Triton Blue V700S-E User manual

PROFESSIONAL MOVING HEAD USER’S MANUAL
V700S-E
KEEP THIS MANUAL FOR FUTURE NEEDS

- 1- XM095 V1.2 NR
For your own safety, please read this user manual carefully before installing the device.
Every person involved with the installation, operation and maintenance of this device has to:
-be qualified
-follow carefully the instructions of this manual
INTRODUCTION:
Thank you for having chosen this professional moving head.
You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find: the fixture device, a power cable, an XLR
connection cable, a safety cable and this manual. Please check carefully that there is no damage
caused by transportation. Should there be any, consult your dealer and don’t install this device.
Features:
·Lamp: Philips MSR GOLD 700 SA/2 DE
·Control signal: Standard DMX-512, 24 channels (16 bit), 22 channels (8 bit)
·Stand alone operation with master/slave function, can be sound activated
·Pan/tilt movement: 8 bit and 16 bit resolution
For smooth and precise resolution
Pan: 540°/630° optional, Tilt: 265°movement
High speed of pan/tilt movement, speed of pan/tilt movement is adjustable
Scan position memory, auto reposition after unexpected movement
·CMY color mixture to get indefinite color effects
·Motorized color wheel with 8 dichroic filters and open, rainbow-effect with adjustable speed in
both directions
·Preset color and gobo-macros
·Both gobo rotation wheels with 6 rotating gobos plus open each, with different speed of gobo
shaking and rainbow effect, and gobo indexing
·The prisms can rotate in both directions in different speed, with prism indexing
·Macro effect for rotating gobos, rotating prism combinations
·Animation flame effect
·Separetly stepless frost filter to achieve variable soft beam
·Motorized focus
·Motorized linear zoom from 15° ~ 30°
·Linear dimmer in precise speed from 0~100%
·Stepless iris , 5%~100% linear change iris, pulse iris effect
·Stepless frost, 0%~100% linear change frost
·Preset variable iris, dimmer, shutter, frost pulse effects

- 2- XM095 V1.2 NR
·Strobe effect with 1-10 flashes per second or random strobe via shutter
·Friendly colored LCD display
·Battery buffered Control Board for operation time readouts etc
·Local and remote lamp on/off
·Preset program: 8 built in programs can be called up via DMX controller
·Editable program: Edit and save the program to inside EEPROM via the control board or external
controller, up to 250 scenes can be saved and then can be run in Stand Alone or sound activated.
·Number of scenes in Program Run can be changed individually
OVERVIEW
(1) Projector head
(2) Objective-lens
(3) Yoke
(4) Ventilation fan
(5) Base
(6) Control Board
(7) Carrying handle
(8) LCD-Display
(9) Mode/Esc-button
(10)Up-button
(11)Down-button
(12)Enter-button
(13)Microphone
(14)Update-socket
(15)Ventilation grille
(16)Housing screw
(17)Lamp system
(18)Fuse holder
(19)3-PIN DMX output socket
(20)3-PIN DMX input socket
(21)5-PIN DMX output socket
(22)5-PIN DMX input socket
(23)Power supply

- 3- XM095 V1.2 NR
SAFETY INSTRUCTIONS
This device has left the factory in perfect condition. In order to maintain this condition and to ensure
a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
If the device has been exposed to temperature changes due to environmental changes, do not switch
it on immediately. The arising condensation could damage the device. Leave the device switched off
until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be earthed.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case,
replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle
the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not
necessarily mean that the device is defective, it should decrease gradually.
Please be aware that damages caused by manual modifications to the device are not subject to
warranty. Keep away from children and non-professionals.
GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres, etc.
This fixture is only allowed to be operated with the max alternating current which stated in the
technical specifications in the last page of this manual, the device was designed for indoor use only.
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure

- 4- XM095 V1.2 NR
that the device will serve you for a long time without defects. Do not shake the device.
Avoid brute force when installing or operating the device.
The device shall only be used complete with its protective shield.
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. The minimum distance between light-output from the projector and the illuminated
surface must be more than 0.5 meter.
Always fix the fixture with an appropriate safety cable if you use the quick lock cam in hanging up
the fixture, please make sure the 4 quick lock fasteners turned in the quick lock holes correctly.
Operate the device only after having familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional
operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the product
may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to
short-circuit, burns, electric shock, lamp explosion, crash, etc.
INSTALLATION INSTRUCTIONS
a) Installing or replacing the lamp
Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very
high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a
cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the device
was designed for.
For the installation, you need one Philips MSR GOLD 700 SA/2 DE
Procedure:

- 5- XM095 V1.2 NR
1) Unscrew the 4 screws A, B,C and D on the bottom of the housing, holding the plate where the
lamp is underneath.
2) Gently pull the socket holder using the knob in the middle.
3) Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4) On the access plate there are 3 small screws marked 1, 2 and 3.which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get
the maximum light output as shown below.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes
after having turned off the lamp before you can turn it back on again.
b) Mounting the device
The installation of the effect has to be built and constructed in a way that it can hold 10 times the
weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate
safety cable.
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by
an expert before taking the device into operation for the first time.

- 6- XM095 V1.2 NR
These installations have to be approved by a skilled person once a year.
Cautions:
The effect should be installed outside areas where persons may reach it, walk by or be seated.
Overhead mounting requires extensive experience, including amongst others calculating working
load limits, installation material being used, and periodic safety inspection of all installation material
and the device. If you lack these qualifications, do not attempt the installation yourself. Improper
installation can result in bodily injury.
Before mounting make sure that the installation area can hold a minimum point load of 10 times the
device’s weight.
Connect the fixture to the mains with the power plug.
Installation method via clamp
Please refer to the picture below:

- 7- XM095 V1.2 NR
Screw one clamp each via a M12 screw and nut onto the Omega holders.
Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the
device. Tighten the quick-lock fasteners fully clockwise. Install the second Omega holder.
Pull the safety-rope through the holes on the bottom of the base and over the trussing system or a
safe fixation spot. Insert the end in the carabine and tighten the safety screw.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other
side to the male 3-pin XLR input of the moving head. You can chain multiple
Moving head together through serial linking. The cable needed should be two core, screened cable with
XLR input and output connectors. Please refer to the diagram below.
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in
preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply
an XLR plug with a 120 Ωresistor connected between pins 2 and 3,which is then plugged into the
output XLR socket of the last fixture in the chain. Please see illustrations below.

- 8- XM095 V1.2 NR
Starting address 49 Starting address 25 Starting address 1
Projector DMX starting address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct
fixture responds to the correct control signals. This digital starting address is the channel number
from which the fixture starts to “listen” to the digital control information sent out from the DMX
controller. The allocation of this starting address is achieved by setting the correct number on the
display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different address
for each fixture individually.
If you set the same address, all the units will start to “listen” to the same control signal from the same
channel number. In other words, changing the settings of one channel will affect all the fixtures
simultaneously.
If you set a different address, each unit will start to “listen” to the channel number you have set,
based on the quantity of control channels of the unit. That means changing the settings of one
channel will affect only the selected fixture.
In the case of the moving head, which is 24 channels fixture, you should set the starting address of
the first unit to 1, the second unit to 25(24 + 1), the third unit to 49 (25+ 24), and so on.
Control Board
The Control Board offers several features: you can simply set the starting address, switch on and off the lamp, run
the pre-programmed program or make a reset.
The main menu is accessed by pressing the Mode/esc-button until the display starts flashing. Browse through the
menu by pressing the Up-button or Down-button. Press the Enter-button in order to select the desired menu. You
can change the selection by pressing the Up-button or Down-button. Confirm every selection by pressing the

