Troubleshooting
Error Cause
Video outputs are not all
available
(e.g. 1 video input
6 video outputs)
The jumper on the circuit board is set
to duplicated number of video in-
puts/outputs
One or several monitors
have stripes in the picture
These distortions are caused by hum
in the picture which is a result of
connecting several monitors to dif-
ferent potentials.
1. Connect all devices to the same
phase
2. Use galvanic transformers be-
tween monitor and mains phase
3. Use an additional optocoupler for
each transmission line
The monitors have no
picture
1. Video signal lines interrupted or
defective; check all coaxial ca-
bles and BNC plugs
2. Power supply to camera
interrupted; check operating
voltage at camera
3. The video distributor is off:
a. Check and/or replace
mains fuse
Should none of the above remedies be successful, please contact your authorized
dealer with a detailed failure description.
Maintenance and care
Before starting to clean the device, disconnect the unit from power supply. Never use
any water or fluid to clean the device for reasons of electronic safety. Never put the unit
under water. To clean use a soft dry cloth. Never open the unit to clean inside. This
may only be done by authorized personnel according to the local safety regulations. If
the device will be handed over to third parties, make sure to include these operating
instructions.
Vicon Part Number 8009-8170-00-00 Rev 1105 7