UI SP-556 series User manual

【Operation Manual】
Digital speed meter
MODEL: SP-556 Series
Series
name
Output Input
Sensor
Power
Power
type
Color
Cover
Function
SP-556
Preset output two point
(NPN open collector output)
No
code
7segment red LED
GL
7segment green LED
P2
Two point Photo MOS relay output
AV3
Analog voltage output (DC 1-5V)
AV4
Analog voltage output (DC 0-5V)
AV5
Analog voltage output (DC 0-10V)
AI
Analog current output (DC 4-20mA)
B *1
BCD output
BI *1
BCD input
No
code
NPN Open Collector pulse input
F
Voltage pulse input
V3
Tacho-generator signal input AC 0.8V-80V(P-P)
N
Sine wave signal input AC 0.05V-20V(P-P)
L1
Line receiver 1CH (A・A) input
F2
Current modulation pulse input(A-input)
F2W
Current modulation pulse input(A-input, B-input)
HI
High-speed input (0.01Hz~120kHz)
No
code
DC12V 100mA
S24
DC24V 60mA
No
code
Power source:AC 100V-240V
DC *2
Power source:DC 12V-24V
DM *3
Unredeemable type
No
code
Gray
K Black
No
code
not attached
C Terminal stand cover
*1 “B” Option and “BI” Option cannot be selected together.
*2 Optional “DC” is outside CE marking.
*3
The meter is an subject of CE Marking. But box-type (DM) is off the subject of CE Marking.
【 8th 8 Sep. 2015 】
@SP-556CE(8)-E

Precautions
Please read this Operation Manual including the following precautions carefully to ensure safe
use of your meter.
! <Caution> Do not use this product for applications outside of the product specifications.
! <Caution> User-conducted alterations and modifications of the unit should not be
performed as they may impair functioning or cause failure and accidents.
! <Caution> Direct sunshine is avoided, and ratings are used in the place of each Onshime
and the place where the be dewy occurs easily. Do not do.
! <Caution> Do not use it in the place with the combustible gas and the ignition thing.
! <Caution> Do not subject the unit to strong vibrations or shocks.
! <Caution> Do not allow metallic debris, dust, or moisture to penetrate the unit.
! <Caution> For safety, professional wiring electrical work, such as electrical wiring is please
go. Please shut off the power when electrical wiring.
! <Caution>
Please use one which matches rating for the AC/DC power supply supplied to a meter.
! <Caution> After the power supply, it operates at once because there is no power on/off
switch for the unit.
! <Caution> Do not touch the terminal while operating. It gets an electric shock.
! <Caution> Wipe it with a dry cloth when you clean the meter.
! <Caution> Devices to be connected to each terminal of the terminal block,
use the one that is properly isolated from hazardous live parts.
! <Caution> Since there is no power switch in this machine, it will be in an operating state
immediately after power supply impression. Equipment to be incorporated in
the side of our customers,please be prepared to supply the switch and
circuit breaker which adapted to IEC/EN60947-1 or IEC/EN60947-3
standard in the position that you can operate immediately in emergency.
Moreover, please specify that they are interrupting devices.
! <Caution> This machine is designed to be used with the panel mounted.
When used in a state other than that, there is a possibility that the
protective device is provided with is impaired.
! <Caution> Use the temperature rating 70 ℃ or more power cord.
Product Description
This product is a panel mount meter that can measure Speed/Rotation/Flow rate/Ratio
/Shot speed/Street time/Cycle timer/Stopwatch.
The preset output function of two points has been equipped normally. The preset output
two points and the analogue signal and the BCD signal outputs can be added in the option.
The option to which the preset setting value can be input from the outside by the BCD signal
is prepared.
With the panel mounted, the front has been protected by grade IP66, dust and water
resistant products.

