Vicon CE UTP Series User manual

Vicon part number 8009-8242-00-00 Rev 0112
Page 1
INSTALLATION AND OPERATION MANUAL
CE-(X)UTP
EThErnET-ovEr-UTP/TwisTEd Pair
EXTEndEr wiTh Pass-ThroUgh PoE
The CE-(X)UTP Ethernet over UTP line consists of four models that support 100 Mbps
Ethernet as well as pass-through Power over Ethernet (PoE) over twisted pair cable
(CAT5, UTP). These models support transmission distances of up to 3,000 feet (914 m)
at 10 Mbps, or 2,100 feet (640 m) at 100 Mbps. The CE-1UTP, the CE-4UTP, CE-8UTP
and the CE-16UTP transport, one, four, eight or sixteen channels respectively. The
IEEE 802.3-compliant Ethernet electrical interface of these Ethernet extenders also
meets the requirements for IEEE 802.3af/at PoE power, passing-through up to 30 watts
of power per port to the powered device (PD). The CE-(X)UTP series may also be used
interchangeably with other Ethernet-over-UTP extenders.
Environmentally hardened to the requirements of NEMA TS-1/TS-2 for most out-of-plant
applications, and true plug-and-play design ensures ease of installation and operation.
LED indicators are provided for rapidly ascertaining the operating status of the device.
See Figures 7 – 9 on page 6 for LED explanations.
Packaged in a rugged aluminum housing, these units are designed for desktop or stand-
alone mounting. The CE-8UTP and CE-16UTP are offered in EIA 19” 1U high rack for easy
installation. See Figures A through C on page 7for mounting instructions.
See Figures 1 – 8for complete installation details.
Important Safety Warning:
Read and keep these directions
Heed all warnings
Follow all instructions
Do not use this apparatus near water
Clean only with a dry cloth
Install in accordance with the
manufacturer’s instructions
This installation should be made by a
qualied service person and should conform
to all local codes
See further safety instructions on page 8

Vicon part number 8009-8242-00-00 Rev 0112
Page 2
CAT5/6
UTP
CAT5/6 or UTP
CAT5/6
CAT5/6
BLACK
BLACK WITH
WHITE STRIPE
FIGURE 1 – CE-1UTP
FIGURE 3 – CE-4UTP
FIGURE 2 – CE-1UTP
insTaLLaTion and oPEraTion ManUaL CE-(X)UTP
RIGHT PANELLEFT PANEL
LEFT PANEL
TECH SUPPORT: 800.34.VICON (800.348.4266)

Vicon part number 8009-8242-00-00 Rev 0112
Page 3
12V Power Supply
Ground Screw
12V Power Supply
Ground Screw
FIGURE 4 – CE-8UTP
FIGURE 5 – CE-16UTP
insTaLLaTion and oPEraTion ManUaL CE-(X)UTP
TECH SUPPORT: 800.34.VICON (800.348.4266)
CAT5/6 or UTP
CAT5/6
CAT5/6 or UTP CAT5/6 or UTP
CAT5/6 CAT5/6
CAT5/6 or UTP
CAT5/6
CAT5/6 or UTP CAT5/6 or UTP
CAT5/6 CAT5/6

Vicon part number 8009-8242-00-00 Rev 0112
Page 4
insTaLLaTion and oPEraTion ManUaL CE-(X)UTP
TECH SUPPORT: 800.34.VICON (800.348.4266)
FIGURE 6 – POSSIBLE ETHERNET CONFIGURATIONS
Multiple configurations are possible. Consult you VIcon Sales Engineer.
≤3,000 ft (914 m) Cat-5
OR
≤5,000 ft (1524 m) Coax
CE-16UTP
4-Port Switch Extended over UTP or Coax
NVR
CE-16UTP
PoE Switch
≤328 ft
(100 m) Cat-5
CE-4US1TPC IP Cameras
IP Cameras
≤3,000 ft (914 m)
Cat-5
≤5,000 ft (1524 m)
Coax
Managed High Power Midspan
NVR
CE-16IPS
Switch
Data +
Power
Data
+Power
CE-1UTP CE-1UTP
CE-1UTP CE-1UTP PoE Camera
PoE Camera
CE-16UTP
Single Port CopperLine over UTP
NVR PoE Switch
≤3,000 ft
(914 m) Cat-5
≤328 ft
(100 m) Cat-5
CE-1UTP CE-1UTP PoE Camera
NVR
Multi Port over UTP
PoE Switch
≤3,000 ft
(914 m) Cat-5
≤328 ft
(100 m) Cat-5
CE-1UTP PoE Camera

