Transtech iPOSTER P2.5 User manual

Made-in-China
World-Class Quality
Edition No:TRT-MKT-2016/03
www.trtled.com
:
:
:
USER MANUAL
4
iPOSTER
Indoor series:P2.5/P1.9

1
Index ························································································································································ 1
Safety information ······························································································································· 2
Specification ·········································································································································· 7
Installation ··········································································································································· 10
Serviceability ······································································································································· 11
Accessories ·········································································································································· 12
Package ················································································································································· 15
Control system ··································································································································· 16
Maintenance & Repair ····················································································································· 63
Index

2
The following symbols are used to identify important safety information on the
product and in this manual:
Safety information:
WARNING!
Read the safety precautions in the section before installing,
powering, operating or servicing this product.
WARNING!
Safety hazard.
Risk of severe
injury or death
WARNING!
Refer to
manual before
installing,
powering or
servicing
WARNING!
Hazardous
voltage Risk of lethal
or severe electric
shock
WARNING!
Hot surface
Do not touch
WARNING!
Fire hazard
WARNING!
Emission
Hazardous to
eyesight
This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to fire
hazards, electric shock and falls.
Read this manual before installing, powering or servicing this
product, follow the safety precautions listed below and observe all
warnings in this manual and printed on the product.
If you have questions about how to operate the panel safely, please
contact your Radiant supplier.

3
PROTECTION FROM ELECTRIC SHOCK
﹡Connect the product to AC mains power within the range 90-264V
nominal at 50 or 60 HZ only.
﹡Disconnect the product from power when not in use.
﹡Always ground (earth) the product electrically
﹡Before using the product, check that all power distribution
equipment and cables are in perfect condition and rated for the
current requirements of all connected devices.
﹡Do not use the product if the power cable or a power plug is in any
way damaged, defective or showing signs of overheating.
﹡Do not attempt to open any cover.
﹡Refer any service operation not described in this manual to a
qualified technician.
PROTECTION FROM FIRE
Do not stick filters, masks or other material directly onto LED
models.
Do not modify the product in any way not described in this manual.
Install only genuine Radiant parts in or on the product unless an
alternative is described in this manual.
Do not operate the product full load if the ambient temperature of
power units exceeds 60°C(156°F)
LOAD (%)
AMBIENT TEMPERATURE(°C)

4
Important warnings
Maximum and minimum ambient temperature:
The maximum ambient temperature of iPoster is 50℃; the minimum temperature is
-20℃. The operation humidity is 10—90%RH.
High leakage current:
The combination of power boxes in an installation results in increased levels of
Leakage current.
In order to avoid risk of electric shock due to high leakage current, proper grounding
of the installation is required.
Risk of electric shock/ Risk of fire.
This equipment MUST be earthed:
In order to protect against risk of electric shock, the installation should be properly
grounded.
Defeating the purpose of the grounding type plug will expose you to the risk of
electric shock.
Power system
Main cords:
The power cords delivered with this system have special properties for safety. They
are not user Serviceable. If the power cords are damaged, replace them only with new
ones. Never try to repair a power cord.
PROTECTION FROM INJURY
Created an installation by installing panels at the top and working
downwards. Disassemble an installation by removing panels at the
bottom and working upwards.
Check that all external covers and rigging hardware are securely
fastened.
Block access below the work area and work from a stable platform
whenever installing, servicing or moving the product.

5
Data cables:
The data cables provided with this system have special properties for safety. They are
not user serviceable. If the data cables are damaged, replace them only with new ones.
Never try to repair a data cable. Per requirements of the National Electrical Code in
the USA, the length of a data cable must not exceed 100m (332feet). Avoid exposure
of data cables to accidental contact with lightning or power conductors.
IPoster cannot be hot swapped:
Always disconnect the power cord from the control box before connecting or
disconnecting the cable string or one of the iPoster. Any damages caused by
hot-plugging are not included in the repair guarantees of the manufacturer.
Compatible power cord specifications:
•3-pin
•Rated current: 10A
•By referring to the table below, choose the right plug type and a power cord that is
suitable for your voltage.
Plug type
North American
European
continental
U.K.
Japanese
China
Plug shape
Region
U.S.A./Canada
EU(except U.K.)
U.K.
Japan
China
Voltage
120
230
230
100
220
Safety guidelines
Personal protection
You need to take particular care of suspended loads and wear a safety helmet to avoid
injuries. While assembling heavy objects, take particular care of your hands.
The relevant legal electric requirements of the country, where the system will be
mounted, installed and operated, must be followed as well as the existing regulations
of the operator, such as work, operating and safety regulations.