Contents
1.About confirmation of an attachment. and a guaranteed period
・・・・・1
2.Specifications
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・2-4
3.Mounting meter
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・5
4.Names and functions of components on front
・・・・・・・・・・・・・・6-7
5.Connecting terminal boards
・・・・・・・・・・・・・・・・・・・・・・・・8-9
6.Construction of input circuit
・・・・・・・・・・・・・・・・・・・・・・・・10
7.D ip switch
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・11
8.The setting menu
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・12-13
9.Initial setting values and initialization
・・・・・・・・・・・・・・・・・・・・14
10.Content and setting the each mode
・・・・・・・・・・・・・・・・・・・・15-33
Operating method (the mode setting)
・・・・・・・・・・・・・・・・・・・・・・・・・・・・15
Content of the each mode and set value
・・・・・・・・・・・・・・・・・・・・・・・・・16
「Mode No.0」
Measuring types, Measurement unit, Display decimal point
・・・・・・16-20
「Mode No.1」
A-input:A-input:Setting of scaling data
・・・・・・・・・・・・・・・・・21-22
「Mode No.2」
A-input:Exp.value, moving average, auto-zero time
・・・・・・・・・・23-24
「Mode No.3」
B-input:B-input:Setting of scaling data
・・・・・・・・・・・・・・・・・24
「Mode No.4」
B-input:Exp.value, moving average, auto-zero time
・・・・・・・・・・24
「Mode No.5」
Deceleration ratio/Oven-length (tact pitch) setting
・・・・
・・・・・・25
「Mode No.6」
Sampling time
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・26
「Mode No.7」
Hold-function setting, display blank, lowest digit display
・・・・・・・・27
「Mode No.8」
OUT1:Preset output (open collector output)
・・・・・・・・・・・・・・28
「Mode No.9」
OUT2:Preset output (open collector output)
・・・・・・・・・・・・・・29
「Mode No.A」
OUT3:Preset output (photo MOS relay output, Option:P2)
・・・・・・・
29
「Mode No.b」
OUT4:Preset output (photo MOS relay output, Option:P2)
・・・・・・・
30
「Mode No.C」
Analog output:Setting of measurement choice and the output digit
・・・・31
「Mode No.d」Analog output:Setting of maximum output indication(Option:AV3-5/AI)
・・・・・32
「Mode No.E」
BCD output setting
(Option:B)
・・・・・・・・・・・・・・・・・・・・・・・・・・32
「Mode No.F」
BCD input setting
(Option:BI)
・・・・・・・・・・・・・・・・・・・・・・・・・・・33
11.Mode protect function
・・・・・・・・・・・・・・・・・・・・・・・・・・・・34
12.Teaching function
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・35
13.Calling up and modifying the preset value setting
・・・・・・・・・・・・・・・36
14.Adjusting the analog output(Option:AV3-5/AI)
・・・・・・・・・・・・・・37
15.Adjusting the tacho-generator signal, sine wave signal input (Option:V,N)
・・38
16.Connection diagram for BCD output ( Option:B )
・・・・・・・・・・・・・・39
17.Connection diagram for BCD input ( Option:BI )
・・・・・・・・・・・・・・・40
18.External dimensions
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・41
19.Unredeemable type (Option:DM)
・・・・・・・・・・・・・・・・・・・・・・・42
20.About a noise countermeasure
・・・・・・・・・・・・・・・・・・・・・・・・43
21.Troubleshooting
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・44-45

- 1 -
1.About confirmation of an attachment and a guaranteed period
About confirmation of an attachment.
When you received as a product, please confirm whether it includes the following.
(1)SP-556(The chosen specification) ・・・・・・・・・・・・・・・1
(2)SP-556 Operation manual (This book)・・・・・・・・・・・・・1
(3)Unit label(Attachment)
・・・・・・・・・・・・・・・・・・・・・・・1
If there are the mistaking parts and the missing parts, please inform a dealer or us.
(There is a case that you don't attach by convenience.)
About a guaranteed period and a guaranteed area.
1.Guaranteed period
The period a product guarantees is 4 years from a delivered day.
2.Guaranteed area
If we trouble by responsibility in whole guaranteed period, it's repaired without
charge at our factory. But if a product conflicted in the following matter,
it isn't a guarantee target. Please understand.
① Case of outside of the product specifications.
② Case of User-conducted alterations and modifications of the unit.
③ Case of besides our responsibility.
④ Case of safekeeping and transportation beyond the product specification condition.
⑤ Case due to natural disaster and accident.

- 2 -
2.Specifications
(1) Standard specifications
Item Specifications
Rate
Meter
Measuring types Ratemeter (speed, rotation,flow rate,),
differential rate
,
ratio, shot speed, passing time, cycletimer, stop watch
Measuring system Periodic sampling operation
Scaling (Pulse rate)
1×10
-9
– 9999 (selectable)
Measurement
accuracy
< speed, rotation, flow rate, differential rate, ratio, passing time >
±0.05% rdg.±1digit
( at Sampling time for 0.5 second or more , per one input )
< shot speed >
±0.1% rdg. ±1digit
( in one measurement less than 100Hz )
< cycletimer, stop watch >
±0.05% rdg.±2mS ±1digit ( in one measurement )
Display
7 segment red color LED (character height:14mm) ×5 digits
Option input (GL)
7 segment green color LED (character height:14mm) ×5 digits
Indication area -9999~99999
(When indication overflowed, 99999 or -9999 blinking)
Decimal point Displays 1 - 3 decimal points. (selectable)
Time unit Per hour , per minute , per second (selectable)
Sampling time Rate reading averaged by 0.1-99.9sec (selectable)
Display mode Blank, Real, least significant digit fixed at 0, or 0/5
(selectable)
Moving average Averaged by 1 – 19 input pulses. (selectable)
Auto zero time The time(0.5-120 sec. selectable), following input stop,
at which the reading returns to zero.
Measurement reset
Front reset key and Reset input of terminal stand
Sensor
Input
Sensor input signal
NPN open collector pulse input (10mA min.) or ground contact
Option input (F)
Voltage pulse input (LOW:2.0V or lower, HI:3.8V-30V)
Option input (V3)
Tacho-generator signal input (AC 0.8V-80Vp-p 3kHz MAX)
Option input (N)
Sine wave signal input (AC 50mV-20Vp-p 3kHz MAX)
Option input (F2,F2W)
Current modulation pulse input
(LOW:8mA or lower, HI:15-20mA)
Option input (L1) Line receiver 1CH ( A・A ) input
Sensor input
response
0.01Hz-10kHz (duty 50%)
(Low:0.01-50Hz, Mid:0.01Hz-1kHz, Hi:0.01Hz-10kHz switch shifting)
Sensor input
response (HI)
0.01Hz-120kHz (duty 50%)
Open collector input / voltage pulse / line receiver input only
Sensor power
DC 12V (±10%) 100mA MAX
Sensor power (S24)
DC 24V (±10%) 60mA MAX
Auxiliary
Input
Reset input 50ms or more is turned on. and, reset
(terminal board:open collector input)
Hold selection input
(Reverse-rotation)
Hold / peak hold / bottom hold / Reverse-rotation signal
(Mode No.7)
(terminal board:open collector input)

- 3 -
Others
Mode protect Protection of the mode setting
Data backup
Each mode setting value is memorized by FRAM(The memory number
of times is within 100,000 times, About 10 year safekeeping.)
Power supply AC 100-240V (-15% / +10%) 120mA max
50/60Hz approx 20VA
Power supply (DC)
DC 12-24V ±10%
Operating temperature
/ humidity conditions
0-50℃ / 30-80% RH (non-condensing)
Weight / Dimensions
approx 400g / W96 × H48 × D130 (mm)
Case-material
ABS color (Terminal board PBT Black color)
Case-Color
Gray
Case-Color (K)
Black
Protection class
IP66 (Front only)
Installation
environment
The indoor use. Altitude 2,000m max
Overvoltage category Ⅱ , Pollution degree 2
(2) Output specifications
《NPN Open collector Preset output:standard equipment》
Output terminal Output terminals No.9-6(OUT1),10-6(OUT2) (COM common)
Output condition
Judgment output is compared with the indication value by pre-set value.
Output system NPN Open collector output 2 stages (DC 30V 50mA max)
Output indication During preset output, the OUT1 and OUT2 LEDs are activated.
Output reset Front reset key and Reset input of terminal stand
(50ms or more is turned on)
Time to prohibit judgment
The preset output function is disabled for the specified time
《Photo MOS relay Preset output:P2 option》
Output terminal Output terminals No.15-16(OUT3),17-18(OUT4)
Output condition
Judgment output is compared with the indication value by pre-set value.
Output system Photo MOS relay output 2 stages
(“
a” point of contact)
(Voltage:AC140V DC30V , Load current:0.12A max)
Output indication During preset output, the OUT3 and OUT4 LEDs are activated.
Output reset Front reset key and Reset input of terminal stand
(50ms or more is turned on)
Time to prohibit judgment
The preset output function is disabled for the specified time

