Videofied WIO100 Installation and operating instructions

The WIO100 Input/Outputs module is one of the removable communication modules that can be
installed on the W panel.
The WIO100 module has one programmable input and two programmable outputs.
WIth this module, the W panel can be connected to wired devices such as :
• Panic buttons, temperature sensors, safety light curtains, wired door contacts, glassbreak, shock, flooding or
gas detectors (wired input).
• Flashing lights, spotlights, smoke equipment, light or sound indicator (wired output).
The programmable input can be configured as normally open (NO) or normally closed (NC), it can also be
supervised in order to detect cable tampers.
With the Mapping, the programmable input can be set up to take a 10 second video from any Videofied®Motion Viewer™
when the detector linked to the programmable input is triggered.
The programmable input can also be wired to an existing alarm system in order to add video-vérification. That mode is
called XTENDER mode.
Programmable outputs are normally open drys contacts that close when the output is activated.
Index
1. Programmable input 2
1.1 Programmable input menu 2
1.2 Event list 3
1.3 Programmable input wiring and supervision 3
1.4 XTENDER Mode 4
1.5 XTENDER Mode configuration 5
2. Programmable outputs 6
2.1 Programmable outputs triggering 6
2.2 Access to programmable outputs menu 7
2.3 Programmable outputs menu 7
W Panel www.videofied.com
Doc. - Ref. 240-WIS100
Version : February 2015
APPLICATION NOTE
WIO 100 Input/Outputs module

1. Programmable input
The programmable input is triggered by a dry contact connected to its terminals switches.
1.1 Programmable input menu
PROGRAMMABLE
INPUT
GENERAL
PARAMETERS
Niv. 4
CONFIGURATION
OK or YES OK or YES
TRANSMISSION
DISABLED
PROGRAMMABLE
INPUT
SUPERVISION
MAPPING
DISABLED
SEND EVENT
ALARM
EVENT TYPE
INTRUSION
ENTRY DELAY
20
SIREN MODE
SIREN
INPUT NAME
INPUT 1
DETECTION NB
0
INPUT TYPE
NORMALLY OPEN
Sets if and how the input is armed
Enabled : 24h active input (example : panic button).
Disabled : Disabled input.
Only if armed : Input disabled when the panel is disarmed.
Alarm : the event is transmitted upon input triggering
Alarm / End : the event is transmitted upon imput triggering and on event restoral.
Normally Open : Short circuit will trigger the input.
Normally closed : Open circuit will trigger the input.
Type of event assigned to the input (intrusion, smoke detection, tamper, assistance
detection, etc...).
You can find the event list on the next page.
Entry delay in seconds between the input triggering and the alarm triggering/event
transmission.
0-3600 seconds.
Input Name. This name can be seen by the monitoring center when the input triggers.
Choose a detailed name.
Siren type for the programmable input
Siren : the siren will be enabled and the keypad will beep.
Silent : no siren, no beeps.
Without siren : only the keypad beeps.
Links a Videofied®MotionViewer to the input.
When the input triggers, the linked camera will record a video and transmit it to the
security server.
Generates a welcome ring on the keypad and indoor siren when the input is
triggered. For more information, please refer to the Chime Application Note.
Only displayed if the event type is Detection.
The monitoring center assign this number to the detection type.
CHIME
PARAMETERS
SC & OC Superv. : Enables the programmable input supervision (open and short
circuit).
Transmission : Type of transmission sent to the security server (Alarm, Alarm/End
and Not transmitted).
2
W Panel www.videofied.com
WIO 100 Input/Outputs module APPLICATION NOTE

1.2 Types d’évenements
INTRUSION
TAMPER
PANIC BUTTON
INCORRECT CODE
DURESS CODE 1
DURESS CODE 2
SUPERVISION
RADIO JAMMING
LOW PANEL BATT.
LOW DEVICE BATT.
AC POWER MISS
PANEL RESET
SYSTEM ARMED
SYSTEM DISARMED
PERIODIC TEST
ALARM CANCEL
SMOKE DETECTION
PHONLINE MISS.
TMT REQUEST
MEDICAL ASSIST.
ETHERNET CABLE
DETECTION
The programmable input can be assigned to different event types according to the source
of the linked device triggering.
The security server will receive this event when the programmable input triggers.
Important :
These events are different from the events transmitted list in the FRONTEL SECURITY
PARAMETERS menu. They will be sent no matter how the events listed in the EVENT
TRANS. MODIFICATION are set.
1.3 Programmable input wiring and supervision
Programmable input wiring
IN +
IN -
OUT 1
OUT N
OUT 2
Programmable input supervision
4.7kΩ
4.7kΩ
Wired detection device
Connect two 4,7kΩresistors (provided) as shown in the above scheme.
3
W Panel www.videofied.com
WIO 100 Input/Outputs module APPLICATION NOTE

