TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
TR reserves the right to make
design changes and/or
improvements without notice.
Registered at Medical Products
Agency, Sweden,
as a MD Class 1 product,
MDD 93/42EEC.
Operating Manual
Always study this manual carefully before you attempt to
operate your bathing system.
This bath system is intended for professional use only where
the patient will be under supervision of trained personnel.
Operating instructions and recommended maintenance
procedures are explained in the following pages.
If you have any questions regarding the operation or
maintenance of your bathing system and cannot nd the
answer in this manual, please contact us.
The system is designed for years of trouble free operation,
with proper use and maintenance.
Bathtub and shower water must be run at least every three
days.
Serial Number:
2017-2

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
2
Introduction 3
Product Description, Intended Use and Technical Specications 4
Safety Instructions 6
Features and Controls for TR 900 ,-C, -CW 8
Installation Instructions 9
User Instructions 15
Basic Operating Procedures for the TR 900 Bathtub 15
Cleaning System Operation 17
Whirlpool System Operation 19
Whirlpool System Cleaning 20
LED Color Light System 22
Autoll Controls 23
Patient Handling for the TR 900 Bathtubs 24
Preparing Tub for use 24
Ambulatory Patient Transfer 25
Patient Transfer into tub with TR 9650 Chair Lift 26
Recumbent Patient Transfer, TR 9650 Stretcher Lift 27
System Components 28
Routine Maintenance 29
Labels 30
Maintenance Record 31
Training Record 31
Table of Contents

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
3
Introduction
Dear Customer,
Thank you for choosing one of our quality products. We hope you enjoy the TR 900 height adjustable bathtub.
This manual shall, in conjunction with staff training, ensure that the operator/user is always using and/or operating
the TR 900 correctly.
TR requires that each user has read and understands the entire operating manual and that they can apply the instructions
as specied. This applies to anyone who was not present at the in-service.
This instruction manual should generally be kept easily accessible for every user. Copying the whole of the manual is
encouraged since its sole purpose is to improve the standard of training and safety.
Please order another copy from us if the instruction manual is lost or unusable or if it has become illegible over time.
If you require further information or have any questions please do not hesitate to contact TR or ask one of our
qualied partners.
Please make sure you have read, understood, and applied the information on the following pages.

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
4
Product Description Version Art no
TR 900 TR 900 Hi Lo bathtub 05192150
UK-TMV3 05192151
Germany 05192152
TR 900C TR 900 Hi Lo bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle.
05192160
UK-TMV3 05192161
Germany 05192162
TR 900CW TR 900 Hi Lo bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle and a Whirlpool
system with air control.
05192170
UK-TMV3 05192171
Germany 05192173
Product Description Version Art no
TR 900A TR 900 Hi Lo bathtub 05192155
Germany 05192156
TR 900CA TR 900 Autoll bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle.
05192165
Germany 05192166
TR 900CWA TR 900 Autoll bathtub with a built-in Cleaning system with safety
valve, yellow hose and cleaning shower handle and a Whirlpool
system with air control.
05192175
Germany 05192176
Intended Use
Device Models:
TR 900
TR 900C
TR 900CW
TR 900A
TR 900CA
TR 900CWA
• The device “TR 900” is intended for bathing and showering of patients.
• The patient is typically a person who is unable to take care of their own
personal hygiene.
• The device is not intended to be used with patients that exceeds
a weight of 150 kg/330 Ibs.
• The device is not intended to come in contact with for example wound or injured skin.
• The user is any adult person who is capable of reading and understanding the
operating manual and is qualied to care for dependent persons/patients.
• Before using the device, the user must read and understand the operating manual.
• The device is intended to be used indoors in all types of care facilities and private homes,
including hygiene areas.
This manual includes instructions for the operation of the following equipment:
Product Descriptions, Intended Use and Technical Specications

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
5
Outside length 2 325 mm/92”
Outside width 830 mm/33”
Inside width (head end) 700 mm/28”
Inside width (foot end) 630 mm/25”
Inside width (tub body) 472 mm/19”
Access height 610 mm/24”
Clearance between the
oor and the botton of
the tub
175 mm/7”
Max. total load Individuals weighing no more
than 150 kg/330 Ibs with max
Height settings 610 - 940 mm/24” - 37”
Power supply 230 V, 50 Hz/110 V, 60 Hz
Bathtub body material GRP
Lift stroke 330 mm
Lift speed 13 mm/s
Lifting power actuator 7000 N
Power supply 110 V/60 Hz alt. 230 V/50 Hz
Control voltage 24 V
Overall weight (empty) 265 kg/584 Ibs
Bathtub faucet See thermostat mixer
operating manual
Technical Specications
“TR900” is a height adjustable bathtub. The bathtub can be
raised and lowered within the operating height range.
The height adjustable bathtub TR 900 is designed for
bathrooms in nursing homes, clinics and hospitals and
consists of:
1. The tub and panel are made of glass ber. The bre panel
covering actuator, control units and all internal sanitary
installations.
2. The three-step adjustable foot support is pushed into the
slots to accommodate the different lengths of patients
and to avoid them from sliding and provide secure support
for their feet. The foot support can be removed, for
example when using a stretcher.
3. Overow protection and pop-up drain which opens and
closes the drainage system by rotating the overow valve.
4. The thermostat mixer is designed to regulate the water
temperature to the bathtub lling spout and to the
handheld shower. See separate thermostat mixer
operation manual for further information.
5. The shower handle with shower hose is to be used to
shower the patient and to rinse equipment after cleaning.
6. One linear actuator for height adjustment within the
operating height range.
7. Control buttons and thermometer are located on the
panel.
8. Two legs including adjustable feet if the oor should be
uneven.

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
6
Safety Instructions
This HiLo bathtub may only be operated by qualied and
trained staff.
Please make sure that:
• All safety and operating instructions are read and
understood and that they are adhered to and applied
when using the bath.
• New colleagues must be trained by qualied and
experienced staff.
• The bathtub may only be installed and connected
according to our assembly and installation instructions by
specialists such as a certied electrical installation
company. Local guidelines and regulations as well as
installation rules for water and power connections must be
adhered to.
• Even if you have chosen our company to install the
bathtub, the cold and hot water supply and the electrical
wiring is the buyer’s responsibility.
• Electrical wiring must be carried out on site by a qualied
electrician.
• The bathtub may only be connected to the power supply
via a cord that is connected to a GFCI (ground fault circuit
interrupter) including an easily accessible switch near the
bathtub.
• Maintenance work must be carried out by specialist rms
or trained staff.
• Repairs can only be carried out after consulting the
supplier.
• Repairs shall only be carried out by specialist rms using
original spare parts.
Every time, before the bathtub is used, please make sure that
there are no visible damages/defects such as:
• Cracks in the tub body/side covers
• Damages to the main cord
• Ensure that the bathtub is lowered/raised evenly
• Make sure the tub stands stable
• There are no defects and the thermostat and option
buttons are all working properly
Important: The manufacturer’s warranty and liability
expire automatically if modications or repairs are carried
out or if components are exchanged or opened without the
manufacturers consent.

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
7
Safety Instructions
If you have a question regarding the operation or maintenance
of your TR 900 Bathing System and cannot nd the answer in
this manual, please contact us.
• When using the TR 9650 the patient must be seated
comfortably on the chair and/or stretcher, with safety
belts securely attached. Safety belts must be maintained
in good condition.
• Raise Stretcher/Chair to ensure clearance of all body
parts over the tub. This is to avoid the patient from being
pinched between the tub rim and the Chair/Stretcher
frame during transfer.
• Before raising or lowering the tub, make sure that the
patients hands rmly grasp the stabilizing bar or that the
patients arms are crossed over his/her body. This is to
avoid pinched arms or ngers between the
Stretcher/Chair frame and the tub rim.
Warning: Always disconnect electric power before
attempting any service or repair.
• Wipe beneath Stretcher/Chair to prevent water dripping
on the oor.
• Always physically check water temperature before and
during bathing/ showering to ensure that the
thermoscopic mixer is functioning.
The thermostatic mixing valves are fully performance
tested individually and the maximum temperature is
factory preset at approximately 43°C under ideal
installation conditions at the factory.
• Make sure that all parts that come in contact with the
patient are intact and without sharp edges.
• Check that hoses, tub controls, connections, mixer and
thermometer are free from damage.
Warning: Never leave a patient unattended.

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
8
Features and Controls for TR 900 ,-C, -CW
Bathtub height adjustment and lling
1Bathtub up/down control buttons
2Thermostatic mixer
3Thermometer
4On-off valve for bathtub lling
5Bathtub lling spout
6Bathtub overow drain
Drain-close/open
8Adjustable footrest, two positions
Patient shower
2Thermostatic mixer
3Thermometer
9On-off valve for patient shower
10 Patient shower hose
11 Patient shower handle
12 Handle bracket
Whirlpool system (W)
20 Motor control on/off for whirlpool
21 Adjustable whirlpool jet
22 Air control valve
23 Whirlpool inlet safety screen
8
Cleaning system (C)
13 Shut-off safety valve
14 Spray equipment hose
15 Spray handle
16 Spray handle bracket
17 Mixing setting screw
(inside the panel)
18 Detergent lling lid
19 Yellow cleaning adapter,
for Whirlpool

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
9
Bathroom layout
Recommended room size 2400 x 3000 mm, or larger.
Plumbing rough - in
Pipe, hoses and ttings, to and from bath connections
including backow preventors (check valves), shut- off valves
and lters, to be supplied and installed by others and to
comply with local building and plumbing regulations.
To eliminate pipe debris it is essential that supply pipes are
thoroughly ushed before connection of the bathtub.
The bathtub drainage shall be connected to oor or wall
drainage. To level the legs adjust the feet.
The TR installation set art no. 05193010 and 05193020
includes: check valves, valves with strainers and exible
hoses of 50 cm. Avoid any kinks on the hose curve when
bending.
Bathtub with autoll: Set the shower ow rate by adjusting
the ball-valve inside the panel located on the shower piping.
Installation Instructions
Weight lled 500 kg/1102 Ibs
Weight empty 250 kg/551 Ibs
Water volume 250 liters
Water pressure
2 - 6 bar. Inlet dynamic pressures
nominally balanced to within 10 % of each
other during ow
Flow rate 6 - 120 l/min
Hot water
temperature
65 C. Differential of approx. 50 degrees
between hot and cold water inlet
temperatures.
Drainage 100 l/min
Electrical rough - in
Standard electrical requirements: 230 V, 50 Hz, 10 Amps.
Permanent connection installed by others.
Note: All electrical conduit, tting and wire to bath supplied
and installed by your professional electrician in accordance
with local or applicable electric code as a minimum
requirement. Main switch with signal lamp, main fuse and
earth circuit breaker are not included and must be supplied by
others.
The SKF actuators are specied for 230/120 V AC +- 10 %.
If end user is using a power source which generates peeks
outside those norms, then they should use a line lter
(capacitor + choke) to regulate it.
Warning: Polarity and grounding must be correct.
Improper connection may result in injury.

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
10
Floor Drainage
Mount the bracket for the drainage pipe to the front of the
panel. Adjust by cutting the length of the pipe.
Wall Drainage
Mount the bracket for the drainage pipe to the back of the
panel.
Installation Instructions

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
11
Installation drawing TR 900 with SKF actuators
For more information contact us:
info@trequipment.se
+46 140 38 50 60
Installation Instructions

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
12
Installation drawing TR 900 with SKF actuators
For more information contact us:
info@trequipment.se
+46 140 38 50 60
Installation Instructions

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
13
Installation drawing TR 900 with Linak actuators
For more information contact us:
info@trequipment.se
+46 140 38 50 60
Installation Instructions

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
14
DRAIN
DRAINAGE
EL. CONN.
CW DESINF. R15
HW R20
CW R20
200
110
60
160
200
80
530
Installation drawing TR 900 with Linak actuators
For more information contact us:
info@trequipment.se
+46 140 38 50 60
Installation Instructions

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
15
Basic Operating Procedures for the TR 900 Bathtubs
Use the following controls for lling tub and showering
patients. The Whirlpool and cleaning system are described
separately, see page 17-21.
Controls
The TR 900 Bathing System control panel and bathtub are
made of glass bre. It has a thermostatic mixer (2) for the
bathtub lling and the patient shower.
The thermostatic mixer regulates water valve temperature for
the bathtub ll and the patient shower.
To calibrate the thermostatic mixer, see enclosed product
manual from the manufacturer.
In addition, there are shut-off valves for the tub ll (4) and
patient shower (9).
The thermometer (3) measures bathtub lling water and
patient shower temperature in °C (Celsius).
The temperature probe is located close to the thermostatic
mixer (2) to provide an accurate reading of water temperature
as the bathtub lls.
By monitoring the thermometer you can precisely regulate
water temperature with use of the thermostatic mixer (2) as
the tub lls or when the patient shower (11) is used.
Height of the tub is adjusted with the tub up/down controls
(1). The tub can be adjusted to any level from 600 mm (24”)
to 1000 mm (40”) above the oor.
To lower the tub, press and hold the down button (1). To raise
the tub, press and hold the up button (1).
When releasing the up or down buttons the bathtub stops in
desired height position.
User Instructions

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
16
Basic Operating Procedures for the TR 900 Bathtubs
Shower System Operation
The patient shower includes a handle (11) located on the right
side on the panel, the thermoscopic mixer (2) and a shut-off
valve (9) on the front of the control panel.
The handle nozzle has a rubber strainer which is easy to
clean, just rub your thumb over the strainer.
Using the shower:
1. Lift the shower handle (11) and hold it over tub, away
from patient.
2. Turn valve (9) to “ON” position for patient shower.
3. Set the thermoscopic mixer (2) to desired temperature.
4. Physically test water temperature and adjust
thermoscopic mixer (2) to suit. Adjust water ow with
shut-off valve (9) located on front of control panel.
5. Shower or rinse patient with shower handle.
6. After showering, turn valve (9) to ”OFF” position
7. Return the handle (11) to its bracket (12)
Note: To avoid water dripping on the oor empty the shower
hose by holding the handle over the bathtub for some
seconds.
The patient shower system is also useful for rinsing residue
and debris from the tub when cleaning (see cleaning system
description, see page 17-18).
Note: Shower handle shall not be held in the bath water while
bathing.
Whirlpool
The shower hose shall be used when ushing the whirlpool
system, see separate description, see page 19-21.
User Instructions

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
17
Cleaning System Operation
The cleaning detergent is mixed with cold water to minimize
inhalation.
The cleaning spray handle (15) on the yellow hose is located
on the side of the control panel in a bracket (16).
Water ow is controlled by a shut-off safety valve (13) with a
key, located on the left end wall of the control panel.
Detergent is automatically mixed with the water, in a pre-set
concentration of appr. 2 %, controlled by a mixing setting
screw (17) on the injector inside the panel. When a various
calibration setting is required see next page.
Daily use of the cleaning system:
1. Remove the cleaning spray handle (15) from bracket (16).
Hold the handle over the bathtub while opening the
shut-off safety valve (13) with the special key.
2. Briey spray the cleaning mixture into the tub while
checking the color, smell and the foam of the mixture.
Spray over all interior surfaces of the tub. Remove residue
and debris with cloth or brush.
3. To clean TR Chair Lift and Stretcher Lift, position them
over the tub and spray them with cleaning mixture.
The Chair and Stretcher have removable pads and the
Stretcher has a head pillow which can be placed in the
tub for cleaning.
4. After cleaning, rinse with fresh water using the shower
handle on the right side of the control panel.
Detergent lling
Open the lid (18) on top of the panel and ll with maximum
1.5 litre of concentrated detergent.
Warning: Avoid skin or eye contact with
cleaning/detergent, which can be highly corrosive.
If contact is made, rinse immediately with excess water. If
irritation occurs, consult a doctor. Always read and follow
detergent supplier directions carefully.
Important: Never to be used on patients.
Only on equipment.
User Instructions

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
18
Cleaning System Operation
Calibrating the detergent mixture of the Cleaning System
Detergent is automatically mixed with the cold water, in a
pre-set mixture, at the factory, of 2 %.
If an alternatively calibration is needed follow the instructions
below to achieve a mixture of 2 % or what is recommended by
your detergent supplier.
To calibrate the mixing setting screw (17) placed on the
injector inside the panel, requires a thin screwdriver, a
measuring cup with a capacity of at least 20 cl, and a bucket
with at least 10 liters capacity.
A. Remove the back panel cover.
B. Empty the detergent bottle by loosening the hose from
the injector. When empty, connect the hose to the injector
again.
C. Fill the measuring cup with 20 cl concentrated detergent,
open the detergent bottle lid (18) and pour it into the
bottle.
D. Place the empty 10 liter bucket in the tub and hold the
cleaning spray handle (15) with yellow hose over the
bucket for lling.
E. Open the cleaning key-grip safety valve (13) to full open
position and spray into the bucket.
F. Observe level when bucket lls, while bottle empties.
Bucket should reach 10 liter mark at the same time as
the bottle empties. If bucket lls rst, turn the detergent
mixing setting screw (17) on injector slightly counter
clockwise, using the screwdriver. If bottle empties rst,
turn the detergent mixing setting screw (17) slightly
clockwise.
G. Repeat procedure A-F until the mixture is as required.
H. Close cleaning key-grip safety valve (13), and return the
cleaning handle (15) to the bracket (16) on side of the
panel.
I. Attach the back panel cover.
The cleaning system is now ready for use. See detergent lling
on previous page.
Once the proper mixture setting is established, no further
calibration is required unless a different detergent, is used.
Note: Mixture should be calibrated in accordance to your
detergent supplier.
User Instructions

Hygiene Equipment
Designed for People
Hygiene Equipment
Designed for People
Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
19
Whirlpool System Operation
TR whirlpool system allows you to regulate both water ow
directions and quanity of air.
Using the whirlpool system
1. Turn the adjustable whirlpool outlet jet (21), located at the
drain end of the tub, anti-clockwise to full open position.
2. Fill the bathtub making sure that the water level
covers the outlet jet (21). Also, ensure that the whirlpool
inlet screen (23) is in place.
3. Set the adjustable whirlpool outlet jet (21) for desired ow
direction: centred for perineal area; to either side for
circular ow. The adjustable jet rotates in a friction
housing and is easily turned to the desired position.
Avoid placing the jet in a full upward position, as this
could cause the water to splash.
4. With the patient in the bathtub, turn on the whirlpool unit
by pushing the ”ON-OFF” control button (20) on the
control panel. Make sure the whirlpool inlet screen (23)
is not obstructed so that full ow is maintained.
5. To make any further adjustments in water ow direction,
change the adjustable whirlpool outlet jet (21).
6. Increase or decrease whirlpool stream by turning the air
control (22).
7. Turn the whirlpool unit off by pushing the ”ON-OFF”
control button (20) on the control panel.
Note: If the whirlpool motor starts without any jet stream in
the bathtub, please make sure that the adjustable whirlpool
outlet jet (21), located at the drain end of the tub is fully open.
It is not, turn it counter clockwise to full open position. Make
sure that the control screen (23) is in place. Do not start the
pump if the screen is missing.
Warning: Disconnect electric power before attempting any
service or repair.
Warning: Always physically check water temperature
before and during bathing/showering to ensure that the
thermoscopic mixer is functioning.
User Instructions

Head Ofce
TR Equipment AB, Sweden
Phone: +46 140 38 50 60
info@trequipment.se
www.trequipment.com
Group Subsidiaries
TR Group Inc, US, Phone: +1 (800) 752 6900
TR Equipment Ltd, UK, Phone: +44 (0) 844 335 8386
TRanspoRehaMed GmbH, Germany, Phone: +49 (0) 212 645850-0
Hygiene Equipment
Designed for People
TR 900
Height Adjustable Bathtub
Hygiene Equipment
Designed for People
20
Whirlpool System Cleaning
Clean the whirlpool system
A tailor made yellow whirlpool inlet cleaning adapter (19) for
the whirlpool system is delivered separately with the
TR 900 CW. This is to be stored on top of the detergent lling
lid (18).
1. Turn the adjustable whirlpool outlet jet (21), located at
the drain end of the tub, counter clockwise to full open
position.
2. Remove the whirlpool inlet safety screen (23) by turning
the screen counter clockwise.
3. Fit in the yellow adapter (19) which is placed on top of the
detergent lling lid (18), to the whirlpool inlet (24).
4. Remove cleaning shower handle (15) from yellow cleaning
hose (14) by pressing the dots on the quick coupling.
5. Snap the hose with its coupling onto the adapter and
ush cleaning through the system by turning the cleaning
”key” (13) on the side of the panel.
6. Cleaning mixture will ush out through the whirlpool outlet
(21) into the tub.
7. When this is done, turn cleaning system off and repeat
procedure with patient shower hose (10) to ush system
with fresh water.
8. Return the yellow adapter (19) onto the top of the
detergent lling lid (18).
Safety and Control Instructions
• Ensure that the bottle is lled with detergent
• Never use cleaning shower handle on patients because
detergent is highly corrosive. The hose is placed opposite
the patient shower to prevent misuse.
• Equipment must be cleaned after each use
Warning: Avoid skin or eye contact with detergent, which is
highly corrosive. If contact is made, rinse immediately with
excess water. If irritation occurs, consult a doctor. Always
read and follow detergent supplier instructions.
User Instructions
This manual suits for next models
5
Table of contents
Popular Plumbing Product manuals by other brands

ShowHouse
ShowHouse Savvy TS497BB Replacement parts

Hans Grohe
Hans Grohe Ecostat E 15708 Series Instructions for use/assembly instructions

Delabie
Delabie 54 Series manual

Sunlighten
Sunlighten mPulse Aspire user manual

noken
noken City 100090014 Installation and Maintenance

Kohler
Kohler PureWarmth K-10349-96 Installation and care guide

Reece
Reece SUSSEX POL manual

Kohler
Kohler Stillness 979T-4 installation instructions

American Standard
American Standard Colony Soft 2175.500 installation instructions

Hans Grohe
Hans Grohe AXOR Citterio E 36701180 Instructions for use/assembly instructions

Gessi
Gessi JUST 37281 manual

Grohe
Grohe 31 041 manual