Victory Spa Daisy User manual

Installation manual
PORTABLE SPA
DAISY

IMPORTANT SECURITY INSTRUCTIONS
Acrylic surfaces cannot be cleaned with acetone-based means.
The guarantee does not apply to acrylic surfaces destroyed by improper cleaning agents.
Following precautions and rules of procedures shall be implemented during
installation and use of DAISY bathtub:
REMARK! In order to reduce the risk SPA shall not be used by children without adults'
supervision.
In order to reduce the risk of getting wounded suction parts shall not be removed. Suction system is
adjusted to specific flows of water generated by pumps. The bathtub shall never be used if any of the
suction parts is defected. The filter and pumps implemented are compatible with regard to the water
flow. If any of those elements is to be changed that fact shall be remembered.
REMARK! Consumption of alcohol, drugs or medicines before using the bathtub may lead
to accidental drowning.
Obese persons as well as persons with heart problems. and persons with low or high blood
pressure and blood circulation problems, diabetics shall consult their doctors before using SPA.
Remember that wet surface can be slippery. Pay special attention while entering and exiting the
SPA stand only on steps and never on the bath edge.
Use the thermal lid when you do not use the bathtub.
Use specifics for bath water for water treatment; maintain appropriate pH (7,4 - 7,6).
Remark: for cleaning acrylic surfaces delicate soaps shall be implemented. The soaps shall not
include caustic agents.

1. Description
200[cm] x 120[cm] x 88 [cm]
max. 450 [l]
3
Dimensions:
Capacity:
Number of seats:
- 19 x massage nozzles
- 1 x water pumps (1.5 kW)
- 1 x filter pump (0.75 kW)
- 1 x air nozzles 0.8 kW -
Air massage
- Flow water heating unit 2,7 kW
- Skimerofilter
- Big whirling nozzles
- Medium whirling nozzles
- Mini whirling nozzles
Electronic control
LCD function display
Water massage:
Nozzles for back
Nozzles for feet
Independent regulation of the water jet intensity by air system.
Water level sensor (protection of the pump against operating without water)
Air massage:
Flexible regulation of air massage intensity
A watch
Daily and weekly filtration program
RADIO FM and Mp3 player (optional)
Color underwater lightning - chromo therapy
Water temperature regulation - water flow heating unit with protection in case of water flow failure
Thermo insulation lid -10/15 cm
Head supports
!
!
!
!
!
!
1.Color underwater lightning - chromo therapy
2.Water suction - hydro massage
3.Water suction - filtration
4.Skimmer
5.Control desk
6.Loudspeakers (optional)
7.Air regulators
REMARK! After use please uninstall head supports!
- Too large whirling super nozzles
- Too large feet nozzles
11
23
45
6
6
7
7
980
480

2. Place preparation
Portable SPA bathtub may operate inside as well as outside. The place where the bathtub is to be
installed shall meet the following conditions:
a) Appropriate space of the room (in case of closed rooms)
b) Appropriate size of the transport road,
c) Connected voltage of 230V and ensured efficiency of electric terminal, in case of standard equipment
power consumption of the bathtub amounts to 10 kW and requires electric cable of 3x4mm ,
d) Water source to fill the bathtub,
e) Sewage terminal
f) Due to the danger of poring water over to the floor on which the bathtub is located the floor shall be
equipped with floor drain connected to the sewage system of the building. It is recommended to
construct around the bathtub a drain gutter covered by grate and connected to the sewage system of
the building as depicted in the drawing below. (In case of closed rooms).g) Stable and well leveled
foundation. The bathtub does not have the possibility of leveling,
h) Appropriate ventilation (in case of closed rooms).
2
I. Installation
Fig. Recommended construction of drain gutter
with connection to the sewage system in case of closed rooms

3. Transport of a bathtub.
It is recommended that the transport of bathtub be conducted in horizontal position in the original
packing of the producer on a wooden panel. It is possible to transport the bathtub in vertical position
after covers are removed.After taking from the pallet, the bathtub shall be transported by a forklift.
It is not allowed to handle cable and other elements of massage system during transportation. It is not
allowed t lean against bathtub edges.
4. Preparing o water an electric terminals
The bathtub does not require constant connection to water supply. Filling of the bathtub with water is
conducted by elastic pipes. The bathtub however requires connection to the sewage system for
emptying the bathtub. Terminal places are depicted in the picture below.
Electric terminal of 5,75 kW 230 V
electric cable of 3x4 mm2
Sewage terminal
Fig. Places of electric and sewage terminals

