Installation instructions
Glass ceramic hob Toptronic
Frameless, with facets
J005133-R02
5.11.15
3
Indications
• The worktop must be flat in order that it is sufficiently sealed against the ingress of liquids.
• A SMS 6/6 oven can be installed directly beneath a worktop with a depth of ≥30 mm. Exception: M-SL.
• An oven with a short mounting form 55-600, 60-600, 55-381 or 60-381 can be installed underneath provided a ventilation grille set
is used (see J40254 .
• For the base element, a standard niche width of 275 mm is recommended (norm SMS .
Installation
For wood worktops
1. Create the installation cut-out accurately.
2. Centre mounting rails Ain cut-out and fix in place with wood screws Bas shown in the drawing above.
3. All lugs Cmust be broken off before mounting the hob.
4. Where necessary establish the mains supply connection before inserting the appliance.
5. Lower the appliance into the installation cut-out symmetrically to level with the worktop and onto the catch spring elements.
The connection cable may not touch any hot parts of the tray beneath the cooking zones.
For stone worktops
For stone worktops, mounting rails Acan be adhered in position (for adhesive, see «Accessories» .
1. Clean and prime the surfaces of the stone and the mounting rails to which the adhesive is to be applied well. Allow to dry.
2. Apply the adhesive to the stone and smooth with a spatula. Apply a thin layer of activator to the adhered surface of the mounting
rails.
3. Centre the mounting rails and press down well. Observe the recommended bonding time for the adhesive used.
4. Where necessary establish the mains supply connection before inserting the appliance.
5. Lower the appliance into the installation cut-out symmetrically to level with the worktop and onto the catch spring elements.
The connection cable may not touch any hot parts of the tray beneath the cooking zones.
R10
≥ 30
289
514
8
490 ±1
≥ 50
≥ 50
600
270±1
A
≥40
24.5
B
C
39.5
from top of tray
Centring marks
left/right for
middle of cut-out
Adjusting brace set for
special installation cases
Cable length 1.7 m