- 9- XM095 V1.2 NR
Enter-button. You can leave every mode by pressing the Mode/esc-button. The functions provided are described in
the following sections.
Default settings shaded
Function Mode
Set DMX Address
Value Display
Set To Slave
Auto Program
Music Control
A001~AXXX
PAN……
Slave1,Slave2,Slave3
Master / Alone
Master / Alone
DMX address setting
DMX value display
Slave setting
Auto program
Music control
Time Information
Current Time
Total Run Time
Total Lamp Time
Lamp Off Time
Clear Lamp Time
XXXX(Hours)
XXXX(Hours)
XXXX(Hours)
XXXX(Minute)
ON/OFF
Power on running time
Fixture running time
Lamp running time
Lamp off time
Clear lamp time
Temperature Info
Base Temperature
Head Temperature
XX ℃/℉
XXX℃/℉
Temperature on the display
board of the base
Temperature in the head
Information
Software Version
Ver1.2
Software version of each IC
Lamp Control
Lamp On or Off
Automatic La-On
Lamp On Via DMX
Lamp Off Via DMX
Lamp Off No DMX
Lamp On at Temp.
Lamp Off at Temp.
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF, 0FF~19M
20~79℃,45℃/68~174℉ 113℉
80~139℃,130℃ /176~282℉, 266℉
Lamp on/off
Lamp on/off when Power
on
Lamp on via DMX
Lamp off via DMX
Lamp off if no DMX
Lamp restart at temp.
Lamp off at temp.
Status Settings
Address via DMX
No DMX Status
Pan Reverse
Tilt Reverse
Fine Resolution
Pan Degree
Dimmer Speed
Feedback
Movement Speed
Mic Sensitivity
ON/OFF
Close/Hold/Auto/Music
ON/OFF
ON/OFF
ON/OFF
630/540
Slow/Quick
ON/OFF
Speed 1~ 4
0~99%
Add. via DMX
Auto run if no DMX
Pan Reverse movement
Tilt Reverse movement
Fine resolution switch
Pan Degree Select
Dimmer Speed Select
Movement Feedback switch
Movement Mode Select
Sensitivity of Mic.
Service Setting
Service Password
Fan Voltage
Gobo Speed
Password=XXX
High/Low
Quick/Slow
Service Code“=050”
Fan Voltage Select
Gobo Change Speed
Fans Control
Auto Fans Speed
High Fans Speed
Low Fans Speed
Fans Speed Mode Select
Display Setting
Shutoff Time
Display shutoff time
Temperature C/F
Celsius
Fahrenheit
Temperature switch
between ℃/℉
Personality
Initial Effect
PAN……
PAN =XXX
Initial effect position

- 10 - XM095 V1.2 NR
Reset Default
ON/OFF
Restore factory set.
Reset Function
Reset All
Reset Pan&Tilt
Reset Colors
Reset Gobos
Reset Shutter
Reset Others
Reset all motors
Reset Pan/Tilt
Reset color wheel
Reset gobos
Reset shutter and/or dimmer
Reset other motors
Test Channel
PAN ……
Test function
Manual Control
PAN
:
PAN =XXX
:
Fine adjustment of the lamp
Effect Adjust
Calibrate Values
--Password--
Color wheel
:
Password=XXX
Color wheel=XXX
:
Calbrate and adjust the
effects to standard/right
position Password“050”
User Mode
XXXXXX(Band)
User Mode A
User Mode B
User Mode C
User’s mode to change
channel numbers
Users Mode Set
Edit User Mode
PAN
:
PAN = CH01
:
Preset User modes
Select Programs
Auto Pro Part 1
Auto Pro Part 2
Auto Pro Part 3
Program 1 ~ 10 Program 1
Program 1 ~ 10 Program 2
Program 1 ~ 10 Program 3
Select programs to be run
Edit Program
Program 1
:
Program 10
Program Test
Step 01=SCxxx
Step 64=SCxxx
(“STEP XX”)
Testing program
Program in loop
Save and exit
Edit Scenes
Edit Scene 001
~ Edit Scene 250
Pan,Tilt,……
--Secne Time--
Input By Outside
Pan=xxx……
TIME=xx.xs
Save and automatically
return
manual scenes edit
Edit Program
Rec. Controller
XX~XX
Automat.scenes rec
Function Mode
DMX address setting
With this function, you can adjust the desired DMX-address via the Control Board.
• Select “Set DMX address” via the encoder.
• Press the encoder, adjust the DMX address by turning the encoder.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order return to the main menu.
Display the DMX 512 value of each channel
With this function you can display the DMX 512 value of each channel. The display automatically shows the channel
with a value changing.
Slave setting
With this function, you can define the device as slave.
Auto Program
With this function, you can run the internal program. You can select the desired program under “Select program”.
You can set the number of steps under “Edit program”. You can edit the individual scenes under “Edit scenes”.
With this function, you can run the individual scenes either automatically, i.e. with the adjusted Step-Time.