- 4 -
《Analog output:AV3-AV5 / AI option》
Output terminal Output terminals No.19-20 (Analog output)
Voltage output (AV)
0-5V, 1-5V, 0-10V load impedance 2kΩ or more
Current output (AI)
DC 4 - 20mA load impedance 500Ω or less
Output accuracy
Within ±0.3%F.S. for indicated value (at 23℃)
The temperature
characteristic
±100 ppm/℃
Output response
Approx 50ms (But, an output change is time until the 90% arrival.)
Output resolution
12-bit D/A conversion operation
AI
DC4-20mA
: 4000 resolution
AV3 DC1-5V : 4000 resolution
AV4 DC0-5V : 4000 resolution
AV5 DC0-10V
: 4000 resolution
※Maximum output area:It's possible to output to 102.3%
to the maximum of each output.
※
An analog output is outputting calculation to the indication value
shown to 7segment LED. Therefore the resolution sometimes falls
from 4000 by setting of Mode No.
”
C
”
and
”
d
”
.
《BCD output:B option》
Output terminal Output from BCD optional connector
Output type All digits parallel open collector output
Output timing Synchronized with at the sampling time (Mode No. “6”)
Output operation The output is in a state (H), and an emitter and the collector do
conduction. (positive)
TI
(take-up inhibition) “H” level (about 25ms width) at time renewing the data
Output logic Positive / negative logic change is possible (Data TI output each)
Output rating DC 30V 10mA (max)
《BCD input:BI option》
Input terminal Input from BCD optional connector
Input type All digits parallel open collector input
Input timing Operation period unit
Input operation Input signal and GND short-circuit or open
Latch signal Latch signal prohibits the uptake of data at the time of ON
Input logic Positive / negative logic change is possible (Data TI output each)
Input rating Short current of each input:approx 3mA

- 5 -
3.Mounting meter
How to mount meter
1. Cut the panel to insert the meter from the front.
Panel cutout dimensions
Fig.1
Unit (mm)
2. Please push the Fitting for fixing the body.
Into a right and left both sides of the meter.
Fig.2
Slide in the rear side (terminal stand side)
as for the fitting for fixing the body.
It turns a screw by the driver.
The meter is fixed (right and left both sides)
Fig.3
! <Caution>
1. Please install it horizontally.
2. Fit the body on to a panel 1.0-4.0 mm in thickness.
3. Please do not tighten the screw of the mounting bracket too much.
(The case might be damaged when tightening too much.)
4. When you mount the machine, please provide a space of at least 20mm
from the wall in the direction of up and down, right and left and rear
(terminal stand side).
92 -0
+0.8
Fitting for fixing the body
Fitting for fixing the body
Driver
Packing
Meter Installation board

- 6 -
4.Names and functions of components on front
Fig.4
①Display unit ( A to E )
Measurement state:Measurements are displayed.
Setting state:When the mode is set, it displays it as follows.
A
・
・・・・Mode No. is displayed.
B - E・・・Mode items such as the converted value, etc are displayed.
:When the preset output is set, the value input now is displayed.
:When the teaching function is set, the value set now is displayed.
②-⑤Preset output lamp
Measurement state:When the preset output is output, it lights.
Setting state:When the preset output is set, OUT1-4 that is setting it now is displayed.
⑥, ⑦Each input display lamp
Measurement state:
When Mode No.0 BC is
“
02
”
-
“
07
”
(ratio measurement), the measurement
display switch of Ratio measurement (A and B input lamp is turned off)/
A input measurement (A input lamp light.)/
B input measurement
(B input lamplight.)can be done.
Setting state:The set A input measurement
or
B input measurement lamp lights when
the teaching function is set.
⑧Hold display lamp
Hold input function
is set in Mode No.7 B. (Refet to P.27)
When the hold input of the terminal stand is turned on, and the holding operation is done,
it lights.
Indicate
Output 1 2 3
A HDB
4Mode ENT
RST
Display
A B
1
C D E
3
4
5
2
7
6
8

- 7 -
⑨ Mode key
Measurement state:It enters the mode setting state if + are pushed
for 2 sec. or more.
:It enters the preset output setting state if only is pushed
for 2 sec.or more.
Setting state:When the mode is set, the mode number is raised.
When the preset output is set, OUT1-4 is changed.
⑩ Up key
Setting state:When each setting it, the numerical value of a set digit is raised.
⑪ Down key
Measurement state:When this key is pushed for 2 sec. or more, the state of the mode
protecting is displayed. (Refet to P.34 Mode protect function)
Setting state:When each setting it, the numerical value of a set digit is lowered.
⑫ Shift key
Measurement state:When Mode No.0 BC is “00”(A input measurement) or
“01”(B input measurement),
The teaching function works.
(Refet to P.35 Teaching function)
Setting state:When each setting it, a set digit is shifted to a right digit.
⑬ Enter key
Measurement state:
When Mode No.0 BC is
“
02
”
-
“
07
”
(ratio measurement), the measurement
display switch of Ratio measurement / A input measurement /
B input measurement
can be done.
Setting state:When the mode is set, and the preset output is set, a set value is registered,
and it returns it to Measurement state.
⑭ Reset key
Measurement state:When this key is pushed for 2 seconds or more, the output of
measurement reset (Indicated value 0) and preset output OFF.
Setting state:When the mode is set, and the preset output is set, a set value is not
registered, and it returns it to Measurement state.
Mode
Mode
ENT
RST
Mode

- 8 -
5.Connecting terminal boards
Fig.5
! <Caution>
1)For safety, professional wiring electrical work, such as electrical wiring is please go.
Please shut off the power when electrical wiring.
2)Power supply confirmation
・Confirm the specification of the AC power supply type and the DC power supply type well.
・DC power supply type notes the polarity.
3)Wire correctly after often confirming the terminal stand label.
4)The wiring technique is different depending on the kind of the sensor.
Wire correctly referring to the connection diagram ( P.9 ) and the manual of the sensor.
The sensor and the meter might break down when connecting it by mistake.
5)Do not use the sensor power supply for the usages other than the sensor.
6)Tighten the screw of the terminal stand surely.
7)Do not touch the terminals while power is being supplied. There is a risk of electrical shock.
2 3 4 5 6 7 8 91 10
11 12 13 14 15 16 17 18 19 20
GNDN.C. RST GND A.IN B.IN
F.G. N.C.
AC100-240V
DC12-24V
-+
AV / AI
-+
Preset output
Pulse sensor A
Line driver
Tacho-generator
7 8
Pulse sensor B
5 6
BCD output (option)
Option:L1
Sine wave
Other power source
87
6
6
Option:V3, N

- 9 -
Tacho-generator (V)
Sine wave(N3)
Sensor-A
7 8 9
AIN
A input Line driver
B input
A-Sensor Sensor
B-Sensor
BIN AIN
7
BIN
865
GND
Sensor-B
5 8
BINGND
6
AIN
7 6
GND
5
AIN
7
BIN
8
+12V
6
GND
5
AIN
7
BIN
8
+12V GND
6
+12V
5
AIN
7 8
- OUT+
-
AIN+12V
5
GND
6
Sensor
+
87
A. Tacho-generator / Sine wave B. Pulse output 2-wire type sensor
Fig.6 Fig.7
C. Ground contact output sensor D. Line driver encoder
Fig.8 Fig.9
E. Pulse output 3-wire type sensor F. Current pulse input (3-wire pulse sensor)
Fig.10
Fig.11
G. Current pulse input (2-wire pulse sensor)
Fig.12
NOTE
・When mis-counting by the chattering of the having point of contact input,
(Relay etc.) Connect the electrolytic capacitor with terminal stand
6-7 (A input) and 6-8 (B input) according to the frequency.
・When mis-counting because of the noise etc, Connect the film capacitor with the
same terminal according to the width of the input frequency and the noise.

- 10 -
6.Construction of input circuit
① NPN open collector pulse input
Fig.13
② Voltage pulse input ③ Reset・Hold input
Fig.14 Fig.15
④
Tacho-generator signal input/Sine wave signal input
⑤ Line driver input
Fig.16 Fig.17
100K
+12V
Sensor power
or
3,6
7,8
5
+12V 2.2K
SW5,6
470
30V
1.5K
3V
1.5K
3V30V
100K
470
SW5,6
2.2K
+12V
+12V
5
7,8
3,6
又は
+12V
6 , 3
4 , 2
2.2K
104
1K
7
+
-
26LS32
102
8
103
250V104K
1K 20KB OP-07
+
-
7
8