6
Personnel
This installation must be performed by authorized and qualified technical personnel
only. Before the installer begins with the assembly, he must be convinced of the
completeness of the scope of supply including the required accessories. The installer
may only use the prescribed network cables, please see the cabling in this manual.
There must be a security officer who is responsible for the security at diverse tasks
during the installation.
Attention
The installation should be performed only after you are thoroughly familiar with all of
the proper installation instructions and safety checks. This manual contains
fundamental information that should be observed in connection with installation,
start-up, operation and maintenance of the LED video display. If you do not follow
these instructions, it increases the risk of hazards and injury to the user. If you have
any questions during the installation, please contact Transtech LED Co.,Ltd.
Transtech LED Co.,Ltd shall not be liable for personal injury or damage to materials
caused by failure to observe this warning and safety information of this manual.
Furthermore Transtech LED Co.,Ltd cannot be held responsible for damage or injury,
caused by incorrect, inadequate or unsafe use, maintenance or installation of the
entire system. The liability as well as the effects of the same will become void if other
than genuine parts are used.
Before work on the system, the power must be disconnected, and the system must be
checked for absence of power and secured against further connection power.
All repairs of the system may only be carried out by Transtech LED Co.,Ltd respectively
by authorized and qualified technical personnel.
Certification
•CE
•FCC
•ETL
•TUV
•CCC

7
iPoster-2.5mm Specification:
Pixel pitch
2.5mm
LED Type
SMD (2020)
LED module size
210×280mm
Module Resolution(H×W)
84×112
LED driving method
1/28 dynamic scan
LED module layout(H×W)
9×2
Cabinet Resolution(H×W)
756×224
Cabinet area
1.09m²
Cabinet size
1902×572×35mm
Ingress Protection
Front IP40/Rear IP40
Power
AC 240/100±10%
Serviceability
Front service & Rear service
Brightness
2000cd/m²
Pixel density/cabinet
169,344
Contrast ratio
3,000:1
Viewing Angle(H/V)
160°/160°
Refresh rate
1920Hz
iPoster-1.9mm Specification:
Pixel pitch
1.9mm
LED Type
SMD (1010)
LED module size
210×280mm
Module Resolution(H×W)
110×146
LED driving method
1/28 dynamic scan
LED module layout(H×W)
9×2
Cabinet Resolution(H×W)
990×292
Cabinet area
1.09m²
Cabinet size
1902×572×35mm
Ingress Protection
Front IP40/Rear IP40
Power
AC 240/100±10%
Serviceability
Front service & Rear service
Brightness
1000cd/m²
Pixel density/cabinet
279,936
Contrast ratio
3,000:1
Viewing Angle(H/V)
160°/160°
Refresh rate
1920Hz
Specification:
Developed by Transtech team alone, iPoster series all new digital poster can be
controlled with fixed or portable Windows, IOS & Android devices. The content can be
refreshed and stored in built-in media player through WIFI or USB to achieve
asynchronous play.
iPoster Dimensions:

8
IPoster diagram
Note:
①Display area
②Main frame
③Hanging accessories installation area
④LOGO area
⑤Nitrogen spring
⑥Stuck
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
⑯
⑦Port area from top: LAN 1, LAN2, HDMI IN, HDMI OUT, AUDIO, LAN, USB1, USB 2, USB 3
⑧Supporter groove
⑨Power
⑩WIFI antenna
⑪HDMI port
⑫Cascade port
⑬Pedestal mounting screw hole
⑭USB port
⑮Power indicator,
signal indicator
⑯Input station

9
Note:
1. Acrylic panel 2. Module & lamp panel 3. Sides frame
4. Top frame 5. HUB board 6. Corner sealer
7. Pneumatic rod 8. Hand-holding 9. Track
10. Backboard 11. Power 12. Antenna
13. Back frame
1
2
3
4
5
6
7
8
9
10
11
12
13

10
Supporter standing
Open the folded supporter to stand
Installation
Pedestal standing
Put the cabinet onto base, fixed with screw
From①to⑤
Wall-mounted
①
②
③
④
⑤
Hanging installation

