TransLite TL-9524C-4 User manual

P a g e | 1
DISCLAIMER
No part of this document may be reproduced in any form without the written permission of the copyright
owner.
The contents of this document are subject to revision without notice due to continued progress in
methodology, design and manufacturing. TRANSLITE GLOBAL LLC shall have no liability for any error or
damage of any kind resulting from the use of this document.
COPY WARNING
This document includes some confidential information. Its usage is limited to the owners of the
product that it is relevant to. It cannot be copied, modified, or translated in another language
without prior written authorization from TRANSLITE GLOBAL LLC
PRODUCT MODEL NUMBER: TL-9524C-4 4-CHANNEL
ENCODER MODULATOR
ABOUT THIS MANUAL

P a g e | 2
INDEX
TABLE OF CONTENTS
CHAPTER 1 INTRODUCTION...........................................................................................................3
1.1 PRODUCT OVERVIEW ...................................................................................................... 3
1.2 KEY FEATURES................................................................................................................. 3
1.3 SPECIFICATIONS.............................................................................................................. 4
1.4 PRINCIPLE CHART ........................................................................................................... 6
1.5 APPEARANCE AND DESCRIPTION.................................................................................. 7
CHAPTER 2 INSTALLATION GUIDE...........................................................................................................9
2.1 GENERAL PRECAUTIONS................................................................................................. 9
2.2 POWER PRECAUTIONS.................................................................................................... 9
2.3 DEVICE’S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING ....................... 9
2.4 ENVIRONMENT REQUIREMENT..................................................................................... 10
2.5 GROUNDING REQUIREMENT......................................................................................... 10
CHAPTER 3 OPERATION........................................................................................................................ 11
3.1 LCD MENU STRUCTURE................................................................................................. 12
3.2 GENERAL SETTINGS ...................................................................................................... 13
CHAPTER 4 WEB NMS OPERATION.......................................................................................................21
4.1 LOGIN .............................................................................................................................. 21
4.2 OPERATION..................................................................................................................... 22
CHAPTER 5 TROUBLESHOOTING........................................................................................................... 31
CHAPTER 6 PACKING LIST..................................................................................................................... 32
CHAPTER 7 APPLICATIONS ................................................................................................................... 32

P a g e | 3
CHAPTER 1
INTRODUCTION
1.1 PRODUCT OVERVIEW
TL-9524C encoder modulator is Translite’s all-in-one device integrating MPEG2 encoding and
modulating to convert audio/video signals into DVB-C/T/ATSC/ISDB-T/DTMB RF out. It
supports 1/4/8 HDMI inputs, and its pay-as-you-grow modular design and flexible configuration
are making it extremely scalable, and very reliable with high performance. The signals source
could be from STB, satellite receiver, closed-circuit television cameras and antenna etc. Its
output signal is to be received by TVs or STBs etc.
1.2 KEY FEATURES
➢Support 1/4/8 HDMI channels input
➢Support MPEG2 video encoding
➢Support 1080p/i,720p, 576i, 480i video resolution
➢Support low latency(50~1000ms)
➢Support MPEGI layer 2, MPEG-2 AAC, and DD AC3 audio encoding
➢Support CC (Closed Caption), EIA 608
➢Support LCN (Logical Cluster Number)
➢DVB-C/T/ATSC/ISDB-T/DTMB RF out in one device, Modulation dynamic switching
➢Each channel supports 1 DVB-C/T/ATSC/ISDB-T/DTMB output option
➢Control via web-based NMS, and easy updates via web

P a g e | 4
1.3 SPECIFICATIONS
HDMI Encoding Section
Input
Interface
HDMI*4/8
Encoding
MPEG2
Video
Input
Output
480@59.94/60i
480@30p
576@50i
576@25p
720@50/59.94/60p
720@25/30p
1080@50i
1080@25p
1080@59.94/60i
1080@30p
1080@50p
1080@25p
1080@59.94/60p
1080@30p
Audio
Encoding
MPEGI layer 2, MPEG-2AAC, AC3
Sample rate
48KHz
Bit rate
MPEGI layer 2 (128kbps)
MPEG-2 AAC (VBR)
AC3 (128kbps)
DVB-C Modulator Section
Standard
J.83A (DVB-C), J.83B
MER
≥35dB
RF frequency
100-1000MHz, 1KHz step
RF output level
-48~ -10dBm, 1dB step
Symbol rate
3.000~7.000Msps adjustable
J.83A
J.83B
Constellation
16/32/64/128/256QAM
64/ 256QAM
Bandwidth
8M
6M

P a g e | 5
DVB-T Modulator Section
Standard
DVB-T COFDM
Bandwidth
2M, 3M, 4M, 5M, 6M, 7M, 8M
Constellation
QPSK, 16QAM, 64QAM
Code rate
½, 2/3, ¾, 5/6, 7/8
Guard Interval
1/32, 1/16, 1/8, ¼
Transmission Mode:
2K, 8K
MER
≥35dB
RF frequency
100-1000MHz, 1KHz step
RF output level
-48~ -10dBm, 1dB step
ISDB Modulator Section
Standard
ARIB STD-B31
Constellation
QPSK, 16QAM, 64QAM
Guard Interval
1/32, 1/16, 1/8, ¼
Transmission Mode
2K, 4K, 8K
Code rate
½, 2/3, ¾, 5/6, 7/8
RF frequency
100~1000MHz, 1KHz step
RF output level
-48 ~ -10dBm, 1dB step
ATSC Modulator Section
Standard
ATSC A/53
Constellation
8 VSB
MER
≥35dB
RF frequency
100 ~ 1000MHz, 1KHz step
RF output level
-48 ~ -10dBm, 1dB step