- 11 - XM095 V1.2 NR
Music control
With this function, you can run the internal program sound-controlled.
Information
Time information
Power on time
With this function, you can display the temporary running time of the device from the last power on. The display
shows “XXXX”, “XXXX” stands for the number of hours. The counter is resetted after turning the device off.
Total run time
With this function, you can display the running time of the device. The display shows “XXXX”, “XXXX” stands for
the number of hours.
Total lamp time
With this function, you can display the running time of the lamp. The display shows “XXXX”, “XXXX” stands for the
number of hours.
Lamp off time
With this function, you can display the temporary running time of the lamp from the last lamp on. The display
Shows “XXXX”, “XXXX” stands for the number of hours. The counter is resetted after turning the lamp off.
Clear lamp time
With this function you can clear the running time of the lamp. Please clear the lamp time every time you replace the
lamp.
• Select “Clear lamp time” by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Temp. Info.
Base Temp
With this function you can display the temperature in the projector base (near LCD-display) in Celsius.
Head Temp
With this function you can display the temperature on the display board of the base (near CMY-filter) in Celsius.
Software version
With this function, you can display the software version of the device.
• Select “Software version” by turning the encoder.
• Press the encoder, the display shows “V-X.X”, “X.X” stands for the version number, e.g. “V-1.0”, “V-2.6”.
• Turn the encoder in order to read the version of every individual IC.
• Press the Mode/Esc-button in order to return to the main menu.
LAMP CONTROL
When the real temperature around the lamp is higher than the preset value, the lamp will be shut down in 5
minutes automatically.
·When the LCD display shows “Off”, it means the lamp must be turned on again manually;
·When the LCD display shows “Hot”, it means the actual temperature around the lamp is still higher than the
preset value, so even the lamp can not be striked even the menu Lamp is turned to ON, as the lamp switch is
compelled to turned off.
·When the temperature unit after the temperature value come to lowercase letter “c” or “f”, it means menu
Lamp is turned to ON, but the lamp is not full dimming up.
·When the temperature unit after the temperature value come to capital letter “C” or “F”, it menu Lamp is
turned to ON, and the lamp is full intensity.

- 12 - XM095 V1.2 NR
Lamp on/off
With this function you can switch the lamp on or off via the Control Board.
• Select "Lamp on/off" by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Turn the encoder to select “ON” if you wish to strike the lamp or “OFF” in order to switch it off.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Remark: The menu Lamp On/Off is the software command only, the lamp can be striked successfully only when the
menu Lamp is set to ON and the actual temperature is lower than the limited value.
Lamp on/off when power on
With this function you can select if the lamp will be switched on when switching the power on. Select “ON” by
turning the encoder if you wish to enable this function or “OFF” if you don’t.
Lamp on via external controller
With this function you can select if you can switch the lamp on via an external controller (DMX-channel of internal
programs, value 64-79). Select “ON” by turning the encoder if you wish to enable this function or “OFF” if you
don’t.
Lamp off via external controller
With this function you can select if you can switch the lamp off via an external controller (DMX-channel of internal
programs, value 224-239). Select “ON” by turning the encoder if you wish to enable this function or “OFF” if you
don’t.
Lamp Off if no DMX
With this function you can select to switch off the lamp off automatically if there is no DMX signal). Select “OFF” by
turning the encoder if you wish to switch off the lamp automatically at once, Select “19M” by turning the encoder if
you wish to postpone to 19 minutes switch off the lamp automatically.
Lamp on at temp.
With this function you can set the inside temperature from which the projector will restrike the lamp after automatic
lamp shut off.
Lamp off at temp.
With this function you can set the inside temperature at which the projector will automatically switch the lamp off.
Turn the encoder to select the maximum inside temperature between 60° C and 159° C. Inside temperatures below 90°
C are not critical. 90° C and more should lead to the lamp being switched off. Please note that the outside temperature
should not exceed 45° C.
When the temperature around the lamp is higher than the preset value continuously up to 5 minutes, the
lamp will be shut off automatically.
If the lamp be shut off automatically due to over heat, it can not be striked again automatically, it must be
turned on again by manually.
PERSONALITY
Status setting
Address via DMX
With this function, you can adjust the desired DMX-address via an external controller.
• Select “Address via DMX” by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Turn the encoder to select “ON” if you wish to enable this function or “OFF” if you don’t.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
• On the controller, set the DMX-value of channel 1 to "7".
• Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address between 1 and 255.
When set to "8" you can adjust the starting address between 256 and 511.

