usi MIC1509S User manual

Page 16
C O N D I T I O N
New - Out of package.
AC power is present.
DC power is present.
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds
One or more alarms not
responding to
interconnected alarm.
ALARM AUDIBLE & VISUAL SIGNALS
HORN
Off
Silent
3 Beeps,
6 second
pause,
4 beeps.
Horn does
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
PWR
GREEN
LED
Off
Stays On
Stays On
Stays On
SMK RED
LED
Off
Blinks On
approx. every
2 minutes.
Blinks On in
sync with 3
beeps.
Blinks on
approx. every
2 minutes
CO RED
LED
Off
Off
Blinks On in
sync with 4
beeps.
Off
RECOMMENDATION
To activate the alarm remove the pull tab. The
alarm will sound one long beep to let you know
it is powered up.
Alarm is operating properly.
Alarm is powered
by battery backup.
AC power not present.
Silent Off Blinks On
approx. every
2 minutes.
Off Check the breaker or fuse box for power. If
the breaker or fuse box looks normal, call a
licensed electrician for assistance.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
Originating Smoke Alarm 3 Beeps, 2
second pause,
repeat
Stays On Blinks on in
sync with 3
beeps
Off If hazard is identied please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
The Test button has been
pressed. The test sequence
lasts for approx 10 seconds.
3 Beeps,
6 second
pause, 4
beeps.
Stays On Blinks On in
sync with 3
beeps.
Blinks On in
sync with 4
beeps.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately.
Originating Smoke Alarm 3 Beeps, 2
second pause,
repeat
Stays On Blinks on in
sync with 3
beeps
Off If hazard is identied please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
One or more alarms not
responding to
interconnected alarm.
Horn does
not sound
when other
alarms are
active or when
test button is
pressed on
interconnected
alarm
Stays On Blinks on
approx. every
2 minutes
Off Press and hold the smoke alarm Test button
for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box
and disconnect the alarm from the mounting
bracket and make sure the connector plug
is securely attached on alarms that did
not sound. If still no alarm, have licensed
electrician make sure the yellow wire is not
mistakenly or accidentally connected to the
white (neutral) wire. NOTE: In an intercon-
nected system containing a CO alarm, the
CO alarm will not respond to the smoke alarm
signal and the smoke alarm will not respond to
the CO alarm signal.
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034
QUICK REFERENCE GUIDE - Model MIC1509S
Page 17
C O N D I T I O N
Non-originating smoke
alarm. Another
interconnected smoke
alarm has sensed smoke
causing all interconnected
alarms to sound.
Non-originating CO alarm.
Another
interconnected CO
alarm has sensed CO
causing all interconnected
alarms to sound.
CO alarm when cause of alarm
is known and poses no threat
ALARM AUDIBLE & VISUAL SIGNALS
HORN
3 Beeps,
2 second
pause, repeat
4 Beeps,
5 second
pause, repeat
4 Beeps, 5
second pause,
repeat
PWR
GREEN
LED
Stays on
Stays on
Stays on
SMK RED
LED
Off
Blinks on
approx. every
2 minutes
Blinks on
approx. every
2 minutes
CO RED
LED
Off
Off
Blinks On in
sync with the
4 beeps
RECOMMENDATION
Another interconnected smoke alarm has
sensed smoke causing all interconnected
alarms to sound. If hazard is identied please
take all precautions if an alarm sounds by
calling Emergency Service and getting out
of the home.
Originating CO alarm 4 Beeps,
5 second
pause, repeat
Stays on Blinks on
approx. every
2 minutes
Blinks On in
sync with the
4 beeps
If hazard is identied please take all precau-
tions if an alarm sounds by calling an Emer-
gency Service and getting out of the home.
Nuisance alarm Horn sounds
when no hazard
present
Stays on Blinks On in
sync with the
3 beeps
Blinks On in
sync with the
4 beeps
If there is no hazard present verify the alarm
is mounted in the correct location (see user’s
manual). Reset alarm as instructed below.
Smoke alarm when cause
of alarm is known and poses
no threat
3 Beeps,
2 second
pause, repeat
Stays on Blinks On in
sync with the
3 beeps
Off The smoke alarm Silence Feature can be
activated by pressing and releasing the Silence
button on the initiating alarm while in alarm
condition. Silence mode will last for approx-
imately 8 - 12 minutes [With the red LED
blinking on approx every 10 seconds].
Alarm needing reset due to
abnormal operation/previous
alarms
Silent (alarmed
previously)
Stays on Blinks on
approx. every
2 minutes
Off To reset the alarm, hold the
Test button for 10-15 seconds.
This will clear alarm origination. Reset
after each alarm event.
Low Battery or Product End-of-
Service Life Warning
2 Chirps approx
every 60
seconds
Stays on Blinks on
approx. every
2 minutes
Off Deactivate alarm (See User’s Manual
“ALARM DEACTIVATION” section).
The warning cannot be silenced. Replace
alarm immediately.
Sensor Trouble Signal
RESET INSTRUCTIONS: Press the Test/Silence button for 10-15 seconds and then release. This will clear the alarm origination and latching LED.
Be sure to RESET alarms after every alarm event.
QUICK FIND® Alarm Origination/Location Feature: The QUICK FIND® feature will allow you to immediately locate the originating alarm (the alarm
that triggered the other alarms), once the alarms have stopped sounding.
1. Press and release the Test button on any alarm. After releasing the button, the test sequence on this alarm will begin, and last approximately
5-20 seconds.
2. Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to locate the
originating alarm.
3. Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation.
NOTE: If you have any additional questions about the operation of Model MIC1509S, please contact our Customer Service Department at
800-390-4321, and we will gladly assist you.
3 Chirps approx
every 60
seconds
Stays on Blinks on
approx. every
2 minutes
Off Reset the alarm. If this does not clear the
trouble signal, replace alarm immediately.
The sensor trouble signal cannot be silenced.
Previous alarm condition at
unidentied source
Silent (alarmed
previously)
Stays on Blinks on
approx. every
2 minutes
Off Quick Find® Alarm Origination - In an intercon-
nected system it is difcult to determine which
alarm initiated the alarms to sound. The Quick
Find® feature will allow you to immediately
locate the originating alarm (once the alarms
have stopped sounding). To initiate Quick
Find® press the Test button on any alarm.
After releasing the button and following the test
sequence, the originating alarm will continue
to sound for approximately 60 seconds. In a
non-interconnected installation, it is necessary
to test each alarm to determine the originating
alarm.
An interconnected CO alarm has sensed CO
causing all interconnected alarms to sound. If
hazard is identied please take all precautions
if an alarm sounds by calling Emergency
Service and getting out of the home.
The CO alarm Silence Feature can be
activated by pressing and releasing the Silence
button on the initiating alarm while in alarm
condition. The alarm will remain silent for ap-
prox 5 minutes [With the red LED blinking on
approx every 10 seconds], depending on the
level of CO detected. If CO levels drop below
alarm levels, the alarm will remain silent and
return to normal operation. If CO levels remain
constant or increase, this indicates a potentially
dangerous situation and the horn will sound
again. Ventilate area.
288-3564-01
QUICK REFERENCE GUIDE - Model MIC1509S
USI Electric, Inc.
1-800-390-4321
www.UsiElectric.com

