VEVOR D-168 User manual

Technical Support and E-Warranty Certificate www.vevor.com/support
ELECTRIC BREAST PUMP
MODEL:D-168
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only
represents an estimate of savings you might benefit from buying certain tools
with us compared to the major top brands and does not necessarily mean to
cover all categories of tools offered by us. You are kindly reminded to verify
carefully when you are placing an order with us if you are actually saving half
in comparison with the top major brands.

MODEL: D-068
Have product questions? Need technical support? Please feel free to
contact us:
Technical Support and E-Warranty Certificate
www.vevor.com/support
NEED HELP? CONTACT US!
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our
user manual. The appearance of the product shall be subject to the
product you received. Please forgive us that we won't inform you again if
there are any technology or software updates on our product.
ELECTRIC BREAST
PUMP

Warning-To reduce the risk of injury, user must read instructions
manual carefully.
Warning:
It means that due to a mistake,death or serious injury could result
Danger:
Indicates that due to misoperation, death and injury may occur
This product is subject to the provision of European Directive
2012/19/EC. The symbol
showing a wheelie bin crossed through indicates that the product
requires separate refuse
collection in the European Union. This applies to the product and all
accessories marked
with this symbol. Products marked as such may not be discarded
with normal domestic
waste, but must be taken to a collection point for recycling electrical
and electronic
devices
Comply with the European security certification
This product is of protection class II. That means it is equipped with
enhanced or double
insulation.
Dear customer
Thank you for using our company's products. The products you purchased
from our company
Precautions
1. Before use, remove all packaging from this product and check if the
components are complete by referring to the product manual (component
description).
2. This product is a personal product, please do not use it by more than one
person to avoid affecting your health.
3. When cleaning this product, please unplug the adapter from the power socket

and do not use bleach, chemical disinfectant solutions/tablets, steel wool,
abrasive cleaners, or corrosive liquids (such as gasoline, acetone, or
alcohol)To clean this product.
4. When disassembling or installing components such as tees, silicone horns,
bell mouths, silicone cylinders, duckbill valves, etc., caution should be
exercised and excessive force should not be used.
5. The cylinder head cannot be rinsed with water. If water enters during cleaning,
shake off the water droplets and let them dry before continuing to use.
6. During use, it is necessary to ensure that the hose is clean and free of water
droplets, otherwise it will affect the performance of the host.
7. It is recommended to use a dedicated steam sterilizer or boiling water to
disinfect the accessories that need to be disinfected. Disinfectants such as
cabinets, microwave ovens, and pressure cookers should not be used for
heating and disinfection. The main unit should not be immersed in water for
cleaning.
8. The packaging, all components, and the host are not toys, please keep them
out of reach of children.
9. Store in a cool and dry place, avoid direct sunlight, and keep away from
ignition and heat sources.
10. When breastfeeding is difficult, the body should be relaxed before
breastfeeding; When breast swelling is painful, hot compress and massage
should be done first; If you feel uncomfortable with breastfeeding or cannot
produce milk multiple times, you should consult a doctor.
11. If any parts are damaged, to avoid danger, please stop using them and send
them to our company's service center for maintenance. Do not use
accessories or components produced by other manufacturers or without our
company's permission to avoid danger.
Declaration of Conformity
This product meets the requirements of corresponding national food safety
standards. The compliance information of the "food contact materials" and their
execution standards is as follows:
Component name
material quality
Executive standards
Temperature

Tee, cylinder head, dust
cover, 180ml wide mouth
milk bottle, bottle cap
PP
GB 4806.7-2016
-10~100°C
Silicone horn, silicone
cylinder, pacifier, duckbill
valve
silica gel
GB 4806.11-2016
-10~180°C
Product Introduction
product name
electric breast pump
Model
D -1 6 8
Main materials
A B S, silicone, P P
Executive standards
QB/T 5136
Charging input voltage
5 V
Lithium battery
3 . 7 V — 4 0 0 0 m A h
Rated power
10W
Noise limit
≤ 5 0 d B ( A )
protection against electric shock
Class I
Conditions of Use
5℃~40℃,10%~90%RH
Functional characteristics
Product Features
1. Biomimetic automatic: Controlled by a microcomputer chip program, it simulates
the intermittent sucking of breast milk by infants.
2. In the "bionic" mode, the intensity is adjustable at 9 levels, while in the
"massage" mode, the intensity is adjustable at 9 levels, effectively massaging the
breasts;In the "breast suction" mode, the intensity is adjustable at 15 levels, while
in the lactation mode, the intensity is adjustable at 15 levels, imitating the speed of
the baby's sucking rhythm and the size of the baby's sucking volume.
Product features
1. The cylinder design with gas-liquid separation structure ensures no milk return
during suction.
2. Detachable liquid silicone horn, imitating ergonomic principles, has the function
of sucking, massaging, squeezing breasts, and stimulating lactation during breast
suction.