Connection to a power source:
Feeder cable must be connected to a permanent installation of IP X5 security level.
Fitting of plug is not allowed. Permanent installation located in the wall may be connected
through the junction box. IP X5 junction box shall be located beyond the body of the bathtub
and above 20cm from the floor. Connection to a power source shall be conducted through a
cable of 3 x 4 mm through 25A power excess switch by standard installed in the bathtub.
Remark! Bathtub is equipped with feeder cables of the following colors:
Phase conductor L: black or brown
Neutral conductor N: blue
Protection conductor: yellow-green
2
!
!
!
Way of connection to a power source
Connection to electric system
L1-N 230 VAC
3 x 4 mm2
N
L1
PE
3 x 4 mm2
PE L1 N
1 PHASE:
Power excess switch
B 25/phase ln=0,03A

II. Operation
1. Bathtub connections diagram
A Filtration pump
B Hydro massage pump
C Air blower- air massage
D 2,7kW heater
E Electronics
F Temperature sensor
G Flow sensor
- Massage nozzles section 9 draining valves
REMARK! After use please uninstall head supports!
C
A
E
D
B
F
G
99

2. Bathtub filling.
The bathtub does not require a permanent connection to water supply. The bathtub is filled with
water through elastic hose. The bathtub shall be filled until the water reaches the level of half a
skimmer. Only then will it be possible to switch on devices.
You should not fill the bathtub above the
mentioned level because then the water will overflow from the bathtub.
Before the longer break from using the bathtub water level shall be checked.
When the bathtub is being filled draining valves (9) should be closed.
In case the water level is lower
filtration and water heating will not operate as well.
3.Water disposal from the bathtub.
Water is disposed from the bathtub through a sewage system connected in the front of the
bathtub. In order to dispose water from the bathtub all the devices should be switched off.
Connect elastic hose ended with 3/4" to the sewage outlet located in the front of the bathtub.
Then remove a wooden element of the cover, which is located above the outlet. There are two
draining valves (9) located in that place and they should be opened. When the valves are open
the water will be disposed from the bathtub.
99
Fig. Location of the draining valves

Additionally water massage is supported by air. Water nozzles are constructed in such a way
that water flowing through them forms underpressure, which sucks in air in a natural way.
Intensity of airflow is regulated by regulators installed on the edge of the bathtub.
REMARK! Air regulators change intensity of a water massage.
Increasing intensity of a water massage can be conducted
by turning the knob of the regulators into the right whereas
decreasing intensity of a water massage is conducted by
turning the knob into the left.
This section working with
filtration
4. Hydro massage.
System of water massage (hydro massage) consists of the following elements:
- A set of 19 water-air nozzles, providing water or a water air blend to the bathtub,
- 1 hydro massage pumps ensuring circulation of water
- 2 air flow regulators providing air to hydro massage nozzles installed on the edge of the
bathtub regulating intensity of the massage,
-1 water suction devices

Zones of air regulators control .
Nozzles
SPA DAISY has been equipped with a set on nozzles:
Big rotation nozzle with the possibility
of regulation intensity of a water massage
Medium rotation nozzle
Mini rotation nozzle
Each of those two regulators
is responsible for controlling
nozzle sections.
2
1
6
6
4
Quantity Nozzles
Large rotation super nozzle
Large feet nozzle

Regulation of intensity of water flow through the big nozzle
1
2
1. Cover plate
2. Rotational element of the nozzle
In order to regulate water flow element nr 1 (nozzle
cover plate) shall be turned according to the
direction of arrows.
1. The frontal lid of the skimmer
shall be removed by raising up.
2. Initial filtration bin
shall be removed.
3. The filter located in the
skimmer shall be removed.
5. Filtration system
a) Filtration circuit.
Filtration and water heating systems form filtration circuit. Filtration circuit consists of the
following elements:
-Skimmer with replaceable filter,
-Filtration pump,
- Water heater electric heater,
-Bottom suction device.
b) Replacing and cleaning of the filter.
The skimmer is equipped with filter, which shall be cleaned at least once a week.
We recommend replacing the filter once a year.
In order to remove the filter:

6. Operation of other devices of the bathtub.
Setting of the sensor of the water level.
We fill the bathtub until the moment when the water level reaches the level of the installed
sensor. With the screwdriver we unscrew very slowly as presented in the picture until the diode
lights up. Lightning of the diode confirms proper setting of the sensor. Then water shall be
disposed from the bathtub. When the water level is lower than the level of installed sensor the
diode switches off.
Diode
Tap screw
Setting the sensor on the water level
Resetting of water heater safety switch
Hole plug
When the power supply circuit of the heater is
disconnected by the safety switch you should:
1. Disconnect power supply to the bathtub
2. Remove the wooden element of the cover
located in the frontal left side of the bathtub
3. Unscrew the hole plug covering Reset switch
on the electric heater
4. Press Reset switch
5. Screw the hole plug
6. Install the wooden element of the cover
7. Switch on power supply
Reset switch

