TOURNADO ip EXA User manual

Blizzard Lighting, LLC
www.blizzardlighting.com
Waukesha, WI USA
Copyright (c) 2014
ip EXA
tm
SUITABLE FOR OUTDOOR USE

Page 2
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
TABLE OF CONTENTS
TOURnado™ IP EXA 1
1. Getting Started 3
What’s In The Box? 3
Getting It Out Of The Box 3
Powering Up! 3
Getting A Hold Of Us 3
Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4
2. Meet The TOURnado™ IP EXA 5
Features 5
DMX Quick Reference 5
The TOURnado™ IP EXA Pin-up Picture 6
3. Setup 7
Fuse Replacement 7
Connecting A Bunch Of TOURnado™ IP EXA Fixtures 7
Data/DMX Cables 7
Cable Connectors 8
3-Pin??? 5-Pin??? Huh? 8
Take It To The Next Level: Setting up DMX Control 8
Fixture Linking (Master/Slave Mode) 9
Mounting/Rigging 9
4. Operating Adjustments 10
Navigating The Control Panel 10
Control Panel Menu Structure 11
DMX Mode 12
Set The Starting DMX Address 12
Select the DMX Channel Mode 12
Slave Mode 12
Auto, Stand-Alone, & Built-in Program Modes 12
Auto Mode 12
Stand-Alone (Program) Mode 12
Built-in Program Speed 12
Flash/Fade Modes 12
Manual Color Adjustment 12
Dimming Modes 13
DMX Channel Values In-Depth 13
Troubleshooting 15
5. Appendix 16
A Quick DMX Lesson 16
Keeping Your TOURnado™ IP EXA As Good As New 17
Returns (Gasp!) 17
Shipping Issues 17
Tech Specs 18
Dimensional Drawings 19

Page 3
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
1. GETTING STARTED
What’s In The Box?
• 1 x TOURnado™ IP EXA Professional LED PAR Fixture
• 1 x IP Rated AC power cord with cable cap
• 1 x Set of IP Rated DMX in/out cables
• This Lovely User Manual
Optional Accessories (sold separately)
The following accessories are available for this xture. But the lone wolves that they are, they must be
purchased separately. Contact your authorized Blizzard Lighting dealer for pricing!
• TOURLens45: 45° Beam Angle Lens Replacement Kit
• CABLE_TOURData1M: 1-Meter IP-Rated DMX Extension Cable
• CABLE_TOURPower1M: 1-Meter IP-Rated Power Extension Cable
• CABLE_TOURData3M: 3-Meter IP-Rated DMX Extension Cable
• CABLE_TOURPower3M: 3-Meter IP-Rated Power Extension Cable
• CABLE_TOURData5M: 5-Meter IP-Rated DMX Extension Cable
• CABLE_TOURPower5M: 5-Meter IP-Rated Power Extension Cable
Getting It Out Of The Box
Congratulations! You’re now the proud owner of one tough, slightly pumpkin shaped PAR xture! And now
that you’ve got your TOURnado™ (or hopefully, TOURnados!), you should carefully unpack the box and
check the contents to ensure that all parts are present and in good condition. If anything looks as if it has
been damaged in transit, notify the shipper immediately and keep the packing material for inspection.
Again, please save the carton and all packing materials. If a xture must be returned to the factory, it is
important that the xture be returned in the original factory box and packing.
Powering Up!
All xtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to
100% switch.
AC Voltage Switch - Not all xtures have a voltage select switch, so please verify that the xture you
receive is suitable for your local power supply. See the label on the xture or refer to the xture’s
specications chart for more information. A xture’s listed current rating is its average current draw under
normal conditions. Check the xture or device carefully to make sure that if a voltage selection switch
exists that it is set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the line voltage applied.
Damage to your xture may result if the line voltage applied does not match the voltage
indicated on the voltage selector switch. All xtures must be connected to circuits with a
suitable Ground (Earthing).
Getting A Hold Of Us
If something is wrong, just give us a call or send an email. We’ll be happy to help, honest.
Blizzard Lighting
N16 W23390 Stoneridge Dr. Ste E
Waukesha, WI 53188 USA
www.blizzardlighting.com
414-395-8365
Email: [email protected]
Disclaimer: The information and specications contained in this document are subject to change without
notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may
appear in this user manual. Blizzard Lighting™ reserves the right to update the existing document or
to create a new document to correct any errors or omissions at any time. You can download the latest
version of this document from www.blizzardlighting.com.
Author: Date: Last Edited: Date:
J. Thomas 5/29/2014 J. Thomas 8/3/2015

Page 4
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
SAFETY INSTRUCTIONS
• Please keep this User Guide for future use. If you sell the unit to someone
else, be sure that they also receive this User Guide.
• ALWAYS make sure that you are connecting to the proper voltage, and that
the line voltage you are connecting to is not higher than that stated on the de-
cal or rear panel of the xture.
• Make sure there are no ammable materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least
20in (50cm) from adjacent surfaces.
• ALWAYS disconnect from the power source before servicing or replacing fuse
and be sure to replace with same fuse size and type.
• ALWAYS secure xture using a safety chain. NEVER carry the xture by its
cord. Use its carrying handles.
• DO NOT operate at ambient temperatures higher than 104°F (40°C).
• In the event of a serious operating problem, stop using the unit immediately.
NEVER try to repair the unit by yourself. Repairs carried out by unskilled people
can lead to damage or malfunction. Please contact the nearest authorized tech-
nical assistance center. Always use the same type spare parts.
• NEVER connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not
open the housing or attempt any repairs yourself. In the unlikely event
your unit may require service, please contact Blizzard Lighting at sup-

Page 5
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
2. MEET THE TOURNADO™ IP EXA LED PAR
CONTROL FEATURES
• RGBAW+UV color mixing via 12x 15W 6-in-1 LEDs
• LED control panel with 4 touch sensitive electronic buttons
• Super-sharp 25° beam angle
• Variable electronic dimming & strobe
• Built-in color & chase macros via DMX
• Built-in automated programs via master/slave
• RGBAW+UV color mixing ability in standalone mode
• RGBAW+UV (6-Ch), RGBAW+UV & Strobe (7-Ch), Dim, RGBAW+UV
& Strobe (8-Ch), & Extended w/32-bit dimming (11-Ch) DMX Proles
ADDITIONAL FEATURES
• Rugged and well-built (It hits the gym regularly)
• Convection cooled cast aluminum housing
• Dual mounting brackets for positioning exibility
• Flicker-free constant-current 500MA LED driver
• IP rated locking power and 3-pin DMX connections
DMX Quick Reference - 11 / 8 Channel Mode
Channel 11 Channel 8 Channel
1 Dimmer Dimmer
2 Red Intensity Red Intensity
3 Green Intensity Green Intensity
4 Blue Intensity Blue Intensity
5 Amber Intensity Amber Intensity
6 White Intensity White Intensity
7 UV Intensity UV Intensity
8 Strobe Strobe
9 Static Colors + Auto ---
10 Built-in Programs ---
11 32-bit Dimming ---
DMX Quick Reference - 7 / 6 Channel Mode
Channel 7 Channel 6 Channel
1 Red Intensity Red Intensity
2 Green Intensity Green Intensity
3 Blue Intensity Blue Intensity
4 Amber Intensity Amber Intensity
5 White Intensity White Intensity
6 UV Intensity UV Intensity
7 Strobe ---

Page 6
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Figure 1: The TOURnado™ IP EXA Pin-Up Picture
High Power 6-in-1
RGBAW+UV LEDs
Heavy-Duty Cast
Aluminum Enclosure
Dual Adjustable
Mounting Brackets
Figure 2: The Rear Connections
AC Power Out
DMX In DMX Out
Touch Sensitive
Menu Buttons
AC Power In
LED Display
4-Character LED
Control Panel
Secure Grip
Locking Knobs

Page 7
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The TOURnado™ IP EXA utilizes a high-output switch-
mode power supply with an internal fuse. Under normal operating
conditions, the fuse should not require replacement. The fuse is eld
replaceable, however it is an advanced procedure suited to qualied
individuals. Should your TOURnado™ IP EXA fuse require replace-
ment, please contact Blizzard Lighting for instructions, or to return
your unit for service.
Connecting A Bunch of TOURnado™ IP EXA Fixtures
You will need a serial data link to run light shows using a DMX-512
controller or to run shows on two or more xtures set to sync in mas-
ter/slave operating mode. The combined number of channels required
by all the xtures on a serial data link determines the number of x-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also, connecting more than 32 xtures on one serial data link without
the use of a DMX optically-isolated splitter may result in deterioration
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640
ft). The maximum recommended number of xtures on a serial data
link is 32 xtures.
Data/DMX Cabling
To link xtures together you’ll need data cables. You should use data-
grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
For instance, Belden© 9841 meets the specications for EIA RS-485
applications. Standard microphone cables will “probably” be OK, but
note that they cannot transmit DMX data as reliably over long distanc-
es. In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms

Page 8
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR
connector on the other end. (Duh!)
CAUTION: Do not allow contact between the common and the x-
ture’s chassis ground. Grounding the common can cause a ground
loop, and your xture may perform erratically. Test cables with an
ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each other.
3-Pin??? 5-Pin??? Huh?!?
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
They are widely available over the internet and from specialty retailers If you’d like to build your own, the
chart below details a proper cable conversion:
Conductor 3-Pin Female
(Output)
5-Pin Male
(Input)
Ground/Shield Pin 1 Pin 1
DMX Data (-) Pin 2 Pin 2
DMX Data (+) Pin 3 Pin 3
Not Used. No Connection. No Connection.
Not Used. No Connection. No Connection.
Take It To The Next Level: Setting Up DMX Control
Step 1: Connect the male connector of the
DMX cable to the female connector (output)
on the controller.
Step 2: Connect the female connector of the
DMX cable to the rst xture’s male connec-
tor (input). Note: It doesn’t matter which
xture address is the rst one connected.
We recommend connecting the xtures in
terms of their proximity to the controller,
rather than connecting the lowest xture
number rst, and so on.
Step 3: Connect other xtures in the chain
from output to input as above. Place a DMX
terminator on the output of the nal xture
to ensure best communication.

Page 9
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Fixture Linking (Master/Slave Mode)
1. Connect the (male) 3 pin connector side of the
DMX cable to the output (female) 3 pin connector of
the rst xture.
2. Connect the end of the cable coming from the
rst xture which will have a (female) 3 pin connec-
tor to the input connector of the next xture con-
sisting of a (male) 3 pin connector. Then, proceed
to connect from the output as stated above to the
input of the following xture and so on.
A quick note: Often,
the setup for Master-
Slave and Standalone
operation requires that
the rst xture in the
chain be initialized for
this purpose via either
settings in the control
panel or DIP-switches.
Secondarily, the xtures
that follow may also re-
quire a slave setting.
Check the “Operating Adjustments” section in this manual for com-
plete instructions for this type of setup and conguration.
Mounting & Rigging
This xture may be mounted in any SAFE position provided there is
enough room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
xture using a suitable “C” or “O” type clamp. The clamp should be
rated to hold at least 10x the xture’s weight to ensure structural sta-
bility. Do not mount to surfaces with unknown strength, and ensure
properly “rated” rigging is used when mounting xutres overhead.
Adjust the angle of the xture by loosening both knobs and tilting the
xture. After nding the desired position, retighten both knobs.
• When selecting installation location, take into consideration lamp
replacement access (if applicable) and routine maintenance.
• Safety cables MUST ALWAYS be used.

Page 10
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
4. OPERATING ADJUSTMENTS
The Control Panel
All the goodies and different modes possible with the TOURnado™ IP
EXA LED are accessed by using the control panel on the rear of the
xture. There are 4 control buttons below the LED display which allow
you to navigate through the various control panel menus.
<MENU>
Is used to navigate to the previous higher-level menu item.
<UP>
Scrolls through menu items and numbers in ascending order.
<DOWN>
Scrolls through menu items and numbers in descending order.
<ENTER>
Is used to select and conrm/store the current selection.
The Control Panel LED Display shows the menu items you select from
the menu map on page #11. When a menu function is selected, the
display will show immediately the rst available option for the selected
menu function. To select a menu item, press <ENTER>.
Use the <UP> and <DOWN> buttons to navigate the menu options.
Press the <ENTER> button to select the menu function currently dis-
played, or to enable a menu option. To return to the previous option or
menu, press the <MENU> button.

Page 11
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Addr d001 - d512 To choose the DMX address
SLAU SLAu To run the xture in slave mode
CHnd
11 CH 11 channel DMX mode
8CH 8 channel DMX mode
7CH 7 channel DMX mode
6CH 6 channel DMX mode
nodE nod0-nod4 Dimming mode (0-4)
SP -- SP00 -SP15 Speed adjustments (0-15)
Pr -- Pr00 -Pr63 Built-in programs (0-63)
ASC - AC00 -AC15 Auto mode (0-15)
FAdE FA00 -FA15 Fade settings (0-15)
FLAS FL00 -FL15 Flash / strobe speed (0-15)
rL -- r000 - r255 Red dimmer (0% <--> 100%)
GL -- G000 - G255 Green dimmer (0% <--> 100%)
bL -- b000 - b255 Blue dimmer (0% <--> 100%)
AL -- A000 - A255 Amber dimmer (0% <--> 100%)
UL -- U000 - U255 White dimmer (0% <--> 100%)
uL -- U000 - U255 UV dimmer (0% <--> 100%)
LED on - oFF Display menu on/off
Control Panel Menu Structure
IMPORTANT! - As a safety feature, the LED control panel display will
automatically shut off and lock after 20 seconds of inactivity. To unlock it,
simply hold down any button for 10 seconds.
So if your installation site is overrun with wild kittens, dogs, or any animals you
need not worry that they’ll change your settings with their little noses!

Page 12
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
Set the Starting DMX Address:
The default mode for the xture is DMX, so the rst menu item that you can edit is the
starting DMX address.
1.) Navigate the menu using the <UP/DOWN> buttons until you reach Addr.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select a DMX channel from 001-512.
4.) Press the <ENTER> button to conrm.
Select the DMX Channel Mode:
1.) Navigate the menu using the <UP/DOWN> buttons until you reach CHnd.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select either 6CH, 9CH, or 11CH mode.
4.) Press the <ENTER> button to conrm.
Slave Mode:
To synchronize one or more xtures to follow the actions of the Master xture (the 1st unit in
the DMX chain), perform the following steps on each Slave xture:
1.) Set the DMX address to A001.
2.) Navigate the menu using the <UP/DOWN> button until you reach SLAU.
3.) Push the <ENTER> button.
4.) Use the <UP/DOWN> buttons to select SLAu.
5.) Press the <ENTER> button to conrm.
Auto, Stand-Alone, & Built-in Program Modes:
Allows a single or Master/Slaved units to run factory installed programs at user selectable speeds.
Auto Mode:
1.) Navigate the menu using the <UP/DOWN> button until you reach ASC-.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select from AC00-AC15.
4.) Press the <ENTER> button to conrm.
Standalone (Program) Mode:
Allows a single unit to display a variety of colors and programs without a DMX controller.
1.) Navigate the menu using the <UP/DOWN> button until you reach Pr--.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select from Pr00-Pr63.
4.) Press the <ENTER> button to conrm.
Flash/Fade Modes:
1.) Navigate the menu using the <UP/DOWN> buttons until you reach FLAS or FAdE.
2.) Push the <ENTER> button.
3.) Now, you can adjust the ash rate from FL00-FL15 or the fade speed from FA00-FA15
with the <UP/DOWN> buttons. Press the <ENTER> button to conrm.
Built-in Program Speed:
1.) Navigate the menu using the <UP/DOWN> button until you reach SP-.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select from SP00-SP15.
4.) Press the <ENTER> button to conrm.
Manual Color Adjustment:
1.) Navigate the menu using the <UP/DOWN> button until you reach either rL-- (Red),
GL-- (Green), bL-- (Blue). AL-- (Amber), UL-- (White), or uL-- (UV) then hit <ENTER>.
2.) Using the <UP/DOWN> buttons, select the maximum level for each color between
x000-x255 (000=off), then hit <ENTER> to conrm.

Page 13
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Dimming Mode
Each allows for different amounts of steps for much smoother (and slower) dimming capabilities.
1.) Navigate the menu using the <UP/DOWN> buttons until you reach nodE.
2.) Push the <ENTER> button.
3.) Use the <UP/DOWN> buttons to select nod0-nod4.
4.) Press the <ENTER> button to conrm.
DMX Values In-Depth (11-Channel Mode)
Channel Value What It Does
1 000 <--> 255 Dimmer (0% <--> 100%)
2 000 <--> 255 Red Intensity (0% <--> 100%)
3 000 <--> 255 Green Intensity (0% <--> 100%)
4 000 <--> 255 Blue Intensity (0% <--> 100%)
5 000 <--> 255 Amber Intensity (0% <--> 100%)
6 000 <--> 255 White Intensity (0% <--> 100%)
7 000 <--> 255 UV Intensity (0% <--> 100%)
8
000 <--> 010
011 <--> 255
Strobe
No Function
Strobe (Slow <--> Fast)
9
000 <--> 015
016 <--> 018
019 <--> 021
022 <--> 024
025 <--> 027
028 <--> 030
031 <--> 033
034 <--> 036
037 <--> 039
040 <--> 042
043 <--> 045
046 <--> 048
049 <--> 051
052 <--> 054
055 <--> 057
058 <--> 060
061 <--> 063
064 <--> 066
067 <--> 069
070 <--> 072
073 <--> 075
076 <--> 078
079 <--> 081
082 <--> 084
085 <--> 087
088 <--> 090
091 <--> 093
094 <--> 096
097 <--> 099
100 <--> 102
103 <--> 105
106 <--> 108
109 <--> 111
Static Colors + Auto Mode
Dimming
Red
Green
Blue
Amber
White
UV
R+G
R+B
R+A
R+W
R+UV
G+B
G+A
G+W
G+UV
B+A
B+W
B+UV
A+W
A+UV
W+UV
R+G+B
R+G+A
R+G+W
R+G+UV
R+B+A
R+B+W
R+B+UV
R+A+W
R+A+UV
R+W +UV
G+B+A
112 <--> 114
115 <--> 117
118 <--> 120
121 <--> 123
124 <--> 126
127 <--> 129
130 <--> 132
133 <--> 135
136 <--> 138
139 <--> 141
142 <--> 144
145 <--> 147
148 <--> 150
151 <--> 153
154 <--> 156
157 <--> 159
160 <--> 162
163 <--> 165
166 <--> 168
169 <--> 171
172 <--> 174
175 <--> 177
178 <--> 180
181 <--> 183
184 <--> 186
187 <--> 189
190 <--> 192
193 <--> 195
196 <--> 198
199 <--> 201
202 <--> 204
205 <--> 255
G+B+W
G+B+UV
G+A+W
G+A+UV
G+W+UV
B+A+W
B+A+UV
B+W+UV
A+W+UV
R+G+B+A
R+G+B+W
R+G+B+UV
R+G+A+W
R+G+A+UV
R+G+W+UV
R+B+A+W
R+B+A+UV
R+B+W+UV
R+A+W+UV
G+B+A+W
G+B+A+UV
G+B+W+UV
G+A+W+UV
B+A+W+UV
R+G+B+A+W
R+G+B+A+UV
R+G+B+W+UV
R+G+A+W+UV
R+B+A+W+UV
G+B+A+W+UV
R+G+B+A+W+UV
Auto Run (Slow <--> Fast)
10
000 <--> 015
016 <--> 255
Auto Mode
No Function
Color Jump (Slow <--> Fast)
11
000 <--> 005
006 <--> 055
056 <--> 105
106 <--> 155
156 <--> 205
206 <--> 255
32-Bit Dimmer
As set in the control menu display
Mode 0 = 8-bit, 256 dimming steps
Mode 1 = 32-bit, 0-25% intensity range
Mode 2 = 32-bit, 0-50% intensity range
Mode 3 = 32-bit, 0-75% intensity range
Mode 4 = 32-bit, full intensity dimming

Page 14
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
DMX Values In-Depth (6-Channel Mode)
Channel Value What It Does
1 000 <--> 255 Red Intensity (0% <--> 100%)
2 000 <--> 255 Green Intensity (0% <--> 100%)
3 000 <--> 255 Blue Intensity (0% <--> 100%)
4 000 <--> 255 Amber Intensity (0% <--> 100%)
5 000 <--> 255 White Intensity (0% <--> 100%)
6 000 <--> 255 UV Intensity (0% <--> 100%)
DMX Values In-Depth (7-Channel Mode)
Channel Value What It Does
1 000 <--> 255 Red Intensity (0% <--> 100%)
2 000 <--> 255 Green Intensity (0% <--> 100%)
3 000 <--> 255 Blue Intensity (0% <--> 100%)
4 000 <--> 255 Amber Intensity (0% <--> 100%)
5 000 <--> 255 White Intensity (0% <--> 100%)
6 000 <--> 255 UV Intensity (0% <--> 100%)
7
000 <--> 010
011 <--> 255
Strobe
No Function
Strobe (Slow <--> Fast)
DMX Values In-Depth (8-Channel Mode)
Channel Value What It Does
1 000 <--> 255 Dimmer (0% <--> 100%)
2 000 <--> 255 Red Intensity (0% <--> 100%)
3 000 <--> 255 Green Intensity (0% <--> 100%)
4 000 <--> 255 Blue Intensity (0% <--> 100%)
5 000 <--> 255 Amber Intensity (0% <--> 100%)
6 000 <--> 255 White Intensity (0% <--> 100%)
7 000 <--> 255 UV Intensity (0% <--> 100%)
8
000 <--> 010
011 <--> 255
Strobe
No Function
Strobe (Slow <--> Fast)

Page 15
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Troubleshooting
Symptom Solution
Fixture Auto-
Shut Off
Check the fan in the xture. If it is stopped or moving
slower than normal, the unit may have shut itself off due to
high heat. This is to protect the xture from overheating.
Clear the fan of obstructions, or return the unit for service.
Beam is Dim Check optical system and clean excess dust/grime. Also
ensure that the 220V/110V switch is in the correct position,
if applicable.
No Light Output Check to ensure xture is operating under correct mode, IE
sound active/auto/DMX/Etc., if applicable.
Chase Speed
Too Fast/Slow
Check to ensure proper setup of speed adjustment.
No Power Check fuse, AC cord and circuit for malfunction.
Blown Fuse Check AC cord and circuit for damage, verify that moving
parts are not restricted and that unit’s ventilation is not
obstructed
Slow Movement Verify that 220V/110V switch is in the correct position, if
applicable. Also check that speed channels are set appro-
priately.
No Response to
Audio
Verify that the xture is in “Sound Active” mode.
Adjust Audio Sensitivity, If Applicable.
Fixture Not
Responding /
Responding Er-
ratically
Make sure all connectors are seated properly and securely.
Use Only DMX Cables and/or check cables for defects
Install a Terminator.
Reset xture(s).
Intermittent
Lamp
Check lamp for properly installation.
Relamp, lamp may have reached end of life.
Remote Doesn’t
Work
Verify remote control cable is installed properly and se-
curely.
Verify remote is correct type (CA-9 or other as applicable.)
Fixture Moving
On Its Own
Verify proper mode of operation. Is the xture in “Auto”
mode?

Page 16
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
5. APPENDIX
A Quick Lesson On DMX
DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre
Technology (USITT) as a standardized method for connecting lighting consoles to lighting
dimmer modules. It was revised in 1990 and again in 2000 to allow more exibility. The
Entertainment Services and Technology Association (ESTA) has since assumed control over
the DMX512 standard. It has also been approved and recognized for ANSI standard clas-
sication.
DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common
communications standard used by lighting and related stage equipment.
DMX provides up to 512 control “channels” per data link. Each of these channels was origi-
nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting
console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an
8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb
being completely off while 255 corresponds to the light bulb being fully on.
DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan-
dard over two wires. As with microphone cables, a grounded cable shield is used to prevent
interference with other signals.
There are ve pins on a DMX connector: a wire for ground (cable shield), two wires for
“Primary” communication which goes from a DMX source to a DMX receiver, and two wires
for a “Secondary” communication which goes from a DMX receiver back to a DMX source.
Generally, the “Secondary” channel is not used so data ows only from sources to receiv-
ers. Hence, most of us are most familiar with DMX-512 as being employer over typical
3-pin “mic cables,” although this does not conform to the dened standard.
DMX is connected using a daisy-chain conguration where the source connects to the input
of the rst device, the output of the rst device connects to the input of the next device,
and so on. The standard allows for up to 32 devices on a single DMX link.
Each receiving device typically has a means for setting the “starting channel number” that
it will respond to. For example, if two 6-channel xtures are used, the rst xture might
be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next
xture would be set to start at channel 7 so it would respond to channels 7 through 12.
The greatest strength of the DMX communications protocol is that it is very simple and
robust. It involves transmitting a reset condition (indicating the start of a new “packet”),
a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As
soon as one packet is nished, another can begin with no delay if desired (usually another
follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will
be sent out over and over again. This is a great feature of DMX -- if for some reason the
data is not interpreted the rst time around, it will be re-sent shortly.
Not all 512 channels need to be output per packet, and in fact, it is very uncommon to nd
all 512 used. The fewer channels are used, the higher the “refresh” rate. It is possible to
get DMX refreshes at around 1000 times per second if only 24 channels are being trans-
mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per
second.
In summary, since its design and evolution in the 1980’s DMX has become the standard
for lighting control. It is exible, robust, and scalable, and its ability to control everything
from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for
any lighting designer or lighting performer.