3. The control panel is designed with a touch screen, displaying the interface and
making the operation process clear at a glance.
4. The host is equipped with a built-in battery, making it easy to use during power
outages or when going out from home.
Component Description
Serial
Numb
er
Compo
nent
Name
number
material
quality
Serial
Number
Compo
nent
Name
number
material
quality
1
Dust
cover
2
PP
8
Silicone
horn
2
Silicone
2
horn
2
PP
9
Silicone
cylinder
2
Silicone
3
Tee
2
PP
10
Cylinde
r head
2
PP
4
Straight
connect
or
2
PP/TP
R
11
hose
2
Silicone
5
Connec
ting line
1
/
12
Duckbill
valve
2
Silicone
6
main
engine
1
/
13
Pacifier
kit
2
Silicone
+PP
7
180ml
wide
mouthe
d milk
bottle
2
PP

1 8 2 9 3 10 4 5
13 7 12 6 11
Attention: Please check if the components are complete before use.
Installation instructions
Reminder: Before each use, components that come into direct contact with breast
milk should be disinfected in advance: milk bottles, silicone horns, three-way
silicone cylinders, duckbill valves, and bottle caps.
Installation steps:

1. Insert the silicone horn and horn mouth in sequence before inserting the dust
cover.
2. Insert the silicone horn and horn mouth components into the tee to ensure they
are in place.
(Note: When disassembling, hold the tee with one hand and swing the trumpet
assembly up and down slightly with the other hand, and gently pull it out.)
3. Place the cylinder and cylinder head into the tee and tighten the air tight.
4. Insert the duckbill valve into the bottom milk outlet of the tee to ensure that it is
installed in place without air leakage.

5. Screw the tee assembly into the bottle.
6. Insert the straight connectors of the hoses into the cylinder head and the
relative hole positions of the host machine to ensure that they are installed in place
without air leakage and can be used.
(Note: Before inserting the straight connector into the air duct hole of the host, the
dust plug must be removed first. Do not start the host before removing the dust
plug, otherwise it will affect the service life of the host.)
Instructions for use
Preparation before use
Before use, please check and ensure that all disinfected components (parts that
come into direct contact with breast milk) are clean and free of water droplets. The
suction device is firmly connected to the host.
Before breast suction, please use a damp and hot towel to clean, compress, and
massage the breasts and areola to relax the body and relieve the pain of bloating.
Panel operation instructions

Power on/mode switching
·Tap the " " button for 2 seconds to turn on the device and enter biomimetic
mode by default.
·After turning on, the breast suction/biomimetic /massage/lactation mode can be
switched.
Night operation switching
·Press the power button to turn off the screen light; Press the power button again
and the screen light will light up.
·When the working mode is "biomimetic", "≈" lights up. When the working mode
is "massage", ". C" lights up. When the working mode is "lactation", "◆" lights up.
When the working mode is "breast suction", "(" lights up and does not display
when turned off.
·In the "bionic" mode, the intensity is adjustable in 9 levels, and the screen
displays the corresponding gear number.
·When in the "massage" mode, the intensity is adjustable in 9 levels, and the
screen displays the corresponding gear number.
·When in the "lactation" mode, the intensity is adjustable in 15 gears, and the
screen displays the corresponding gear number.
·When in the "breast suction" mode, the intensity is adjustable in 15 gears, and
the screen displays the corresponding gear number.

·When powered by the built-in battery, the LED screen displays" " the battery
level in real-time and statically; Powered by charging line When charging, in the
shutdown state, " " dynamically displays the battery charging status in real
time.
·When the battery level drops to the minimum limit, the rightmost cell of the
battery symbol " " flashes and the other three cells do not light up,after 10
seconds of continuous operation, the LED screen turns off.
Breast suction intensity/frequency regulation
·In the "biomimetic" mode, the lactation intensity can be adjusted by using the
" " or " " keys, with a total of 9 adjustable levels.
·When in the "Massage" mode, the lactation intensity can be adjusted by using the
" or " " keys, with a total of 9 adjustable levels.
·When in the "lactation" mode, the lactation intensity can be adjusted by using the
" " or " " keys, with a total of 15 adjustable levels.
·When in the "breast suction" mode, the breast suction intensity can be adjusted
by using the " " or " " keys, with a total of 15 adjustable levels.
·In working mode, lightly touch the "M" button to freely switch between working
modes. When switching to the "lactation" mode,Default intensity last used gear;
When switching to the "Massage" mode, the default intensity is the last gear used,
When switching to "lactation" mode, the default intensity is the last used gear;
when switching to "breast suction" mode, the default intensity is the last used gear.
Pause function
·Press the button to pause the machine. Press it again to turn it on, but it
cannot be turned on when turned off. Pause when either side drops to zero.
Memory function
·Start the biomimetic/breast suction/massage/lactation mode, adjust the required
gear to run for more than 3 seconds, and the host will automatically remember.
The next startup will start with the previous running gear.
Battery powered/charging
·In working mode, connect the power adapter and receive power from the power
adapter; When the power adapter is not connected, the host automatically uses
the built-in battery for power supply.

·In the shutdown state, connecting the power adapter can charge the battery;
After being fully charged, it can work continuously for more than 3 hours·When
the battery level is too low, the host automatically stops working and prompts to
protect the battery; When the battery is fully charged, it automatically stops
charging to avoid damaging the battery.
Troubleshooting
The following problems may occur during the breastfeeding process. Please refer
to the provided methods for handling.
Phenomena
Cause analysis
Processing method
Low suction
Air leakage at the connection part
(duckbill valve, silicone horn,
straight joint, tee and host)The
output air circuit of the host is
blocked, such as bent hoses or
debris in the hose airway
Check all connecting
components,Reinstall,
organize, and clean
No suction
The duckbill valve is not properly
installed or deformed or damaged
Plastic components misused for
disinfection, causing deformation
and damage to cabinets, microwave
ovens, and pressure cookers due to
disinfection
Install the duckbill valve
or replace it with a new
accessory
Unable to
power on
The adapter is not properly
connected to the charging socket or
the DC power socket on the host
The lithium battery has run out of
charge
Plug in the adapter
again or charge before
use
Reflux
If milk or water is found to have
entered the cylinder or hose, check
if the cylinder is damaged or not
properly installed
Immediately shut down,
clean or replace the
cylinder before
reinstalling it
Maintenance
·The battery is built-in and non detachable, and self disassembly is prohibited.

·The charging/power supply of the host/battery requires the use of a designated
DC5V power adapter or mobile phone power adapter. Do not use other
non-standard power adapters for charging/power supply.
·Do not approach high temperatures or ignition sources during the use and
placement of the host. Do not place the host in a heater or ignition source to avoid
combustion and explosion.
·When the host is left unused for a long time, it is recommended to charge it once
a month.
·If there is an internal malfunction in the host, please do not disassemble it for
repair. It must be sent to the designated repair point of our company for
professional repair or replacement.
·Before use, accessories that come into direct contact with breast milk (milk
bottles, silicone horns, tees, cylinders, duckbill valves, bottle caps) should be
cleaned and disinfected in advance. They can be disinfected by steam or hot water,
and the disinfection time should not exceed 1 minute·The host cannot enter
water.
Declaration of Hazardous Substances
Hazardous substance
Component Name
P b
H g
Cd
Cr (MI)
PBB
PBDE
Plastic structural components
O
O
O
O
O
O
Silicone parts
O
O
O
O
O
O
electrical machinery
X
O
O
O
O
O
Display Assembly
X
O
O
O
O
O
Ac adapter
X
O
O
O
O
O
Hardware
X
O
O
O
O
O
PCB components
X
O
O
O
O
O

Battery
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
“O” indicates that the content of the harmful substance in all homogeneous
materials of the component is below the limit requirements specified in GB/T
26572.
“X” indicates that the content of the hazardous substance in at least one
homogeneous material of the component exceeds the limit requirements specified
in GB/T 26572, but is marked as' X 'in the table above“ ×” The reason why the
component content exceeds is because there is currently no mature technology in
the industry to replace it.
Indicative Explanation of the Regulations on the Management of Recycling
of Waste Electrical and Electronic Products in order to better care for and
protect the Earth, when users no longer need this product or when its
lifespan ends, please comply with relevant laws and regulations on the
recycling and disposal of waste electrical and electronic products, and hand
it over to a local manufacturer with nationally recognized recycling and
disposal qualifications for recycling and disposal.
FCC Information
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment!
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1) This product may cause harmful interference.
2) This product must accept any interference received, including interference that
may cause undesired operation.
WARNING: Changes or modifications to this product not expressly approved by

the party.responsible for compliance could void the user's authority to operate the
product.
Note: This product has been tested and found to comply with the limits for a Class
B digital device pursuant to Part 15 of the FCC Rules, These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This product generates, uses and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this product does cause
harmful interference to radio or television reception,which can be determined by
turning the product off and on, the user is encouraged to try to correct the
interference by one or more of the following measures.
Reorient or relocate the receiving antenna.
Increase the distance between the product and receiver.
Connect the product to an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for assistance.
Address: Baoshanqu Shuangchenglu
803long 11hao 1602A-1609shi Shanghai
Imported to USA: Sanven Technology Ltd. Suite 250,
9166 Anaheim Place, Rancho Cucamonga, CA 91730
Imported to AUS: SIHAO PTY LTD,
1 ROKEVA STREETEASTWOOD NSW 2122 Australia
Made In China
This manual suits for next models
1
Table of contents