Thermal lid.
DAISY bathtub is equipped with a thermal lid. We shall always remember to cover the bathtub
in case we do not intend to use for a longer period of time. The thermal lid prevents the water
from cooling or evaporating which is extremely important in closed rooms. The thermal lid helps
to maintain the water clean. It is not allowed to stand or lie down on the closed thermal lid. After
the thermal lid is closed it should be secured against accidental opening or slipping off.
DAISY bathtub with closed thermal lid
6. Cleaning and repairing of acrylic surface
Only delicate cleaning agents without acetone, abrasive or caustic substances may be
used.
REMARK!! In case of damages caused by improper use the guarantee does not
apply.
An important property of the sanitary acrylic is the smoothness of its surface. That is why
keeping the bathtub clean, desinfection and removing calcium and iron residues is very simple.
We recommend traditional cleaning agents with the reservation that:
The bathtub surface shall be cleaned with a soft cloth or a sponge.
Mechanical damages (not deep scratches) to the acrylic surface can be easily repaired.
In case of slight scratches polishing agents containing wax can be implemented as for
instance agents for car body polishing agents;
In case of deeper scratches or lines abrasive paper of 1000, 1500, 2000 granulation can be
implemented together with polishing agents.
!
!
!
!
7. Preserving the bathtub for winter or a longer break.
Before leaving the bathtub for a longer period of time without operation one should:
- Check the water level in case of too low water levels the water should be refilled. It is advised
that in case of planned longer breaks the water level should be increased to the level of 3/4 of
the skimmer. It is very important in case of low temperatures.
- Close the thermal lid and protect it against accidental opening or slipping off.
In case of a planned leaving of the bathtub for without operation for a longer period than a
month the water shall be disposed from the bathtub and power supply shall be disconnected.

8. Desinfection
Before the first use and once a week pH and content of free fluorine shall be checked. The
examination shall be conducted with the use of attached POOLTESTER, in the following way:
1. Remove the lid of POOLTESTER, rinse the boxes with examined water.
2. Fill the boxes with examined water.
3. Place PENTOLRED tablet in the left box, place PDP tablet in the right box. Make sure you do
not touch the tablets with your fingers.
4. Close the lid and shake the water sample so that the tables dissolve.
5. In order to read POOLTESTER results keep the tester against the light. Appropriate values
can be read by comparing the color of solution with the color scale.
6. The value on the left hand side refers to pH value, whereas the value on the right hand side
refers to the free chlorine.
POOLTESTER for pH and free chlorine testing
The most important chemical parameter deciding on the influence of water on the skin is pH
reaction. It influences the activity of desinfection substances and calcium-carbonate balance.
It is recommended that pH value amounts to 7.0 7.4. To high pH value may result in:
Worsening of desinfection agents' efficiency,
The necessity of using more chlorine,
Eyes and skin irritation,
CaCO precipitating.
Too low pH value may result in:
Corrosion,
Eyes and skin irritation.
The bath water offers good conditions for microorganisms to grow (bacteria, fungi, algae).
Only some bacteria and fungi are mycotic and may constitute danger for people taking a bath.
However in case of a quick grow they may lead to the appearance of slippery residues and
water cloudiness. In order to ensure appropriate hygiene of bathing it is necessary to conduct
efficient desinfection. The desinfection in case of the DASIY bath is conducted by hand dosing
of the agent increasing the level of the active chlorine. It is recommended that the content of
free chlorine amount to: 1.0-1.5 mg/l.
!
!
!
!
!
!
3

Keeping very low level of free chlorine in water (slightly above 0.2 mg/l) may result in:
The danger of infecting the bath water
Elimination of irritation of conjunctivas and mucous membranes.
Keeping very high level of free chlorine in water (above 4.0 mg/l) may result in:
Theoretic elimination of the possibility of infecting bath water
Potential breathing disorders (especially in case of closed rooms),
Possibility of irritation of conjunctivas and mucous membranes.
Ø
Ø
Ø
Ø
Ø
Agents for water preservation attached to DAISY bathtub
a)ChlorShock
b) pH minus
Make sure water pH is appropriate before chlorination.
The value of the free chlorine shall not be lower than 0.3 mg/l. It is recommended to use
the agents in the evening one day before the planned bathing.
In order to achieve appropriate pH value „pH minus” shall be implemented. In order to lower the
pH value by 0.1 about 5 g of the agent shall be implemented. It is recommended that the agent
is distributed evenly in the water surface, meanwhile the pH value should be checked. When the
appropriate level of pH is reached Chlor Shock can be implemented. If the water is transparent
about 3 g of the agent shall be implemented and when it gets cloudy use about 10 g of the
agent.
Table of contents