VENT-AXIA LUMINAIR RANGE: FITTING AND WIRING INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
1. GENERAL
Unpack taking care to note the product model reference on the outside of the carton eg. LuminAir T. The
installation details apply to all fan/light units and controllers, but the wiring and functions vary. This kit consists of
the following parts:- 1 luminair vent light, 1 luminair bend, 1 luminair axial fan, 3 metres of flexible ducting, 2 duct
ties, 1 soffit grille, 1 lighting transformer, 1 fan transformer/controller & fixings pack. (H model also includes a
humidity controller).
2. SAFETY AND GUIDANCE NOTES
2.1. DO NOT install this product in areas where the following may be present or occur:
2.1.1. Excessive oil or a grease laden atmosphere.
2.1.2. Corrosive or flammable gases, liquids or vapours.
2.1.3. Ambient temperatures higher than 40°C or less than -5°C.
2.1.4. Possible obstructions which would hinder access or removal of the Fan.
2.2. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate
standards of your country and MUST be installed by a suitably qualified person.
2.3. The fan should be provided with a fused, isolator switch capable of disconnecting
all poles, having a contact separation of at least 3mm.
2.4. Ensure that the mains supply (voltage, frequency, and phase) complies with the fan’s
rating label.
2.5. When the fan is used to remove air from a room containing a fuel-burning appliance,
ensure that the air replacement is adequate for both the fan and the fuel-burning
appliance.
2.6. When the fan extracts air from a room containing an open flue of a gas or fuel burning
appliance, precautions must be taken to avoid the back-flow of gases into the room.
2.7. The fan should not be used where it is liable to be subjected to direct water spray.
2.8. The fan should be mounted at the highest point in the system to protect it from
condensation build up.
2.9. This fan should be vented to the outdoors.
2.10. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
2.11. Children should be supervised to ensure that they do not play with the appliance.
ONLY CONNECT TOGETHER THE PRODUCTS SUPPLIED FROM LUMINAIR RANGE AS
THE FAN IS SPECIALLY DESIGNED TO OPERATE AT 12V AC AND IS NOT COMPATIBLE
WITH OTHER VENT-AXIA CONTROLLERS. DO NOT CONNECT MORE THAN ONE FAN
UNIT TO THE FAN CONTROLLER.
WARNING: Ensure that the mains supply is disconnected before making any electrical
connections. All electrical connections should be made by a properly qualified electrician. The
siting and installation MUST comply with current IEE Regulations, BS7671 (U.K.) or the
appropriate standards in your country. All regulations and requirements MUST be strictly
followed to prevent hazard to life and property, both during and after installation, and while