manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tyco
  6. •
  7. Repeater
  8. •
  9. Tyco Visonic RP-600 PG2 User manual

Tyco Visonic RP-600 PG2 User manual

D-302415 RP-600 PG2 Installation Instructions 1
RP-600 PG2
Wireless Repeater for PowerG Systems
Installation Instructions
1. INTRODUCTION
The RP-600 PG2 is a range extender designed to relay digital data
between wireless PowerG control panel devices and a PowerG
control panel. Repeater links are required when the control panel is
beyond the range of at least some of the devices and is therefore
incapable of receiving transmissions directly (see Figure 3).
Figure 1. External View
2. INSTALLATION
2.1 Repeater's Location Selection
A. In a repeater setup, install the repeater where good
communication is assured with the target receiver and with the
transmitters deployed in the repeater's coverage area.
B. Mount the repeater as high as possible above the floor and well
away from metal chimneys, large metal cabinets, metal doors and
reinforced concrete walls, all of which may reduce the
communication range.
C. Make sure that the location you have selected is near an electrical
outlet.
1
2
3
(*)
4
6
5
B
C
AA
A
A. Mounting surface.
B. For back tamper screw.
C. AC to AC adaptor.
Attention! For Europe, the
transformer has to be CE
compliant and power
limited.
Note: The manufacturer of the
transformer is ORIENTAL
HERO, model no. OH-35048AT
rated 8.6VAC 0.33A. For UL
installations (UL) the plug-in
transformer must have
restraining means. For Canada
(CUL), it cannot have restraining
means.
Figure 2: Installation
2.2 Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES"option of the Installer Menu.
A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4
Enter the Installer menu and
select “02:ZONES/DEVICES”
Select "ADD NEW DEVICE" Option Enroll the device or enter the
device ID
Select the desired Zone Number




