Veria Control ET45 User manual

Veria Control T45
Installation guide EN

2
Table of content
Introduction 3
Button and display description 4
Installing and wiring the thermostat 5
Basic functionality
- Select how to control your
oor heating system 6
- Recommended settings 7
- Setting the clock 8
- Setting the maximum oor temperature 8
- Reading the oor temperature 9
- Frost protection mode 9
Timer functionality
- Activate Timer Mode 10
- Programming the timer 10
Technical specications 14
Veria Warranty 15
EN

3
ENIntroduction
Veria Control T45 is an advanced digital timer thermostat, which
allows you to control your oor heating system by either the oor
temperature, the room temperature or combined.
Please follow the instructions in this manual to ensure many years
of trouble free usage.
Congratulations with your new Veria oor heating system....
!Please notice that the thermostat must be installed by an
authorized electrician

4
Button and display description
Current room temperature
Heating element
warming
Day of the week
Thermostat on
On/o
Down
Up
Clock
Mode
Current oor temperature
EN
Timer mode activated
Frost protection mode activated

5
Installing and wiring the thermostat
To mount the thermostat to the wall box/wall socket, rst open the
thermostat by gently pushing the tabs in the buttom of the thermo-
stat. To x the thermostat, screw in properly sized screws into the
wall socket/wall box.
When proberly fastend and cables connected (see diagram below),
mount the frontpanel to the backpart again.
Electrical wall
box/socket
Wiring diagram
Remote sensor
Mains voltage: 85-240V~
raIP ting: IP30
S1
L
Load
S2 L
N
Load
N
13A
Max. load:
Temperature: 0T30
Veria ApS
Ulvehavevej 61
DK-7100 Vejle
Denmark
Model: Veria Control T45
85-240V~
Max
13A
EN

6
Basic functionality
POWER ON/OFF
To turn thermostat on or o press “ ”
SELECT HOW TO CONTROL YOUR FLOOR HEATING SYSTEM
Your Veria oor heating system can be controlled either by the:
• Floor temperature - program mode 2
The heating element turns on/o around a oor temperature
setpoint (the temperature shown in the display is the actual
oor temperature)
• Room temperature - program modes 1 & 4
The heating element turns on/o around a room temperature
setpoint (the temperature shown in the display is the actual
room temperature)
• Combined oor and room temperature - program modes
3 & 5
The heating element turns on/o around a room tempera-
ture setpoint with a requested max. oor temperature (oor
temperature is prioritized over room temperature)
Change between the above oor heating modes:
With the thermostat turned o.
Press “ ” and “ ” for 6 seconds
Select mode 1 to 5 (see table on next page)
After choosing the desired mode do not press any further buttons and
the thermostat will go back to normal standby mode.
EN

7
Basic functionality
RECOMMENDED SETTINGS
Veria recommends the following settings for dierent type of oor
constructions:
Top flooring
Program mode
Wooden
floor*
Tiled
floor**
1
(room sensor)
If total effect: 0W-1840W x
2
(floor sensor)
If total eect: 0W-2990Wx x
3
(combined floor and room sensor)
If total eect: 1840W-2990Wx x
4
(room sensor)
If total eect: 1840W-2990Wx
5
(combined floor and room sensor)
If total effect 0W-1840W x x
* Top ooring made of parquet, laminate, massive wood, carpet,
linolium or the like.
** Top ooring of tiles, concrete, marble or the like.
EN

8
Basic functionality
SETTING THE CLOCK
With the thermostat turned on.
Press “ ” once, hour will be ash.
Use the Up/Down key to select the hours.
Press “ ” again, minute will be ash.
Use the Up/Down key to select the minutes.
Press “ ” button again, till the week day ashes.
Use the Up/Down key to select the day of the week.
After setting week day do not press any further buttons and the
thermostat will go back to normal operating mode mode.
SETTING THE FLOOR TEMPERATURE MAX. LIMIT
This function is used for wooden oors mainly and is only available
in program modes using the oor sensor (program mode 3 and 5)
The temperature setting should be maximum 35C, which is also the
default set point of the thermostat.
If you choose to control the oor temperature solely by the oor
sensor (program mode 2) the max. oor temperature is set for 35C
and can‘t be changed.
Change the oor temperature max. limit (program mode
3 and 5)
With the thermostat turned o.
Hold the “M” button for 10 seconds until the display shows “ ”.
Now let go of the button “M” and the display will show “SET”.
You are now prompted to enter the maximum oor temperature
(temperature range 20°C-45°C)
EN

9
Basic functionality
READING THE FLOOR TEMPERATURE (only in program mode 3
and 5)
With the thermostat turned on.
Press “M” once, the “ FT ” will be ashed, and the display will
show the oor temperature.
In program mode 2 (oor sensor) the display always shows the current
oor temperature.
In program mode 1 and 4 (room sensor) the display always shows the
current room temperature.
FROST PROTECTION MODE
To enable frost protection mode.
With thermostat turned o.
Press “M” for 3 seconds.
Select 01 (00 = disabled)
When enabled and thermostat has been turned o, the heating will be
activated if the room/oor temperature is lower than 5°C; the heating
will be stopped if the room/oor temperature is higher than 7°C.
When frost protection mode has been enabled the display will show
“”.
EN

10
ACTIVATE TIMER MODE
When using the timer mode, you must rst activate the timer mode:
With the thermostat turned on, hold the “M” button for 3 seconds.
You can select below settings:
00 = Override (disable timer functionality)
01 = Programmable. And the display will show “ ”.
Leave the thermostat and it will go back to normal displaying.
PROGRAMMING THE TIMER - Mode 01
When programming you need to select Programmable function and
the display must show “ ” (see above)
You can now set the heating programs. The thermostat must have
4 heating periods for the weekdays and 4 heating periods for the
weekend.
Please notice that the programming of the whole calendar week
must take place in one continuous process, so it is a good idea to
have the periods written down for reference when programming
the thermostat.
Note, for the weekend you will also need to program 2 periods. You
can choose one of the periods to be very short or in extension of
the other.
Timer functionality
EN

11
Example, weekdays:
Period 1 starting at 07.00 - Temperature setting 22C
Period 2 starting at 08.30 - Temperature setting 18C
Period 3 staring at 17.00 - Temperature setting 22C
Period 4 starting at 23.00 - Temperature setting 18C
Example, weekend:
Period 1 staring at 09.00 - Temperature setting 22C
Period 2 staring at 23.00 - Temperature setting 18C
Period 3 staring at 23.01 - Temperature setting 22C
Period 4 staring at 23.02 - Temperature setting 18C
My settings:
Week days:
Period 1 on °C
Period 2 on °C
Period 3 on °C
Period 4 on °C
Weekend:
Period 1 on °C
Period 2 on °C
Period 3 on °C
Period 4 on °C
Timer functionality EN

12
How to progamme the timer:
Hold the “ ” for 3 seconds, the number 1 and
“Mo Tu We Th Fr” are displayed.
This indicates that you can program the rst switching time for the
week-day.
Use Up/Down key to set the required start time.
Press “ ” to accept this setting.
Use the Up/Down key to set the required temp.
Press “ ” to accept this setting.
Repeat for switching times 2-4 week-day.
After you have programmed times 1-4 for the weekday, you are now
able to set the switching times for weekend “Sa Su” will be displayed.
Use Up/Down key to set the required start time.
Press “ ” to accept this setting.
Use the Up/Down key to set the required temp.
Repeat for switching times 2-4 for the weekend.
To disable the timer, select “Override” (Mode 01)
How to override settings in TIMER MODE
At any time you can change the preset timer temperature settings
by pressing the Up/Down key.
Your manual override will apply until the start of the next timer cycle.
Thereafter the thermostat will resume your programmed settings.
Timer functionality
EN

13
EN
Notes

14
Technical specications
External sensor: NTC 10 kOhm at 25° C
Sensor values:
15°C
18°C
20°C
22°C
14,8 kOhm
13,1 kOhm
12,1 kOhm
11,2 kOhm
Display: LCD
Power consumption: <2W
Set-point range: Room: 5°C to 35°C
Floor: 20°C to 35/45°C
Accuracy: ±1°C
Buttons: Touch pad
Switch current rating: <13A (resistive load)
Mains voltage: 85-240V~
Dimensions: 86 x 86 x 13 mm (WxHxD)
Fixing screw width: 60mm
Housing: ABS + PC Flame Retardent
Operating rating: 0~30°C, 5~95% RH (non-con-
densing)
EN

15
Veria warranty
Warranty certificate
Electrician/installer:
Thermostat name:
Installation date:
Article number:
Stamp:
Stamp:
Please notice!
In order to obtain the Veria warranty an authorized electrician/
installer must ll in the below elds.
Name:
Telephone:
Address:
Zip code/City:
EN