UVPLUS UVP701C User manual

UVP701C
Professional Intelligent UV & Ozone Generator
24W UVC bulb 254nm UVC
Work light specifications
Irradiance:
2340μW/cm²
UVC gen: 120W
Ozone gen: 320W
Output
10.6 kg
IP20
60mg/m³
28ppm
UVC gen:
230x141x440mm
Ozone gen:
365x297x168mm

Schematic Diagram of Product:
UVC disinfection:
Ozone generator:
Color LCD screen
Handle
Connectingsocket
Connectingsocket
Handle
Handle
Housing
Chargingsocket
Switch on/off
Housing
Chargingsocket
Switch on/off
UVC tube
Product Features:
• Dual-effect disinfection combination, fully reflects the high efficiency of UV disinfection and ozone’s
no blind angle 360 degrees disinfection
• UVC disinfection lamp and Ozone generator can be combined or independently used.
• With the intelligent button operation interface, the user is able to independently select and adjust the
disinfection mode and disinfection time
• Color LCD screen can display the information e.g. disinfection mode, disinfection time etc..
• The disinfection cabinet has a memory function. After each power-on, the screen shows the preset
mode and time of the last disinfection operation
• During UVC disinfection, HBS intelligent Human Body Sensing system will start automatically, and it
will automatically stop the disinfection operation if it detects there are people moving around

A. Combined operation (operation process: UVC disinfection →Ozone disinfection →UVC decomposes
ozone)
1. Connect the power supply wire according to diagram 1.
2. Press the power switch “I” on the ozone generator then press the power switch “I” on the UVC disinfect
lamp.
3. Display three modes on the screen, from left to right they are: UVC disinfection (0~90minutes),
Ozone disinfection (0~240 minutes), UVC quickly resolve ozone (0~90minutes)
respectively (diagram 2). Short press the “OK” button to process mode shifting, short press “+” or “-”
to process the working time adjustment at corresponding modes.
4. Long press the “OK” button for 1.5s to start disinfect works after setting finished. The screenwill display
“ ” with flashing.
5. Under the UVC disinfection mode, HBS intelligent Human Body Sensing system startsautomatically, it
will automatically stop disinfection operation immediately if it detects thereare people moving around
the equipment, at the same time, the screen will show“ ” markto show that machine has
stopped due to close proximity of personnel
6. Long press “OK” button for 1.5s to stop the disinfection session, the timer will return to initialsetting.
B. Ozone generator standalone use
1. Connect the power supply wire according to diagram 3.
2. Press power switch “I” to turn on power supply, short press “+” or “-” to adjust disinfection duration.
3. After desired settings are selected, long press “OK” button for 1.5s to start 30s countdownpreparation
period, any personnel must leave the room where the equipment is located, after 30 seconds, the
equipment will automatically start.
4. Long press “OK” button for 1.5s to stop the disinfection session, the timer will return to initial setting.
Operation Instruction:
Diagram 1
Diagram 3 Diagram 4
Diagram 2

C. UVC disinfection lamp standalone use
1. Connect the power supply wire according to diagram 4.
2. Press power switch “II” to open power supply, intelligent Human Body Sensing system will start
automatically, then equipment will enter into prepareation period, any personnel must leave the room
where the equipment is located. It will automatically start disinfection operation immediately when
equipment does not detect any more people moving around the equipment.
3. The device will automatically stop disinfection operation immediately if it detects there are people
moving around the equipment to safely protect human body.
4. Please shut off the power supply switch after disinfect operation is finished.
SAFETY WARNING:
1. Please read and understand this user manual before use, to ensure that the product is safely and
properly used
2. Our Company shall not be liable for product damage and other injuries caused by improper use or failure
to follow this User Manual.
3. Strictly forbid any children 0-12 years old to use this product. Users should carefully select places
without children before use and ensure that children do not touch the product.
4. Avoid the risk of electric shock during use.
5. The use of this product in gas, flammable and explosive substances, and heat source environments is
prohibited.
6. Don’t use wet hands in operating the product. Please keep the operating environment dry
7. Do not remove, repair and alter the product by oneself. Repairs and battery replacements can only be
carried out by authorized service providers and manufacturers, and repair and replacement of batteries
by authorized service providers and personnel other than manufacturers may result in injury. Replacing
the battery with the wrong model is a risk of explosion
8. Use the product only at specified voltages and frequencies
9. UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision.
Never look at the bulbs while illuminated. Any exposed skin must not be exposed to UV light
CAUTION:
UVC-Equipment Damage Hazard.
1. Ultraviolet light can cause color shift or structural degradation of plastic materials
2. Ultraviolet light can cause color shift or structural degradation of resin materials
3. Ultraviolet light can cause color shift or structural degradation of leatherwear
4. Ultraviolet light can cause color shift or structural degradation of organic compounds materials
OZONE-Equipment Damage Hazard.
1. OZONE can cause color shift or structural degradation of plastic materials
2. OZONE can cause color shift or structural degradation of resin materials
3. OZONE can cause color shift or structural degradation of leatherwear
4. OZONE can cause color shift or structural degradation of organic compounds materials
5. High concentrations of ozone for a long time can cause electronic products function damage

NOTES:
1. The design of this product based on IEC 62471:2006 Photobiological safety of lamps and lamp
systems and other international standards
2. This product utilizes UVC bulbs to emit UV-C rays with peak value wave length at 254nm to disinfect
3. Ultraviolet tube is a relatively tight and fragile electronic component, users should avoid the impact on
the product resulting in product failure.
4. The design of this product is according to Code of Federal Regulations Title 21, Volume 8 by US FDA,
California Code of Regulations Title 17 Public Health, and IEC 62368-1[4] 7.3 and other international
standards
5. According to code of federal Regulations Title 21, Volume 8, ozone is a toxic gas, according to the FDA.
Although ozone has been reported to have adverse physiological effects on the central nervous
system, heart and vision, its main physiological effect is to stimulate the mucous membranes.
Inhalation of ozone causes enough irritation to the lungs, leading to pulmonary edema. The onset of
pulmonary edema is usually delayed by several hours after exposure; As the hazards of ozone are
widely understood, people pay full attention to the use of ozone.
6. At Ozone concentrations of 0.02PPM (0.04mg/m³), ozone can be smelled by people with acute
olfactory senses, at 0.15PPM (0.32mg/m³), ozone can be smelled by the general population, at
1-10PPM (2.14 - 21.4mg/m³) ozone has reached the "stimulus range", and can be clearly smelled, at
10PPM (21.4mg/m³) ozone has reached the "toxic range" or more "poisonous range". The odor of ozone
is not a reliable warning indicator due to the possibility of olfactory fatigue
7. Long term occupied enclosed spaces, such as houses, apartments, hospitals and offices, should have
ozone volumes below 0.1mg/m³ (0.05PPM). The ozone concentration in the workplace, i.e.
occupational exposure limit, is 0.1PPM
8. The amount of space used by the equipment used to place and use this device should not be less than
20m³ to ensure that the ozone remaining in the equipment has sufficient space to be decomposed to a
safe level when the cabinet door is opened
9. When opening the equipment for ozone disinfection, make sure that the equipment is in a well
ventilated environment. If the equipment cannot be ensured to be in a well-ventilated environment,
only open the cabinet door at least 30 minutes after an ozone disinfection session has finished
10. Ozone is unstable, breaks down rapidly at high temperatures, slowly breaks down to (oxygen) at room
temperature, has a half-life of about 16 minutes in 1% of ozone solution and about 25 minutes in the
air.
11. Pure ozone, if receives impact or friction, will explode and decompose. High concentrations of ozone
when heated is also prone to explosion. But as long as care is taken, such accidents are rather rare.
Ozone should not have high concentrations of flammable and explosive gases at the disinfection site
when it is used for air disinfection.
12. The user use 3M8514 welding protection mask (or equal grade protection masks) when use ozone to
disinfect, and can process ozone protection which at 10 times occupation touch limit potency under
1PPM
13. In order to ensure the safety of the user, this product has set up a full safety device. Daily spot checks
are necessary to ensure the safe use of equipment. Check as required by the specification and stop
using the device immediately if the problem is identified. In the use of ozone disinfection, or equipment
regular inspection, the use of 3M8514 welded protective mask (or similar grade protective mask), can
be 10 times the occupational contact limit concentration (1PPM) ozone protection. When repairing the
equipment, in addition to wearing the above protective mask, the equipment should be kept in a well

ventilated environment.
14. Because of the instability of ozone, ultraviolet light accelerates the decomposition of ozone and
converts it back to oxygen. After the ozone work is completed, the equipment switches to UV mode to
quickly reduce the ozone concentration in the equipment. The user must never open the cabinet doors
before the device has completed the ozone disinfection operation (before the end of the timer
countdown in the monitor)
15. Users are advised to equip users with ozone concentration detection instruments to regularly detect
whether the leaked ozone value of the equipment exceeds the safe value: long term populated
enclosed spaces, such as houses, apartments, hospitals and offices, ozone must be less than 0.1PPM
in English. If ozone leakage value is found to have exceeded the above standard, the equipment must
be immediately stopped.
To guarantee the disinfect effect of UVC:
1. Whether UV light can effective disinfect depends on the amount of exposure received by the
disinfection object, which depends on the radiation power of the UV light source, the distance of the
disinfection object from the UV light source, and the duration of the exposure to UV light.
2. When killing common microorganisms, the irradiated dose should reach 10,000
μ
W/cm²; 100,000
μ
W/cm² is the recommended dose to kill bacterial spores. The radiation dose should not be less than
100,000
μ
W/cm² when the target microorganism for disinfection is unknown
3. According to the radiation intensity of the UV light source of this product and the general distance of
the UV light source from the irradiated object, it is recommended that:
• In order to achieve the radiation dose of 10,000
μ
W/cm² to meet the general needs of daily use, the
exposure time should be at least above 5 seconds
• In order to achieve the radiation dose of 100,000
μ
W/cm² to meet the needs of the professional
environment, the exposure time should be at least above 50 seconds
To guarantee the ozone disinfect effect:
1. Ozone can kill bacterial reproductions, viruses, fungi, etc., and can destroy botulinum toxin. In order for
ozone to be effective as a disinfectant, its concentration must be much higher than that that can be
safely tolerated by humans and animals. Ozone has a powerful killing effect on microorganisms in the
air, and at the same time has the odor-removal characteristics, 30minutes of 20mg/m³ (9.35PPM)
concentration of ozone in a sealed environments can achieve disinfection effect. Ozone on the surface
of the items of the microorganism also has a killing effect, requiring 60mg/m³ (28.04PPM), relative
humidity of 70%, and exposure of 60 minutes to 120 minutes, to achieve disinfection effect.
2. If the equipment is stopped in the middle of the operation, the disinfection effect cannot be
guaranteed, a new disinfection session from the start will be necessary.

The reminding of damage about the disinfect objects:
1. The effects of ozone on a variety of substances vary considerably. Glass, stainless steel, butyl rubber,
silicone, polycarbonate, and ABS plastics are better at ozone resistance, but nylon, zinc,
glass-fibre-added plastics, and natural materials such as natural rubber and leather, are less resistant
to ozone.
2. In order to ensure the service life, this product is designed with ozone-resistant materials.
3. In order to examine the accelerated aging effect of ozone on substances, the substance was tested for
60 minutes at a time using ozone concentrations of 35PPM.
4. After 10 tests of six different leather material colors samples, the results show color fading and
hardening of the material, especially the brighter samples, whose fading was more pronounced
5. The same conditions were tested on stainless steel, aluminum, gold-plated PIN needles, silicone,
cotton pads, cotton and ABS plastics, and no significant decomposition was found
6. It is recommended to avoid ozone disinfection of brightly colored leather, silk and other items. Some
highly aged items, such as natural rubber, are also recommended to not undergo ozone disinfection.
Since ozone has an oxidative effect on most metals, users should not use ozone disinfection on
electronic products to avoid ozone damage to devices containing metal substances, such as circuit
boards in electronic products.
MERCURY NOTICE: This device contains mercury in the sealed ultraviolet bulb(s). Do not place your used
bulb(s) in the trash. Dispose of properly Broken Bulb Cleanup. Do not use a household vacuum. Sweep
debris into a plastic bag and dispose of properly Contact your local waste management authority for
instructions regarding recycling and the proper disposal of old bulb(s).
Equipment maintenance, please contact professional after-sales service stores or professionals.

V1/HJ
AEC Lighting Solutions Co., Ltd
Add.: 2548 Bao’an Highway, Jiading District, Shanghai 201801, China
Tel.: 400-083-8757
www.aeclight-reel.com
WARNING HARMFUL OZONE may be created by this product.
Follow installation and operating instructions.
WARNING UV-C emitted from this product.
Avoid eye and skin exposure to unshielded product.
Follow installation instructions and user manual.
www.uvpluss.com
Breakable Glass Hazard. Can cause personal injury. Be careful when inserting bulb(s) into
lamp base. Wear protective gloves when handling bulb(s).
OZONE can cause color shift or structural degradation of leatherwear.
High concentrations of ozone for a long time can cause electronic. products
function damaged.