11
Front service
Serviceability:
Rear service
Suck out the module with maintenance tools
Maintenance tools
Module
Move the backboard screws

12
Accessories:
Screws
Connect the base and hanging or wall-mounted
accessories.
Size
M6*25
Quantity
4PCS/set
Material
SUS304
Wall-mounted accessories
Mount iposter on the wall.
Size
410*45.5*27.5mm
Color
Black
Material
SPCC
Power cord ( three core )
Connect the electric closet to screen;
3*2.5m2wires connects 8-10 cabinets.
Length
20m
Color
Black
Weight
3.5kg
Hanging accessories
Used for hanging iposter.
Size
140*50*3mm
Color
Black
Material
SPCC

13
Power cord
Connect the power between cabinets.
Length
0.5m
Color
Black
Weight
0.1kg
Base
Adopt stainless steel rope for rigging.
Material
A6063
Color
Black
Size
L571.8*W410mm
Power supply
Mount iposter on pedestal.
Voltage
5V
Color
Silver
Weight
0.66kg
Module
Spare module.
Color
Black
Size
210*280mm
Weight
0.42kg

14
Flat cable
Connect HUB board and module
Length
0.26m
Color
White
Weight
0.1kg
HDMI cable
Sync connect computer
Material
Copper wire
Color
Black
Weight
0.54kg
RJ45 cable
Connect Iposter with LAN or internet
Length
6-8m
Color
Blue
Weight
0.6kg

15
Flight case delivery: 4pcs per case
Wooden case delivery: 4pcs per case
Only suitable for long or short distance of fixed products: Wooden case + Pearl
cotton
Package:
Size:

16
Specification:
Wororking Voltage
100~240VAC
Rated power consumption
10W
Working temperature
-20°C ~ 85°C
Communication port
USB/RJ45
Controlled products
C Series
Data transmission port
1000M Ethemet
Material
SPCC
Dimension
315*205*44mm
Weight
1.5kg
Control system:
IPoster control system is composed by main controller (C6).
Main controller (C)
Note:
①Input Switch ②Indicator Light ③USB Port
④CONFIG ⑥Ethernet port ⑦HDMI input
⑧Audio output ⑨LAN interface ⑩USB
Hardware connection
Control & play without computer
C6 Configuration

17
Software installation
First download the installation package of LEDVISION software from Transtech's
official website www.trtled.com, and complete the installation according to the
diagrams shown below.
1. Run the software package, and select [ English ] for installer language. Click [ OK ]
to move on.
Note: Run LEDVISION version 4.20 or higher while using your C6.
2. After selecting a language, an installation wizard like below will appear. Click
[ Next ];
Then choose installation location, click [ Browse ] to change default target location,
then click [ Next ] after completing.
Choose components according to your own computer status, click [ Install ] to
complete.
After the installation is complete you are ready to use LEDVISION.

18
C6 Parameter Settings
Connection Settings
1. Before connecting your C6 to the computer, first click the control menu [ Control ]
→ [ Screen Control ], then select [ C-Series Play Box ] in Select Sending Device, then
set up [ LED Screen Window Management ].
Note: If you do not complete this step, LEDVISION may not function properly because
of a conflict between Net Card mode and C6 config interface.
2. Use standard USB A/B cable to connect C6 to computer when C6 is powered on,
one side to connect USB port, another side for C6 config port.
Click [ Publish Program to C Series Playboxes ] (as shown in the red box) to enter
program publish interface.

19
3. Left-click [ Direct USB ] and then right-click choose [ Refresh ], your C6 will show up
in program publishing window, select your device to set parameters and choose what
content to play.
Basic settings
●Ensure LED display is under normal configuration before setting on C6 parameters.
●When setting up C6 parameters, you can connect your C6 to your PC through a
standard USB A/B cable, and connect your C6 to your LED screen through network
cable.
1. Play Box Date and Time: Click [ Modify ] to set up date and time, or time zone as
well.
2. Alarm Settings: Set wake up and sleeping time, which works once checked.
3. Play box Time: Display the setting time.
Running Time: Calculated once C6 sender powered on.
Capacity/Remain: View memory utilization.
4. Power on, Sleep, Restart: To perform C6 sender box operation like power on, sleep
and restart once clicked.
5. Playing: Use the drop down menu to play programs.
Program Management: Check, delete and choose program, and much more.
This manual suits for next models
1
Table of contents