manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. uRADMonitor
  6. •
  7. Measuring Instrument
  8. •
  9. uRADMonitor SMOGGIE User manual

uRADMonitor SMOGGIE User manual

This manual suits for next models

4

Other uRADMonitor Measuring Instrument manuals

uRADMonitor D User manual

uRADMonitor

uRADMonitor D User manual

uRADMonitor A3 User manual

uRADMonitor

uRADMonitor A3 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Connecting and starting your SMOGGIE
Connect the uRADMonitor to the power source using the 5V micro USB adapter and cable. Use a
smartphone or a computer with WLAN capabilities to connect to the local hotspot spawned by your
SMOGGIE unit. The SSID is uRADMonitor-XX, where XX are the last two digits of the Device ID
number. The key is the Device ID, in uppercase, as printed on the enclosure. You can later change this
key. Open 192.168.4.1 in your browser:
Click the "CONFIG" link to setup the connection to the Internet. A new page opens where you can see
all your nearby WiFi networks.
Select your Internet access point from the list and enter the key to connect your SMOGGIE to the
INTERNET. Press SAVE. Here you can also change the default key on your SMOGGIE.
USB Configuration
Alternatively, the SSID and KEY can also be configured via USB. Connect to your SMOGGIE via USB,
baudrate 9600bps, open a terminal program and type the two commands: "key1","SSID" then
"key2","your WLAN key" . Use the "getsettings" command to verify that the new settings are in place.
Quotes are a must, and there are no spaces in between. See the USB Commands manual for more.
Open source
SMOGGIE uses Arduino. The source code was designed as open source, so you can customize it
yourself. You can program your unit via the USB cable. See https://github.com/radhoo/
uradmonitor_smoggie
Data Access
There are three easy ways to access the data generated by your detector:
1. local access, simply open the LAN IP of your unit in your browser, to access an embedded mini
webserver, where you can see the measurements or access the data as a JSON formatted file.
2. on the uRADMonitor portal frontend, open http://www.uradmonitor.com/?open=ID , where ID is
your unit's ID (16XXXXXX), please replace accordingly. This will open the global map to your unit's
location and you can see the data represented in charts.
3. using the uRADMonitor cloud API, via REST API calls, please see the details presented in the
uRADMonitor Dashboard on http://www.uradmonitor.com/dashboard
uRADMonitor SMOGGIE Quickstart Guide
Congratulations on purchasing this excellent low cost environmental monitor! You are now part of an
ambitious global project. The uRADMonitor is a global array of interconnected monitoring stations,
focused on continuous Environmental Surveillance. Its purpose is to generate fully transparent open
data, to assert the quality of our environment, directly impacting our health.
uRADMonitor SMOGGIE is an automated, fixed monitoring station. There are 4 SMOGGIE flavors for
different applications. They all track temperature, pressure and humidity. Additional features include:
•SMOGGIE-PM25, tracks 5 parameters, adding Particulate Matter PM1, PM2.5 and PM10
•SMOGGIE-CO2, monitors 3 parameters, adding CO2 monitoring to T+H
•SMOGGIE-CH2O, monitors 3 parameters, adding Formaldehyde monitoring
•SMOGGIE-GAS, monitors 3 parameters, adding one electrochemical cell for one of the
following: Ozone, Nitrogen Dioxide, Sulphur Dioxide, Carbon Monoxide, Ammonia, Hydrogen
Sulfide, Chlorine, Hydrogen, Hydrogen fluoride, Hydrochloric acid.
They all come in a compact, rugged plastic enclosure with wall mounting support. The data is exported
to the uRADMonitor network and can be accessed in real time using the cloud API interface or directly
via the local network. It supports Wifi connectivity to the INTERNET.
More on: http://www.uradmonitor.com/blog http://www.uradmonitor.com/forum