manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Uniphos
  6. •
  7. Water Pump
  8. •
  9. Uniphos UNIPHOS KWIK DRAW ASP-11p Manual

Uniphos UNIPHOS KWIK DRAW ASP-11p Manual

Popular Water Pump manuals by other brands

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Watershed Innovations

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Graco Modu-Flo AL-5M instructions

Graco

Graco Modu-Flo AL-5M instructions

Messner MultiSystem MPF 3000 operating instructions

Messner

Messner MultiSystem MPF 3000 operating instructions

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

Xylem

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

WilTec 50739 Operation manual

WilTec

WilTec 50739 Operation manual

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Franklin Electric

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Ingersoll-Rand PD02P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand PD02P Series Operator's manual

VS ZJ Series Operating	 instruction

VS

VS ZJ Series Operating instruction

Flotec FPZS50RP owner's manual

Flotec

Flotec FPZS50RP owner's manual

SKF Lincoln FlowMaster II User and maintenance instructions

SKF

SKF Lincoln FlowMaster II User and maintenance instructions

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Xylem

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Water Duro Pumps DCJ500 Operating & installation instructions

Water

Water Duro Pumps DCJ500 Operating & installation instructions

Action P490 Operating instructions & parts manual

Action

Action P490 Operating instructions & parts manual

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

Flo King

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

ARO ARO PD15P-X Operator's manual

ARO

ARO ARO PD15P-X Operator's manual

Pumptec 112V Series Operating instructions and parts manual

Pumptec

Pumptec 112V Series Operating instructions and parts manual

Virax 262070 user manual

Virax

Virax 262070 user manual

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UNIPHOS™ ASP-11p Plastic Air Sampling Pump
Operation & Maintenance
1. Introduction
The ASP-11p Air Sampling Pump is designed for use with any brand of gas
detection tubes, thanks to the different adapters that are included. The
UNIPHOS™ ASP-11p Air Sampling Pump allows accurate measurements of
gases with a guaranteed 50cc or 100cc air sample.
2. Operation
Insert the gas detection tube into the tube adapter and twist the tube
while pushing in, to ensure a good seal. You are now ready to make your
measurement. Draw the handle gradually until it reaches the 100, and the
plunger is not drawing back itself, so the vacuum is out of the pump. After
reaching the 100, you are sure you drew a 100cc pump stroke of air
through your detection tube, and you can now read it, or do another
stroke as the manual describes. When you want to do a second pump
stroke, you first have to take out the tube of the pump, then draw the
plunger back, and put back in the tube. You are not ready to make
another pump stroke.
3. Maintenance
To keep making pump strokes go smoothly, regularly grease the inside of
the pump with silicone grease. If you feel making a pump stroke is going
rough, you can decide to grease the inside of the pump by pulling out the
handle first. You can take some silicone grease with your finger or a
brush, and securely grease the inside of the pump. Put the handle back
and make a few pump strokes without inserting a tube, so the grease will
be spread all over the inside of the pump.
g
UNIPHOS™ ASP-11p Plastic Air Sampling Pump
Operation & Maintenance
1. Introduction
The ASP-11p Air Sampling Pump is designed for use with any brand of gas
detection tubes, thanks to the different adapters that are included. The
UNIPHOS™ ASP-11p Air Sampling Pump allows accurate measurements of
gases with a guaranteed 50cc or 100cc air sample.
2. Operation
Insert the gas detection tube into the tube adapter and twist the tube
while pushing in, to ensure a good seal. You are now ready to make your
measurement. Draw the handle gradually until it reaches the 100, and the
plunger is not drawing back itself, so the vacuum is out of the pump. After
reaching the 100, you are sure you drew a 100cc pump stroke of air
through your detection tube, and you can now read it or do another
pump stroke as the manual says. When you want to do another pump
stroke you first have to take out the tube of the pump, then draw the
plunger back, and put back in the tube.
3. Maintenance
To keep making pump strokes go smoothly, regularly grease the inside of
the pump with silicone grease. If you feel making a pump stroke is going
rough, you can decide to grease the inside of the pump by pulling out the
handle first. You can take some silicone grease with your finger or a
brush, and securely grease the inside of the pump. Put the handle back
and make a few pump strokes without inserting a tube, so the grease will
be spread all over the inside of the pump.
4. Leak test
Insert a sealed tube into the tube holder tightly. Pull the handle firmly
until it reaches 100 on the scale. Hold it like that for 30 seconds, and then
gradually let the handle draw back. If the handle is fully drawn back, you
are sure there has been a vacuum inside the pump all the time, that the
pump is not leak, and you will be able to use the pump as described. If a
leak is discovered, we recommend to use a new pump or send it back for
repair.
UNIPHOS™ Gas Detection
powered by 7Solutions B.V.
Hoofdweg 36A
2908LC Capelle a/d IJssel
The Netherlands
T.: +31 (0)10 –279 99 91
F.: +31 (0)10 –441 41 42
[email protected]
www.GasDetectorTubes.com
4. Leak test
Insert a sealed tube into the tube holder tightly. Pull the handle firmly
until it reaches 100 on the scale. Hold it like that for 30 seconds, and then
gradually let the handle draw back. If the handle is fully drawn back, you
are sure there has been a vacuum inside the pump all the time, that the
pump is not leak, and you will be able to use the pump as described. If a
leak is discovered, we recommend to use a new pump or send it back for
repair.