Vector Fog VECTORFOG H500 User manual

1
INSTRUCTION MANUAL THERMAL FOGGER VECTORFOG H500/H500SF
Only fog for short periods at a me, when there is not much wind and moving away from the projeg smoke.
It’s ess to read the manufacturer’s instrucons of the chemical being used before you start applying, including
dilungo and safety prons.
Only experienced personnel should operate this equipment.
You must exercise cauon if fuel is spilt, in order to avoid the risk ore.
CAUTION MARKS
Please read this manual before using the equipment.
You must wear protecve equipment (face/breathing mask, protecve clothing, gloves,
etc.) when handling potenlly hazardous chemicals.
It is advisable to wear ear plugs to protect from the high noise produced by this machine
The interior of this machine heats up to extrem high temperatures. Do not add fuel or
chemicals during the operaon of the machine or when it is hot aer use.
Avoid fogging chemicals upwind.
High voltage can be dangerous. Do not turn on the machine when the spark plugs
electrode is exposed.
Experts in Fogging Technology™

2
SPECIFICATIONS
Model
H500/H500SF
Type
Vehicle Mounted
Engine Pulse Jet
Tank material & shape Stainless Steel / Rectangular
Tank Capacity
150 Litres
Droplet Size
10-30 Microns
Flow Rate
80 Litres Per Hour
Fuel
Petrol
Fuel Consumpon 4.5 Litres Per Hour
Resonator Angle (SF Model Only) 0-45° Angle (Adjustable upwards from horizontal posion)
Start
Autom start via remote control
Independent resonator start
Power from vehicle baery
Fuel Tank Capacity
10 Litres
Weight (net)
65 Kg
Dimensions 162x72x80 (cm)
Addonal Features
Tools Kit
Cleaning Kit
Basic spare parts Kit
Warrantee
1 year
Origin
South Korea
ACCESORIES
Basic spare parts Kit (1)
Tools Kit (1)
Inon Manual (1)
Remote Control (1)
Cleaning Kit (1)
BASIC CONCEPT OF THERMAL FOGGING

3
PRINCIPLES OF OPERATION
VectorFog™ Thermal Foggers are powered using the pulse jet principle. Pulse jet engines don’t have any moving
parts; instead they have a funnel shaped combuson chamber similar to a rocket engine which opens into a long
resonator or exhaust pipe. VectorFog thermal foggers have an auto start and operate through compressed air via a
compressor. When the auto start buon is pressed, the compressed air pressurizes the fuel tank, causing fuel toow
to the injector and then into the carbureor. Air/fuel mixture is then ignited by a spark plug in the carbureor. The
spark is created by an ignion coil which is powered by the vehicles baery. The ignon coil, baery and
compressor are all housed inside of the main body of the machine. Opg at its opmum performance,
combuon and injecon is repeated with a frequency of around 200-250 cycles per second. Once the machine
starts, the chemical tank also becomes pressurized by means of a non-return valve. A close valve and supply valve
are then opened to allow the ow of the chemical/oil soluon in to the resonator. At this stage the soluon is
heated up to around 1,400º C and dispersed into millions of ny droplets (around 10-30 microns in size) creng a
dense and visible smoke.
MAIN COMPONENTS
FIG. 1
1. Air supply tube to carbureor
2. Air compressor
3. Fuel solenoid valve
4. Fuel cap
5. Relay
6. Fuel tank
7. Air valve
8. Air oulow to chemical tank
9. Chemical inow from tank
10.Chemical tube
11.Electronic ow control
12.Chemicalow regulator

4
MAIN COMPONENTS (Cont…)
FIG. 2
1. Air tube to carbureor
2. Fuow control valve & Injector
3. Carbureor
4. Fuel filter
5. Spark plug
6. Fuel hose
7. 12V Power supply input
8. Remote control input
FIG .3
1. Rear access cover
2. Front access cover
3. Resonator shield
4. Chemical injector to resonator
5. Vehicle frame
6. Resonator