- 11 -
7.Dip switch
Sensor input, and relationship of the sensor input response is shown in Table1.
Table.1
B.IN A.IN B.IN
A.IN
OFF⇔ ON
1 2 3 4 5 6
Input frequency 0.01Hz - 50Hz LOW
ON
OFF
OFF
ON
Input frequency 0.01Hz - 1kHz MID
OFF
ON
ON
OFF
Input frequency 0.01Hz - 10kHz HI
OFF
OFF
OFF
OFF
Input frequency 0.01Hz - 120kHz ※
OFF
OFF
OFF
OFF
NPN open collector input ON
ON
Voltage pulse input OFF
OFF
※ Option(HI) type
When a sensor optional input is not specified, sensor input is “NPN open collector”, and
Sensor input response is “HI”.
Fig.18
1

- 12 -
8.The setting menu
≪Test Mode≫
Power supply OFF
Test mode
Turn power supply on with
ENT
RST
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
ENT
RST
ENT RST
being pressed.

- 13 -
≪Setting menu≫
Turn power supply on.
Power supply OFF
Measurement
0. 0 2 1
1. 1 0 A input:Setting of scaling data
0 0
3.
2.
01
3
00
0 2
0
7.
6.
5.
4.
0
3
Sampling time
0 0
2. 0
2
E.
0 0
b.
C.
d. 1 0
1
A.
9.
8.
00
0 0
0 0 OUT1:Preset output
0
0 0
0 0
0
00
0 0
0 0
99 9 9 9
99 99 9
99 9 9 9
9999 9
+Press for 2sec. or more.
BCD input setting (option)
00 1
<The preset value setting>
<The mode setting>
F.
0
0
0 0
1 00 0
0.0
2
0 0
Press for 2 sec. or more.
<Teaching>
ENT
ENT
ENT
ENT
ENT
ENT
RST
ENT
RST
ENT
RST
ENT
RST
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
Mode
OUT2:Preset output
OUT3:Preset output (option)
OUT4:Preset output (option)
Press for 2 sec. or more.
B input:Setting of scaling data

- 14 -
9.Initial setting values and initialization
If the specifications desired by the user are requested prior to shipment, the meter will be
set these settings. Other wise, the regular factory settings are shown below.
Value setting of each mode (Table 2)
Mode No.
Initial setting Notes
A B C D E B C D E
0. 0 0 2 1
1. 1 0 0 0
2. 3 0 0 2
3. 1 0 0 0
4. 3 0 0 2
5. 1 0 0 0
6. - 0 2. 0 -
7. 0 - 0 0 -
8. 0 0 0 0
9. 0 0 0 0
A. 0 0 0 0
b. 0 0 0 0
C. - 1 0 - - -
d. 1 0 0 0
E.(B)
- - - 0 - - -
F.(BI)
0 - 0 1 -
Presetting output set value (Table 3)
OUTPUT No.
A B C D E
A B C D E
OUT1 9 9 9 9 9
OUT2 9 9 9 9 9
OUT3 9 9 9 9 9
OUT4 9 9 9 9 9
<Initialization>
Throw power supply in with pressed to initialize the settings.
After the initialization, the set values will be as shown in Table 2, Table 3. Mode protect
function are also cleared.
! <Caution>
※Since an initialization changes all existing setting values to the initial setting values,
be sure to record all the setting values before an initialization.
※In case the computer froze when unusual functioning occurred with the normal
operation, initialize according to the above procedure and set the desired value again.
ENT

- 15 -
10.Content and setting the each mode
≪1.Operating method (the mode setting)≫
When doing mode setting, please operate as follows. Table.4
Operating key
Indication Procedure
+
A B C D E
0.0 0 2 1
↓ ↓
Mode No.
Data value
While pushing down , press
for 2 sec. or more.
"0" appears in displays A ,the value
setting for Mode No.0 is shown.
A B C D E
0.0 0 2 1
↑
0 - 9
changes the flash figure.
Each time the key is pressed, a flash fi
gure is rising up.
(0→1→・・・→9→0→1・・・)
※In Situation, doesn't indicate by a set
ting figure,up to nine.
A B C D E
0.9 0 2 1
↑
9 - 0
changes the flash figure.
Each time the key is pressed, a flash
figure is down.
(9→8→・・・→1→0→9・・・)
A B C D E
0.9 0 2 1
→ → →
A figure of flash indication is shifted. Each
time the key is pressed, a flash figure is
shifted, to the right.
A B C D E
1.1 0 0 0
↑
0 - 9, A,b,C,d,E,F
The Mode No. is changed.
Each time is pressed, the Mode No. is
rising. 〔Rise〕
(0→1→・・・→F→0→1・・・)
All modes are "1-F".
When the Mode No. reached "F", return to "0".
After adjusting the setting, use to
register it.
It returns to the measurement display after a
set value is registered.
It returns to the measurement display
without registering a set value.
! <Caution>
※Please make the mode protect function "L-off" at the mode setting. If it's a condition
of "L-on", it can't be changed.
About the contents of the mode protect function, please refer to "11.Mode protect
function".
Mode
Mode
ENT
RST
ENT
Mode
Mode