P a g e | 6
DTMB Modulator Section
RF frequency
100-1000MHz, 1KHz step
RF output level
-48 ~ -10dBm, 1dB step
Transmission Mode
S-0.8-4QAM-595, S-0.8-16QAM-595,
M-0.4-16QAM-945V,M-0.6-16QAM-945V,
M-0.6-64QAM-420V, M-0.6-64QAM-945V,
M-0.8-16QAM-420V, M-0.8-16QAM-945V,
M-0.8-64QAM-420V
System
Management
Web
Language
English
Upgrade
Web update
General
Power supply
AC 100V±10%, 50/60Hz or AC 220V±10%, 50/60Hz
Dimensions
482*328*44.5mm
Temperature
0~45℃(operation),
-20~80℃(storage)
1.4 PRINCIPLE CHART
Please refer to the principle chart below:

P a g e | 7
1.5 APPEARANCE AND DESCRIPTION
Front Panel Illustration
1 2 3 4 5 6 7

P a g e | 8
1
LCD screen
2
Indicators
Power Indicator
Status Indicator
CH1-CH4/8 indicates the 4/8 channels input
3
UP/ DOWN, LEFT/RIGHT keys
4
Enter key
5
Menu key
6
Lock key
7
NMS (Network management port)
Rear Panel Illustration
1 2 3 4
1
RF output
2
8 HDMI input and 8 CC input ports
3
Power Switch/Fuse/Power socket
4
Grounding Pole

P a g e | 9
CHAPTER 2
INSTALLATION GUIDE
This section is to explain the cautions the users must know in some case that possibly injure
may bring to users when it’s used or installed. For this reason, please read all details here and
make in mind before installing or using the product.
2.1 GENERAL PRECAUTIONS
➢Must be operated and maintained free of dust or dirty.
➢The cover should be securely fastened, do not open the cover of the products
when the power is on.
➢After use, securely stow away all loose cables, external antenna, and others.
2.2 POWER PRECAUTIONS
➢When you connect the power source, make sure if it may cause overload.
➢Avoid operating on a wet floor in the open. Make sure the extension cable is in
good condition
➢Make sure the power switch is off before you start to install the device
2.3 DEVICE’S INSTALLATION FLOW CHART
ILLUSTRATED AS FOLLOWING
Connecting
Grouding
Wire and
Power
Cord
Acquisition
Check Installing
Device Setting
Parameter Running
Device
Connecting
Signal
cable

P a g e | 10
2.4 ENVIRONMENT REQUIREMENT
Item
Requirement
Machine Hall
Space
When user installs machine frame array in one machine hall, the distance
between 2 rows of machine frames should be 1.2~1.5m and the distance
against wall should be no less than 0.8m.
Machine Hall
Floor
Electric Isolation, Dust Free
Volume resistivity of ground anti-static material: 1X107~1X1010,
Grounding current limiting resistance: 1M(Floor bearing should be
greater than 450Kg/㎡)
Environment
Temperature
5~40℃(sustainable),0~45℃(short time)
installing air-conditioning is recommended
Relative
Humidity
20%~80% sustainable 10%~90% short time
Pressure
86~105KPa
Door &
Window
Installing rubber strip for sealing door-gaps and dual level glasses for
window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire
Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting power are
independent toeach other. Devicepower requiresAC 110V±10%, 50/60Hz
or AC 220V±10%, 50/60Hz. Please carefully check before running.
2.5 GROUNDING REQUIREMENT
➢All function modules’ good grounding is the basis of reliability and stability of devices. Also,
they are the most important guarantee of lightning arresting and interference rejection.
Therefore, the system must follow this rule.
➢Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.

P a g e | 11
➢Users shouldmake sure the 2 ends of grounding wire well electric conducted and be antirust.
➢It is prohibited to use any other device as part of grounding electric circuit
➢The area of the conduction between grounding wire and device’s frame should be no less
than 25mm2.
CHAPTER 3
OPERATION
TL-9524C encoder modulator’s front panel is user operating interface. Before operating, user
can decide whether directly use the default setting or customize the input and output
parameters setting. The detail operations go as follows:
Keyboard Function Description
ENTER: Activating the parameters which need modifications or confirming the change after
modification.
MENU: To cancel presently entered value, resume previous setting and return to previous
menu.
LEFT/RIGHT: To move the “►” to choose or set the parameters.
UP/DOWN: To modify activated parameter or page up/down when parameter is inactivated.
LOCK: To Lock the screen / cancel the lock state. After pressing lock key, the system will
question the users to save present setting or not. If not, the LCD will display the current
configuration state.
At the “Factory Configuration” page, user can press “ENTER” key to restore the factory default
configuration.