means scroll and select
ID No. 430
-
X
XXX
R
P04:Repeater
E
NTR ID:XXX
-
X
XXX
E
NROLL NOW or
M
ODIFY DEVICES
A
DD NEW DEVICES
0
2.ZONES/DEVICES
2 D-302415 RP-600 PG2 Installation Instructions
3. CONFIGURATION AND OPERATION
Service Messages
Five kinds of event codes are automatically included in a service
transmission in addition to the repeater’s:
AC fail Low Battery End of life Tamper Supervision.
Upon power failure, recharging stops and the backup battery takes over.
It is therefore correct to assume that without power input the battery is
gradually weakening and may be reported as “low”.
Power / battery restore is reported only in the following test report.
End of life is reported when battery power is depleted and device is
about to shut down.
Tamper restore is reported immediately upon occurrence.
If the tamper or power failure condition persists long enough,
respective alerts will be sent out again with each test report.
B
C
D
A
EF
A. Siren.
B. Motion detector.
C. Door or window open/close detector
D. Keyfob
E. RP-600 PG2 Repeater
F. Control Panel
Figure 3: Repeater Configuration
4. MAINTENANCE
CAUTION!
Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions.
Note: Battery replacement should be done by a service man.
B
C
D
A
E
F
H
G
A. Turn & push battery
B. Battery pack connector
C. Connect the wires to the terminal block
D. Self-Test button
E. Enroll button
F. AC connector terminal block
G. Battery cable
H. Battery
Figure 4 - Battery Pack Insertion
5. LOCAL DIAGNOSTICS TEST
Before testing, separate the base from the cover (see Fig. 2).
A. Press the self-test button once and release it:
The red LED and then the green LED will switch ON and then OFF in
turn to indicate that the repeater is now fully operational.
B. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength indication.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor"
signal strength is not acceptable. If you receive a "poor" signal from
the device, re-locate it and re-test until a "good" or "strong" signal
strength is received.
1. For detailed Diagnostics Test instructions refer to the control panel
Installer Guide.
2. For UL/CUL installations, the test result must be “Strong”.
D-302415 RP-600 PG2 Installation Instructions 3
6. COVER CLOSURE
See Figure 5.
1
2
Figure 5:
Cover Closure
7. NOTES AND WARNINGS
7.1 Product Limitations
Visonic Ltd. wireless systems are very reliable and are tested to high
standards. However, due to their low transmitting power and limited
range (required by FCC and other regulatory authorities), there are
some limitations to be considered:
A. Receivers may be blocked by radio signals occurring on or near
their operating frequencies, regardless of the code selected.
B. Wireless equipment should be tested regularly to determine whether
there are sources of interference and to protect against faults.
8 COMPLIANCE WITH STANDARDS
Compliance with Standards
Europe: EN 50131-1 Grade 2, Class II, EN 50130-5, EN 50131-6, EN 301489, EN 50130-4, EN 300 220
The RP-600 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the
Council of 9 March 1999 and EN50131-1 Grade 2 Class II.
Certified by the Dutch testing and certification body Telefication BV to the following standards :
EN 50131-3, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
Telefication BV has certified only the 868 MHz variant of this product.
USA: (FCC) CFR47 Part 15
Canada: RSS 210
UK: This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and
environmental class 2. DD243 and BS8243
The Power G peripheral devices have two- way communication functionality, providing additional benefits as
described in the technical brochure. This functionality has not been tested to comply with the respective
technical requirements and should therefore be considered outside the scope of the product’s certification.
EN 50131-1 Security Grade According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to and
including Security Grade 2.
EN 50131-1 Environmental
Class
Class II
FCC Compliance Statement
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and
television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following
measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the repeater should be located in a distance of at least 20 cm
from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other
antenna or transmitter.
Interference Prevention
This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that
may cause undesired operation.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
4 D-302415 RP-600 PG2 Installation Instructions
The technical documentation as required by the European Conformity Assessment procedure is kept at:
UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL.: +44(0)845 0755800 FAX: +44(0)845 0755801
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
APPENDIX: SPECIFICATIONS
Frequency Band (MHz) Europe and rest of world: 433-434, 868-869 USA: 912-919*
Note: For UL Listed product, enable thi
s
frequenc
y
band.
Communication Protocol PowerG
AC Power Supply: AC to AC adaptor 120 VAC, 60 Hz / 9 VAC, 0.35 A min. (U.S.A.)
230 VAC, 50 Hz / 9 VAC, 0.35 A min. (Europe)
Note: For UL Listed product, 120 VAC, 60 Hz.
Backup Batter
y
4.8-Volt 1300 mAh NiMH rechargeable (GP, GP130AAM4YMX)
Low Battery Threshold 4.8 V
Power Suppl
y
Type A
Time to charge 80 % (12 Hrs)
Low voltage alarm 4.8V
Nominal Current Drain (when using
external AC power) Frequency (MHz) 433 868 915
100 mA 100 mA 160 mA
Battery Backup Duration (with fully
charged 1300 mAh battery)
minimum 24 hours 5 minutes
LED indicator Green LED lights when AC power on
Operating Temperature 0°C to 49°C (32°F to 120°F).
Humidit
y
Average relative humidity of up to approximately 75% non-condensing. For 30 days per year the
relative humidity may vary between 85 % and 95 % non-condensing
Note: For UL Listed product, Relative Humidity is 93%.
Dimensions (LxWxD) 161x161x50mm (6-7/16 x 6-7/16 x 1-3/4 in)
Weight (including battery) 470g (16.5 oz.)
WARRANTY
Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original
purchaser only (the “Purchaser”) against defective workmanship and materials under normal
use of the Product for a period of twelve (12) months from the date of shipment by the
Manufacturer.
This Warranty is absolutely conditional upon the Product having been properly installed,
maintained and operated under conditions of normal use in accordance with the
Manufacturers recommended installation and operation instructions. Products which have
become defective for any other reason, according to the Manufacturers discretion, such as
improper installation, failure to follow recommended installation and operational instructions,
neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or
repair by anyone other than the manufacturer, are not covered by this Warranty.
The Manufacturer does not represent that this Product may not be compromised and/or
circumvented or that the Product will prevent any death and/or personal injury and/or damage
to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all
cases provide adequate warning or protection. The Product, properly installed and
maintained, only reduces the risk of such events without warning and it is not a guarantee or
insurance that such events will not occur.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, OBLIGATIONS OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS
OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER
BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR
BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS
AFORESAID.
THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR
EXPENSE, INCLUDING LOSS OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY
OR INDIRECTLY ARISING FROM PURCHASER’S USE OR INABILITY TO USE THE
PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY
OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGE.
THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL
AND/OR BODILY INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS
WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE,
BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY
(IF ANY) SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE
PRODUCT, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.
When accepting the delivery of the Product, the Purchaser agrees to the said conditions of
sale and warranty and he recognizes having been informed of.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages, so these limitations may not apply under certain circumstances.
The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or
malfunctioning of any telecommunication or electronic equipment or any programs.
The Manufacturers obligations under this Warranty are limited solely to repair and/or replace
at the Manufacturer’s discretion any Product or part thereof that may prove defective. Any
repair and/or replacement shall not extend the original Warranty period. The Manufacturer
shall not be responsible for dismantling and/or reinstallation costs. To exercise this Warranty
the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and
insurance costs are the responsibility of the Purchaser and are not included in this Warranty.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only. All products, accessories or
attachments of others used in conjunction with the Product, including batteries, shall be
covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products. This
Warranty is exclusive to the original Purchaser and is not assignable.
This Warranty is in addition to and does not affect your legal rights. Any provision in this
warranty which is contrary to the Law in the state or country were the Product is supplied shall
not apply.
Warning: The user must follow the Manufacturer’s installation and operational instructions
including testing the Product and its whole system at least once a week and to take all
necessary precautions for his/her safety and the protection of his/her property.
1/08
EMAIL: [email protected]
INTERNET: www.visonic.com
VISONIC LTD. 2013 D-302415 RP-600 PG2 (Rev 3, 1/13)