Other manuals for MIC1509S

1

Other usi Fire Alarm manuals

usi UNIVERSAL 5304CN User manual

usi

usi UNIVERSAL 5304CN User manual

usi MP117 User manual

usi

usi MP117 User manual

Popular Fire Alarm manuals by other brands

Honeywell NOTIFIER ID61 operating manual

Honeywell

Honeywell NOTIFIER ID61 operating manual

Ramtech Electronics WES3 troubleshooting guide

Ramtech Electronics

Ramtech Electronics WES3 troubleshooting guide

SMS SenTRI Data and Installation Instructions

SMS

SMS SenTRI Data and Installation Instructions

Monaco C-99A Installation, operation, maitenance manual

Monaco

Monaco C-99A Installation, operation, maitenance manual

Fike FCP-300 Installation & operation manual

Fike

Fike FCP-300 Installation & operation manual

Polon-Alfa 4000 Operation and maintenance

Polon-Alfa

Polon-Alfa 4000 Operation and maintenance

Radionics D9024 installation instructions

Radionics

Radionics D9024 installation instructions

GST GST-MNA2C Installation and operation manual

GST

GST GST-MNA2C Installation and operation manual

Notifier RP-1001 installation manual

Notifier

Notifier RP-1001 installation manual

Vigilant MICROVAC owner's manual

Vigilant

Vigilant MICROVAC owner's manual

AES 7707 Installation, operation, and programming manual

AES

AES 7707 Installation, operation, and programming manual

Teknim TFP3304 manual

Teknim

Teknim TFP3304 manual

FireClass Prescient III Application, Installation & Commissioning

FireClass

FireClass Prescient III Application, Installation & Commissioning

Electro Detectors Zerio Plus EDA-C5000 installation manual

Electro Detectors

Electro Detectors Zerio Plus EDA-C5000 installation manual

Gent System 800 Installer manual

Gent

Gent System 800 Installer manual

Johnson Controls IFC-1010 Technical manual

Johnson Controls

Johnson Controls IFC-1010 Technical manual

Global Fire ORION 4 Installation, operation and maintenance manual

Global Fire

Global Fire ORION 4 Installation, operation and maintenance manual

Mircom RAM-300LCD Series Installation and operation manual

Mircom

Mircom RAM-300LCD Series Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.