UNIT (Left button) ispushed,the indoor unit No. in
the group control operation are displayed in order.
The fan operation of the indoor unit, selected at this time, is carried out.
(3) Set the CODE No. by using the TEMP. / button.
(4) Set the setting data by pushing TIME / buttons for the TIME setting.
(5) Push the button. (The setting completes if the setting data are
displayed.)
When changing the setting of other indoor unit in the group control operation,
return to 2.
(6) Pushing the button enters the normal stop status.
3-way air flow ………
2-way air flow ………
3-way air
flow
Available for all models
Wind shield C
Wind shield A
Wind shield B
2-way air
flow
Available for all models
Available only for SM40-SM80.
Available only for SM110-SM160.
Available for all models Available for all models Available for all models
Wind shield A
Wind shield A
Wind shield B
Wind shield A
Wind shield C Wind shield C
Wind shield B
Limited models only
5
14 263
3-EN
+00EH99664801_10L_TCB-BC1602UE.book Page 3 Wednesday, April 30, 2008 4:31 PM
–4–
EN
Setting the louver lock (Louver position fixing)
• Fix the louver at the air flow blockage portions. (For the setting methods, follow the procedures below.)
(1) While stopping the operation, push the LOUVER (Right button) for more than 4 seconds.
The blinks.
(2) Push the UNIT (Left button) to select the indoor unit you desire to
set.
Every time you push the button, the Unit No. changes.
The fan of the selected indoor unit starts its operation and the louvers
swing.
(3) Push the TEMP. / buttons to display the louver No. with the wind
shield applied.
The selected louver starts to swing.
(4) Select the code 001 by pushing the TIME / buttons.
(5) Push the button to define the setting contents.
After the setting contents is defined, the mark lights. (Return to step
3if there are other two wind shields.)
(6) Push the button to exit the setting.
• “F1” is displayed in the CODE No. on the remote controller display.
This means that the 01 louver shown on the illustration is selected.
Confirming the installation
• After the installation completes, perform the trial run to confirm that no abnormality is found.
• For your future reference, please keep the installation manual on your side.
Unit No.
1-1
Unit No.
1-4
Unit No.
1-2
Unit No.
1-3
F1
F4
F2
F3
Louver fixing position code Louver No.
Electric parts box
Refrigerant piping
Drain piping
(Louver No. diagram)
4-EN
+00EH99664801_10L_TCB-BC1602UE.book Page 4 Wednesday, April 30, 2008 4:31 PM

Other Toshiba Air Conditioner manuals

Toshiba Carrier RAV-SP180KRT-UL User manual

Toshiba

Toshiba Carrier RAV-SP180KRT-UL User manual

Toshiba MMD-AP0054SPH-E User manual

Toshiba

Toshiba MMD-AP0054SPH-E User manual

Toshiba RAS-18 Series User manual

Toshiba

Toshiba RAS-18 Series User manual

Toshiba RAS-10(7)~16(7)SKV Series User manual

Toshiba

Toshiba RAS-10(7)~16(7)SKV Series User manual

Toshiba RAV-SM560KRT-E User manual

Toshiba

Toshiba RAV-SM560KRT-E User manual

Toshiba RAS-07J2KVSG-UA User manual

Toshiba

Toshiba RAS-07J2KVSG-UA User manual

Toshiba MMK-AP0054MHP-E User manual

Toshiba

Toshiba MMK-AP0054MHP-E User manual

Toshiba RAV-SM304SDT-TR User manual

Toshiba

Toshiba RAV-SM304SDT-TR User manual

Toshiba RAS-M10PKVP-E User manual

Toshiba

Toshiba RAS-M10PKVP-E User manual

Toshiba R410A User manual

Toshiba

Toshiba R410A User manual

Toshiba RAV-SM1101DTP-A User manual

Toshiba

Toshiba RAV-SM1101DTP-A User manual

Toshiba RAV-GM302ATP-E User manual

Toshiba

Toshiba RAV-GM302ATP-E User manual

Toshiba MMK-AP0074MHP-E User manual

Toshiba

Toshiba MMK-AP0074MHP-E User manual

Toshiba RAV-SP804AT-E User manual

Toshiba

Toshiba RAV-SP804AT-E User manual

Toshiba MMW-UP0271LQ-E User manual

Toshiba

Toshiba MMW-UP0271LQ-E User manual

Toshiba MD-VNK802HEXE User manual

Toshiba

Toshiba MD-VNK802HEXE User manual

Toshiba RAS-M07N3KV2-E User manual

Toshiba

Toshiba RAS-M07N3KV2-E User manual

Toshiba RAV-GM901UTP Series User manual

Toshiba

Toshiba RAV-GM901UTP Series User manual

Toshiba MMC-AP0157HP-E (TR) User manual

Toshiba

Toshiba MMC-AP0157HP-E (TR) User manual

Toshiba RAV-SM562XT-E User manual

Toshiba

Toshiba RAV-SM562XT-E User manual

Toshiba RAS-22 SKVR Series User manual

Toshiba

Toshiba RAS-22 SKVR Series User manual

Toshiba MCY-MAP0604HT8 User manual

Toshiba

Toshiba MCY-MAP0604HT8 User manual

Toshiba TCB-IFLN642TLE User manual

Toshiba

Toshiba TCB-IFLN642TLE User manual

Toshiba RBM-BT14E User manual

Toshiba

Toshiba RBM-BT14E User manual

Popular Air Conditioner manuals by other brands

LG LW1013ER specification

LG

LG LW1013ER specification

Retro Aire R30C Installation, operation & maintenance manual

Retro Aire

Retro Aire R30C Installation, operation & maintenance manual

Maplin A75TB user manual

Maplin

Maplin A75TB user manual

Fujitsu AUT12 operating manual

Fujitsu

Fujitsu AUT12 operating manual

Carrier 42HVM109303 Service manual

Carrier

Carrier 42HVM109303 Service manual

Airwell Dakota DCI Series Service manual

Airwell

Airwell Dakota DCI Series Service manual

Panasonic PZ2 Series operating instructions

Panasonic

Panasonic PZ2 Series operating instructions

MegaLife NEBULA GREEN R32 Use and Installation Instructions

MegaLife

MegaLife NEBULA GREEN R32 Use and Installation Instructions

Samsung AW05F05EA Owner's instructions

Samsung

Samsung AW05F05EA Owner's instructions

Mitsubishi Electric Mr. SLIM SLZ-M15FA2.TH Technical & service manual

Mitsubishi Electric

Mitsubishi Electric Mr. SLIM SLZ-M15FA2.TH Technical & service manual

Haier HSU-10VNJ17 Operation manual

Haier

Haier HSU-10VNJ17 Operation manual

EINHELL Split 3500 EQ C+H operating instructions

EINHELL

EINHELL Split 3500 EQ C+H operating instructions

Hitachi RAS-18LH2 Service manual

Hitachi

Hitachi RAS-18LH2 Service manual

GE ASQ12AL Dimensions and installation information

GE

GE ASQ12AL Dimensions and installation information

Sinclair ASH-09AIE2 user manual

Sinclair

Sinclair ASH-09AIE2 user manual

Dometic Blizzard NXT H540315 installation instructions

Dometic

Dometic Blizzard NXT H540315 installation instructions

Amana PGB**C installation instructions

Amana

Amana PGB**C installation instructions

LG Multi V Series Svc manual

LG

LG Multi V Series Svc manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.