Other Tyco Repeater manuals

Tyco DSC WS8920 User manual

Tyco

Tyco DSC WS8920 User manual

Tyco PGx312 series User manual

Tyco

Tyco PGx312 series User manual

Popular Repeater manuals by other brands

ITI Quick Bridge 60-615 installation instructions

ITI

ITI Quick Bridge 60-615 installation instructions

pass & seymour radioMiro instructions

pass & seymour

pass & seymour radioMiro instructions

Hama N300 operating instructions

Hama

Hama N300 operating instructions

Cudy RE300 installation guide

Cudy

Cudy RE300 installation guide

Kenwood TKR-7400S Brochure & specs

Kenwood

Kenwood TKR-7400S Brochure & specs

TP-Link RE350K user guide

TP-Link

TP-Link RE350K user guide

Pima WRP installation instructions

Pima

Pima WRP installation instructions

Argent Cables IR-KIT-X2 instruction manual

Argent Cables

Argent Cables IR-KIT-X2 instruction manual

Channel Vision IR-1204 user manual

Channel Vision

Channel Vision IR-1204 user manual

Omron CRT1 - 10-2009 Operation manual

Omron

Omron CRT1 - 10-2009 Operation manual

Hobo RXW series manual

Hobo

Hobo RXW series manual

Grandstream Networks DP760 user manual

Grandstream Networks

Grandstream Networks DP760 user manual

Zennio Linecoupler ZN1SY-LCTP user manual

Zennio

Zennio Linecoupler ZN1SY-LCTP user manual

Kramer PT-101HDCP user manual

Kramer

Kramer PT-101HDCP user manual

BWI Eagle AIR-EAGLE XLT 441-4500-DC Product information bulletin

BWI Eagle

BWI Eagle AIR-EAGLE XLT 441-4500-DC Product information bulletin

Alutech AR-S Operation manual

Alutech

Alutech AR-S Operation manual

Futurecom PDR8000 manual

Futurecom

Futurecom PDR8000 manual

Cellvine BDA-TDD-25-16-19-AA General Installation & Operation Guide

Cellvine

Cellvine BDA-TDD-25-16-19-AA General Installation & Operation Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.