manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Viessmann
  6. •
  7. Boiler
  8. •
  9. Viessmann Vitodens 100-W WB1C User manual

Viessmann Vitodens 100-W WB1C User manual

Other manuals for Vitodens 100-W WB1C

1

This manual suits for next models

1

Other Viessmann Boiler manuals

Viessmann Vitodens 200-W System Operating instructions

Viessmann

Viessmann Vitodens 200-W System Operating instructions

Viessmann Vitodens 111-W Quick start guide

Viessmann

Viessmann Vitodens 111-W Quick start guide

Viessmann Vitodens 200-W System User manual

Viessmann

Viessmann Vitodens 200-W System User manual

Viessmann Vitorond 100 User manual

Viessmann

Viessmann Vitorond 100 User manual

Viessmann VITODENS 333 User manual

Viessmann

Viessmann VITODENS 333 User manual

Viessmann VITOCROSSAL 300 Operating instructions

Viessmann

Viessmann VITOCROSSAL 300 Operating instructions

Viessmann VITOROND 200 User manual

Viessmann

Viessmann VITOROND 200 User manual

Viessmann VITODENS 200 Instruction manual

Viessmann

Viessmann VITODENS 200 Instruction manual

Viessmann VITODENSd 100-W Instruction manual

Viessmann

Viessmann VITODENSd 100-W Instruction manual

Viessmann VITOMAX 200-HS Training manual

Viessmann

Viessmann VITOMAX 200-HS Training manual

Viessmann Vitosorp 200-F User manual

Viessmann

Viessmann Vitosorp 200-F User manual

Viessmann Vitocrossal 200 CM2 500 Operating instructions

Viessmann

Viessmann Vitocrossal 200 CM2 500 Operating instructions

Viessmann Vitomax HW Series Training manual

Viessmann

Viessmann Vitomax HW Series Training manual

Viessmann VITODENS 200-W B2HE 85 User manual

Viessmann

Viessmann VITODENS 200-W B2HE 85 User manual

Viessmann VITOTRANS 300 Operating instructions

Viessmann

Viessmann VITOTRANS 300 Operating instructions

Viessmann PYROMAT ECO Quick start guide

Viessmann

Viessmann PYROMAT ECO Quick start guide

Viessmann VITOCROSSAL 200 Operating instructions

Viessmann

Viessmann VITOCROSSAL 200 Operating instructions

Viessmann Vitodens 100 User manual

Viessmann

Viessmann Vitodens 100 User manual

Viessmann Vitodens 100-W Quick guide

Viessmann

Viessmann Vitodens 100-W Quick guide

Viessmann VITOTRONIC 300 Quick guide

Viessmann

Viessmann VITOTRONIC 300 Quick guide

Viessmann Vitodens series User manual

Viessmann

Viessmann Vitodens series User manual

Viessmann VITOPLEX 200 Operating instructions

Viessmann

Viessmann VITOPLEX 200 Operating instructions

Viessmann VITOMAX 200-HW User manual

Viessmann

Viessmann VITOMAX 200-HW User manual

Viessmann VITROND 200 User manual

Viessmann

Viessmann VITROND 200 User manual

Popular Boiler manuals by other brands

IDEAL IMAX XTRA EL 320 user guide

IDEAL

IDEAL IMAX XTRA EL 320 user guide

UTICA BOILERS BC3D Installation, operation & maintenance manual

UTICA BOILERS

UTICA BOILERS BC3D Installation, operation & maintenance manual

Lochinvar SOLUTION 260000 Installation & service manual

Lochinvar

Lochinvar SOLUTION 260000 Installation & service manual

Weil-McLain EG 6 Series manual

Weil-McLain

Weil-McLain EG 6 Series manual

RBI LCD Series Installation & operation manual

RBI

RBI LCD Series Installation & operation manual

Baxi MainEco Combi 28 Installation and service manual

Baxi

Baxi MainEco Combi 28 Installation and service manual

Unical ALKON R 24 Installation and Servicing Manual

Unical

Unical ALKON R 24 Installation and Servicing Manual

Automatic Heating Gasogen Installation and Servicing Manual

Automatic Heating

Automatic Heating Gasogen Installation and Servicing Manual

Alpha GasSaver GS-1 Installation and servicing instructions

Alpha

Alpha GasSaver GS-1 Installation and servicing instructions

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Baxi

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Vaillant

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Kärcher HWE 4000 Gas manual

Kärcher

Kärcher HWE 4000 Gas manual

Radijator BIO max 23.1 instruction manual

Radijator

Radijator BIO max 23.1 instruction manual

Granby BKC Installation, operation and maintenance manual

Granby

Granby BKC Installation, operation and maintenance manual

Brunner BSV 20 Instructions for use

Brunner

Brunner BSV 20 Instructions for use

Potterton 50e Installation and Servicing Manual

Potterton

Potterton 50e Installation and Servicing Manual

UTICA BOILERS TriFire Assembly instructions

UTICA BOILERS

UTICA BOILERS TriFire Assembly instructions

ECR International UB90-125 Installation, operation & maintenance manual

ECR International

