TSI Instruments Dickey-John GAC 2700-AGRI User manual

Quick Start Guide
GAC
®
2700-AGRI
Grain Analysis Computer

GAC®2700-AGRI QSG 1
6015416 Rev A
Overview
Thank you for purchasing the DICKEY-john®GAC®2700-AGRI grain
moisture analyzer. The GAC®2700-AGRI quickly tests grain and
automatically calculates moisture content, test weight (bulk density),
and temperature of the sample using 149 MHz / UGMA technology.
Safety
Advisory identification and descriptions regarding operation of the
GAC®2700 can be found in the Operator’s Manual.
Declaration of Conformity
The GAC 2700 is in conformity with the provisions of many global
directives and regulations. Consult the Operator’s Manual for a
complete list.
This product creates an RF signal for measurement purposes and
meets the EMC requirements of the United States (FCC 47 CFR,
Part 18.109.(c), ISM Class A and ANSI C63.4:2014) and Canada
(ICES-001, CISPR11 Group 2, Class A).
The GAC 2700 product series is exempted from the Radio Equipment
Directive 2014/53/EU as the RF signal internal to the product is not used
for communications. The RF signal power is below the threshold limit to
be of concern for EMF Directive 2013/35/EU and therefore no MPE
calculation was determined necessary.
Liability
DICKEY-john®designed the GAC 2700 to measure oilseed and grain
moisture content. We rigorously test and calibrate each instrument
before it leaves the factory. Use of the instrument in the field, however,
is subject to environmental and operating conditions beyond our control.
DICKEY-john®disclaims all liability for damages resulting from
environmental and operating conditions beyond our control and for any
damages that might follow incorrect results due to those environmental
or operational conditions. IN NO EVENT SHALL DICKEY-john OR ANY
OF ITS AFFILIATES, OFFICERS, DIRECTORS, SUCCESSORS OR

2 GAC®2700-AGRI QSG
6015416 Rev A
ASSIGNS BE LIABLE FOR ANY DAMAGES WHATSOEVER,
INCLUDING SPECIAL, INDIRECT, CONSEQUENTIAL OR
INCIDENTAL DAMAGES OR DAMAGES FOR LOSS OF PROFITS,
REVENUE, USE, OR DATA AS A RESULT OF CLAIMS,
REGARDLESS OF THEORY BROUGHT, ARISING OUT OF OR
CONNECTED WITH ANY USE OR RELIANCE THE GAC®2700.
The operator is responsible for ensuring the results of the testing are as
accurate as possible by following approved maintenance procedures on
a regular basis, making sure the calibrations are up to date and the latest
version is being utilized, by cleaning the instrument and its sensors on a
regular and as-needed basis depending on the amount of dust, dirt, and
debris encountered in the instrument’s use, by monitoring performance
using daily check samples and by adhering to the check procedures set
forth in the manual. As with any kind of precision instrument, optimal
results depend in part on proper cleaning and maintenance.
For questions concerning these issues, refer to the product warranty, or
call your DICKEY-john®representative.
The complete Operator’s Manual is available on our website.
Unpacking
Carefully unpack the GAC®2700. Refer to the packing list below to
verify that all items are present. Contact DICKEY-john®if items are
missing or broken.
Retain the packaging for use when shipping the instrument; use of
other packaging for shipment may result in damage to the instrument.

GAC®2700-AGRI QSG 3
6015416 Rev A
Packing List
Qty
Description
1
Model GAC®2700-AGRI Grain Moisture Analyzer
1
Quick Start Guide
1
AC Power Cord
1
Allen Wrench (5/32”)
1
Cleaning Brush
1
Grain Drawer
Setting up the GAC®2700
Setting up the GAC®2700 requires the following procedures:
1. Open the carton and remove the Allen wrench from the upper
foam insert.
2. Remove the GAC 2700 from the plastic bag. Save the bag, the
packaging material, and the carton to use for future transport of
the instrument.
3. Ensure the installation location is level using the bubble level at
the top of the instrument; adjust the feet if necessary. Unit must
be kept level, making sure that there is sufficient clearance between
the GAC 2700 and the countertop so that the grain drawer is cleanly
inserted into the instrument.
4. Remove the grain drawer and place the unit gently on backside to
locate the shipping brackets on the left and right side walls.
IMPORTANT: Be careful when placing the unit on its backside to
avoid damage to the security switch.

4 GAC®2700-AGRI QSG
6015416 Rev A
5. Loosen and then remove the hex bolt from the
bracket on the left side wall.
6. Press down on the bracket to release.
7. Slide the bracket toward the bottom of the instrument.
8. Insert the hex bolt into the operating location hold
and tighten using the Allen wrench.
9. Perform the same procedure to the bracket on the right side wall.

GAC®2700-AGRI QSG 5
6015416 Rev A
10. Once both brackets are tightened to the operating location,
place unit upright.
Reverse the process to re-install the brackets for transportation.
This locks the weighing mechanism to prevent damage when moving.
Conducting Grain Analyses
The GAC®2700 is designed to provide minimal user interaction to run
grain moisture measurements. Upon power up, the GAC®2700-AGRI will
display the Home screen, which is the main screen to conduct grain
moisture analysis measurements. From the Home screen:
1. Press the Choose Product button to select the grain
or crop that will be analyzed.
2. Enter Sample ID (If desired).
3. Enter Customer ID (If desired).
4. Pour the sample into the Upper Hopper.
5. The START button will change to Green when there
is enough grain in the hopper to properly run a sample.
6. Press the START button.
Please consult the operator’s manual on the GAC®2700-AGRI
product page on the DICKEY-john®website for additional information
such as loading calibrations, data viewing and other features.

6 GAC®2700-AGRI QSG
6015416 Rev A
Maintenance
The GAC®2700 utilizes an RF frequency of 149 MHz to make
measurements within the machine. It is not a strong signal strength.
If potential interference is determined to originate from the GAC®2700
simple corrective steps can be taken; move the products further apart
from each other, re-orientate the products to each other.
IMPORTANT: It is highly recommended the unit be regularly
inspected and cleaned to ensure continued and consistent results.
For optimum performance, extensive cleaning should be
performed weekly or more often, as needed, based on surrounding
environmental conditions. Factors such as dust, temperature
extremes, grain dust, and external humidity vary from location
to location. If there are any questions about the cleanliness or
instrument performance, contact your local authorized
service center.
For customers that require a more extensive cleaning, contact and
schedule your instrument for cleaning with your dealer or
authorized service center.
Note: The following recommendations are provided as a guideline to
maintain a robust and quality operating instrument. It should not be
interpreted as an exhaustive maintenance program. Dust and debris may
periodically accumulate in areas not specified in this manual. The owner
is responsible for ensuring overall equipment cleanliness. If any
questions arise regarding the maintenance or performance of the
instrument, contact your dealer or local authorized service center.
EXTERNAL CLEANING
The LCD display may require periodic cleaning. Use a commercial
cleaner and cloth for glass lenses to remove dust.
Do not apply water, organic solvent
or chemicals, such as acid and alkali,
to the LCD display.
The GAC®2700 surface can be cleaned with any cleaner designed for
plastic and stainless steel surfaces.
Periodically use a cloth to wipe the grain hopper and the (2) upper grain
hopper sensors.

GAC®2700-AGRI QSG 7
6015416 Rev A
Figure 1 Grain Hopper Sensors
INTERNAL CLEANING
Performing continuous tests can result in material accumulation around
the critical internal components and adversely affect the measurement.
Two types of cleaning are recommended on an as needed basis:
• Daily clean
• Extensive clean (see Operator’s Manual for instructions)
DAILY CLEAN METHOD
A daily clean method allows cleaning the cell and door using an
automated process. During the cleaning sequence, the hopper door
automatically opens.
To start the cleaning process:
1. Select Device Information from the Main Menu.
2. Press .
A pop up message will appear with the words
“Cleaning Mode is Active”.
3. Remove the grain drawer.
4. Using the supplied brush, manually remove any loose or stuck grain
or dust from the measuring cell.
5. Press the CLOSE button to return instrument to normal operation.
Hands should be clear from
inside the instrument before
pressing the CLOSE button.
6. Insert grain drawer.
Press to return to the Home Screen.

8 GAC®2700-AGRI QSG
6015416 Rev A
Common Error Codes
ERROR
CODE
ERROR
1
Empty Cell Measurement Out of Spec
2
Empty Cell Weight Out of Spec
3
No Products Installed
4
Fill Motor Jammed
5
Invalid Grain Calibration File
6
Moisture Too High
7
Moisture Too Low
8
Instrument Low Temp Limit Exceeded
9
Grain High Temp Limit Exceeded
10
Grain Low Temp Limit Exceeded
11
Sample Weight Too High
12
Sample Weight Too Low
13
No Communication
14
Instrument High Temp Limit Exceeded
15
Unit to Grain Differential
16
Internal Power Supply Out of Spec
17
Unable to Predict Moisture
18
Pre-Analysis Timeout
19
Instrument Needs Updated
21
File I/O Error
22
Error RF Interference
23
Invalid GAC 2700 Model Number
24
No Locale
25
Could not Create Default Locale
50
Weight Measurement Device Error
51
Invalid Password
52
Date/Time Incorrect
53
Cold Sample Moisture Too High
55
Dump Motor Timeout
56
I/O Board Power Off Error
60
Network Unavailable
100
Unexpected Application Crash
Consult the Operator's Manual for more detailed information.

GAC®2700-AGRI QSG 9
6015416 Rev A
D I C K E Y - j o h n ®
W A R R A N T Y
Dealers have the responsibility of calling to the attention of their
customers the following warranty prior to acceptance of an order
from their customer for any DICKEY-john®product.
DICKEY-john®warrants to the original purchaser for use that, if any
part of the product proves to be defective in material or workmanship
within one year from date of original installation, and is returned to
DICKEY-john within 30 days after such defect is discovered,
DICKEY-john will (at our option) either replace or repair said part.
This warranty does not apply to damage resulting from misuse, neglect,
accident, or improper installation or maintenance; any expenses or
liability for repairs made by outside parties without DICKEY-john’s
written consent; damage to any associated equipment; or lost profits or
special damages. Said part will not be considered defective if it
substantially fulfills the performance expectations. THE FOREGOING
WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE,
AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED.
DICKEY-john neither assumes nor authorizes anyone to assume for it
any other obligation or liability in connection with said part and will not
be liable for consequential damages. Purchaser accepts these terms
and warranty limitations unless the product is returned within fifteen
days for full refund of purchase price.

DICKEY-john, the DICKEY-john
Logo, and GAC are a registered
trademarks of TSI Incorporated
in the United States and may be
protected under other country’s
trademark registrations.
6015416 Rev A
A DIVISION OF TSI
®
®5200 Dickey John Road
Auburn, IL 62615
www.dickey-john.com
+1 217-438-3371
+1 217-438-6012 fax
©2021 DICKEY-john
Quick Start Guide
GAC
®
2700-AGRI
Grain Analysis Computer
Other manuals for Dickey-John GAC 2700-AGRI
1
Table of contents