1. Carburettor
2. Fuel Injector
3. Air Injector Tube
4. Main Air Compressor Tube
5. Compressor
6. Safety Mesh
7. Resonator
8. Chemical Inlet
9. Close valve/Directional valve (SF model)
10. Chemical Supply valve
11. Security Cover
12. Handle/Manual Start Pump (optional)
13. O Button (choke)
14. Control Remoto
15. Cable
16. Cable de Corriente con Pinzas de Cocodrilo
17. Grapa
18. Conector (izquierda)
19. Conector (derecha)
20. Bujía
21. Filtro inyector de gasolina
22. Intercambio de Aire
23. Tubo a Presión
24. Repetidor
25.
5
CHECKLIST BEFORE STARTING THE UNIT
Fill the fuel tank
Fill the tank with undiluted petrol using a funnel. Fill the tank to a third of its capacity. When younishling the
tank, close the tank cap ghtly. Note: Please make sure you only add the prescribed amount of fuel.
Fill the chemical tank and connect to the thermal fogger
Pour the special fogging chemical mixture into the chemical tank. It is important not to add more chemical mixture
than it’s needed. Leaving remaining chemical in the tank r use, could aect the performance of the machine next
me you use it, as deposits may solidify in the system. When younishling the tank, close the tank cap ghtly.
Connect the power and remote control
Connect the 12V power lead (right) and remote control cable (le) as indicated in the picture below. Once plugged
in, connect the power lead directly to theery using the cigaree lighter plug. Red (Posive), Black (Negve).
Once connected, check that the green power light on the control remote is on. Note: Please make sure solution tank
switch on the remote control is turned to the“OFF” position before connecting the power
Fuel Intake (right resonator)
Fuel Intake (leresonator)

6
To turn on the machine
Making sure that the soluon switch on the remote control is on the “OFF” posion. Press the start buon (one
resonator at a me) and keep it pressed for 5 seconds you hear combuon (sounds like a small
explosion). It is necessary to keep the machine on for about 10 seconds to warm up before turning on the soluon
switch. TIP: If the machine fails to start , press the button “KNOCKING” so pressure in the fuel tank can be re-
established. Press the start button again and repeat the above procedureuntil it starts .
To start fogging
Once the machine has heated up for 10 seconds, ick the soluon switch to the ON posion. When you are ready to
start fogging, turn clockwise the Chemical Flow Regulator (FIG 1.12). Note: This valve also regulates the amount of
ow/chemical being used, by turning it leto right.
To turn o the machine
Flick the soluon switch to the OFF posion and press the STOP buon. Turn the Chemical Flow Regulator an-
clockwise to stop the ow of chemical. Tip: Aer use, keep the machine in operaon for 5 seconds to help get rid-o
any chemical mixture sl in the system.
MAINTENANCE
Cleaning the Chemical Tank and Pipes
Fill the chemical tank with 25% of clean water and turn on the unit. This will prevent corrosion and the accumulaon
of chemical deposits in the tank and pipes.
Spark Plug Maintenance
Remove the spark plug using a spanner or spark plug remover. Remove any carbon deposits between the electrode
and the earth seon with a wire brush. Make sure that there is a space of 3 to 5 mm between the electrode and the
earth.

7
Fuel injector Maintenance
Unscrew the fuel Injector situated on the back of the machine (FIG 2.4). Clean the injector with compressed air.
Maintaining the valve petal
Remove the top of the carbureor. Check the gasket and valve for any distorons or cracks. If it’s damaged, you will
need to replace this part. TIP: It’s important to assemble the parts of the carburettor in the order there where
disassembled. The distance between the petal valve and the valve plate o should be approximately1 mm.
INJECTOR
NJECTOR
FUEL
REGULATOR