Vicon part number 8009-8242-00-00 Rev 0112
Page 5
insTaLLaTion and oPEraTion ManUaL CE-(X)UTP
TECH SUPPORT: 800.34.VICON (800.348.4266)
iP CaMEra-End
insTaLL aTion (CE-1UTP)
Set the S1 10/100BaseT DIP switch
to the appropriate rate based on the
required maximum data rate and
maximum distance.
OFF = 10BaseT; ON = 100BaseT
Set the S2 Master/Slave DIP switch to ON for “Master” mode
Set the S3 1- or 4-pair DIP switch ON for 1-pair or OFF for
4-pair operation.
For systems not utilizing PoE, connect the 12V power supply
to the power connector of the CE-1UTP. A power adapter
connector is provided to simplify connection.
Connect the IP camera RJ-45 connector to the 10/100BaseT
Ethernet port of the CE-1UTP using a standard Cat5/6 cable,
100m length (max).
Connect one end of the long UTP cable to the RJ-45 connector
of the CE-1UTP.
The link LED on the 10/100 connector should be “ON” to
indicate propre connection between the camera and the CE-
1U T P.
EThErnET swiTCh/nvr-End
insTaLL aTion
CE-1UTP
Set the S2 Master/Slave DIP switch to OFF
for “Slave” mode
Set the S1 and S3 DIP switches to match the setting on the
camera-end.
CE-4UTP, CE-8UTP
and CE-16UTP:
For each channel used, set the
appropriate dip switches for each
channel to match the camera end.
Note: Multichannel units are preset to
“Slave” mode. No adjustment required.
For systems not utilizing PoE, connect
the 12V power supply to the power connector of the selected
CE-(X)UTP.
Connect the RJ-45 connector of the Ethernet switch to the
10/100BaseT Ethernet port of the selected
CE-(X)UTP using a standard Cat5/6 cable, 100 m length (max).
Connect one end of the long UTP cable to the RJ-45 connector
of the selected CE-(X)UTP.
The Link LED on the 10/100 Ethernet connector should be
“ON” to indicate proper connection between the switch and
the selected CE-(X)UTP.
The Link LED (Red for 100BaseT, Green for 10BaseT) will
be “ON” and not ashing to indicate conrmed connection
between the CE-1UTP and selected
CE-(X)UTP extenders.
On
Off
On
Off
S1 S2 S3 S4
S1 S2 S3 S4
1-P
4-P
10
100
S1 S2 S3S1 S2 S3

Vicon part number 8009-8242-00-00 Rev 0112
Page 6
insTaLLaTion and oPEraTion ManUaL CE-(X)UTP
TECH SUPPORT: 800.34.VICON (800.348.4266)
FIGURE 7 – POWER LED INDICATORS
FIGURE 8 – EXTENDED LED INDICATORS
FIGURE 9 – ETHERNET LED INDICATORS
POWER
RED Power is on
OFF Power is off
TRAFFIC (Extended) 10/100BaseT
GREEN – Connection is OK,
10BaseT mode
YELLOW Flashing, Trafc present –
RED – Connection is OK,
100BaseT mode
OFF No trafc –
TRAFFIC (Standard) Link
GREEN Flashing – Connection
is OK with trafc
–
YELLOW – Connection is OK
OFF No connection No connection

Vicon part number 8009-8242-00-00 Rev 0112
Page 7
MEChaniCaL insTaLLaTion insTrUCTions CE-(X)UTP
TECH SUPPORT: 800.34.VICON (800.348.4266)
FIGURE A
Dimensions are for the CE-1UTP standalone module.
FIGURE B
Dimensions are for the CE-4UTP standalone module.
FIGURE C
Dimensions are for the CE-8UTP and CE-16UTP modules.
3.73" (95 mm)
3.6" (92 mm)
17" (432 mm)
1.6" (40 mm)
3.3"
(84 mm)
1.6” (40 mm
1.75"
(44.5 mm)
3.25"
(82.5 mm)
1.6” (40 mm
1.15" (30 mm)
insTaLLaTion ConsidEraTions
The CE-1UTP and CE-4UTP are supplied as standalone modules.
The CE-8UTP and CE-16UTP can be installed as standalone
modules or can be rack-mounted with the addition of the provided
19-inch rack-mounting ear brackets.

Vicon part number 8009-8242-00-00 Rev 0112
Page 8
© 2011 Vicon Industries Inc. All Rights Reserved. Vicon and its logo are registered trademarks of Vicon Industries Inc.
89 ARKAY DRIVE | HAUPPAUGE, NY 11788 | USA
T: 631.952.2288 | F: 631.951.2288 | TOLL FREE: 800.645.9116
WEB: www.vicon-security.com
UK: +44 (0)1489 566300
MEChaniCaL insTaLLaTion insTrUCTions
•Read and keep these directions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with a dry cloth.
• Install in accordance with the manufacturer’s instructions.
• This installation should be made by a qualified service person
and should conform to all local codes.
• DO NOT bundle UTP or Coax signals in the same conduit as
high-voltage wiring.
• To reduce the risk of fire or electrical shock, do not expose these
products to rain, moisture, dripping or splashing.
• No objects filled with liquids, such as vases, shall be placed on
the equipment.
• DO NOT install the unit in a place where the operating ambient
temperature exceeds 75ºC.
• Make sure that the external power supply output voltage is in the
recommended range.
• Do not install near any heat sources such as radiators, heat
registers, stoves or other apparatus (including DVRs) that
produce heat.
• Protect the power cord from being walked on or pinched,
particularly at the power source, convenience receptacles and
the point where they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• Unplug this apparatus during lightning storms or when unused
for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way,
such as when a power supply cord or plug is damaged, liquid
has been spilled, objects have fallen inside the apparatus, the
apparatus has been exposed to rain or moisture, do not operate
normally or has been dropped.
• The main plus is used as the disconnect device and shall remain
readily operable.
WARNING: To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture. This
apparatus shall not be exposed to dripping or
splashing and no objects filled with liquids, such as
vases shall be placed on the apparatus.
WARNING: This apparatus is a Class I product. This product
must be connected to a mains socket outlet through
an AC to DC power supply.
WARNING: The mains plug is used as the disconnect device and
shall remain readily operable.
WARNING: For non-PoE applications, unit is to be connected to
a mains socket outlet through a Listed Class I power
supply rated 12 VDC or 24 VAC.
This manual suits for next models
6
Table of contents
Other Vicon Extender manuals
Popular Extender manuals by other brands

GE Security
GE Security NetworX NX-216Z8 installation manual

Globalmediapro
Globalmediapro KM03 quick start guide

Luxul
Luxul PWK6-24-FC2 Quick install guide

Greenlee
Greenlee HB10 Dynapress Operation manual

Xtreme Power Systems
Xtreme Power Systems X24 Installation and usage manual

Juice
Juice Booster 2 user manual