Important - please read
27
Please read these instructions carefully before starting installation and keep for future
reference.
Remove all packaging and check the product for missing parts or damage before
starting installation.
Any alterations made to this product and ttings may infringe water regulations and
will invalidate the guarantee.
The installation must comply with all Local/National Water Supply Authority
Regulations/Byelaws and Building and Plumbing (UK:BS6700) Regulations.
We strongly recommend that you use a qualied and registered plumber.
Installer must comply with current regulations.
Please note if installing in an enclosed environment, access should be left for servicing
and maintenance. No costs relating to inadequate access can be accepted.
Maintenance - handset
To remove any build up of limestone
on the showerhead, just rub your
ngers lightly over the nozzles.
Operation
Moving the handle will
increase/decrease the
water temperature.
Push down on
this button to
override the set
temperature.
In the o position.
Turning the handle forward
will operate the handset, and
turning the handle backwards
will operate the xed head.
Care of the mixer
Our products are nished to the highest standard and due care needs to be taken to
ensure their looks are retained.
We recommend cleaning all products with a soft damp cloth ONLY and advise strongly
against the use of ALL cleaning products i.e. powders and liquids.
If the above instructions are not followed this will invalidate your guarantee in the
event of a problem occurring.
Maintenance
This thermostatic valve is tted with a double ltering facility. Filters are tted on the
water inlets and on the thermostatic cartridge.
Depending on the water quality, lters may become dirty, causing reduced ow and
inecient working of the valve.
Shut o the water supply to both inlets at the isolating valves.
Inlet Filters.
Undo both locking nuts at the back of the valve and remove. Remove the lter, rinse in
water to remove the dirt, and then soak them in vinegar or descaling agent.
Cartridge Filters
To clean the lters, you must rst remove the cartridge from the housing.
1. Remove the handle by pulling out the screw cover, remove the screw from inside
and pull o the handle.
2. Pull out the stop ring from the body (see page 6).
3. Unscrew the internal locking ring and pull out the cartridge.
4. Clean the lters by rinsing them in water to remove the dirt and soaking them in
vinegar or descaling agent.
5. Before reassembling the cartridge, clean its housing with a wet cloth and grease the
‘O’ rings on the cartridge.
6. Push the cartridge into the body, replace the locking ring and tighten, push in the
stop ring with the stop at the 12 o’clock position.
7. Make sure everything is tight and secure and turn on the water supply at the
isolating valves.
8. Now check the water temperature to ensure that it is re-calibrated to 38°C.
9. With the temperature override button at the front, push in the button and push the
handle onto the splines, being careful not to turn the splines of the valve.
10. Secure the handle.