Dry contact
Existing control
panel
1.4 XTENDER mode
The Videofied® W panel can be used as a standalone alarm system.
When fitted with the WIO100 input/outputs module, it can also be wired to an existing alarm system with a
programmable dry contact.
When used in XTENDER mode, the W panel can only be armed when the programmed condition for arming is met.
For example, if the XTENDER input type parameter is set as normally open, the system will arm when the circuit
is closed.
Opening the circuit will disarm the panel.
4
W Panel www.videofied.com
WIO 100 Input/Outputs module
When used in XTENDER mode, arming devices (keypads, keyfobs, badge readers)
cannot arm or disarm the system.
To switch between standalone mode and XTENDER mode, go to the menu :
CONFIGURATION (Lvl 4) > GENERAL PARAMETERS > XTENDER
Note :
Enabling the programmable input will automatically disable the XTENDER mode and switch the W panel in standalone
mode. In the same manner, enabling the XTENDER mode will automatically disable the programmable input.
Like when it is used as a
programmable input, the
WIO100 input used as an
XTENDER arming input can
be supervised thanks to the
two 4.7kΩresistors provided
with the module.
APPLICATION NOTE

1.5 XTENDER Mode configuration
5
W Panel www.videofied.com
WIO 100 Input/Outputs module
ARMING PROFILE :
FROM THE HOST
When a WIO100 Input/outputs module is fitted on the W panel, the XTENDER mode can be configured either during
initial configuration, or in the GENERAL PARAMETERS menu.
• During initial configuration, the ARMING PROFILE screen will appear.
Choos FROM THE HOST instead of STANDALONE to access the XTENDER
mode configuration menu.
• Access the configuration menu from the GENERAL PARAMETERS menu :
CONFIGURATION (Lvl 4) > GENERAL PARAMETERS > XTENDER
MODE SLOW : The panel will arm each device one at a
time saving battery life. This mode is recommended.
MODE FAST : The panel will arm all devices
at the same time. This mode increases
significantly the battery consumption.
Press
OK
or
YES
to select the parameter.
Enter the value for your Entry Delay up to 255 seconds
and press
OK
or
YES.
Note : In From the Host mode, the entry/exit delay are
managed by the master system.
Arming Confirmation is the number of seconds the
system will wait to arm after voltage is latched on the
arming input. This feature can be used as an exit delay,
we suggest you to enter the same value as your master
system exit delay.
Enter the value you would like for the Arming
Confirmation and press
OK
or
YES.
ARMING PROFILE :
FROM THE HOST
ENTRY DELAY
VALUE (0-255) :
(000) : _
TRANSMISSION DELAY
VALUE (0-600) :
(000) : _
ARMING CONFIRMATION
VALUE (0-240) :
(0) : _
OK or YES
ARMING MODE
MODE :
SLOW
MODE :
FAST
OK or YES
OK or YES
OK or YES
The transmission delay value set the delay between
the detection of an event and its transmission to the
monitoring center.
Except when specifically required, please enter 0.
Enter the value you would like for the Transmission Delay
and press
OK
or
YES.
APPLICATION NOTE

The WIO100 programmable output is a dry contact
triggering a wired external device. These outputs
can only be wired to SELV circuits. The woltage and
current are limited to 24V/100mA.
Programmable outputs OUT 1 and OUT 2 can be
triggered by :
• An event linked to the panel or its devices.
• The triggering of the programmable input or the
arming input.
OUT 1 programmable output connection
2. Programmable outputs
2.1 Programmable outputs triggering
INTRUSION
TAMPER
PANIC BUTTON
INCORRECT CODE
DURESS CODE 1
DURESS CODE 2
SUPERVISION
RADIO JAMMING
LOW PANEL BATT.
LOW DEVICE BATT
AC POWER MISS.
PANEL RESET
SYSTEM ARMED
SYSTEM DISARMED
PERIODIC TEST
ALARM CANCEL
SMOKE DETECTION
PHONELINE MISS.
TMT REQUEST
MEDICAL ASSIST.
ETHERNET CABLE
DETECTION
PROG. INPUT 1
You can find below the list of events that can trigger a programmable output.
6
W Panel www.videofied.com
WIO 100 Input/Outputs module APPLICATION NOTE

2.2 Access to programmable outputs menu
PROGRAMMABLE
OUTPUTS
GENERAL
PARAMETERS
Lvl. 4
CONFIGURATION
OK or YES
OK or YES
2.3 Programmable outputs menu
OUTPUT 1
PROGRAMMABLE
OUTPUTS
STATUS
DISABLED
Enable the output.
LENGTH ACTIV.
180 sec
Output activation duration. The output cannot be constantly active.
0-900 seconds
REMOTE CONTROLLED
ENABLED
Remote activation authorization. Allows the monitoring center to
enable the programmable output in cas of alarm.
EVENT TYPE
INTRUSION
Type of event assigned to the input (intrusion, smoke detection,
tamper, assistance, detection, etc...). When the event occurs, the
output will activate.
OUTPUT NAME
OUTPUT 1
Output name. In order to recognize which system is connected to
the output, choose a detailed name.
7
North American Headquarters
1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : usasales@rsivideotech.com
EMEA SALES
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
W Panel www.videofied.com
WIO 100 Input/Outputs module APPLICATION NOTE