- 16 -
≪2.Content of the each mode and set value≫
Mode No.
Measuring types, Measurement unit, Display decimal point
0
A B C D E
0.0 0 2 1
Display decimal point setting
0:
0 2:
0.00
1:
0.0 3:0.000
Measuring unit
0:hour
1:minute
2:second
3:hour-minute
The above measurement selecting
4:minute-second
08,13 - 15 alone can be used.
Measuring types
00:
A-input:speed, rotation, flow rate measurement
01:
B-input:speed, rotation, flow rate measurement
02:
Ratio measurement (absolute ratio measurement)
B/A×100
03:Ratio measurement (error ratio measurement)
(B-A)/A×100
04:Ratio measurement (difference measurement)
A-B
05:Ratio measurement (density)
B/(A+B)×100
06:Ratio measurement (sum measurement)
A+B
07:
Ratio measurement (differential rate measurement)
(A+B)/R or (A-B)/R
08:Passing time measurement
09:Shot speed UA (2 sensor one direction speed)
10:Shot speed UB1 (1 senor one direction speed)
11:Shot speed UB2 (1 sensor reciprocal speed)
12:Shot speed UC (2 sensor reciprocal speed)
13:Cycle-timer measurement
14:Stop watch A
15:Stop watch B
NOTE:
Upon setting 16 - 19, same operation as with 00 is mode.
Option:AV3-5/AI
In analog output,
The real-time output functions only when I set Mode No.0 “00”(A input) or
“01”(B input) or “08”(Passing time measurement).
Otherwise, set it in 1(Synchronizes for the display).
When use analog output, the measurement unit choose 0(hour) or
1(minute) or 2(second).
(00)
(01)
〔Ratemeter〕
When I use it in Ratemeter (speed, rotation,flow rate), choose this mode.
Choose “00”(A input) or “01”(B input).

- 17 -
(02)
(03)
(04)
(05)
(06)
〔
Ratio measurement
〕
absolute ratio measurement
・・B/A×100
error ratio measurement
・・・・(B-A)/A×100
difference measurement
・・・・A-B
density・・・・・・・・・・・・・B/(A+B)×100
sum measurement
・・・・・・・A+B
(07)
〔
differential rate measurement
〕
There is a signal of two kinds of number of revolutions of A and B,
The 2 signals are input, and the following calculation is considered to be it.
Furthermore, analog output and the preset output are possible for indication
value data.
1)Calculation type
①A and B turn in the same direction:(A-B)/R
〔Terminal stand 2-3 is a state of OFF〕
②A and B turn to the opposite direction:(A+B)/R
〔Terminal stand 2-3 is a state of ON〕
2)Setting method
①Set scaling of A input and B input
:(Mode No.1-4)
②Deceleration ratio (R) setting
:(Mode No.5)
③Sampling time:(Mode No.6)
④Setting of the preset output(Std.):(Mode No.8,9)
(Option):(Mode No.A,b)
⑤Setting of the analog output.
(Option):(Mode No.C,d)
⑥Setting of the r
everse-rotation input
:(Mode No.7)
3)Operation explanation
①
A input lamp lights up when I push during a measurement,
and number of revolutions of the A input is displayed.
B input lamp lights it up when I push once again and
displays number of revolutions of the B input.
A input lamp and B input lamp turn off the light when I push
once again, and
differential rate
is displayed.
②Reverse-rotation input is shown terminal stand 2-3 when
short-circuit.
When, in this state, I operate the above “①”, Number of
revolutions and
differential rate
of each input are displayed.
Perform the A i
nput with open collector signal or no voltage point
of contact signal
ENT
ENT
ENT
HD
Indicate
Output 1 2
A B
Mode
3 4 ENT
RST