4.3 Load mode setting
Operating Steps:
Under load mode setting interface, press SET button
begin flashing, then press MENU button
to set the parameter, press
101 Load will be on for 1 hour
since sunset 201
Load will be on for 1 hour
102 Load will be on for 2 hours
since sunset 202
Load will be on for 2 hour
Load will be on for 3~13
hours since sunset 203
~
213
114 Load will be on for 14 hours
since sunset 214
115 Load will be on for 15 hours
since sunset 215
117 Manual mode(Default load
ON) 2 n
Please set Light ON/OFF, Test mode and Manual mode via Timer1.
will be disabled and display "2 n".
4.4 Battery Type
Operating Steps
Under Battery Voltage interface, press SET button
interface of Battery type setting. After choosing the battery type by pressing
button, waiting for 5s or pressing SET
button again to modify successfully.
Battery Type
①Sealed (Default) ②Gel ③
NOTE: Please refer to the battery voltage parameters table
battery type.
5. Protections
PV Short Circuit
When PV short circuit occurs, the controller will stop charging. Clear it to resume normal
operation.
PV Reverse Polarity
Fully protection against PV reverse polarity, c
orrect the wire connection to resume
normal operation.
Battery Reverse Polarity
Fully protection against battery reverse polarity, c
orrect the wire connection to resume
normal operation.
Warning:Shock Hazard!
When the battery is reverse, the load will app
polarity voltage to battery.
Battery Over Voltage
When the battery voltage reaches to the set point of Over Voltage
charging the battery to protect the battery from being over
charged to break down.
Battery Over Discharge
When the battery voltage reaches to the set point of Low Voltage Disconnect
the controller will stop discharging the battery to protect the
discharged.
Battery Overheating
The controller detect the battery temperature through the external temperature sensor. If
the battery temperature exceeds 65ºC, the controller will automatically start the
overheating protection to stop working and recover below 50 ºC.
Load Overload
Load will be switched off when 1.05 times rated current overload happens. Controller
ill automatically attempt to reconnect load for 5 times. If overload protection still exist
after controller’s 5 times attempts, user have to
reduce load appliance, then
SET button or repower the controller or wait for one night-
hours).
Load Short Circuit
Load will be switched off when load short circuit (≥
4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
protection still exist after controller’s 5 times attempts, user have to
circuit ,then press the SET button or disconnect and restart the
controller or wait for one
night-day cycle (night time>3 hours).
Damaged Remote Temperature Sensor
If the temperature sensor is short-
circuited or damaged, the controller will be charging or
discharging at the default temperature 25 to preven℃
t the battery damaged from
overcharging or over discharged.
Controller Overheating
If the temperature of the controller heat sinks exceeds 85
automatically start the overheating protection and recover below 75
PV is protected against small high voltage surge. In lightning prone areas, additional
external suppression is recommended.
to set the parameter, press
Load will be on for 1 hour
Load will be on for 2 hour
Please set Light ON/OFF, Test mode and Manual mode via Timer1.
interface of Battery type setting. After choosing the battery type by pressing
button again to modify successfully.
NOTE: Please refer to the battery voltage parameters table
When PV short circuit occurs, the controller will stop charging. Clear it to resume normal
orrect the wire connection to resume
orrect the wire connection to resume
When the battery voltage reaches to the set point of Over Voltage
charging the battery to protect the battery from being over
When the battery voltage reaches to the set point of Low Voltage Disconnect
The controller detect the battery temperature through the external temperature sensor. If
the battery temperature exceeds 65ºC, the controller will automatically start the
Load will be switched off when 1.05 times rated current overload happens. Controller
ill automatically attempt to reconnect load for 5 times. If overload protection still exist
reduce load appliance, then
4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
protection still exist after controller’s 5 times attempts, user have to
controller or wait for one
circuited or damaged, the controller will be charging or
t the battery damaged from
automatically start the overheating protection and recover below 75
PV is protected against small high voltage surge. In lightning prone areas, additional
6. Troubleshooting
Faults
The LCD is off
during daytime when
sunshine falls on PV
modules properly
Wire connection is
correct, LCD not
display
circuit
7. Technical Specifications
Nominal system voltage
Battery input voltage
range
Rated charge current 10A
Max. PV open circuit
voltage
Temperature
compensation coefficient
Self-consumption
Charge circuit voltage drop
Discharge circuit voltage
drop
LCD temperature range
Working environment
temperature
Humidity range
Enclosure
Grounding
Overall dimension
Mounting hole size
Terminals 4mm
is working under high temperature environment,
capacity in service
Battery Voltage Parameters
(parameters is in 12V system at 25
value in 24V.)
Battery charging setting
Over Voltage Disconnect Voltage
Charging Limit Voltage
Over Voltage Reconnect Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging Voltage
Low Voltage Reconnect Voltage
Under Voltage Warning Reconnect Voltage
Under Volt. Warning Volt.
Low Volt. Disconnect Volt.
Discharging Limit Voltage
Equalize Duration
Boost Duration
8. Disclaimer
1)
Damage from improper use or use in an
PV or load current, voltage or power exceeding the rated value of controller.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice!
Confirm that PV wire connections
are correct and tight
1. Please check the voltage of
battery. At least 9V voltage to
activate the controller
2. Check the PV input voltage
which should be higher than
battery’s
Check if the battery voltage is
higher than OVD point (over
voltage disconnect voltage), and
disconnect the PV.
When the battery voltage is
restored to or above LVR point
(low voltage reconnect voltage),
the load will recover
The controller will automatically
turn the system off. But while the
temperature decline to be below
50 ºC, the controller will resume.
Short Please reduce the number of
electric equipments or check
carefully loads connection.
VS2024A VS3024A
12/24VDC Auto
9~32V
20A
30A
50V
-3mV/℃/2V(25℃)
≤8.1mA(12V);≤6.5mA(24V)
≤0.29V
≤0.16V
-20℃~+55℃
-25℃~+55℃*
≤95% (N.C.)
IP30
Common Positive
149x94.1
x46.1mm
177.5x106.6
x46.2mm
137x60mm
165.5x70mm
Φ4.5mm
is working under high temperature environment,
(parameters is in 12V system at 25
℃, please use double
Sealed Gel Flooded
16.0V 16.0V 16.0V
15.0V 15.0V 15.0V
15.0V 15.0V 15.0V
14.6V —— 14.8V
14.4V 14.2V 14.6V
13.8V 13.8V 13.8V
13.2V 13.2V 13.2V
12.6V 12.6V 12.6V
Under Voltage Warning Reconnect Voltage
12.2V 12.2V 12.2V
12.0V 12.0V 12.0V
11.1V 11.1V 11.1V
10.6V 10.6V 10.6V
120min —— 120min
120min 120min 120min
Damage from improper use or use in an
PV or load current, voltage or power exceeding the rated value of controller.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice!