Transcension HS2 Hybrid Distribution Splitter User manual

Order code: BOTE73
HS2 Hybrid PowerCON
DMX Distribution Splitter
User Manual

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available mains supply voltage
is 240V AC, 50Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This xture is for professional use only - it is not designed
for or suitable for household use. The product must be
installed by a qualied technician in accordance with local
territory regulations. The safety of the installation is the
responsibility of the installer. The xture presents risks of
severe injury or death due to re hazards, electric shock
and falls.
• WARRANTY: One year from date of purchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 3
Product overview & technical specications
A combination 2 way DMX booster/distributor featuring
one input and two outputs plus PowerCON power input
with two PowerCON power outputs. Both DMX input and
DMX output are provided with 5-Pin XLR connectors,
each DMX output has an independent driver.
• 2 way DMX distributor with one input and two outputs
• 5-Pin XLR input
• 5-Pin XLR output per channel
• Each DMX output features an independent driver
• 100% electrical isolation between all inputs/outputs
• 2 way PowerCON power distributor with one input and two outputs
• M10 rigging point
• Safety bond point
• Rugged, steel chassis
HS2 Hybrid PowerCON DMX Distribution Splitter
Specications
Power supply 240V, 50Hz
Fuse F1A 250V
Dimensions 61 x 160 x 175mm
Weight 1.1kg
Order code BOTE73
HS2 Hybrid PowerCON DMX Distribution Splitter
DMX OUTPUT 1
DMX
OUTPUT
DC
POWER OUTPUT 1:
240V~50Hz
POWER OUTPUT 2:
240V~50Hz
MAX. 20A TOTAL LOAD
POWER INPUT:
240V~50Hz
DMX INPUT
FUSE:
F1A 250V
DMX OUTPUT 2
DMX
OUTPUT
DC
61mm
150mm
175mm
160mm

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 4
01 - 2 x 5-Pin DMX outputs
02 - 5-Pin DMX input
03 - DC/DMX output indicators
04 - PowerCON input
05 - PowerCON outputs
06 - Fuse: F1A 250V
07 - Earth point
08 - Safety eye
09 - M10 rigging point
In the box: 1 x HS2
distribution splitter,
1 x power cable
& 1 x user manual
Technical specications
HS2 Hybrid PowerCON DMX Distribution Splitter
DMX OUTPUT 1
DMX
OUTPUT
DC
POWER OUTPUT 1:
240V~50Hz
POWER OUTPUT 2:
240V~50Hz
MAX. 20A TOTAL LOAD
POWER INPUT:
240V~50Hz
DMX INPUT
FUSE:
F1A 250V
DMX OUTPUT 2
DMX
OUTPUT
DC
0406
1002 07 01 0309
05

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 5
DMX Controller240V Mains input
Operating instructions
Setup:
Connect a DMX signal cable from a lighting console or xture into the DMX Input via the 5-Pin male
connector on the side panel. The HS2 has 2 outputs each with a 5-pin XLR connector for each DMX
output. From each DMX output a signal cable may be connected with up to 32 xtures per signal line,
and up to 100m cable length. Connect the HS2 to a suitable 240VAC 50Hz mains supply via the
PowerCON mains inlet.
LED indicators:
The HS2 is tted with signal and DC indicators. Under normal conditions, with DMX signal passing
through the unit both LEDs will be illuminated. The DMX LED indicates the presence of a DMX signal.
The DC LED indicates the DMX drive circuit is functioning correctly.
Example connection diagrams:
POWER OUTPUT 1 DMX OUTPUT 2
DMX INPUT
POWER INPUT
DMX OUTPUT 1 POWER OUTPUT 2

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 6
DMX setup
Further DMX cables can be
purchased from all good sound
and lighting suppliers or
Pro Light Concepts dealers.
Please quote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 512. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the
chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,
see image below.
Also remember that DMX cable must be daisy chained and cannot be split.

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 7
Termination reduces signal transmission
problems and interference. It is always
advisable to connect a DMX terminal,
(resistance 120 Ohm 1/4 W) between pin 2
(DMX-) and pin 3 (DMX+) of the last xture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Notice:
Be sure to follow the diagrams below when making your own cables. Do not connect the cables
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special note:
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

www.prolight.co.uk HS2 Hybrid Distribution Splitter User Manual 8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally