UNITTA U-508 User manual

SonicBeltTensionMeter
U-508OperationManual
Contents
1.Precautions P1
P3
P4
P5
P7
P8
2.Briefsummary,caution&check
pointsforthefailure
3.MeasurementprincipleofU-508
4.ExplanationofthepartsofU-508
mainbody
5.OperationprocedureofU-508
6.Howtoinputthedata
6-1Howtoinputtheunitmass
7.Unitmasstableofthe
preinstalledbelt
6-2Howtoinputthebeltwidthorthenumberofbelts(ribs)
6-3Howtoinputthevalueofspanlength
8.UnitmasstableofGateUnitta
Asiatoothshapetimingbelt
9.TheunitmasstableofVbelt
madebyGates
10.Thestandardinstallationtension
tableoftheGUAtimingbelt
P9
P 10
11.SpecificationofU-508
12.Guarantee&RepairGuidelines
P 12
P11
P10
P 13
ThismanualdescribesoperationprocedureofU-508.
Pleasereadthismanualthoroughlybeforeforfulluseoffunctions.
U-508MANUALV01
HEADOFFICE4-26SAKURAGAWA4-CHOME,NANIWA-KUOSAKA556-0022.JAPAN
TEL:06-6563-1284 FAX:06-6563-1285

1
2
Danger
■Pleasereadthisprecautionscarefully.AndKeepthismanual
safeforfuturereference.
■Theseprecautionsarewrittentodefendtheusertokeep
otherpeoplefromharm,andtopreventotherdamages.
Pleasepayattentiontotheseprecautions.
■Thesesignsindicatethelevelofdangerwhichcanbe
expectedbyimproperuse.
1. Precautions
Imminentlydangerous
situation,suchasdeath
orsevereinjury
Warning
Cancausebreakdown,
injury,andelectric
shock
Caution
Caution
Injuryorphysical
damages
ThingstheusermustNOTdo.
Thingstheusermustdo.
Avoidkeepingattheplace
wheremuchhumidity,dustand
hightemperaturearepresent.
●Cancausethebreakdown
Donotleaveorusethis
sensorinthedirectsunlight
orhightemperatureplace.
Donotputonanunstable
placelikeaslopingtable.
●Cancauseinjuryorbreakdown
Pleasemeasurethetensile
forceafterconfirmingthe
machinehasbeenturnedoff.
Donotmakestrongimpactor
throw.
●Cancausebreakdownandfire
Donotusethisina
flammableenvironment.
●Cancauseanexplosionorthefire
whenusingthisnearpropanegas
orgasoline
Donotbreakdownor
change.
●Cancauseinjury
Eventhoughthearmpartsof
thesensorareflexible,donot
bendatanacuteangle.Please
donotbenditclosetothe
headofthesensor(within
20mmfromthesensor),and
alsodonotbenditatthe
bottomofthesensor.Donot
grabortwirlthecordstrongly.
Pleaseturnoffthepower,
immediatelyrightafteryou
hearathundernoiseand
movetoasafetyplace.
●Cancauseanelectricshock
Donotputliquidssuchas
waterorsolventsonthe
meter.Donotusethesensor
inawetoroilyenvironment.
Donotusesolvents(thinner
andbenzene,etc.)for
maintenance.
Warning

1
2
Danger
■Pleasereadthisprecautionscarefully.AndKeepthismanual
safeforfuturereference.
■Theseprecautionsarewrittentodefendtheusertokeep
otherpeoplefromharm,andtopreventotherdamages.
Pleasepayattentiontotheseprecautions.
■Thesesignsindicatethelevelofdangerwhichcanbe
expectedbyimproperuse.
1. Precautions
Imminentlydangerous
situation,suchasdeath
orsevereinjury
Warning
Cancausebreakdown,
injury,andelectric
shock
Caution
Caution
Injuryorphysical
damages
ThingstheusermustNOTdo.
Thingstheusermustdo.
Avoidkeepingattheplace
wheremuchhumidity,dustand
hightemperaturearepresent.
●Cancausethebreakdown
Donotleaveorusethis
sensorinthedirectsunlight
orhightemperatureplace.
Donotputonanunstable
placelikeaslopingtable.
●Cancauseinjuryorbreakdown
Pleasemeasurethetensile
forceafterconfirmingthe
machinehasbeenturnedoff.
Donotmakestrongimpactor
throw.
●Cancausebreakdownandfire
Donotusethisina
flammableenvironment.
●Cancauseanexplosionorthefire
whenusingthisnearpropanegas
orgasoline
Donotbreakdownor
change.
●Cancauseinjury
Eventhoughthearmpartsof
thesensorareflexible,donot
bendatanacuteangle.Please
donotbenditclosetothe
headofthesensor(within
20mmfromthesensor),and
alsodonotbenditatthe
bottomofthesensor.Donot
grabortwirlthecordstrongly.
Pleaseturnoffthepower,
immediatelyrightafteryou
hearathundernoiseand
movetoasafetyplace.
●Cancauseanelectricshock
Donotputliquidssuchas
waterorsolventsonthe
meter.Donotusethesensor
inawetoroilyenvironment.
Donotusesolvents(thinner
andbenzene,etc.)for
maintenance.
Warning

3
4
Fig.1OsciIlationattenuationoftimingbelt
150
100
50
0 50 100 150
2
Timingbeit:
3GTtoothshape×3
mm
wide
(V)
0
-2 TIME A LIN
80
m
S
2.
Briefsummary,caution&checkpointsforfailure
3.MeasurementprincipleofU-508
Thesonicbelttensionmeter(U-508)is
thehandyequipmentwhichenablesto
measurethetensionaccuratelyby
analyzingsonicwavewithouttouching.
Asensorcatchestheproduced
eruptionofsoundwavebypickthebelt
span.Afterthat,thehighprocessing
computeranalyzesitandshowstheresult
onthescreendigitally.
Whenwemakeabeltbetweenpulleys
vibratebygivingimpact,itstartsto
oscillateirregularlyasseeninFig.1,but
graduallyitoscillatesaninherentregular
moves.
TheU-508tensionmeterwascreatedto
addressthisphenomenon.Inthepast,
therewasnoeasilyimplementeddevice
whichcouldcatchthesesmallwaves.
Wesucceededincatchingtheperiodof
wavepatternrelativelyeasilyby
developingadatahandlingmethodto
capturethevibrationfrequencythatmade
fulluseofmicrocomputer.
Asforthesystem,sensordetectsthe
vibrationwaveform,microcomputer
calculatesthecharactervibrationnumber
byprocessingthedata.
Tocalculatethebelttension,weusethe
transversevibrationofthethreadfor
settingatatensionasrightside.
Here,thebeltandthewirehavearigidity,
whichisdifferentfromthestring,therefore
U-508measurementdisplayedis
somewhathigherthantheactualtension
undertheaffectedcondition.
Therefore,itispossibletoobtain
correctionfactorbystrictcalibrationtest
andincorporateittothedatainput,
therebyitcandisplaymoreaccurate
tension.
AnexampleofcalibrationresultofU-508
measurementandactualtensionisshown
below:
CalculationTo=4×M×W×S2
×f2
×10 -9
To
:Tension
M:Unitmass
W:Beltwidthornumberofribs(wires)
S :Measuredspanlength
f :Horizontalcharacteristicfrequency
(N)
(g/
mm
width×mlength)
(
mm
/R)
(
mm
)
(Hz)
■Briefsummary
■Checkpointsfortheimmeasurablestate
[Failedtomeasureortheresultswerefluctuatedsignificantly.]
ITEM
*PleaseinquiretousorthedealerwhereyoupurchasediftheU-508doesnotworkafterchecking
thepointsabove.
PRESUMED PRESUMEDCAUSE CONFIRMATIONPONT
"Error"showsupor
themeasuremode
cannotbeengaged
ortheredlighton.
Theunevennessof
theoutputlevelis
large.
●Nothingshows
uporonly
measuring
processingsign
showsupfrom
thethirdtimeof
measurin
(Frequency
mode)
●Themeasured
valuechanges
everytimegreatly
●Thesensor
respondstothe
backgroundnoise
keenly
●"0"isenteredtotheunitmass,
width&span
●Inputthewrongfrequencyrange
●Measuredfrequencyexceeds
5000Hs
●Batterydrain
●Thesensorattachestoabeltfor
amoment
●Automaticgainadjustmentisnot
enough
●Checktheentereddata(Input
thecorrectnumber)
●Thefrequencydisplays,butthe
tensiondoesnotmeasure
●Changethemeasurement
frequencyrange
(STANDARD⇔HIGH)
●Checkwhetherthemeasurement
frequencyexceeds5000Hzor
not
●Batterydrain
●Measureagainkeepingenough
distancesothatthesensordoes
notattachtoabelt
●Turnoffapoweronceatthe
measurementplace,thenturnit
on
(Turnonapowerwith
connectedthesensor,thenpush
"MEASURE"buttonafterone
second
Therefore,itisrequiredtoinputthelengthof
span to be measured and the mass of beIt
(unitmassxwidth)byuseofnumerickey.
3GTbalt
Actualtension(N)
U-508measuredvalue(N)
:Spanlength86
mm
:Spanlength 154
mm
:Spanlength365
mm
:Spanlength365
mm
[9
mm
wide]
Standardinstalation
tensionofbelt
9mmwide
Standardinstalation
tensionofbelt
6mmwide
[6
mm
wide]
Fig.2U-508relationbetweenmeasured
valueandactualtension
0
100
200
300
400
500
600
100 200 300 400 500 600
Actualtension(N)
U-508measuredvalue(N)
Typicalterisionwhen
sfrbtchingagain
Typical
lnstallation
tension
V-ribbedbelt
:Spanlength102
mm
:Spanlength201
mm
:Spanlength400
mm

3
4
Fig.1OsciIlationattenuationoftimingbelt
150
100
50
0 50 100 150
2
Timingbeit:
3GTtoothshape×3
mm
wide
(V)
0
-2 TIME A LIN
80
m
S
2.
Briefsummary,caution&checkpointsforfailure
3.MeasurementprincipleofU-508
Thesonicbelttensionmeter(U-508)is
thehandyequipmentwhichenablesto
measurethetensionaccuratelyby
analyzingsonicwavewithouttouching.
Asensorcatchestheproduced
eruptionofsoundwavebypickthebelt
span.Afterthat,thehighprocessing
computeranalyzesitandshowstheresult
onthescreendigitally.
Whenwemakeabeltbetweenpulleys
vibratebygivingimpact,itstartsto
oscillateirregularlyasseeninFig.1,but
graduallyitoscillatesaninherentregular
moves.
TheU-508tensionmeterwascreatedto
addressthisphenomenon.Inthepast,
therewasnoeasilyimplementeddevice
whichcouldcatchthesesmallwaves.
Wesucceededincatchingtheperiodof
wavepatternrelativelyeasilyby
developingadatahandlingmethodto
capturethevibrationfrequencythatmade
fulluseofmicrocomputer.
Asforthesystem,sensordetectsthe
vibrationwaveform,microcomputer
calculatesthecharactervibrationnumber
byprocessingthedata.
Tocalculatethebelttension,weusethe
transversevibrationofthethreadfor
settingatatensionasrightside.
Here,thebeltandthewirehavearigidity,
whichisdifferentfromthestring,therefore
U-508measurementdisplayedis
somewhathigherthantheactualtension
undertheaffectedcondition.
Therefore,itispossibletoobtain
correctionfactorbystrictcalibrationtest
andincorporateittothedatainput,
therebyitcandisplaymoreaccurate
tension.
AnexampleofcalibrationresultofU-508
measurementandactualtensionisshown
below:
CalculationTo=4×M×W×S2
×f2
×10 -9
To
:Tension
M:Unitmass
W:Beltwidthornumberofribs(wires)
S :Measuredspanlength
f :Horizontalcharacteristicfrequency
(N)
(g/
mm
width×mlength)
(
mm
/R)
(
mm
)
(Hz)
■Briefsummary
■Checkpointsfortheimmeasurablestate
[Failedtomeasureortheresultswerefluctuatedsignificantly.]
ITEM
*PleaseinquiretousorthedealerwhereyoupurchasediftheU-508doesnotworkafterchecking
thepointsabove.
PRESUMED PRESUMEDCAUSE CONFIRMATIONPONT
"Error"showsupor
themeasuremode
cannotbeengaged
ortheredlighton.
Theunevennessof
theoutputlevelis
large.
●Nothingshows
uporonly
measuring
processingsign
showsupfrom
thethirdtimeof
measurin
(Frequency
mode)
●Themeasured
valuechanges
everytimegreatly
●Thesensor
respondstothe
backgroundnoise
keenly
●"0"isenteredtotheunitmass,
width&span
●Inputthewrongfrequencyrange
●Measuredfrequencyexceeds
5000Hs
●Batterydrain
●Thesensorattachestoabeltfor
amoment
●Automaticgainadjustmentisnot
enough
●Checktheentereddata(Input
thecorrectnumber)
●Thefrequencydisplays,butthe
tensiondoesnotmeasure
●Changethemeasurement
frequencyrange
(STANDARD⇔HIGH)
●Checkwhetherthemeasurement
frequencyexceeds5000Hzor
not
●Batterydrain
●Measureagainkeepingenough
distancesothatthesensordoes
notattachtoabelt
●Turnoffapoweronceatthe
measurementplace,thenturnit
on
(Turnonapowerwith
connectedthesensor,thenpush
"MEASURE"buttonafterone
second
Therefore,itisrequiredtoinputthelengthof
span to be measured and the mass of beIt
(unitmassxwidth)byuseofnumerickey.
3GTbalt
Actualtension(N)
U-508measuredvalue(N)
:Spanlength86
mm
:Spanlength 154
mm
:Spanlength365
mm
:Spanlength365
mm
[9
mm
wide]
Standardinstalation
tensionofbelt
9mmwide
Standardinstalation
tensionofbelt
6mmwide
[6
mm
wide]
Fig.2U-508relationbetweenmeasured
valueandactualtension
0
100
200
300
400
500
600
100 200 300 400 500 600
Actualtension(N)
U-508measuredvalue(N)
Typicalterisionwhen
sfrbtchingagain
Typical
lnstallation
tension
V-ribbedbelt
:Spanlength102
mm
:Spanlength201
mm
:Spanlength400
mm

5
6
1.PressMEASUREbuttontosetupautotriggermode.
※Initiallyisshown.
※Duringmeasurementisshown.
Themeasurementstartsafterreceivingasignalfromasensor
2.ItwillstartmeasuringafterselectingbelttypeandpressMEASUREbutton.
3.Afterchangingmeasuringfrequencyrange,pressMEASUREbuttonformeasuringchanged
frequencyrange.
MEASURE
10
Thissensorhasnarrowpathofφ12.5mmandaction-pipewhichcansetasensorpositionhandily.
Itisbestusedwhenonecannotputthemainbodyonthefloor.
Flexiblesensor
(Standardmodel)
11
One-touch
connector
Thereisthehollowofadent,insertaconvexconnectoratthetop.
Toremoveaconnector,slidethejointpartandpullout.
1
Powerbutton PressthepowerbuttontoturnU-508on.
Itwillautomaticallyturnofffiveminutesafterthelastmeasure.
2
●【Toshowthepreinstalledmass】
BelttypecategoryisshownupbypressingMASSbuttonmorethanonesecond.
AndchoosebyUPorDOWNbuttonandpushMEASUREbuttonforconfirmation.
*Showingunit:g/m.
*CAT(roughstandard),tensionandfrequencywon'tbeshownwithoutselectingbelttype.
5
Selectbutton ●【Memoryofmeasuringcondition】
PressSELECTbuttontochooseanydesiredinputnumberdisplayedinpower-on.
40memoryfunctionsselectablefromNo.0to39
*Topasson,pressSELECTbuttonbacktoback,tojumpinthenumber,pressthewished
numberdirectlyonit.
Pleasepressthenumbercontinuouslytocalloutlargerthanthenumberten.
●【Calloutthemeasuredresult】
Itisabletoconfirmthelatest500databypressingmorethanonesecond.
Toselecttheresult,pressUPorDOWMbutton.Tojumpthedata,Pressthosebuttonmorethan
onesecond.
*TheresultisrecordedinorderfromRec.001,itwillbeoverwrittenwhentherecordsstraythe
latest500results.
4
WIDTHbutton ●PressWIDTHbuttonforputtingthewidthofthebeltwithnumerickey.
*Entercapacity:000.1-999.9mm/R
*EnterthenumberofribsforVbelt.
6
SPANbutton ●PressSPANbuttonforputtingthewidthofthebeltspannumerickey.
7
Hzbutton
(switching
frequencyand
tension))
●PressHzbuttonforselectingfrequencyor
tension.
*Themodechangeseverytimethisbuttonis
pressed.
●PressHzbuttonmorethanonesecondtoshow
bothrecordswithtensionandfrequency.
8
0/RANGE
button(switch
frequency
range)
Press0/RANGEbuttonmorethanonesecondtochangemeasurementfrequencyrange.
HIGH…………500〜5000Hz
STANDARD…10〜600Hz
※ChangetoHIGHformeasuringover600Hz
9
Therearefourkindsofsensors.
Cordtype Because the sizeofthissenorisanarrow pathofφ 12.5mm,itismeasurableby
everyplaces.
Flat type This is the free pipe of the flat shape with thickness 10mm and 20mm in width.
Especiallyfortherightangledirectioninaparticularlysmallplace.
Long arm type By using this sensor, it is possible to measure that the main body is hard to
reach.
Electromagnetictype Thisreacttotheelectromagneticvibration,unaffectedbytheneighboring
noise,themeasurementispossibleunderthevibrationdecrementearly.
However, an application such as the pasting of a thin magnetic film or the magnetic paint is
necessaryforameasurementsideinthecaseofarubberbelt.
ThiscableconnectsU-508withPCs,andtransferthemeasureddata.
Sensor
(Option)
USBcablefortransfer
12
13
4.
ExplanationofthepartsofU-508mainbody
Flexiblearmsensor
(Standard)
11
One-touchconnector
1
Measurebutton
(Decisionbutton)
10
Powerbutton
2
●Cordtypesensor
Sensor(Option)
12
●Flatflexiblesensor
Sensor
●Longarmsensor
●Electromagneticsensor
USBcableisnotattached.
Pleaseuseacommercialone.(Mini-B5type)
13
LCSwithbacklight
3
Spanbutton
7
Selectbutton
(Callbuttonof
measuredresults)
Powersupply:TripleAtypex2pieces
4
Hzbutton
(changeafrequency⇔tension)
8
LED
(Left:Red,Right:Green)
Widthbutton
6
Massbutton
5
O/Rangebutton
Changeafrequencyrange
9
UP/DOWN
button
5
S No 01 5GT
RESULT
TEN N
S No 01 5GT
RESULT
FREQ Hz
Measuredtension
S No 01 5GT
RESULT
FREQ Hz
TEN N
Measuredtension&frequency
S No 01 5GT
FREQUENCY
CAT Hz
RES Hz
Frequency&Catalogfrequency
S No 01 5GT
Tension&Catalogtension
Measuredtension&Frequency
TENSION
CAT N
RES N
LCDscreen
with
backlight.
Thisdisplays
tensionvalue
3
S No 00
M 9 9 9. 9 g/m
W 9 9 9 .9 mm/R
S 9 9 9 9 mm
S No 00 2GT
TENSION
99900 N
Measurement
frequencylevel
H:HIGH
S:STANDARD
MemoryNo.
Themeasuredresult
Inmeasurementofbelttype
Batteryresidualquantity
【OverviewofLCDshowingpattern】
Note:Thiswillbe
shownonlyfromthe
pre-installationone.
Unitmassbeltwidthspanindicationexample
●Tensionnumericalnumberisshownbythreedigitsfrom
0.01〜99,900.
●Frequencynumericalnumberisshownbythreedigits
from10.0〜5,000Hz.
●TheredlightandERRORwillbeshownonthescreen
whentheresultofthemeasureisoutofthestandard
range.
NOTE:Ifthestandardrangeoveroccursaftertheresultis
shown,itbeepstwiceuntilthesecondmeasure.
●Abatterytypesignatureatthetimeofthebattery
consumptionisshown.
LOWBATTblinksonandoffwhenthebatteryislow.
●Abacklightisalwaysonbutitwillturnoffafterno
operationforoneminute.
H No 00 EV8YU
T Belt
V Belt
U Belt
Belt
S No 02 2GT
3GT 2.5
2GT 1.3
01
03
02
1.5GT 0.9
MASSbutton
S No 01
STANDARD
HIGH
ByUPorDOWNbuttontochoosetherange,andpress
MEASUREbuttonforconfirmation.
350mm
※USBcableinNOTincludedinthepackage.
PleaseusetheMINI-B5pin.

5
6
1.PressMEASUREbuttontosetupautotriggermode.
※Initiallyisshown.
※Duringmeasurementisshown.
Themeasurementstartsafterreceivingasignalfromasensor
2.ItwillstartmeasuringafterselectingbelttypeandpressMEASUREbutton.
3.Afterchangingmeasuringfrequencyrange,pressMEASUREbuttonformeasuringchanged
frequencyrange.
MEASURE
10
Thissensorhasnarrowpathofφ12.5mmandaction-pipewhichcansetasensorpositionhandily.
Itisbestusedwhenonecannotputthemainbodyonthefloor.
Flexiblesensor
(Standardmodel)
11
One-touch
connector
Thereisthehollowofadent,insertaconvexconnectoratthetop.
Toremoveaconnector,slidethejointpartandpullout.
1
Powerbutton PressthepowerbuttontoturnU-508on.
Itwillautomaticallyturnofffiveminutesafterthelastmeasure.
2
●【Toshowthepreinstalledmass】
BelttypecategoryisshownupbypressingMASSbuttonmorethanonesecond.
AndchoosebyUPorDOWNbuttonandpushMEASUREbuttonforconfirmation.
*Showingunit:g/m.
*CAT(roughstandard),tensionandfrequencywon'tbeshownwithoutselectingbelttype.
5
Selectbutton ●【Memoryofmeasuringcondition】
PressSELECTbuttontochooseanydesiredinputnumberdisplayedinpower-on.
40memoryfunctionsselectablefromNo.0to39
*Topasson,pressSELECTbuttonbacktoback,tojumpinthenumber,pressthewished
numberdirectlyonit.
Pleasepressthenumbercontinuouslytocalloutlargerthanthenumberten.
●【Calloutthemeasuredresult】
Itisabletoconfirmthelatest500databypressingmorethanonesecond.
Toselecttheresult,pressUPorDOWMbutton.Tojumpthedata,Pressthosebuttonmorethan
onesecond.
*TheresultisrecordedinorderfromRec.001,itwillbeoverwrittenwhentherecordsstraythe
latest500results.
4
WIDTHbutton ●PressWIDTHbuttonforputtingthewidthofthebeltwithnumerickey.
*Entercapacity:000.1-999.9mm/R
*EnterthenumberofribsforVbelt.
6
SPANbutton ●PressSPANbuttonforputtingthewidthofthebeltspannumerickey.
7
Hzbutton
(switching
frequencyand
tension))
●PressHzbuttonforselectingfrequencyor
tension.
*Themodechangeseverytimethisbuttonis
pressed.
●PressHzbuttonmorethanonesecondtoshow
bothrecordswithtensionandfrequency.
8
0/RANGE
button(switch
frequency
range)
Press0/RANGEbuttonmorethanonesecondtochangemeasurementfrequencyrange.
HIGH…………500〜5000Hz
STANDARD…10〜600Hz
※ChangetoHIGHformeasuringover600Hz
9
Therearefourkindsofsensors.
Cordtype Because the sizeofthissenorisanarrow pathofφ 12.5mm,itismeasurableby
everyplaces.
Flat type This is the free pipe of the flat shape with thickness 10mm and 20mm in width.
Especiallyfortherightangledirectioninaparticularlysmallplace.
Long arm type By using this sensor, it is possible to measure that the main body is hard to
reach.
Electromagnetictype Thisreacttotheelectromagneticvibration,unaffectedbytheneighboring
noise,themeasurementispossibleunderthevibrationdecrementearly.
However, an application such as the pasting of a thin magnetic film or the magnetic paint is
necessaryforameasurementsideinthecaseofarubberbelt.
ThiscableconnectsU-508withPCs,andtransferthemeasureddata.
Sensor
(Option)
USBcablefortransfer
12
13
4.
ExplanationofthepartsofU-508mainbody
Flexiblearmsensor
(Standard)
11
One-touchconnector
1
Measurebutton
(Decisionbutton)
10
Powerbutton
2
●Cordtypesensor
Sensor(Option)
12
●Flatflexiblesensor
Sensor
●Longarmsensor
●Electromagneticsensor
USBcableisnotattached.
Pleaseuseacommercialone.(Mini-B5type)
13
LCSwithbacklight
3
Spanbutton
7
Selectbutton
(Callbuttonof
measuredresults)
Powersupply:TripleAtypex2pieces
4
Hzbutton
(changeafrequency⇔tension)
8
LED
(Left:Red,Right:Green)
Widthbutton
6
Massbutton
5
O/Rangebutton
Changeafrequencyrange
9
UP/DOWN
button
5
S No 01 5GT
RESULT
TEN N
S No 01 5GT
RESULT
FREQ Hz
Measuredtension
S No 01 5GT
RESULT
FREQ Hz
TEN N
Measuredtension&frequency
S No 01 5GT
FREQUENCY
CAT Hz
RES Hz
Frequency&Catalogfrequency
S No 01 5GT
Tension&Catalogtension
Measuredtension&Frequency
TENSION
CAT N
RES N
LCDscreen
with
backlight.
Thisdisplays
tensionvalue
3
S No 00
M 9 9 9. 9 g/m
W 9 9 9 .9 mm/R
S 9 9 9 9 mm
S No 00 2GT
TENSION
99900 N
Measurement
frequencylevel
H:HIGH
S:STANDARD
MemoryNo.
Themeasuredresult
Inmeasurementofbelttype
Batteryresidualquantity
【OverviewofLCDshowingpattern】
Note:Thiswillbe
shownonlyfromthe
pre-installationone.
Unitmassbeltwidthspanindicationexample
●Tensionnumericalnumberisshownbythreedigitsfrom
0.01〜99,900.
●Frequencynumericalnumberisshownbythreedigits
from10.0〜5,000Hz.
●TheredlightandERRORwillbeshownonthescreen
whentheresultofthemeasureisoutofthestandard
range.
NOTE:Ifthestandardrangeoveroccursaftertheresultis
shown,itbeepstwiceuntilthesecondmeasure.
●Abatterytypesignatureatthetimeofthebattery
consumptionisshown.
LOWBATTblinksonandoffwhenthebatteryislow.
●Abacklightisalwaysonbutitwillturnoffafterno
operationforoneminute.
H No 00 EV8YU
T Belt
V Belt
U Belt
Belt
S No 02 2GT
3GT 2.5
2GT 1.3
01
03
02
1.5GT 0.9
MASSbutton
S No 01
STANDARD
HIGH
ByUPorDOWNbuttontochoosetherange,andpress
MEASUREbuttonforconfirmation.
350mm
※USBcableinNOTincludedinthepackage.
PleaseusetheMINI-B5pin.

7
8
Setupthesensor. Chooseanoptimumsensorandfixinthemainbody
withone-touchconnector.
1
Turnonpower. POWERbutton−PUSH No
No
No00 →No01
No01→No02
No00→No02
2
InputNo.bynumericalkeypador
selectbutton.
SELECTbutton−PUSH
【Numberisforwardedsequentaltyeverytime
SELECTbuttonispressed.00→01→・・→38→39
→00→01→02→Inaddition,youcanjumptoany
designatednumberbypressinganumberwith
numerickey.】
Selectingprocedure
SELECTbutton−PUSH(1sttime)
SELECTbutton−PUSH(2ndtime)
Selectingprocedure
2button−PUSH
WhenSELECTbuttonispressedduringthe
followingprocedure(duringdisplayofunitmass,
beltwidth,spanlengthinput,andmeasuredvalue),
thenumberbeingchosenisdisplayed.
3
EX:Selectfrom00toNo.02
Caseofinputtingaunitmass
manually.
Caseofinputtingtheunitmass
frombelttype.
EX:Select3GT.
[Seepage9forinputdata.]
[Seepage8forinputdata.]
[Seepage8forinputdate.]
EX:Put2.5g/mmwidexmeter
long
Inputthebeltwidth.
EX:Put25.4mm.
MASSbutton−PUSH
[Inputtheunitmass(g/mmWxmL)intheorderof
blinkingpositionondisplayscreenbyuseofnumeric
key.Ifyouinputwrongnumber,press"MASS"button
againtoreturnthecursortothefirst.]
0button−PUSH
0button−PUSH
2button−PUSH
5button−PUSH
●"MASS"button
−
PUSH(holdingdownmorethan
onesecond)Beltcategory(T,V,U)isshownonscreen
bypressingMASSbuttonnmorethanonesecond.
ByusingUPorDOWNbuttontoselectthebelt
category.
●"MEASURE"button
−
PUSH
Belttypeisshownonscreen,choosebelttypeby
UPorDOWNbutton
●"DOWN"button
−
PUSH
Placehighlightedportionon3GT.
●"MEASURE"
−
PUSH
3GTisdisplayedonscreen.
4-1
4-2
WIDTHbutton−PUSH
【Dothesameasdescribedabove.Whendata
abovealIowablecapacityisinput,thecursorreturns
tothefirst,andinputofdataisrequestedagain.】
0button−PUSH
2button−PUSH
5button−PUSH
4button−PUSH
5
Inputthespanlength. SPANbutton−PUSH
【Dothesameasdescribedabove.】
6
Procedure
Description Operation Displayscreen
5.OperationprocedureofU-508
1
2
S= □□□
mm
『
Allowableinputcapacity:
0001 〜 9999 m m
』
W= □□.□mm/R
『
Allowableinputcapacity:
000.1〜999.9m m
』
W=0 □.□mm/R
W=02 .□mm/R
W=025. mm/R
W=025.4m m / R
M= □□.□g/m
『
Allowableinputcapacity:
0.1〜999.9g / m m×m
』
M=0 □.□g/m
M=00 .□g/m
M=002. g/m
M=0 02.5g / m
Showsfrequencyafter
measurementoftension.
Showstheresultof
measurement.
"Hz"button−PUSH
[Showsfrequencycorrespondingtothemeasured
tension.
When"Hz"buttonispressedonceagain,thedisplay
returnstotensionmode.]
"Hz"button−PUSH
[Showsfrequencycorrespondingtothemeasured
tension.
※When"Hz"buttonispressedonceagain,the
displayreturnstotensionmode.]
Tocallthelatest500records,pressSELECT
buttonmorethanasecondontheSELECTscreen.
SELECTbutton−PUSH
Showsmeasurementfrequency,tension,unitmassat
themeasurement.
Gobacktotheselectscreen.
※Toerasethemeasureddatecanbecleared
collectivelyonlywhenitconnectswithPC.
8-2
9
※PleasechecktheU-508applicationsoftwaremanualforhowtoexportthedatatoPC.
T Belt
V Belt
U Belt
Belt
S No 02 2GT
S No 02 2GT
3GT 2.5
2GT 1.3
01
03
02
1.5GT 0.9
Showstension. ※Indicationexamplefor
upperlowerlimitareset
Howeverpleasematch
indicationwithtension
indication(frequency
indication)whenyouset
thetensionlevel
(frequency).Theupper
lowerlimitsettingwitha
PC.
8-1
Startmeasurement. Getsensorincentralspanofthemeasureobject
withouttouchingit.
"MEASURE"button−PUSH:LED(green)blinks,
shows.
Tovibratethewire,flipthebeltspanwitha
fingeretc.:shows.
Thefollowingmeasurementisperformedbythe
sensorreceivingsoundwithoutuseofmeasure
buttonfromthesecondtime.
Sincemeasurementisstartedbythesenor
receivingsound,itisstartedaswellevenbya
noiseifithasarelativelystablesoundpressure.
Resultisshownaswellasbeepsoundemitted
andLED(green)turnsonin1.2secondafter
receptionofbeltvibrationsound.
[Afterthesecond
measurement,please
noticethatthescreen
showsthedatapreviously
measured.
Andyouhearthebeep,
thenewdatawillbe
displayedonthescreen.]
71
2
3
72.4 HIGH
N
TENSION
HIGH:Abovethesetting
GOOD:Withinsettingrange
LOW:Belowthesetting
S No 02 2GT

7
8
Setupthesensor. Chooseanoptimumsensorandfixinthemainbody
withone-touchconnector.
1
Turnonpower. POWERbutton−PUSH No
No
No00 →No01
No01→No02
No00→No02
2
InputNo.bynumericalkeypador
selectbutton.
SELECTbutton−PUSH
【Numberisforwardedsequentaltyeverytime
SELECTbuttonispressed.00→01→・・→38→39
→00→01→02→Inaddition,youcanjumptoany
designatednumberbypressinganumberwith
numerickey.】
Selectingprocedure
SELECTbutton−PUSH(1sttime)
SELECTbutton−PUSH(2ndtime)
Selectingprocedure
2button−PUSH
WhenSELECTbuttonispressedduringthe
followingprocedure(duringdisplayofunitmass,
beltwidth,spanlengthinput,andmeasuredvalue),
thenumberbeingchosenisdisplayed.
3
EX:Selectfrom00toNo.02
Caseofinputtingaunitmass
manually.
Caseofinputtingtheunitmass
frombelttype.
EX:Select3GT.
[Seepage9forinputdata.]
[Seepage8forinputdata.]
[Seepage8forinputdate.]
EX:Put2.5g/mmwidexmeter
long
Inputthebeltwidth.
EX:Put25.4mm.
MASSbutton−PUSH
[Inputtheunitmass(g/mmWxmL)intheorderof
blinkingpositionondisplayscreenbyuseofnumeric
key.Ifyouinputwrongnumber,press"MASS"button
againtoreturnthecursortothefirst.]
0button−PUSH
0button−PUSH
2button−PUSH
5button−PUSH
●"MASS"button
−
PUSH(holdingdownmorethan
onesecond)Beltcategory(T,V,U)isshownonscreen
bypressingMASSbuttonnmorethanonesecond.
ByusingUPorDOWNbuttontoselectthebelt
category.
●"MEASURE"button
−
PUSH
Belttypeisshownonscreen,choosebelttypeby
UPorDOWNbutton
●"DOWN"button
−
PUSH
Placehighlightedportionon3GT.
●"MEASURE"
−
PUSH
3GTisdisplayedonscreen.
4-1
4-2
WIDTHbutton−PUSH
【Dothesameasdescribedabove.Whendata
abovealIowablecapacityisinput,thecursorreturns
tothefirst,andinputofdataisrequestedagain.】
0button−PUSH
2button−PUSH
5button−PUSH
4button−PUSH
5
Inputthespanlength. SPANbutton−PUSH
【Dothesameasdescribedabove.】
6
Procedure
Description Operation Displayscreen
5.OperationprocedureofU-508
1
2
S= □□□
mm
『
Allowableinputcapacity:
0001 〜 9999 m m
』
W= □□.□mm/R
『
Allowableinputcapacity:
000.1〜999.9m m
』
W=0 □.□mm/R
W=02 .□mm/R
W=025. mm/R
W=025.4m m / R
M= □□.□g/m
『
Allowableinputcapacity:
0.1〜999.9g / m m×m
』
M=0 □.□g/m
M=00 .□g/m
M=002. g/m
M=0 02.5g / m
Showsfrequencyafter
measurementoftension.
Showstheresultof
measurement.
"Hz"button−PUSH
[Showsfrequencycorrespondingtothemeasured
tension.
When"Hz"buttonispressedonceagain,thedisplay
returnstotensionmode.]
"Hz"button−PUSH
[Showsfrequencycorrespondingtothemeasured
tension.
※When"Hz"buttonispressedonceagain,the
displayreturnstotensionmode.]
Tocallthelatest500records,pressSELECT
buttonmorethanasecondontheSELECTscreen.
SELECTbutton−PUSH
Showsmeasurementfrequency,tension,unitmassat
themeasurement.
Gobacktotheselectscreen.
※Toerasethemeasureddatecanbecleared
collectivelyonlywhenitconnectswithPC.
8-2
9
※PleasechecktheU-508applicationsoftwaremanualforhowtoexportthedatatoPC.
T Belt
V Belt
U Belt
Belt
S No 02 2GT
S No 02 2GT
3GT 2.5
2GT 1.3
01
03
02
1.5GT 0.9
Showstension. ※Indicationexamplefor
upperlowerlimitareset
Howeverpleasematch
indicationwithtension
indication(frequency
indication)whenyouset
thetensionlevel
(frequency).Theupper
lowerlimitsettingwitha
PC.
8-1
Startmeasurement. Getsensorincentralspanofthemeasureobject
withouttouchingit.
"MEASURE"button−PUSH:LED(green)blinks,
shows.
Tovibratethewire,flipthebeltspanwitha
fingeretc.:shows.
Thefollowingmeasurementisperformedbythe
sensorreceivingsoundwithoutuseofmeasure
buttonfromthesecondtime.
Sincemeasurementisstartedbythesenor
receivingsound,itisstartedaswellevenbya
noiseifithasarelativelystablesoundpressure.
Resultisshownaswellasbeepsoundemitted
andLED(green)turnsonin1.2secondafter
receptionofbeltvibrationsound.
[Afterthesecond
measurement,please
noticethatthescreen
showsthedatapreviously
measured.
Andyouhearthebeep,
thenewdatawillbe
displayedonthescreen.]
71
2
3
72.4 HIGH
N
TENSION
HIGH:Abovethesetting
GOOD:Withinsettingrange
LOW:Belowthesetting
S No 02 2GT

9
10
1
2
3
●Listoftimingbeltunitmassspecifiedasstandardconfiguration
Timingbelt
HTDbelt
GTbelt
4PolychainGTcarbonbelt
5Unittamectrolbelt
6Specialpitchbelt
Toothshape
Pitch(mm)
MXL
2.032
1.2
XXL(50)
3.175
1.4
XL
5.080
2.1
DXL
5.080
1.9
L
9.525
3.1
DL
9.525
3.3
H
12.700
3.8
DH
12.700
4.4
XH
22.225
11.1
XXH
31.750
14.8
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
3M-HTD
3.000
2.4
D3M-HTD
3.000
2.3
5M-HTD
5.000
3.8
D5M-HTD
5.000
4.2
8M-HTD
8.000
6.1
D8M-HTD
8.000
6.3
EV14M
14.000
8.7
EV14M2
14.000
8.3
14M-HTD
14.000
10.0
D14M-HTD
14.000
11.9
20M-HTD
20.000
12.8
8M-GT
8.000
4.7
14M-GT
14.000
8.0
2.0 2.2 3.6 4.3 5.6 9.9 1.9 2.1 3.0 3.5 3.2 3.9 4.1 5.9 5.2 10.7
K S K S S S K S K S K S S S S S
5.000 10.000
10.000 20.000
5.080 9.525 12.700
5.000 8.000 8.000 14.000
T5 T10
AT10 AT20
XL L H 5M 8M 8YU 14M
Toothshape
Pitch(mm)
Unitmass(g/mmwidth×mlength)
Cord
101
1.5875
1.0
102
2.0320
1.3
103
2.1167
1.3
104
2.8222
1.0
111
1.4111
1.1
109
2.1167
1.1
181
2.8222
0.9
25
6.3500
1.7
9109
15.4473
3.0
1.5GT
1.500
0.9
2GT
2.000
1.3
3GT
3.000
2.5
D3GT
3.000
2.5
5GT
5.000
4.0
D5GT
5.000
4.3
EV5GTC
5.000
3.8
EV5GT
5.000
4.0
EV8YU
EV8YUC
EV8YU2
8.000
5.1
8YU
8.000
5.2
8YUF
8.000
6.1
D8YU
8.000
5.4
Refertotheexplanationof"MASS"buttonatpage5and6. Asforthespecialpitchor
thebelt,pleaserefertheunitmasstableonthenextpageandinputcorrectly.
7.
Unitmasstableofthepreinstalledbelt
■Table2:ForU-508,507andU-505,305unitmasstable
Dataofunitmasscanbeinputbyfoursignificantdigits,i.e.threedigitsofintegerand
onedigitbelowdecimalpointing/mmWxmLfrom0.1to999.9g/mmWxmL.
8.
UnitmasstableofGateUnittaAsiatoothshapetimingbelt
Note:Inputwithavalue10timesaslargeasaunitmasslisted(g/cm)usedinU-303(outofsalesmodel).
1.5GT
2GT
3GT
D3GT
5GT
EV5GT
EV5GTC
D5GT
8YU
0.9
1.3
2.5
2.5
4.0
4.0
3.8
4.3
5.2
8YUF
EV8YU
EV8YUC
EV8YU2
D8YU
8MGT
14MGT
EV14M
EV14M2
6.1
5.1
5.1
5.1
5.4
4.7
8.0
8.7
8.3
3M
D3M
5M
D5M
8M
D8M
14M
D14M
20M
2.4
2.3
3.8
4.2
6.1
6.3
10.0
11.9
12.8
MXL
XL
DXL
L
DL
H
DH
XH
XXH
1.2
2.1
1.9
3.1
3.3
3.8
4.4
11.1
14.8
3VX
5VX
8VX
J(V)
PK(V)
L(V)
A(V)
B(V)
C(V)
59.8
165.6
525.6
8.6
20.0
30.4
103.2
166.0
298.8
D(V)
E(V)
3VXPB
5VXPB
5MPF
7MPF
11MRF
(E)PJ
534.6
734.4
75.7
210.9
10.5
25.7
52.1
7.5
Item
Unitmass
Item
Unitmass
Item
Unitmass
Item
Unitmass
Item Unitmass Item Unitmass
Toothshapebelt(Standardconstruction) Vbelt
■Table1:ToothandVbeltlist
NOTE
Item BELTTYPE
EV5GTC
8YUF
EV8YUC
EV8YU2
EV5GTCarbon
8YUFluorine
EV8YUCarbon
EVⅡ8YU
Item BELTTYPE
8MGT
14MGT
EV14M2
3VXPB
Polychain8MGT
Polychain14MGT
EV
Ⅱ
14M
3VXPoweredband
Item BELTTYPE
5VXPB
5MPF
7MPF
11MPF
5VXPoweredband
Polyflex5M
Polyflex7M
Polyflex11M
Item BELTTYPE
*-K
*-S
Aramid(Kevlar)cord
Mectrolbelt
Steelcord
Mectrolbelt
(unit:g/mmwidthxmlength) (unit:g/mmwidthxmlength)unitmass:Masspermeterlengthofonerib(g/mlength)
XL-K
L-K
H-K
T5-K
T10-K
XL-S
L-S
H-S
T5-S
1.9
3.0
3.2
2.0
3.6
2.1
3.5
3.9
2.2
T10-S
AT10
AT20
5M-S
8M-S
14M-S
8YU-S
4.3
5.6
9.9
4.1
5.9
10.7
5.2
Mectrolbelt(Longlengthurethanebelt)
6-1.Howtoinputtheunit
mass(Refertotheunit
masstablesonnextpage)
●Tooth&Flattimingbelt
Toinputtheunitmassiswidth(mm)×
length(m)ing/mmwidth×mLength.
1.Datacapacityis000.1〜999.9g/mm
width×mLength
2.Abletoinputwithfoursignificant
digitfiguresofthreecolumnsof
integersanddecimalonecolumn
●Tooth &V beltfrom thepre-install
data
Push"MASS"bottommorethanone
second,belttypeshowsuponthe
screen.Withusing"UP"or"DOWN"
buttontoselectandpush"MEASURE"
toset.
●V,V-RibbedbeltandWire
Inputthemasspermeteroflengthin
"g/mlength"forunitmass.
Abletoinputbyfoursignificantdigits,
i.e.threedigitsofintegerandonedigit
belowdecimalpointfrom000.1upto
999.9g/mL.Unitmasscorresponds
toonepieceforV-beltandwire,and
oneribforV-ribbedbelt.
Note:UnitmassofU-508,U-507,and
U-505,U-305is10timestheinputof
conventionaltypeU-303sincetheinput
unithasbeenchanged.
Therefore,whenavalueisinputin
conventionalunitmass(g/cm2),
measuredtensionisdisplayedin1/10.
(Nochangeforthemeasuredfrequency
onthescreen)
6-2.Howtoinputthebelt
widthorthenumberof
belts(ribs)
●TimingorFlatbelt
Toputthedateisforbeltwidthis
000.1mm〜999.9mm,threedigitsof
integerandonedigitbelowdecimal
pointinmm.
●V,Vribbedbelt,Wire
ForVbeltandWire,putonepiece.
ForVribbedbelt,putthenumberof
ribsofV-ribbedbelt.
6-3.Howtoputthevalueof
spanlength
Spanlengthisadistancebetween
contactswithpulley,andcanbe
calculatedbytheffollowingcalculating
formula.
Alternatively,measurethedistance
betweenpulleycontactswithatape
measureandput.
S:Spanlength (
mm
)
C:Distancebetweenaxes (
mm
)
Dp:
Largepulleypitchouterdiameter
(
mm
)
dp:
Smallpulleypitchouterdiameter
(
mm
)
S= C − (Dp−dp)
4
22
Flattiming
belt
V-Ribbedbelt
Vbelt
Wire
g/mmW×mL
g/Ribbed×mL
g/onebelt×mL
g/onebelt×mL
mm
mm
mm
mm
mm
Numberof
Ribbed
1
1
MASS WIDTH SPAN
Item Unitmass Item Unitmass
6.Howtoinputthedata

9
10
1
2
3
●Listoftimingbeltunitmassspecifiedasstandardconfiguration
Timingbelt
HTDbelt
GTbelt
4PolychainGTcarbonbelt
5Unittamectrolbelt
6Specialpitchbelt
Toothshape
Pitch(mm)
MXL
2.032
1.2
XXL(50)
3.175
1.4
XL
5.080
2.1
DXL
5.080
1.9
L
9.525
3.1
DL
9.525
3.3
H
12.700
3.8
DH
12.700
4.4
XH
22.225
11.1
XXH
31.750
14.8
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
Toothshape
Pitch(mm)
Unitmass
(g/mmwidth×mlength)
3M-HTD
3.000
2.4
D3M-HTD
3.000
2.3
5M-HTD
5.000
3.8
D5M-HTD
5.000
4.2
8M-HTD
8.000
6.1
D8M-HTD
8.000
6.3
EV14M
14.000
8.7
EV14M2
14.000
8.3
14M-HTD
14.000
10.0
D14M-HTD
14.000
11.9
20M-HTD
20.000
12.8
8M-GT
8.000
4.7
14M-GT
14.000
8.0
2.0 2.2 3.6 4.3 5.6 9.9 1.9 2.1 3.0 3.5 3.2 3.9 4.1 5.9 5.2 10.7
K S K S S S K S K S K S S S S S
5.000 10.000
10.000 20.000
5.080 9.525 12.700
5.000 8.000 8.000 14.000
T5 T10
AT10 AT20
XL L H 5M 8M 8YU 14M
Toothshape
Pitch(mm)
Unitmass(g/mmwidth×mlength)
Cord
101
1.5875
1.0
102
2.0320
1.3
103
2.1167
1.3
104
2.8222
1.0
111
1.4111
1.1
109
2.1167
1.1
181
2.8222
0.9
25
6.3500
1.7
9109
15.4473
3.0
1.5GT
1.500
0.9
2GT
2.000
1.3
3GT
3.000
2.5
D3GT
3.000
2.5
5GT
5.000
4.0
D5GT
5.000
4.3
EV5GTC
5.000
3.8
EV5GT
5.000
4.0
EV8YU
EV8YUC
EV8YU2
8.000
5.1
8YU
8.000
5.2
8YUF
8.000
6.1
D8YU
8.000
5.4
Refertotheexplanationof"MASS"buttonatpage5and6. Asforthespecialpitchor
thebelt,pleaserefertheunitmasstableonthenextpageandinputcorrectly.
7.
Unitmasstableofthepreinstalledbelt
■Table2:ForU-508,507andU-505,305unitmasstable
Dataofunitmasscanbeinputbyfoursignificantdigits,i.e.threedigitsofintegerand
onedigitbelowdecimalpointing/mmWxmLfrom0.1to999.9g/mmWxmL.
8.
UnitmasstableofGateUnittaAsiatoothshapetimingbelt
Note:Inputwithavalue10timesaslargeasaunitmasslisted(g/cm)usedinU-303(outofsalesmodel).
1.5GT
2GT
3GT
D3GT
5GT
EV5GT
EV5GTC
D5GT
8YU
0.9
1.3
2.5
2.5
4.0
4.0
3.8
4.3
5.2
8YUF
EV8YU
EV8YUC
EV8YU2
D8YU
8MGT
14MGT
EV14M
EV14M2
6.1
5.1
5.1
5.1
5.4
4.7
8.0
8.7
8.3
3M
D3M
5M
D5M
8M
D8M
14M
D14M
20M
2.4
2.3
3.8
4.2
6.1
6.3
10.0
11.9
12.8
MXL
XL
DXL
L
DL
H
DH
XH
XXH
1.2
2.1
1.9
3.1
3.3
3.8
4.4
11.1
14.8
3VX
5VX
8VX
J(V)
PK(V)
L(V)
A(V)
B(V)
C(V)
59.8
165.6
525.6
8.6
20.0
30.4
103.2
166.0
298.8
D(V)
E(V)
3VXPB
5VXPB
5MPF
7MPF
11MRF
(E)PJ
534.6
734.4
75.7
210.9
10.5
25.7
52.1
7.5
Item
Unitmass
Item
Unitmass
Item
Unitmass
Item
Unitmass
Item Unitmass Item Unitmass
Toothshapebelt(Standardconstruction) Vbelt
■Table1:ToothandVbeltlist
NOTE
Item BELTTYPE
EV5GTC
8YUF
EV8YUC
EV8YU2
EV5GTCarbon
8YUFluorine
EV8YUCarbon
EVⅡ8YU
Item BELTTYPE
8MGT
14MGT
EV14M2
3VXPB
Polychain8MGT
Polychain14MGT
EV
Ⅱ
14M
3VXPoweredband
Item BELTTYPE
5VXPB
5MPF
7MPF
11MPF
5VXPoweredband
Polyflex5M
Polyflex7M
Polyflex11M
Item BELTTYPE
*-K
*-S
Aramid(Kevlar)cord
Mectrolbelt
Steelcord
Mectrolbelt
(unit:g/mmwidthxmlength) (unit:g/mmwidthxmlength)unitmass:Masspermeterlengthofonerib(g/mlength)
XL-K
L-K
H-K
T5-K
T10-K
XL-S
L-S
H-S
T5-S
1.9
3.0
3.2
2.0
3.6
2.1
3.5
3.9
2.2
T10-S
AT10
AT20
5M-S
8M-S
14M-S
8YU-S
4.3
5.6
9.9
4.1
5.9
10.7
5.2
Mectrolbelt(Longlengthurethanebelt)
6-1.Howtoinputtheunit
mass(Refertotheunit
masstablesonnextpage)
●Tooth&Flattimingbelt
Toinputtheunitmassiswidth(mm)×
length(m)ing/mmwidth×mLength.
1.Datacapacityis000.1〜999.9g/mm
width×mLength
2.Abletoinputwithfoursignificant
digitfiguresofthreecolumnsof
integersanddecimalonecolumn
●Tooth &V beltfrom thepre-install
data
Push"MASS"bottommorethanone
second,belttypeshowsuponthe
screen.Withusing"UP"or"DOWN"
buttontoselectandpush"MEASURE"
toset.
●V,V-RibbedbeltandWire
Inputthemasspermeteroflengthin
"g/mlength"forunitmass.
Abletoinputbyfoursignificantdigits,
i.e.threedigitsofintegerandonedigit
belowdecimalpointfrom000.1upto
999.9g/mL.Unitmasscorresponds
toonepieceforV-beltandwire,and
oneribforV-ribbedbelt.
Note:UnitmassofU-508,U-507,and
U-505,U-305is10timestheinputof
conventionaltypeU-303sincetheinput
unithasbeenchanged.
Therefore,whenavalueisinputin
conventionalunitmass(g/cm2),
measuredtensionisdisplayedin1/10.
(Nochangeforthemeasuredfrequency
onthescreen)
6-2.Howtoinputthebelt
widthorthenumberof
belts(ribs)
●TimingorFlatbelt
Toputthedateisforbeltwidthis
000.1mm〜999.9mm,threedigitsof
integerandonedigitbelowdecimal
pointinmm.
●V,Vribbedbelt,Wire
ForVbeltandWire,putonepiece.
ForVribbedbelt,putthenumberof
ribsofV-ribbedbelt.
6-3.Howtoputthevalueof
spanlength
Spanlengthisadistancebetween
contactswithpulley,andcanbe
calculatedbytheffollowingcalculating
formula.
Alternatively,measurethedistance
betweenpulleycontactswithatape
measureandput.
S:Spanlength (
mm
)
C:Distancebetweenaxes (
mm
)
Dp:
Largepulleypitchouterdiameter
(
mm
)
dp:
Smallpulleypitchouterdiameter
(
mm
)
S= C − (Dp−dp)
4
22
Flattiming
belt
V-Ribbedbelt
Vbelt
Wire
g/mmW×mL
g/Ribbed×mL
g/onebelt×mL
g/onebelt×mL
mm
mm
mm
mm
mm
Numberof
Ribbed
1
1
MASS WIDTH SPAN
Item Unitmass Item Unitmass
6.Howtoinputthedata

11
12
3PollychainGTCarbonBelt
※Contactusabout20Mtype.
10 .
ThestandardinstallationtensiontableoftheGUAtimingbelt
1TimingBelt
2GT&HTDBelt
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Tooth
Shape
1.5GT
1.5 2.0 2.5 3.0 4.0 6.0
3.4 4.4 5.6 7.8 12.6 19.6
9.0 12 15 20 25 30 40 50 55 60 70 85 100 115 130
2GT
EV5GT
4.3 5.2 6.4 9.4 15.8 25.2 34.6 44.1
3GT・3M 29 44 59 74 98
5GT・5M 55 75.9 96
210 285 350
137 178 220 302
8YU・8M
17871 98 125 232 286 393
14M
410 600 836.7 920 1100
EV14M
150 170
8MGT
14MGT
MIN
MAX
MIN
MAX
320240190 340 400 480 580 640 800 970 1000 1130 1290
430330260 460 540 650 780 870 1080 1300 1340 1520 1730
15201230820 1640 2050 2460 2790 2870 3280 3690 4100 4720 5130
205016701100 2220 2780 3330 3770 3890 4440 5000 5550 6380 6940
5330
7220
201512 21 25 30 36 40 50 62 7060 80
373020 40 50 60 68 70 80 100 11590 125 130
Width
(
mm
)
Width2(shapetype)
Tooth
Shape
MXL
3.2 4.8 6.4
(25) (31) (37) (50) (75) (100)(150)(200)(300)(400)(500)
7.9 9.5
2.9
5.1 7.6 10.3 11.8 16.4
XL
L
H
XH
XXH
13.7 19.6 24.5 34.5 55.0 75.1
52.0 87.3 123.0 271.6198.8
222 312 668486
909 20201430
1120 24801750 3190
12.7 19.1 25.4 38.1 50.8 101.6
10301050
76.2 127.0
1300
560 740 1100 1200 1400 380034002900250021001800
441 618
963.5
775 902 1000 1190 209017901470
EV8YU
235 294 343 500 765701 892 1100637
760
20
2.3
Unit(N)
Unit(N)
4UnittaMectrolBelt
T5
10 15 20 25 30 40
29 39 49 59 19698
50 55 60 80 85 100
T10
AT20
129 173 216 259 863431
AT5 773376
AT10 637183 235 294 343
637 637 1020 1275235 294 343
1301
637235 343
618 902 1470 1792
1301
5M
775 1792
14M
8YU
8M
220
20
60 99 137
376220
60 137
178
Unit(N)
XL
12.7 19.1 25.4 50.8 101.6
(050)(075)(100)(200)(400)
172 229 457 914
L248165 330 660 1321
296 394 787 1575
H
114
Unit(N)
Unit(N)
[M(g/mlength)=Masspermeterlengthofonerib(g/mlength)xTensioncorrectionfactor]
1SuperHCtype
2Polyflextype
3MicroVtype
4StandardVtype
Inputitem
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
3VXSingle
68.0×0.88=59.8
3VXPowerband
87.0×0.87=75.7
5VXSingle
182.0×0.91=165.6
5VXPowerband
237.0×0.89=210.9
8VSingle
657.0×0.8=525.6
Inputitem
5M
11.0×0.95=10.5
7M
27.0×0.95=25.7
11M
56.0×0.93=52.1
Inputitem
Jsection
9.0×0.95=8.6
Lsection
32.0×0.95=30.4
PKsection
21.0×0.95=20.0
Inputitem
A
120.0×0.86=103.2
B
200.0×0.83=166.0
C
360.0×0.83=298.8
D
660.0×0.81=534.6
E
1020.0×0.72=734.4
TheVbelthashighcomparativerigidity,thegapofrevisionisnecessaryforthe
actualandmeasuredtensionvalueintherangeofthestandardinstallationtension.
Therefore,itshouldbeadoptedasWEIGHTlevelwhichiscalculatedbythefollowing;
9.
TheunitmasstableofVbeltmadebyGates
■Table3:SpecializedunitmasstableforU508,507,505,503
※ContactusforunitmassoftoothedbeltforautomobileengineandV-ribbedbeltfor
drivingautomobileengineauxiliaryequipment.
Note:InquiretousfortheunitmassofV-ribbedbeltandtoothbeltforautomobileengines
withandautomobileenginesupplementaryplanedrive.
Width
(
mm
)
Width2(shapetype)

11
12
3PollychainGTCarbonBelt
※Contactusabout20Mtype.
10 .
ThestandardinstallationtensiontableoftheGUAtimingbelt
1TimingBelt
2GT&HTDBelt
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Width
(
mm
)
Tooth
Shape
Tooth
Shape
1.5GT
1.5 2.0 2.5 3.0 4.0 6.0
3.4 4.4 5.6 7.8 12.6 19.6
9.0 12 15 20 25 30 40 50 55 60 70 85 100 115 130
2GT
EV5GT
4.3 5.2 6.4 9.4 15.8 25.2 34.6 44.1
3GT・3M 29 44 59 74 98
5GT・5M 55 75.9 96
210 285 350
137 178 220 302
8YU・8M
17871 98 125 232 286 393
14M
410 600 836.7 920 1100
EV14M
150 170
8MGT
14MGT
MIN
MAX
MIN
MAX
320240190 340 400 480 580 640 800 970 1000 1130 1290
430330260 460 540 650 780 870 1080 1300 1340 1520 1730
15201230820 1640 2050 2460 2790 2870 3280 3690 4100 4720 5130
205016701100 2220 2780 3330 3770 3890 4440 5000 5550 6380 6940
5330
7220
201512 21 25 30 36 40 50 62 7060 80
373020 40 50 60 68 70 80 100 11590 125 130
Width
(
mm
)
Width2(shapetype)
Tooth
Shape
MXL
3.2 4.8 6.4
(25) (31) (37) (50) (75) (100)(150)(200)(300)(400)(500)
7.9 9.5
2.9
5.1 7.6 10.3 11.8 16.4
XL
L
H
XH
XXH
13.7 19.6 24.5 34.5 55.0 75.1
52.0 87.3 123.0 271.6198.8
222 312 668486
909 20201430
1120 24801750 3190
12.7 19.1 25.4 38.1 50.8 101.6
10301050
76.2 127.0
1300
560 740 1100 1200 1400 380034002900250021001800
441 618
963.5
775 902 1000 1190 209017901470
EV8YU
235 294 343 500 765701 892 1100637
760
20
2.3
Unit(N)
Unit(N)
4UnittaMectrolBelt
T5
10 15 20 25 30 40
29 39 49 59 19698
50 55 60 80 85 100
T10
AT20
129 173 216 259 863431
AT5 773376
AT10 637183 235 294 343
637 637 1020 1275235 294 343
1301
637235 343
618 902 1470 1792
1301
5M
775 1792
14M
8YU
8M
220
20
60 99 137
376220
60 137
178
Unit(N)
XL
12.7 19.1 25.4 50.8 101.6
(050)(075)(100)(200)(400)
172 229 457 914
L248165 330 660 1321
296 394 787 1575
H
114
Unit(N)
Unit(N)
[M(g/mlength)=Masspermeterlengthofonerib(g/mlength)xTensioncorrectionfactor]
1SuperHCtype
2Polyflextype
3MicroVtype
4StandardVtype
Inputitem
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
WEIGHT
(Massxcompensation)
coefficient
per1rib1mlength
3VXSingle
68.0×0.88=59.8
3VXPowerband
87.0×0.87=75.7
5VXSingle
182.0×0.91=165.6
5VXPowerband
237.0×0.89=210.9
8VSingle
657.0×0.8=525.6
Inputitem
5M
11.0×0.95=10.5
7M
27.0×0.95=25.7
11M
56.0×0.93=52.1
Inputitem
Jsection
9.0×0.95=8.6
Lsection
32.0×0.95=30.4
PKsection
21.0×0.95=20.0
Inputitem
A
120.0×0.86=103.2
B
200.0×0.83=166.0
C
360.0×0.83=298.8
D
660.0×0.81=534.6
E
1020.0×0.72=734.4
TheVbelthashighcomparativerigidity,thegapofrevisionisnecessaryforthe
actualandmeasuredtensionvalueintherangeofthestandardinstallationtension.
Therefore,itshouldbeadoptedasWEIGHTlevelwhichiscalculatedbythefollowing;
9.
TheunitmasstableofVbeltmadebyGates
■Table3:SpecializedunitmasstableforU508,507,505,503
※ContactusforunitmassoftoothedbeltforautomobileengineandV-ribbedbeltfor
drivingautomobileengineauxiliaryequipment.
Note:InquiretousfortheunitmassofV-ribbedbeltandtoothbeltforautomobileengines
withandautomobileenginesupplementaryplanedrive.
Width
(
mm
)
Width2(shapetype)

13
14
Thankyouforchoosingoursonictensionmeter(U-508).
Weguaranteeforoneyearforthemainbodyandsixmonthsforthesensor.
Ifoursonictensionmeter(U-508)failsduetoamanufacturingorworkmanshipdefect
duringtheperiod,werepairitfreeofcharge.
Pleasecontactourdistributorfromwhichyoupurchasedfortherepair.(Seethe
enclosedwarranty.)
Whentheofficialapprovalisrequired,directthesensortoacommunicator
whichemitsstablefrequencysoundfrom10to5000Hz,andmeasurethesamewayas
measuringtension.Thecalibrationisenabledeasily.
Tensionmeterofficialapprovaldevice(U-305-OS1)isalsointhemarket.
Ifneeded,pleasecontactoursalesdepartmentforpaidofficialapproval.
12.Guarantee&RepairGuidelines
Abouttheinstallationtensionlevelofourtoothbelt,thegapwillnotoccurbetweenU-508measurementandtruetensionintherangeofNote1
andNote3.Soitisnotnecessarytosetatensioncompensatingrate.
Note1)Asforthemeasuringinstallationtension,setthebeltonthemachinefirstandmeasuretheaveragetensionofstretchandlooseside
ofthebeltafterspinningseveraltimestomakethemachinerunsmoothly.Ifbothspanshavethedifferenceofmorethan30%,please
adjustthemandmeasureagain.
Note2)Measurewithaspanhavingthelengthmorethan20timesthetoothpitch.
(Becauseahighervaluethanactualisshowedattheshortrangetobeaffectedbytherigidityofthebeltitself.)
Note3)Setthetensionrangemorethan1/3ofstandardinstallationtension.
(Becauseahighervaluethanactualisshowedatthelowtensiontobeaffectedbyrigidityofbeltitself.)
Alsobythemeasuringmethodofourtensionmeter,measurementinanextremelylowtensionrangeissometimesimpossible.
Note4)
Asforthespecialbeltlikeawideandback-ribbedbeltonitsbackforconveying,thegapbetweenthetruetensionvalueispresumed,
sothatsimplecalibrationisrequiredforcheckingtensionwhichneedscomparativeprecision.
Asforexperiencedmachinesinstallthebeltfollowingtheprocedureprovidedforacorrespondingmachine,itiscapableofmanagingtension
bysettingcyclenumericalvaluewhichapprovedbyU-508afterward.
■MainBody
■Accessories
●U-508
●Option
●PowerSupply:TwotripleAbatteries.Alkaline
batteryisrecommended.
●OverallSize:160(H)×59(W)×26(26)
●Mass:120g
●Temperatureandhumidityrangeforuseand
storage:-10〜-50℃,80%
(freefromcondensation)
11.SpecificationofU-508
1)Flexibletypesensor
・Sensorouterdiameter:12.5mm
・Totallength:170mm
・Measurablefrequencyband:10Hz〜5000Hz
2)Softcaseforcarrying
・
Capableofcontainingthebodyoftensionmeter,
flexibletypesensoretc.
・
Totallength:170mm
・
Measurablefrequencyband:10Hz〜5000Hz
3)TwotripleAbatteries
4)OperationmanualofU-508
5)Operatingproceduresheetforcarrying
6)Inspectionacceptancecertificate
7)Warranty
8)TwoUSBconnectingcaps(oneisforaspare)
9)Operatingmanualofapplicationsoftwarefor
U-508
※PleaseusetheMINI-B5asUSBconnector
1)Flatflexiblesensor
・Sensorouterdiameter:Thickness10mm,
Width20mm
・Totallength:170mm
・Measurablefrequencyband:10Hz〜5000Hz
2)Longarmsensor
・Sensorouterdiameter:12.5mm
・Totallength:350mm
・Measurablefrequencyband:10Hz〜5000Hz
3)Electromagneticsensor
・Totallength:1m
・
Measurablefrequencyband:10Hz〜5000Hz
4)Cordtypesensor
・Sensorouterdiameter:12.5mm
・Totallength:1m
・
Measurablefrequencyband:10Hz〜5000Hz

13
14
Thankyouforchoosingoursonictensionmeter(U-508).
Weguaranteeforoneyearforthemainbodyandsixmonthsforthesensor.
Ifoursonictensionmeter(U-508)failsduetoamanufacturingorworkmanshipdefect
duringtheperiod,werepairitfreeofcharge.
Pleasecontactourdistributorfromwhichyoupurchasedfortherepair.(Seethe
enclosedwarranty.)
Whentheofficialapprovalisrequired,directthesensortoacommunicator
whichemitsstablefrequencysoundfrom10to5000Hz,andmeasurethesamewayas
measuringtension.Thecalibrationisenabledeasily.
Tensionmeterofficialapprovaldevice(U-305-OS1)isalsointhemarket.
Ifneeded,pleasecontactoursalesdepartmentforpaidofficialapproval.
12.Guarantee&RepairGuidelines
Abouttheinstallationtensionlevelofourtoothbelt,thegapwillnotoccurbetweenU-508measurementandtruetensionintherangeofNote1
andNote3.Soitisnotnecessarytosetatensioncompensatingrate.
Note1)Asforthemeasuringinstallationtension,setthebeltonthemachinefirstandmeasuretheaveragetensionofstretchandlooseside
ofthebeltafterspinningseveraltimestomakethemachinerunsmoothly.Ifbothspanshavethedifferenceofmorethan30%,please
adjustthemandmeasureagain.
Note2)Measurewithaspanhavingthelengthmorethan20timesthetoothpitch.
(Becauseahighervaluethanactualisshowedattheshortrangetobeaffectedbytherigidityofthebeltitself.)
Note3)Setthetensionrangemorethan1/3ofstandardinstallationtension.
(Becauseahighervaluethanactualisshowedatthelowtensiontobeaffectedbyrigidityofbeltitself.)
Alsobythemeasuringmethodofourtensionmeter,measurementinanextremelylowtensionrangeissometimesimpossible.
Note4)
Asforthespecialbeltlikeawideandback-ribbedbeltonitsbackforconveying,thegapbetweenthetruetensionvalueispresumed,
sothatsimplecalibrationisrequiredforcheckingtensionwhichneedscomparativeprecision.
Asforexperiencedmachinesinstallthebeltfollowingtheprocedureprovidedforacorrespondingmachine,itiscapableofmanagingtension
bysettingcyclenumericalvaluewhichapprovedbyU-508afterward.
■MainBody
■Accessories
●U-508
●Option
●PowerSupply:TwotripleAbatteries.Alkaline
batteryisrecommended.
●OverallSize:160(H)×59(W)×26(26)
●Mass:120g
●Temperatureandhumidityrangeforuseand
storage:-10〜-50℃,80%
(freefromcondensation)
11.SpecificationofU-508
1)Flexibletypesensor
・Sensorouterdiameter:12.5mm
・Totallength:170mm
・Measurablefrequencyband:10Hz〜5000Hz
2)Softcaseforcarrying
・
Capableofcontainingthebodyoftensionmeter,
flexibletypesensoretc.
・
Totallength:170mm
・
Measurablefrequencyband:10Hz〜5000Hz
3)TwotripleAbatteries
4)OperationmanualofU-508
5)Operatingproceduresheetforcarrying
6)Inspectionacceptancecertificate
7)Warranty
8)TwoUSBconnectingcaps(oneisforaspare)
9)Operatingmanualofapplicationsoftwarefor
U-508
※PleaseusetheMINI-B5asUSBconnector
1)Flatflexiblesensor
・Sensorouterdiameter:Thickness10mm,
Width20mm
・Totallength:170mm
・Measurablefrequencyband:10Hz〜5000Hz
2)Longarmsensor
・Sensorouterdiameter:12.5mm
・Totallength:350mm
・Measurablefrequencyband:10Hz〜5000Hz
3)Electromagneticsensor
・Totallength:1m
・
Measurablefrequencyband:10Hz〜5000Hz
4)Cordtypesensor
・Sensorouterdiameter:12.5mm
・Totallength:1m
・
Measurablefrequencyband:10Hz〜5000Hz

SonicBeltTensionMeter
U-508OperationManual
Contents
1.Precautions P1
P3
P4
P5
P7
P8
2.Briefsummary,caution&check
pointsforthefailure
3.MeasurementprincipleofU-508
4.ExplanationofthepartsofU-508
mainbody
5.OperationprocedureofU-508
6.Howtoinputthedata
6-1Howtoinputtheunitmass
7.Unitmasstableofthe
preinstalledbelt
6-2Howtoinputthebeltwidthorthenumberofbelts(ribs)
6-3Howtoinputthevalueofspanlength
8.UnitmasstableofGateUnitta
Asiatoothshapetimingbelt
9.TheunitmasstableofVbelt
madebyGates
10.Thestandardinstallationtension
tableoftheGUAtimingbelt
P9
P 10
11.SpecificationofU-508
12.Guarantee&RepairGuidelines
P 12
P11
P10
P 13
ThismanualdescribesoperationprocedureofU-508.
Pleasereadthismanualthoroughlybeforeforfulluseoffunctions.
U-508MANUALV01
HEADOFFICE4-26SAKURAGAWA4-CHOME,NANIWA-KUOSAKA556-0022.JAPAN
TEL:06-6563-1284 FAX:06-6563-1285
Table of contents
Popular Measuring Instrument manuals by other brands

Grundfos
Grundfos SI 010 CNV Installation and operating instructions

WAGNER
WAGNER TITANUS SUPER-SENS Technical manual

Hanna Instruments
Hanna Instruments HI 99191 instruction manual

Kusam-meco
Kusam-meco KM 061 Operation manual

Interacoustics
Interacoustics MT10 Instructions for use

Shinko
Shinko CLT-200 instruction manual