Page 17
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Keeping Your TOURnado™ IP EXA As Good As New
The xture you’ve received is a rugged, tough piece of pro lighting equip-
ment, and as long as you take care of it, it will take care of you. That said, like
anything, you’ll need to take care of it if you want it to operate as designed.
You should absolutely keep the xture clean, especially if you are using it in an
environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled
drinks.
Cleaning the optics routinely with a suitable glass cleaner will greatly improve
the quality of light output. Keeping the fans free of dust and debris will keep
the xture running cool and prevent damage from overheating.
In transit, keep the xtures in cases. You wouldn’t throw a prized guitar,
drumset, or other piece of expensive gear into a gear trailer without a case,
and similarly, you shouldn’t even think about doing it with your shiny new light
xtures.
Common sense and taking care of your xtures will be the single biggest thing
you can do to keep them running at peak performance and let you worry about
designing a great light show, putting on a great concert, or maximizing your cli-
ent’s satisfaction and “wow factor.” That’s what it’s all about, after all!
Returns (Gasp!)
We’ve taken a lot of precautions to make sure you never even have to worry
about sending a defective unit back, or sending a unit in for service. But, like
any complex piece of equipment designed and built by humans, once in a while,
something doesn’t go as planned. If you nd yourself with a xture that isn’t
behaving like a good little xture should, you’ll need to obtain a Return Authori-
zation (RA).
and we’ll issue you an RA. Then, you’ll need to send the unit to us using a
trackable, pre-paid freight method. We suggest using USPS Priority or UPS.
Make sure you carefully pack the xture for transit, and whenever possible, use
the original box & packing for shipping.
When returning your xture for service, be sure to include the following:
1.) Your contact information (Name, Address, Phone Number, Email address).
2.) The RA# issued to you
3.) A brief description of the problem/symptoms.
We will, at our discretion, repair or replace the xture. Please remember that
any shipping damage which occurs in transit to us is the customer’s responsibil-
ity, so pack it well!
Shipping Issues
Damage incurred in shipping is the responsibility of the shipper, and
must be reported to the carrier immediately upon receipt of the items.
Claims must be made within seven (7) days of receipt.

Page 18
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
Tech Specs!
Weight & Dimensions
Width 10.7 inches (27 cm)
Depth 5.7 inches (14.4 cm)
Height 8.6 inches (21.8 cm), 11.2 inches (28.4 cm)
including bracket height
Weight 11.5 lbs (5.2 kg)
Power
Operating Voltage AC 100V-264V/47-63HZ
Power Consumption 100W, 1.35A, pf: .6
Light Source
LED 12x 15W 6-in-1 LEDs 100,000 hours.
Optical
Beam Angle 25 degree
Luminous Intensity Lux/m Red Green Blue Amber White UV ALL
1m 2,566 3,054 2,950 1,687 4,730 825 13,700
2m 722 914 885 500 1,276 250 3,900
Thermal
Max. Operating Temp. 104 degrees F (40 degrees C) ambient
Control
Protocol USITT DMX-512
DMX Channels 6 / 7 / 8 / 11
Input 3-pin XLR Male
Output 3-pin XLR Female
Other Operating Modes Standalone, Master/Slave, Color Preset
Other Information
I wonder how they deal with mice at Disney World.
Warranty
2-year limited warranty, does not cover malfunc-
tion caused by damage to LED’s.

Page 19
TOURnado™ IP EXA User Manual Rev. B © Copyright 2014 Blizzard Lighting, LLC
10.7 in (270.1 mm)
6.6 in (166 mm)
8.6 in (218.1 mm)
Dimensional Drawings
11.2 in (283.7 mm)
5.7 in (144 mm)

Enjoy your product!
Our sincerest thanks for your purchase!
--The team @ Blizzard Lighting
Table of contents
Popular Floodlight manuals by other brands

Divine Lighting
Divine Lighting Hyper 361 P user manual

Chalmit lighting
Chalmit lighting Micronex 70W HPS Installation, operation and maintenance instructions

Blizzard Lighting
Blizzard Lighting Puck Fab5 Skywire user manual

Morris
Morris 71531 instruction manual

Martec
Martec MLXR3542MS instruction manual

Intermatic
Intermatic FL150MH installation instructions