- 13 - XM095 V1.2 NR
• Set the DMX-value of channel 3 to the desired starting address. If you want to set the starting address to 57, set
channel 1 to "7", channel 2 to "7" and channel 3 to "57". If you want to set the starting address to 420,set channel 1
to "7", channel 2 to "8" and channel 3 to "164" (256+164=420).
• Wait for approx. 20 seconds and the unit will carry out a reset. After that, the new starting address is set.
No DMX Status
With this function, when the drive is not DMX signal, it runs automatism, close, hold and music, the default is hold.
Pan Reverse
With this function you can reverse the Pan-movement.
Tilt Reverse
With this function you can reverse the Tilt-movement.
Fine resolution
With this function, you can fine resolution switch of pan movement or tilt movement.
Pan Degree
With this function, you can select pan degree for 630 or 540.
Dimmer speed
With this function, you can select dimmer speed for slow or quick.
Feedback
With this function, you can feedback switch of pan movement or tilt movement.
Movement Speed
With this function, you can select scan mode from 1 to 4.
Mic Sensitivity
With this function, the default is 70%, you can select the desired microphone sensitivity from 0 % to 99 %.
Service setting
Service Password
With this function, you can set the service password.
Fan Voltage
With this function, you can select fan voltage for high or low, the default is low
Attention: The model is not recommended when ambient temperature is higher than 15 Celsius degree.
Gobo speed
With this function, you can select GOBO speed for cquick or slow, the default is slow.
Fans Control
With this function, you can set the speed of the running fans. The selections have Auto、high and low.
Display settings
Shut off time
With this function you can shut off the LCD display after 2 to 59 minutes. Turn the encoder in order to select the
desired shut off time.
Temperature C/F
With this function, Display the temperature for Celsius or Fahrenheit.
Initial effect
With this function, Display initial effect position.

- 14 - XM095 V1.2 NR
Reset Default
With this function, you can select restore factory set for ON or OFF, the default is OFF.
Reset-functions
With this function you can reset the device via the Control Board. You can select the different reset functions by
turning the encoder.
Effect Adjust
Test function of each channel
With this function you can test each channel on its (correct) function.
Lamp adjustment
With this function, you can adjust the lamp more easily. All effects will be canceled, the shutter opens and the dimmer
intensity will be set to 100 %. With the individual functions, you can focus the light on a flat surface (wall) and erform
the fine lamp adjustment.
Calibrate values
With this function, you can calibrate and adjust the effect wheels to their correct positions. The password of calibrate
values is 050.
Users mode set
In this menu, user can select different channels list by different sequence:
For example, after the user enter this manual, if select Auto Program = CH 22, means in this User’s mode, the
“Dimmer” is in Channel 16.
User mode
With this function, you can create user defined channel orders.
Preset User mode
With this function, you can adjust the rest user defined channel order.
Edit program
Select program
With this function, you can select the program for the Program Run.
Edit program
With this function, you can edit the internal programs.
Edit scenes
With this function, you can edit the scenes of the internal programs.
Auto scenes rec.
The moving head features an integrated DMX-recorder by which you can transmit the programmed scenes from your
DMX-controller to the moving head. Adjust the desired scene numbers via the encoder (from –to). When you call up the
scenes at your controller, they will automatically be transmitted to the moving head.
Excursion:
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can start 3 different Slave units,
which run 3 different programs. The Master unit sends the 3 program parts in a continuous loop.

