VERIPURE VERIPUREVPC7000 User manual

1
OWNERS MANUAL VERIPUREVPC7000
REVISED 4/13/2020

2
2425 HUTSON ROAD
GREEN BAY WI, 54303
(920) 613-6771
www.veripure.com
THANK YOU FOR CHOOSING VERIPURE®
PLEASE TAKE A FEW MOMENTS TO FILL IN THE INFORMATION BELOW, SAVE THIS
MANUAL AS A CONVENIENT INFORMATION SOURCE FOR YOUR VERIPURE® SYSTEM.
Date of Purchase:
Purchased From:
Phone Number:
Serial Number:
Installed By:
Dealer Name:
Dealer Phone

3
IMPORTANT SAFEGUARDS AND PRECAUTIONS
INSTALL YOUR VERIPURE® SYSTEM IN COMPLIANCE WITH STATE AND LOCAL LAWS AND
REGULATIONS FOR PLUMBING AND ELECTRICAL CODES. AS WITH ANY WATER DEVICE, PLEASE
CHECK YOUR SYSTEM FOR LEAKS ON A REGULAR BASIS. CONTACT A PLUMBER IMMEDIATELY
IF ANY LEAK IS DETECTED.
VERIPURE® PERFORMANCE IS BASED UPON INPUT WATER WHICH MEETS MINIMUM EPA
NATIONAL PRIMARY AND SECONDARY DRINKING WATER STANDARDS.
SEE WWW.EPA.GOV/DWSTANDARDSREGULATIONS
ATTENTION: THIS UNIT IS DESIGNED FOR TREATMENT OF COLD WATER ONLY.
READ INSTRUCTIONS- ALL SAFETY AND OPERATING INSTRUCTIONS SHOULD BE READ BEFORE THE UNIT IS
OPERATED.
RETAIN INSTRUCTIONS– SAFETY AND OPERATING INSTRUCTIONS SHOULD BE KEPT IN AN ACCESSIBLE LOCATION
FOR FUTURE REFERENCE.
FOLLOW INSTRUCTIONS– ALL INSTRUCTIONS SHOULD BE FOLLOWED FOR MAINTAINING AND OPERATING YOUR
VERIPURE® SYSTEM PROPERLY.
MAINTENANCE PRECAUTIONS– ALWAYS TURN OFF THE WATER SUPPLY AT THE SINK OR WATER SOURCE AND
UNPLUG POWER JACK FROM THE VERIPURE® SYSTEM BEFORE PERFORMING ANY MAINTENANCE.
ACCESSORIES– DO NOT USE ANY ACCESSORIES, INCLUDING FILTER CARTRIDGES THAT ARE NOT RECOMMENDED
BY VERIPURE®
WATER AND MOISTURE– DO NOT ALLOW MOISTURE TO CONTACT ANY INTERNAL OR EXTERNAL ELECTRONIC
COMPONENTS. SHOULD A LEAK OCCUR, IMMEDIATELY SHUT OFF THE WATER SUPPLY AND CONTACT YOUR
DEALER OR DISTRIBUTOR FOR SERVICE.
POWER SOURCES– YOUR VERIPURE® SYSTEM SHOULD ONLY BE OPERATED FROM THE TYPE OF POWER SOURCE
INDICATED ON YOUR AC ADAPTER. IF YOU ARE NOT CERTAIN OF THE TYPE OF POWER SUPPLY TO THE OUTLET
PLEASE CONSULT YOUR VERIPURE® DEALER OR POWER COMPANY. ALTERNATIVE POWER SUPPLY ADAPTERS FOR
VOLTAGES FOUND IN MANY COUNTRIES OUTSIDE THE UNITED STATES ARE AVAILABLE THROUGH YOUR DEALER
ON SPECIAL ORDER. YOUR VERIPURE® SYSTEM MAY ALSO BE OPERATED WITH A BATTERY PACK OR GENERTOR.
POWER CORD PROTECTION– VERIPURE® RECCOMENDS THAT POWER SUPPLY CORDS SHOULD BE ROUTED SO
THAT THEY ARE NOT LIKELY TO BE WALKED ON OR PINCHED BY ITEMS PLACED UPON OR AGAINST THEM.

4
HOW YOUR VERIPURE® SYSTEM WORKS
YOUR PATENTED VERIPURE® SYSTEM HAS BEEN DESIGNED TO USE TWO STAGES OF PRIMARY FILTRATION
AND LOW LEVEL OZONE TECHNOLOGY®. OPERATIONAL MAINTENANCE AND REPLACEMENT REQUIREMENTS
ARE ESSENTIAL FOR THE VERIPURE® SYSTEM TO PERFORM TO SPECIFIATIONS. CONTACT YOUR LOCAL
DEALER OR DISTRIBUTOR FOR REPLACEMENT FILTERS AND PARTS, OR CONTACT VERIPURE FOR THE DEALER
NEAREST YOU. THE VERIPURE® SYSTEM IS RECCOMENDED TO BE CONNECTED TO MUNICIPAL WATER
SOURCES.
FOOD & SURFACES
GENERAL RECOMENDATIONS FOR USING OZONATED WATER ARE AS FOLLOWS-
PLACE ITEM OR ITEMS TO BE WASHED UNDER A STEADY STREAM OF VERIPURE® WATER AND RINSE.
FOOD PREPARATION: IT IS RECOMMENDED ITEMS BE RINSED FOR 3 MINUTES WITH VERIPURE® WATER.
FOOD ITEMS: PLACE IN A BOWL, COLANDER OR STRAINER. RINSE WITH VERIPURE® WATER.
STORING WATER
SELECT A CONTAINER THAT IS FOOD GRADE QUALITY, SUCH AS GLASS OR STAINLESS STEEL. THOROUGHLY RINSE
THE CONTAINER WITH VERIPURE® WATER AT LEAST TWICE. FILL THE CONTAINER TO WITHIN ONE TO TWO INCHES
FROM THE TOP AND REPLACE CAP.
STORE WATER IN REFRIGERATOR AND MAKE CERTAIN THE CAP IS REPLACED AFTER EVERY USE.
WHEN WATER IS FRESHLY OZONATED YOU MAY INITIALLY BE ABLE TO DETECT A SLIGHT HINT OF OZONE. PEOPLE
VARY IN THEIR SENSITIVITY TO OZONE. ANY HINT OF THE OZONE TASTE WILL DISAPPEAR WITHIN A SHORT PERIOD
OF TIME. YOUR SYSTEM PRODUCES MINIMAL WASTE WHILE PRESERVING MINERALS IN YOUR WATER.
IMPORTANT NOTE: VERIPURE® PERFORMANCE IS BASED UPON INPUT WATER WHICH MEETS MINIMUM
EPA NATIONAL PRIMARY AND SECONDARY DRINKING WATER STANDARDS.
SEE WWW.EPA.GOV/DWSTANDARDSREGULATIONS

5
INSTALLATION INSTRUCTIONS
BEFORE INSTALLING
1. YOUR VERIPURE® SYSTEM IS DESIGNED TO BE USED WITH COLD WATER ONLY.
2. NEVER RUN WARM OR HOT WATER THROUGH YOUR VERIPURE® SYSTEM AS HOT WATER
CAN DAMAGE THE CARBON BLOCK FILTER.
3. WATER TEMPERATURES ABOVE 90° F CANNOT CONTAIN DISSOLVED OZONE; THUS
ELIMINATING DISINFECTION. WATER TEMPS APPROACHING 85° F REQUIRE LONGER
PERIODS OF CONTACT TIME FOR DISINFECTION PURPOSES.
4. FOR OPTIMAL PERFORMANCE , LIMIT YOUR VERIPURE® SYSTEM TO 70 PSI OF WATER
PRESSURE. VERIPURE® RECCOMENDS A MINIMUM WATER PRESSURE OF 50 PSI. LOW
WATER PRESSURE WILL CAUSE YOUR VERIPURE® SYSTEM TO PRODUCE A LOWER
QUANTITY OF FILTERED AND OZONATED WATER.
5. POWER REQUIREMENTS ARE 120 VAC 60 HZ. USE AC ADAPTER PROVIDED WITH YOUR
SYSTEM.
NOTE: VERIPURE® UNITS ARE DESIGNED TO BE UNDER CONTINUAL WATER PRESSURE WHEN
INSTALLED AND NOT IN USE, THE ON/OFF VALVE AND OR FAUCET SHOULD BE ON THE
OUTLET OF THE VERIPURE AT OR BETWEEN THE POU AND VERIPURE® UNIT. THIS ENSURES
PROPER FUNCTION ON THE VERIPURE® .
VPC7000 INSTALLATION INSTRUCTIONS BEGIN ON NEXT PAGE (PAGE 6)

6
VPC7000 INSTALLATION INSTRUCTIONS
COMMERCIAL UNIT/SPECIAL APPLICATION UNIT
DUE TO VARIANCE IN THE VERIPURE® VPC7000 SYSTEM APPLICATIONS PER CUSTOMER, VERIPURE® IS UNABLE TO
PROVIDE INSTALLATION INSTRUCTIONS PER SPECIFIC APPLICATION. SPEC SHEET IS PROVIDED ON PAGE 7.
VERIPURE® UNITS ARE DESIGNED TO BE UNDER CONTINUAL WATER PRESSURE WHEN NOT IN USE, THE ON/OFF
VALVE AND OR FAUCET SHOULD BE ON THE OUTLET OF THE VERIPURE AT OR BETWEEN THE POU. THIS ENSURES
PROPER FUNCTION ON THE VERIPURE® .
DUE TO VARIANCE IN PLUMBING AND POWER OUTLETS; WE RECOMMEND THAT A PLUMBER AND OR
ELECTRICIAN INSTALL YOUR VERIPURE® SYSTEM. IF YOU CHOOSE TO INSTALL THE UNIT YOURSELF AND ARE IN
NEED OF ASSISTANCE PLEASE CALL (920) 613-6771 FOR ASSISTANCE.
INSTALLATION OF THE VERIPURE® SYSTEM MUST CONFORM TO STATE AND LOCAL PLUMBING AND ELECTRICAL
CODES, LAWS, AND REGULATIONS AND THE INSTRUCTIONS PROVIDED WITH YOUR VERIPURE® SYSTEM. FAILURE
TO INSTALL AS INSTRUCTED WILL VOID THE WARRANTY.
PLEASE CHECK YOUR VERIPURE® SYSTEM TO BE CERTAIN ALL ITEMS LISTED BELOW ARE INCLUDED.
QTY 1 AC ADAPTER (POWER SUPPLY) WITH OUTLET PLUG
QTY 1 1/2” TUBING 4’ IN LENGTH (OUTLET HOSE TO FAUCET)
QTY 1 1/2” TUBING 4’ IN LENGTH WATER SUPPLY TO FILTER INLET
QTY 1 MOUNTING PLATE
QTY 1 OWNERS MANUAL
QTY 3 MOUNTING SCREWS
QTY 1 SPANNER TOOL
QTY 2 RUBBER FEET
QTY 1 HEX WRENCH

7
VPC7000 INSTALLATION INSTRUCTIONS (CONTINUED)
COMMERCIAL/SPECIAL APPLICATIONS MODEL
CONNECTING STANDARD PUSH-IN FITTINGS
PUSH UP TO TUBBING STOP
PUSH THE TUBBING INTO THE FITTING, TO THE
TUBBING STOP. THE COLLET (GRIPPER) HAS
STAINLESS STEEL TEETH WHICH HOLD THE TUBBING
FIRMLY IN POSITION WHILE THE O-RING PROVIDES A
PERMANENT LEAK PROOF SEAL.
PULL ON THE TUBBING TO CHECK THAT IT IS SECURE.
A GOOD PRACTICE IS TO TEST THE SYSTEM PRIOR TO
LEAVING THE SITE AND/OR BEFORE USE.
DISCONNECTING STANDARD PUSH-IN FITTINGS
ENSURE THE SYSTEM IS DEPRESSURIZED BEFORE
REMOVING FITTINGS. PUSH IN THE COLLET AGAINST THE
FACE OF THE FITTING. WITH THE COLLET HELD IN THIS
POSITION THE TUBBING CAN BE REMOVED. THE FITTING
CAN THEN BE RE-USED.
FLUSHING INSTRUCTIONS
TURN ON THE WATER SUPPLY AND FLUSH NEW CARTIDGES FOR 5 MINUTES,
RUNNING WATER THROUGH THE SYSTEM
NEW FILTER ASSEMBLIES MAY CONTAIN “CARBON FINES” AND THE WATER
MAY BRIEFLY APPEAR GRAY, BUT WILL QUICKLY DISAPPEAR ONCE FLUSHED.
IMPORTANT– CHECK THAT ALL WATER LINES ARE SECURE AND FIRMLY SEATED
WITH NO EVEIDENCE OF WATER LEAKAGE. IF A LEAK IS DETECTED, SHUT OFF
WATER SUPPLY AND DISCONNECT LINES AND VISUALLY CHECK FOR ANY
DEFECTS AT THE END OF LINES. INSERT LINES BACK IN UNTIL FULLY SEATED
AND TURN WATER SUPPLY BACK ON. RECHECK FOR ANY LEAKS.

8
SPECIFICATIONS –VERIPURETM COMMERCIAL FOOD SANITIZER
(Model VPC7000)
Corona discharge ozone generator capable of providing up to .4-.7 PPM ozone concentraon in water up to one to ve gallons
(3.78-18.9 liters) per minute, 60– 300gallons (227-1,134 liters) per hour water ow.
5 Micron sediment lter to remove dirt and parculates. (NSF 42)
.5 Micron carbon block lter to remove chlorine, organic contaminants, including THM’s. Provides lead reducon and
cyst removal such as cryptosporidium and giardia. (NSF 42)
Disposable ozone dielectric and lters upon unit maintenance as indicated on LED overlay.
All materials in contact with water are food grade, high quality construcon.
Quick connect ngs source- John Guest, Parker.
Under counter installaon, Restaurant applicaon, Special applicaon
Compact size (16.25” L x 6” W x 18.25”H) (41.275cm L x 15.24cm W x 46.35cm H)
Light weight (9.0 lbs.) (19.8 kg).
No water wasted.
Low Voltage DC operaon with 115 VAC UL wall plug adapter (included)
Other input voltage adapters available. Oponal operaon o 12 volt baery.
TDS (Total Dissolved Solids) - 500 ppm
Free Chlorine 1 ppm
pH 6.5-8.5
Iron <0.1 ppm
Manganese <0.05ppm
Organics <1.0ppm
Hydrogen Sulfide None
Maximum Water Temp 100 F (37.7C)
Minimum Water Temp 35 F (1.6C)
Minimum Water Pressure 50 PSI
If you are uncertain about the quality of your tap water, it is recommended that you have your water tested by a professional testing laboratory.
As with all water treatment equipment, this product will perform as advertised when installed, operated and maintained according to manufac-
tures instructions.
NOTE: The Veripure™must be serviced, installed and maintained according to manufactures specifications to perform
as advertised .

9
MAINTAINING YOUR VERIPURE® SYSTEM
When performing maintenance as recommended, you should enjoy years of excellent
performance from your VeriPure® System. The LED indicator lights will conrm that your
VeriPure® System is working properly or if your system is malfunconing.
LED READOUT
INSTALLED VERIPURE®
There are two maintenance requirements for your VeriPure® System:
1. Change the lter cartridge assembly when indicated by the LED readout on your VeriPure®
System.
2. Replace the Dielectric tube whenever you change your lters (included in your
maintenance kit).
3. Refer to Maintenance Kit supplied by VeriPure, LLC on page 10.
CAUTION: REMOVE DIELECTRIC TUBE CAREFULLY AS STRAIGHT AS POSSIBLE TO PREVENT
BREAKAGE.

10
CHANGING THE FILTERS (VPC7000)
*COMMERCIAL UNIT/SPECIAL APP.*
PREPARATION
1. UNPLUG your VeriPure® System unit from electrical connecon before changing lter cartridges.
*THIS STEP IS IMPORTANT, IN ORDER TO RESET YOUR VERIPURE UNIT.
2. Turn o the water supply to your VeriPure® system.
3. Relieve the pressure on the Veripure® System by running unit or applicaon unl no water comes out.
TO REMOVE THE FILTER CANISTERS/USED FILTERS (VPC7000)
1. Place a towel/absorbent cloth under unit or work surface.
2. Using supplied lter wrench loosen lter canisters, be careful as these will be full of water.
3. Aer canisters are removed, pour out excess water and remove and discard of used lters.
4. Wipe out any debris or build up inside of canister.
TO INSTALL NEW FILTERS
1. Open new carbon/sediment lters from wrapping/packaging.
2. Place lter into canisters.
3. Replace and screw canisters back onto Veripure® Unit. note: sediment lter is on the right (water inlet side) with carbon lter
on the le (water outlet side) of the lter assembly.
4. Using lter wrench snug the canister ght, be careful not to overghten as you can crack the union ng between the lter
assemblies.
RETURNING THE UNIT TO USE
1. Plug unit back in. PRESS FILTER RESET BUTTON.
2. Open valve to water supply. Note: CHECK FOR WATER LEAKS AT CONNECTIONS, IF DETECTED PUSH TUBING TO SEAT FULLY.
For Replacement Filters and Dielectric Please
Reference Part#
VERIFILTERCFB-PB10
VERIFILTER7000SED
VERIMAINT-DIELECTRIC

11
CHANGING THE DIELECTRIC TUBE *(VPC7000)
CAUTION: The Dielectric Tube is glass and is fragile. Dielectric tubes are not designed for bending or to
sustain impact.
Dielectric Tube
1. Make sure your VeriPure® unit remains unplugged.
2. Locate the Dielectric.
3. Rotate the Dielectric cap one quarter (1/4) turn counterclockwise, to unlock the Dielectric.
You will feel a click.
4. Slowly remove the Dielectric tube from the VeriPure® housing by sliding the Dielectric out, IN A
STRAIGHT LINE, unl the Dielectric tube is completely separated from the VeriPure® housing.
5. The old Dielectric tube should be immediately discarded of into the trash/garbage. DO NOT
TOUCH THE GLASS BECAUSE STAINING FROM NITROGEN BY-PRODUCTS CAN STAIN THE SKIN.
6. Carefully slide new Dielectric tube in place unl the cap is ush with the VeriPure® Housing.
7. Rotate the Dielectric cap one quarter (1/4) turn clockwise unl it locks in place.
PROPER DIELECTRIC POSTION WHEN
INSERTING OR REMOVING.

12
FLUSHING INSTRUCTIONS
1. Turn on the water supply and FLUSH NEW FILTER CARTRIGES FOR 10 MINUTES, running water
through the system.
2. New lter assemblies may contain "Carbon Fines" and the water may briey appear gray ,but will
quickly disappear once ushed.
3. IMPORTANT - CHECK THAT ALL WATER LINES ARE SECURE AND FIRMLY SEATED WITH NO EVIDENCE
OF WATER LEAKAGE.
TROUBLE SHOOTING GUIDE
At VeriPure®, Inc. we expect your VeriPure® System to funcon properly for years as long
as you perform the maintenance according to the prescribed schedule. However, the
following table will help to idenfy any problem which may occur.
**NOTE: The service technicians at VeriPure® are trained to address any undened issues.
Please call (920)613-6771 should you not be able to diagnose any problem.
TROUBLE SHOOTING CHART LOCATED ON PAGE 13

13
PROBLEM POSSIBLE CAUSE SOLUTION
NO OZONE NO POWER TO SYSTEM PLUG CHECK POWER SUPPLY CORD IS SEATED INTO
VERIPURE SYSTEM AND WALL OUTLET.
RESET ANY GFI OUTLET RESET BUTTONS IN THE
AREA.
CHECK IN-HOME ELECTRICAL BREAKER.
FILTER LIFE IS EXPRIRED AND FILTER
IS LIMITING WATER PRESSURE TO
FLOW SWITCH CHANGE YOUR SYSTEM FILTERS.
WET GLASS DIELECTRIC
*CAREFULLY* REMOVE THE GLASS
DIELECTRIC AND INSPECT FOR
MOISTURE. IF WET, CONTACT VERIPURE
2425 Hutson Road Green Bay, WI 54303
920.613.6771
DROP IN HOUSE OR MUNICIPLE
WATER PRESSURE
LOW WATER PRESSURE WILL NOT
ALLOW YOUR SYSTEM OZONATION
COMPONENTS TO TURN ON. REGAIN
INCOMING WATER PRESSURE TO
MINIMUM OF 50 PSI. CONTACT YOUR PLUMBER
OR MUNICIPALITY.
DROP IN OR NO WATER
FLOW PLUGGED FILTER CHANGE YOUR SYSTEM FILTERS.
DROP IN HOUSE OR MUNICIPLE
WATER PRESSURE
CONTACT YOUR PLUMBER OR
MUNICIPALITY.
SYSTEM LIGHTS NOT ON NO POWER TO SYSTEM PLUG CHECK POWER SUPPLY CORD IS SEATED INTO
VERIPURE SYSTEM AND WALL
OUTLET.
RESET ANY GFI OUTLET RESET BUTTONS IN THE
AREA.
CHECK IN-HOME ELECTRICAL BREAKER.
PANEL INDICATION
LIGHTS HAVE NOT
RETURNED TO STANDBY
MAY HAVE NOT UNPLUGGED POWER
WHEN CHANGING FILTER/GLASS
DIELECTRIC TUBE
UNPLUG YOUR SYSTEM, WAIT 10 SECONDS
PLUG BACK IN AND PRESS THE RESET BUTTON
ON YOUR FRONT PANEL.
TROUBLE SHOOTING CHART

14
COMMON QUESTIONS ABOUT OZONE
HOW DOES THE VERIPURE® SYSTEM TREAT WATER FOR DRINKING?
VeriPure® provides a three-layered system. The rst two levels of ltraon are followed by injecng powerful ozone gas as a nal
stage disinfectant which ensures avorful and safe water.
1. As water passes through the rst sediment lter dirt, rust and other parculates from the water are removed.
2. Water is then ltered a second me when it passes through a carbon block lter which reduces cysts, chlorine, organics and
other impuries.
3. In the nal stage, ozone is injected into water via the dielectric tube.
HOW MUCH OZONE IS INJECTED INTO THE WATER?
The VeriPure® patented process creates Low Level Ozone Technology®. The ozone level in the water at one half (1/2) gallon per
minute is approximately 0.4 parts per million.
IS THE OZONE SAFE TO DRINK?
Yes. Due to our patented Low Level Ozone Technology®, the ozone turns back into oxygen very quickly. To give an idea of how
much ozone is in the water, 0.40 parts per million is the equivalent to one inch in 64 miles. The ozone in the water is within
the guidelines for ozone established by the FDA Boled Water Regulaons. Ozone was rst discovered in 1840 and has been
used to treat municipal drinking water since 1905.
DOES THE OZONE AFFECT THE TASTE OF THE WATER?
Inially, there is a slight aroma of ozone. This dissipates aer a short period of me, approximately 20 seconds.
IS THE OZONE GAS RELEASED INTO THE AIR BY VERIPURE® TREATED WATER HARMFUL?
No. Your VeriPure® System employs Low Level Ozone Technology® which is harmless. Ozone is classied as an irritang gas only in
high concentraons. The EPA has established strict guidelines liming 0.1 parts per million in the air for eight hours of connuous
exposure. Only a small poron of the ozone in the treated water is released momentarily into the air. If all the ozone in one gallon
of water were released into one cubic foot of air, the level would amount to 0.03 parts per million and it would revert to oxygen
within a few minutes.
WHAT IF MY WATER DOESN'T TASTE GOOD?
If your water suddenly has a bad taste, the problem could be the lter cartridge(s) are spent. Changing the lter may take
care of taste. Refer to "Filter change" Instrucons in this manual or contact your dealer or distributor.
IF I WANT TO REDUCE THE 'POPPING' WHEN I INITIALLY TURN ON MY VERIPURE®FAUCET,
WHAT CAN I DO?
Aer you have the faucet running, gradually decrease the ow to totally shut the faucet o( watching for the water stream to
become clear and void of bubbles). What this will do, is decrease the ozone in the water stream to virtually nothing. So the next
me you turn on the faucet, there will be no pressure in the line from previous use.

15
LIMITED WARRANTY
VeriPure, LLC warrants to the original purchaser of the VeriPure ®System products that such equipment is free from defects in
materials and workmanship.
If within one (1) year from the date of purchase, any product purchased from VeriPure, LLC shall prove to be defecve in
materials or workmanship, the VeriPure, LLC product shall be repaired or replaced, at VeriPure’s sole discreon,
at VeriPure, LLC's expense.
This warranty shall not apply to:
a. Product that has been damaged by improper installaon.
b. Product that has been improperly used or maintained.
c. Product subjected to temperatures below 35 or over 1200 F.
d. Product operated in water pressures exceeding 90 psi.
e. Product damaged aer delivery.
f. Product that has not been properly maintained.
VeriPure® Maintenance Kits are specically not covered under this warranty.
Requests for service under this warranty shall be made by contacng a local distributor or dealer in a mely manner following
discovery of the claimed defect. Any claim under this warranty must be made within 30 days following the expiraon of the one
year warranty.
VeriPure, LLC reserves the right to improve designs or change specicaons at any me without any conngent obligaon to
owners of products previously sold.
VeriPure, LLC shall not be liable for any consequenal, incidental or conngent damages. The foregoing warranes are
exclusive and in lieu of all other express warranes. Implied warranes, including but not limited to the implied warranes of
merchantability and tness for a parcular purpose, shall not exceed beyond the duraon of this applicable express warranty
provided herein. It is acknowledged that select states do not permit exclusive or limitaons of incidental or consequenal
damages or limitaons on the duraon of an implied warranty, so the above limitaons or exclusions may not apply to you.
This warranty extends to you specic legal rights and you may also have other rights which vary from state to state.
2425 HUTSON ROAD
GREEN BAY WI, 54303
(920) 613-6771
www.veripure.com
Table of contents
Other VERIPURE Water System manuals
Popular Water System manuals by other brands

Stratasys
Stratasys Objet WaterJet Site preparation guide

Everpure
Everpure QL2-OCS2 Specification sheet

Fusion
Fusion Oxi-Gen 150-OXi-2P Installation, operation and maintenance manual

Elkay
Elkay EZWSSMJO Installation & use manual

AquaSure
AquaSure PREMIER SERIES owner's manual

Zazen
Zazen Alkaline Water installation guide

Schwan
Schwan SC30E user guide

AmeriWater
AmeriWater CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM Operation & maintenance manual

SolarArk
SolarArk Solar Hot Water Systems installation manual

Rotex
Rotex HPSU compact 304 Installation and maintenance manual

Watermark
Watermark Xsential QUAD-RO Installation and maintenance manual

EZ Heat
EZ Heat Basic installation manual