8
TROUBLESHOOTING
If there is no ignition:
• Listen for any noises coming from the engine
If there is noise coming from the engine but there is no ignon, this could be because the engine has ooded (an
over-supply of fuel in the carbureor). To solve this problem, rst press the buon “KNOCKING” and then press the
“START” buon un you hear the machine ignite. Repeat this procedure several mes if it doesn’t start the
me.
• Check the spark plug
Remove the spark plug using a spanner or spark plug remover. Hold the plug by its pc cap and press the start
buon to check if there is a spark between the electrode and the earth. Also you should hear if there buzzing sound
from the ignon coil. Note: The ignition coil can be accessed through the “Rear access cover”
If there is no spark:
Clean any carbon deposits in between the electrode and earth with a wire brush.
Check that there is a distance of 3 to 5 mm between the electrode and earth.
Check that the vehicle’s baery is fully charged.
Check that the baery and ignon coil are working. If necessary, replace the baery or coil
Clean the contacts and check all the wires
Once these checks have been carried out, try starting the machine again.
• Check the fuel is being injected into the carbureor.
Examine the fuel hose connected to the fuow control valve and injector (FIG 2.2) is not blocked. If there is a lack
of fuel adjust fuel supply with the fuel regulator valve. Make sure the fuel tank is full before starng the machine.
Make sure the seal in the petrol caps are not damaged. Make sure the caps are rmly closed. Check the fuel injector
(FIG 2.4). Clean the injector with compressed air if blocked.
STEP 1
STEP 2

9
• Check the Petal Valve.
Remove the spark plug cap and unscrew the carburer. Examine the petal valve to see if it’s damaged. If it’s
damaged, replace petal valve. TIP: It’s important to assemble the parts of the carburettor in the order there where
disassembled. The distance between the petal valve and the valve plate o should be approximately 1 mm.
The machine is turned on, but the engine works intermittently or stops:
• Examine the fuel tank assembly to check for any leakages.
Aer pressing the start buon, cover the tank and connecons with soap to check for leaks. If bubbles are observed,
the gasket needs replacing on the fuel tank cap or the tank itself.
• Clean the resonator.
Remove carbon deposits in the heat tube inside de resonator with the wire brush provided. Use and forward and
backward moon.
The machine doesn’t fog or doesn’t fog enough:
• Check that the chemical regulator is opened. This is done by turning it anclockwise. Make sure that the Tank
Chemical Supply Valve is set to the open posion.
Chemical
Regulator
Tank Chemical
Supply Valve

10
• Unscrew the main chemical inlet nozzle from the resonator and clean it using compressed air to remove any
blockages.
• Check there is no leaks in the chemical tank. Blow compressed air backwards though the chemical tube from the
inlet nozzle to see if any bubbles appear. Replace leaking parts if necessary
Parts Assembly
01.Resonator & chemical Inlet nozzle
1. Ejecn pipe
2. Inner cooling pipe
3. Outer cooling pipe
4. Bracket
5. Safety net
6. Ejecn nipple plate
7. Ejecn buer spring
8. Ejecn nipple
9. Ejecn nipple tube
10. Straight nipple
11. Ball valve
12. Straight nipple
13. Chemical pipe
14. Bolt
15. Pro cover
16. Bolt
17. Flat washer
18. Nut

11
04. Carbureor
1. Venturi
2. Upper Gasket
3. Cone sha
4. Petrol valve board
5. Petrol valve
6. Petrol valve support
7. Spring washer
8. Bolt
9. Lower Gasket
10. Engine
11. Ejecn nozzle
12. Nozzle
13. Ring
14. Nut
15. Engine upper pipe
16. Plug
17. Plug cap
18. Metal grip
19. O-ring
20. Engine rear peg
21. Reducer
22. Run tee
23. Elbow
24. Explosion pipe
25. Air gasket
26. Washer
27. Air Gasket Bolt
28. Air elbow
29. Extension hose
30. Air gasket bolt
31. Air gasket washer
32. Air gasket nut
33. Air gasket nut
NETHERLANDS | SOUTH KOREA | USA
Other manuals for VECTORFOG H500
1
This manual suits for next models
1
Table of contents
Popular Portable Generator manuals by other brands

Vante
Vante 3120 instruction manual

Elettrotest
Elettrotest RPS/M/1K user manual

AVION
AVION VOYAGER VPS 26/20-O Operator's manual

Generac Power Systems
Generac Power Systems GP7500E GP SERIES specification

Briggs & Stratton
Briggs & Stratton 030607-02 Operator's manual

Generac Power Systems
Generac Power Systems GP7000E GP SERIES specification