P a g e | 12
3.1 LCD MENU STRUCTURE
An Overview of the LCD Menus
Switch On
1 Status 1.1 Channel 1
1.8 Channel 8
Video Format
Encoding Status
Same Contents as Channel1
(Please refer to the next page…)

P a g e | 13
3.2 GENERAL SETTINGS
By pressing LOCK key, users can enter in the main menu and set the parameters in the
following editing interfaces, the LCD will display the following pages:
►1 Status
2 TS Config
3 Encode
4 Modulate
5 Network
6 System Setting
7 Soft Version

P a g e | 14
The option with “►” is the current selection, users can press the ENTER key to enter the
specified submenu to modify the parameters.
3.2.1 Status
Under this menu, users can check input source status of each channel. The contents are the
same for Channel 1-8, so here just takes one channel as the example.
➢Channel 1/2/3/4/5/6/7/8
3.2.2 TS Config
This device is equipped with maximum 8 modulator carriers. Under this menu, users can enter
the corresponding channels to set the relevant parameters. The setting principle is the same for
Channel 1-8, so here this manual just takes one channel as the example to explain. After
pressing the enter key, the LCD will display the following pages:
►2.1 Channel 1
2.2 Channel 2
2.7 Channel 7
2.8 Channel 8
►1.1 Channel 1
1.2 Channel 2
1.7 Channel 7
1.8 Channel 8
►Video Format
Encoding Status
Display input video resolution
Display encoding status: Error/Normal

P a g e | 15
➢Channel 1/2/3/4/5/6/7/8
TL-9524C supports 8 Channels output with DVB-C, DVB-T, ATSC, DTMB or ISDB-T
modulating. Users select different modulating modes for each channel under the menu of “3.2.4
Modulate”, the TS parameters will be different, LCD will display the following pages:
Selecting modulation mode as DVB-C:
DVB-C has 2 standards, selecting standard as J.83A, LCD will display the following pages:
Selecting standard as J.83B, LCD will display the following pages:
Selecting modulation mode as DVB-T/ DTMB, the LCD contents are the same as DVB-C
(J.83A).
Selecting modulation mode as ATSC, the LCD contents are the same as DVB-C (J.83B).
Selecting modulation mode as ISDB-T, the LCD will display the following pages:
►Network ID
Version Num
LCN Mode
LCN
Channel List ID
Private Data
Channel List Name
TS ID
ON ID
►Major Channel
Minor Channel
Source ID
Channel TSID
Short Name

P a g e | 16
3.2.3 Encode
This device is equipped with maximum 8 HDMI channels input. Under this menu, users can
enter the corresponding channels to set the relevant encoding input parameters.
➢Channel 1/2/3/4/5/6/7/8
The setting principle is the same for Channel 1-8, so here this manual just takes one channel as
the example to explain. After pressing the enter key, the LCD will display the following pages:
►Network ID
Version Num
Key ID
Area Code
TS Name
Service ID
Trans Type Info
TS ID
ON ID
►2.1 Channel 1
2.2 Channel 2
2.7 Channel 7
2.8 Channel 8

P a g e | 17
3.2.4 Modulate
TL-9524C supports up to 8 RF out carriers, users can enter the corresponding channels to
select modulation mode and set the relevant RF output parameters.
➢Channel 1/2/3/4/5/6/7/8
Users can set these parameters by pressing ENTER to enter these submenus. The LCD will
display the following pages
►Video Bitrate
Audio format
GOP
Latency
CC Switch
Program Number
Program Provider
Program Name
PMT PID
Video PID
Audio PID
►4.1 Channel 1
4.2 Channel 2
4.7 Channel 7
4.8 Channel 8
Audio format: MPEG-1
Layer2; AC3; MPEG-2 AAC
Users can’t set these
parameters under ATSC and
DVB-C (J.83B) modulation
modes.

P a g e | 18
DVB-C:
DVB-T:
►Modulate Mode
RF Enable
Freq
Level
Symbol Rate
Standard
Constellation
►Modulate Mode
RF Enable
Freq
Level
Symbol Rate
Bandwidth
Constellation
FFT
Guard Interval
Code Rate

P a g e | 19
ATSC:
DTMB:
ISDB-T:
►Modulate Mode
RF Enable
Freq
Level
Constellation
FFT
Guard Interval
Code Rate
Time Interleaving
►Modulate Mode
RF Enable
Freq
Level
►Modulate Mode
RF Enable
Freq
Level
Mode

P a g e | 20
3.2.5 Network Setting
After enter Network Setting, there are four submenus shows as the following LCD displays.
3.2.6 System setting
➢Save
Users can enter Saving Configuration submenu for saving settings. Choose yes and
press ENTER to confirm.
➢Restore
At this menu, user can choose yes to restore the device into the last saved configuration.
IP Address
192.168.000.136
Subnet Mask
255.255.255.000
Gateway
192.168.000.001
MAC Address
xx:xx:xx:xx:xx:xx
Load Saved CFG?
►YES NO
Saving Config
►YES NO
Table of contents
Other TransLite Modulator manuals