Installation and Assembly: Hitachi Short Throw Wall Arm
Model: CPA100WALLARM
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 865-2112 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
Maximum Load Capacity: 50 lb (22.7 kg)

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
2 of 12
NOTE: Read entire instruction sheet before you start installation and assembly.
• DonotbegintoinstallyourPeerlessproductuntilyouhavereadandunderstoodtheinstructionsandwarnings
containedinthisInstallationSheet.Ifyouhaveanyquestionsregardinganyoftheinstructionsorwarnings,please
callPeerlesscustomercareat1-800-865-2112.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Makesure that the supporting surface will safely support the combined load of the equipment and all attached hard-
wareand components.
• Neverexceed the Maximum Load Capacity. See pageone.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an
"edgeto edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tightenscrews firmly,but do not overtighten. Overtightening candamagethe items, greatly reducing their holding
power.
• Thisproductis intended for indoor use only. Use of this product outdoorscould leadtoproduct failure and personal
injury.
• Thisproduct was designed and intended to be mounted tothefollowing supporting surfaces checked below with the
hardware included in this product as specified in the installation sheet.To mount this product to an alternative support-
ing surface, contact Peerless customer care at 1 800 865-2112.
• This product was designed to be installed on the following wall construction only;
WALLCONSTRUCTION ADDITIONALHARDWAREREQUIRED
xWoodStud None
xWoodBeam None
xSolidConcrete None
xCinderBlock None
xMetalStud Do not attach except with Peerless accessory kit for metal studs;
Contact Customer Service for Peerless accessory kit for metal studs.
Brick ContactCustomer Service
Otheror unsure? ContactCustomer Service
WARNING
Tools Needed for Assembly
•studfinder ("edge to edge" stud finder is recommended)
•phillipsscrewdriver
•drill
•1/4" bit for concrete and cinder block wall
•1/2" bit for metal stud wall
•5/32" bit for metal or wood stud wall
•level

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
3 of 12
Description Qty. Part #
Aslide plate 1 055-1821
Bprojector mount assembly 1 055-1803
C#10-32 x 3/8" serrated washer head socket pin screw 2 520-1151
D#10-32 x 1/4" socket pin screw 1 520-1196
E5/32" (4 mm) security allen wrench 1 560-9646
F6.5 ID flat washer 2 540-1078
G#14 x 2.5" wood screw 4 5S1-015-C03
HAlligator®anchor 4 590-0097
I3/32" (2 mm) security allen wrench 1 560-1097
Jwall arm 1 055-1820
Kwall plate 1 055-1818
Ladapter plate 1 055-1822
M1/4-20 x 1" hex head screw 2 520-1606
N1/4" ID spacer 2 560-1723
O0.509" ID spacer 2 590-1270
P0.376 ID shoulder spacer 2 590-1269
Qrectangle plug 1 590-1302
Rcircle plug 2 590-1301
S2" rubber grommet 1 560-1726
T1.75" rubber grommet 1 560-1168
UM6 x 12 mm serrated washer head socket pin screw 8 510-1050
Vwasher fender 4 540-1008
Wvinyl trim 1 600-1012
X0.25" spacer 4 590-1050
Parts List
Partsmay appear slightly different than illustrated.
Beforeyou begin, make sure all parts shown are included with your product. B
C
A
D
G
E
H
F
I
O
JK L MN
P
QR
U
VW
X
S T

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
4 of 12
NOTE: Use the chart (see fig 1.1) below to determine the placement of projector in relation to mounting location of
wall arm. Chart numbers will have a 3% discrepancy due to the optics of the projector. Prior to installing projector,
physically test the projection size and distance while having the actual projector in the desired location before
installing, this will determine the exact mounting position.
Projector Position
1
fig. 1.1
SCREEN/WHITEBOARD
3.65
93
(X)
CENTER OF
WALLARM
CENTER OF
LENS
fig. 1.2
* The distance from the bottom of the
projector to the top of the screen.
(Z)
THROWDISTANCE:(Y)
(Thedistancefromprojectoredgetoscreensurface)
3.9" (9.9 cm)
NOTE: Lens is not centered to the wall arm
14.8" (37.5 cm)
Screen size
(
X
)
inch inch cm inch cm
63 5.9 14.9 13.0 33.0
70 8.0 20.3 14.0 35.5
77 10.0 25.4 15.0 38.1
80 11.0 27.9 15.5 39.4
90 14.0 35.5 16.9 42.9
100 16.9 42.9 18.4 46.7
Throw Distance
(
Y
)
Image Offset *
(
Z
)

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
5 of 12
Use a stud finder to locate the edges of the studs. Use of an edge-to-edge stud finder is highly recommended. Based
on their edges, draw a vertical line down each stud’s center. Place wall plate (K) on wall as a template. Level plate,
and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud centerline. Drill
four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate (K) is level, secure it using four
#14 x 2.5" wood screws (G) and fender washers (V) as shown in figure 2.1.
Installation to Wood Stud Wall
• Installermust verify that the supporting surface will safely support the combined load of the equipment andallattached
hardwareandcomponents.
• Tightenwood screws so that wall plate is firmly attached, but donotovertighten.Overtightening can damage the
screws,greatly reducing their holdingpower.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highlyrecommended.
• Hardwareprovided is for attachment of mount throughstandardthickness drywall or plaster into wood studs.Installers
areresponsible to provide hardwarefor other types ofmountingsituations.
WARNING
fig. 2.1
G
K
V
2

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
6 of 12
Make sure that wall plate (K) is level, use it as a
template to mark four mounting holes. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (65 mm).
Insert anchors (H) in holes flush with wall as shown
(right).Placewall plate over anchors and secure with
four #14 x 2.5" screws (G) and fender washers (V).
Level,thentightenallfasteners.
Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breakingout the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Makesure that the supporting surface will safely support the combined load of the equipment and all attached hard-
wareand components.
WARNING
CONCRETE
SURFACE
1
3
2
H
Drill holes and insert anchors (H).
Place plate (K)over anchors (H) and secure with screws (G)
and fender washers (V).
Tighten all fasteners.
KH
G
CUTAWAYVIEW
INCORRECT
CORRECT
wallplate
plaster/
drywall
concrete
wallplate concrete
plaster/
drywall
• Always attach concrete anchors directly to load-
bearingconcrete.
• Neverattach concrete anchorsto concrete covered
withplaster,drywall, or other finishing material. If
mountingto concrete surfaces coveredwitha finishing
surfaceis unavoidable, the finishing surfacemust be
counterboredas shown below.Be sureconcrete
anchorsdo not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
• Tighten screws so that wall plate is firmly attached,
butdo not overtighten.Overtightening candamage
screws,greatly reducing their holdingpower.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
G
K
V
SOLIDCONCRETE
CINDERBLOCK
H
V
• Always attach concrete anchors directly to load-
bearingconcrete.
• Neverattach concrete anchorsto concrete covered
withplaster,drywall, or other finishing material. If
mountingto concrete surfaces coveredwitha finishing
surfaceis unavoidable, the finishing surfacemust be
counterboredas shown below.Be sureconcrete
anchorsdo not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
2

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
7 of 12
Wall plate (K) can be mounted to single metal stud. Use a stud finder to locate the edges of the stud. Use of an
edge-to-edge stud finder is highly recommended. Based on it's edges, draw a vertical line down stud’s center. Place
wall plate on wall as a template. Level plate, and mark the center of the four mounting holes. Make sure that the
mounting holes are on the stud centerline. Drill four 1/2" holes through drywall and metal stud. NOTE: It may be
necessary to drill 5/32" pilot holes prior to drilling 1/2" holes.
Refer to instruction sheet included with Peerless accessory kit ACC 415 for metal studs to install togglers.
Loosely fasten wall plate (K) to wall using four 1/4-20 x 2-1/2" screws as shown in figure 2.2.
Level, hold, and then tighten all screws.
• Drywall must be 1/2" or thicker, and metal stud must be 24 gauge or thicker.
• Installermust verify that the supporting surface will safely support the combined load of the equipment andallattached
hardwareandcomponents.
WARNING
Installation to Metal Stud Wall (Metal Stud Accessory Kit ACC 415 Required)
TOGGLER
(NOTINCLUDED)
K
fig. 2.2
1/4-20 X 2-1/2"
PHILLIPSSCREWS
(NOTINCLUDED)
2

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
8 of 12
Hook wall arm (J) onto wall plate (K) as shown in
fig.3.2orfor additional vertical adjustment fig. 3.3.
Run cords through desired opening at this point.
fig. 3.3
SUPPORTING
SURFACENOT
SHOWNFOR
CLARITY
Disengageconnectionblockfromprojectormount
assembly (B)by unscrewing captive screw and sliding
out connection block as shown.
K
J
3
4
K
J
OR
fig. 3.2
fig. 3.1
KW
Place vinyl trim (W) onto bottom or top of wall plate (K)
where cords will be routed as shown in fig. 3.1.
Secure arm to wall plate (K) using four M6 x 12 mm
serrated washer head socket pin screws (U) as
shown in fig. 3.4.Cut 1.75" rubber grommet (T)in
half and place into half moons on top and bottom of
wall arm (J). Insert circle plug (R) or 2" rubber
grommet (S) into arm fig. 3.4.
3-2
3-2
CONNECTION
BLOCK
CAPTIVE
SCREW
B
fig. 3.4
1.75"RUBBER
GROMMET
(CUTINHALF)
1/2OF
GROMMET(T)
1/2OF
GROMMET(T)
J
U
T
R
R
SOR
3-2
3-1
NOTE: Ifcords inserted through top or bottom openings,use
vinyltrim. Otherwise insert cords throughsecondaryopenings
on wall face as shown in fig. 3.2 and 3.3.
Secondary
Openings

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
9 of 12
NOTE: Do not tighten 1/4-20 x 1" hex head screws (M) fully to allow for adjustment. Fasten projector mount
assembly (B) to wall arm (J) using two 1/4-20 x 1" hex head screws (M), 0.509" ID spacers (O), 1/4"ID spacers (N),
0.376 ID shoulder spacers (P) and slide plate (A) as shown in fig. 5.1 and 5.2. Insert rectangle plug (Q) into wall
arm (J) as shown in fig. 5.3. See fig. 1.1 and 10.1 for additional adjustment of image size. Securely tighten both 1/4-
20 x 1" hex head screws (M) after desired image size is obtained.
FRONT VIEW
N
O
M
P
A
J
B
fig. 5.1 fig. 5.2
Q
J
J
N
OB
M
P
fig. 5.3
5
A

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
10 of 12
PROJECTOR
Attachadapter plate (L) to projector using four
M6 x 12 mm serrated washer head socket pin
screws (U) and 0.25" spacers (X).
NOTE: Shoulderof connection block indicates
theback of projector.
SHOULDER
CONNECTION
BLOCK
CONNECTION
BLOCK
NOTCHINDICATES
FRONTOF
PROJECTOR
SHOULDER
Attaching Adapter Plate to Projector
fig. 6.1
Align shoulder on connection block opposite notch in
adapter plate (L). Attach adapter plate (L) to
connectionblock from projector mount assembly (B)
using two #10-32 x 3/8" serrated washer head socket
pin screws (C) as shown in figure 6.1.
L
U
X
L
C
6
7

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
11 of 12
Slide connection block with projector into projector mount assembly (B) as shown. Tighten captive screw to secure
projectorto projector mount assembly (B).
IMPORTANT: For security installations, insert one #10-32 x 1/4" socket pin screw (D) through projector mount
assembly (B) and into connection block as shown. Tighten screw using 4mm security allen wrench (E).
CONNECTION
BLOCK
• Donotliftmoreweightthanyoucanhandle.Useadditionalmanpowerormechanicalliftingequipmenttosafelyhandle
placementof the projector.
CONNECTION
BLOCK
Attaching Adapter Plate to Projector Mount
FRONTOF
MOUNT
CAPTIVE
SCREW
ARROWINDICATES
FRONTOFMOUNT B
B
B
D
8
9
WARNING

ISSUED: 03-17-08 SHEET #:055-9499-4 08-15-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
12 of 12
To adjust yaw (swivel): Loosen screw on projector mount assembly (B) indicated below until projector mount
can be rotated. Rotate mount to desired position and retighten screw.
To adjust pitch (forward and backward tilt): Turn knob on back of mount as shown below. Pull knob out and
turn by hand for easy adjustment or insert #2 phillips screwdriver in end of knob and turn.
To adjust roll (side to side tilt): Turn knob on side of mount as shown below. Pull knob out and turn by hand
foreasyadjustmentor insert #2 phillips screwdriver in end of knob and turn.
Projector Alignment
SCREWFORYAW
(SWIVEL)STOP
KNOBFORROLL
ADJUSTMENT
KNOBFORPITCH
ADJUSTMENT
BACKOFMOUNT
To prevent tampering with the pitch and roll adjustments:Tighten the two tamper resistant security screws
on the projector mount assembly (B) using 4 mm security allen wrench (E) to lock the pitch and roll adjustments
asshown below.
NOTE:Tightenscrews firmly, but do not overtighten. Overtighteningcandamagethemount.
• Do not adjust pitch or roll while tamper resistant security screws are fully engaged.
• Loosen the two tamper resistant security screws one complete turn before adjusting the projector mount assembly or
damagemay occur.
CAUTION
ARROWINDICATES
FRONTOFMOUNT
TOLOCKROLLTIGHTEN
TAMPER RESISTANT
SECURITY SCREW TOLOCKPITCHTIGHTEN
TAMPER RESISTANT
SECURITY SCREW
FRONT VIEW SIDE VIEW
©2008,PeerlessIndustries,Inc.Allrightsreserved.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.
B
10-1
10
fig. 10.1
Table of contents
Other Touchboards Rack & Stand manuals

Touchboards
Touchboards PANA-103MTV Guide

Touchboards
Touchboards 55282 User manual

Touchboards
Touchboards Black Box Network Services NBDEP-12 User manual

Touchboards
Touchboards PM2-S-XL User manual

Touchboards
Touchboards peerless-AV PRS-KIT0811 Guide

Touchboards
Touchboards peerless-AV SS560F User manual

Touchboards
Touchboards BALT T-LECT 85751 User manual

Touchboards
Touchboards PSD-VHS User manual

Touchboards
Touchboards peerless-AV SR560M-AB User manual

Touchboards
Touchboards LINK 55140 User manual