ECR International UB90-125 Installation, operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Note on installation
forheating engineers
System boiler wiring instructions
for Vitodens 100-W, Typ WB1B & Typ WB1C
TheVitodens100-Wsystemboiler
offersseveralinstallationalterna-
tives.
From traditional 'Y' or 'S' plan
(2-pipe system) to weather compen-
sated 4-pipe system connected to an
un-vented DHW cylinder using the
integral expansion vessel and diverter
valve.
The advantages of connecting the
system boiler to a 4-pipe system are
as follows:
•
The DHW circuit operates indepen-
dently of the CH circuit
•
Dual temperature control, which
means the CH circuit can be
operated on weather compensated
system (reduced flow temperature)
•
Usingtheboilerstemperature
cut-outdeviceandintegraldiverter
valve to protect the cylinder from
overheating.
5414 394 8/2009/14
Option 1: 4-pipe system using an un-vented cylinder
®
©
@
M
Radiators
®
Boiler
©
DHW-cylinder
@
Motorisedvalve(Energycut-out)
Viessmann 4-pipe system
Note:It isrecommendedthatthe
coil output of the cylinder is greater
than 10 kW to prevent long hot water
re-heat periods.
DHW has priority.
The boiler is factory fitted with an 8 l
expansion vessel, pressure safety
valve (3 bar) and diverter valve.
If an existing or third party un-vented
cylinder is used in conjunction with
theVitodens100-Wsystemboilera
2-
port(Energycut-out)valvemaybe
fittedinthe DHW circuit. Inthis case
the2-portvalve,cylinderthermostat
andtimer has tobe electrically wired
through the provided control box
(seewiringexample).
2
5414 394
Electrical wiring example for Option 1
With existing CH/DHWprogrammer
®
Terminals in the control unit
®
Cylinderdemand terminalbox
©
Cylinder thermostat
@
Safetytemperaturesensor
®
Valve
®
Roomthermostat(clockthermo-
stat)
@
Terminalbox(onsite)
@
Powersupply230V,50Hz
3
5
@
®
©
@
@
®
5414 394
Electrical wiring example for Option 1 (cont.)
With Viessmann Vitotrol100, RF/RF2 or standard room thermostat
Terminals in the control unit
®
Cylinderdemand terminalbox
©
Cylinder thermostat
@
Safetytemperaturesensor
®
Valve
OtherViessmannsecondarycontrols
(existing programmer to be
omitted)- see separate matrix.
•
Weather compensation + 2-channel
digital timer
®
Roomthermostat(clockthermo-
stat)
@
Terminalbox(onsite)
@
Powersupply230V,50Hz
•
Vitotrol100,RF1
-
analog;DHW
time function limited (either as CH
orconstant)
•
Vitotrol100,RF2
-
digital;2-chan-
nelwithCHand DHWtime control
options.
4
5
@
®
©
@
@
®
®
5414 394
Option2:4-pipe system with open vented cylinder
Viessmann 4-pipe system with open vented hot water or with Vitocell
unventedcylinder
Radiators
®
Boiler
©
OpenventDHW-cylinderor
Vitocell
Note:It isrecommendedthatthe
cylinder coil output is greater
than 10 kW to prevent long hot water
re-heat periods.
DHW has priority.
The primary circuit is sealed system.
The boiler is factory fitted with an 8 l
expansion vessel, pressure safety
valve (3 bar) and diverter valve.
5
®
©
5414 394
Electrical wiring example for option 2
®
�
Tanksensorconnection
(sensorisoptional
-
partno.7178348)
Outside temperature sensor
(accessory)
®
OpenThermdevice
©
Connection Line (accessory)
@
Jumper(removewhenconnecting
aroomthermostat)
®
Powersupply
(230V,50Hz)
®
Vitotrol100
(room temperature ontroller)
OtherViessmannsecondarycontrols
(existing programmer to be
omitted)- see separate matrix
•
Weather compensation + 2-channel
digital timer
•
Vitotrol100,RF1
-
analog;
DHW time function limited (either
as CH or constant)
•
Vitotrol100,RF2
-
digital;
2-channelwithCHandDHWtime
control options.
6
@
X1
CN2
X21
X
7
GAS PUMP FAN
@ L N 1 L N
X20
©
�
® ®
4 3 2 1
OT
5414 394
Option3: Traditional 'Y' or 'S'-plan system (2-pipe)
Schematic Sealed Primary System
®
Radiators
®
Boiler
©
DHW-cylinder
@
Motorisedvalve
®
Pump
®
Gauge
@
Expansion vessel
@
Savetyvalve
Note: Schematic shows safety valve,
expansion vessel, pressure gauge
and pump being external of the
boiler. The Vitodens 100-W system
boiler has all these components
already factory fitted.
7
® ®
@ @
©
@
M
®
M
5414 394
Electrical wiring example
-
S-plan system with Vitodens 100-W
® ®
M
M
1-
1-
© @
L N @
S1
@
M
N
1-
L
@
@
®
L
N
1
L
N
X1
CN2
Power supply 230 V, 50 Hz
®
Timecontroller
©
Roomthermostat(clockthermo-
stat)
@
Cylinderthermostat
®
Zonevalve
®
Pump
X9 Terminals in the control unit
�
Pump connection
Viessmann Werke GmbH&CoKG
D-35107 Allendorf
Telefon:06452 70-0
Telefax: 06452 70-2780
www.viessmann.de
8
5414 394
Technische
Anderungen
vorbehalten!
Gedruckt
auf
umweltfreundlic
hem,
c
hlorfrei
gebleic
htem
P