C
Launch the
terminal
program on
the UID.
Start the VT100 terminal program.
(Settings are VT100 emulation,
Data Bits = 8, Parity = none, Stop
Bit = 1, Flow Control = none, Baud
Rate = 1200 up to 115,200).
Press "Enter" twice to initiate
communications.
Enter the password at the Login prompt -default is "admin".
D
____________________________________________________________________________________________________________
04/21/05 Rev. A 940-00012-003
Select "CONFIG" at the top-level
menu.
.
If Remote Management is required,
select "IP/SNMP/DCC" in the
drop-down menu.
Set the IP
ddress and
Gateway fo
Telnet/SNMP
and DCC
Operation
Move the cursor to the IP Address,
Netmask, and Gateway locations
and enter the information. ^S to save.
E
From the Main Menu, select
"CONFIG", then "LINE".
.
Configure
the OMX84
module
options. Configure the settings as required
by using the cursor keys to select
the field and the space bar to toggle
each selection.
________________