- 15 - XM095 V1.2 NR
The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to. If e.g. a
Slave unit is set to “Slave 1” in the menu “Set to Slave”, the Master unit sends “Auto Program Part 1” to the Slave unit.
If set to “Slave 2”, the Slave unit receives “Auto Program Part 2”.
To start a Auto Program please proceed as follows:
1. Slave-Setting
•Select“FunctionMode”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“Settoslave”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turntheencodertoselect“Slave1”,“Slave2”or“Slave3”.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
2. Automatic Program Run
•Select“FunctionMode”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“AutoProgram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turntheencodertoselect“Master”or“Alone”.Theselection "Alone" means Stand Alone-mode and "Master" that the
device is defined as master.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
3. Program selection for Auto Pro Part
•Select“Editprogram”byturning the encoder.
•PresstheEnterbuttontoconfirm.
•Select“Selectprograms”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turn the encoder to select “Auto Pro Part 1”, “Auto Pro Part 2” or “Auto Pro Part 3”, and thus select which Slave
program is to be sent. Selection “Part 1” means, that the Slave unit runs the same program as the master units.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
4. Program selection for Edit Program
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turntheencodertoselectthedesiredprogram.Withthisfunctionyoucaneditspecific scenes into a specific program.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
5. Automatic Scene Recording
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“Editscenes”byturningtheencoder.
•Turn the encoder to select the desired scene numbers. You can program a maximum number of 250 •Turn the
encoder to select the desired scene numbers. You can program a maximum number of 250 scenes.

- 16 - XM095 V1.2 NR
•Pressthe Enter button to confirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
Example:
Program 2 includes scenes: 10, 11, 12, 13
Program 4 includes scenes: 8, 9, 10
Program 6 includes scenes: 12, 13, 14, 15, 16
Auto Pro Part 1 is Program 2;
Auto Pro Part 2 is Program 3;
Auto Pro Part 3 is Program 6
The 3 Slave groups run the Auto Program in certain time segments, as shown in the following picture:
INSTRUCTIONS ON USE:
DMX channel´s functions and their values (24 DMX channels):
Channel 1 - Color Wheel:
0-13
Open / white
14-27
Light blue
28-41
Salmon pink
42-55
Blue
56-69
Green
70-83
Light yellow
84-97
Rose
98-111
Orange
112-127
Aqua
128-187
Forwards rainbow effect from fast to slow
188-193
No rotation
194-255
Backwards rainbow effect from slow to fast
Channel 2 - Cyan Color Wheel:

- 17 - XM095 V1.2 NR
0-255
Cyan (0-white, 255-100% Cyan)
Channel 3 - Magenta Color Wheel:
0-255
Magenta (0-white, 255-100% magenta)
Channel 4 - Yellow Color Wheel:
0-255
Yellow (0-white, 255-100% Yellow)
Channel 5 - PAN movement 8bit:
Channel 6 - TILT movement 8bit:
Channel 7 - Speed pan/tilt movement:
0-225
max to min speed
226-235
blackout by movement
236-245
blackout by all wheel changing
246-255
no function
Channel 8 - Rotating gobos, cont. rotation:
0-9
Open
10-19
Rot. gobo 1
20-29
Rot. gobo 2
30-39
Rot. gobo 3
40-49
Rot. gobo 4
50-59
Rot. gobo 5
60-69
Rot. gobo 6
70-89
Gobo 1 shake slow to fast
90-109
Gobo 2 shake slow to fast
110-129
Gobo 3 shake slow to fast
130-149
Gobo 4 shake slow to fast
150-169
Gobo 5 shake slow to fast
170-189
Gobo 6 shake slow to fast
190-255
Rot. gobo wheel cont. rotation slow to fast
Channel 9 - Rotating gobo index, rotating gobo rotation:
0-127
Gobo indexing
128-189
Forwards gobo rotation from fast to slow
190-193
No rotation
194-255
Backwards gobo rotation from slow to fast
Channel 10 - Rotating gobos, cont. rotation:

- 18 - XM095 V1.2 NR
0-9
Open
10-19
Rot. gobo 1
20-29
Rot. gobo 2
30-39
Rot. gobo 3
40-49
Rot. gobo 4
50-59
Rot. gobo 5
60-69
Rot. gobo 6
70-89
Gobo 1 shake slow to fast
90-109
Gobo 2 shake slow to fast
110-129
Gobo 3 shake slow to fast
130-149
Gobo 4 shake slow to fast
150-169
Gobo 5 shake slow to fast
170-189
Gobo 6 shake slow to fast
190-255
Rot. gobo wheel cont. rotation slow to fast
Channel 11 - Rotating gobo index, rotating gobo rotation :
0-127
Gobo indexing
128-189
Forwards gobo rotation from fast to slow
190-193
No rotation
194-255
Backwards gobo rotation from slow to fast
Channel 12- 3 facet rotating prism, Prism / Gobo macros:
0-3
open
4-63
Forwards rotation from fast to slow
64-67
No rotation
68-127
Backwards rotation from slow to fast
128-135
Macro 1
136-143
Macro 2
144-151
Macro 3
152-159
Macro 4
160-167
Macro 5
168-175
Macro 6
176-183
Macro 7
184-191
Macro 8
192-199
Macro 9
200-207
Macro 10
208-215
Macro 11
216-223
Macro 12
224-231
Macro 13
232-239
Macro 14
240-247
Macro 15

- 19 - XM095 V1.2 NR
248-255
Macro 16
Channel 13 – Focus:
0-255
Continuous adjustment from near to far
Channel 14 – Stepless Zoom
0-255
Zoom adjustment from small to big
Channel 15 - Shutter, strobe:
0-31
Shutter closed
32-63
No function (shutter open)
64-95
Strobe effect slow to fast
96-127
No function (shutter open)
128-159
Pulse-effect in sequences
160-191
No function (shutter open)
192-223
Random strobe effect slow to fast
224-255
No function (shutter open)
Channel 16- Dimmer (intensity):
0-255
Intensity 0 to 100%
Channel 17– Iris:
0-191
Max. diameter to Min.diameter
192-223
Pulse opening fast to slow
224-255
Pulse closing slow to fast
Channel 18- Animation wheel:
0-7
open
8-127
Forwards rotation from fast to slow
128-135
No rotation
136-255
Backwards rotation from slow to fast
Channel 19 –Frost:
0-191
Frost 0~100%
192-223
Pulse opening fast to slow
224-254
Pulse closing slow to fast
255
Max. Frost
Channel 20 - Speed Of CMY :
0-255
Speed Max ->Min
Table of contents
Other Triton Blue Light Fixture manuals
Popular Light Fixture manuals by other brands

Chauvet Professional
Chauvet Professional ROGUEOUTCAST1BEAMWASH Quick reference guide

Commercial Electric
Commercial Electric FP2X2/4WY/WH/HDT Use and care guide

Lightolier
Lightolier 8279EN specification

Harman
Harman Martin MAC Ultra Wash user guide

ADJ
ADJ ECO UV BAR 50 IR user manual

Vimar
Vimar Eikon 20394 manual

Lightolier
Lightolier H9S2GLR132 specification

Chroma
Chroma Inspire Mini user manual

vonado
vonado 42109 manual

Blizzard Lighting
Blizzard Lighting G60 user manual

Cooper Lighting Solutions
Cooper Lighting Solutions FW26PCI instruction manual

EXTOL LIGHT
EXTOL LIGHT 43219 Translation of the original user manual