Viking Electronics SLP-1 User guide

PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
COMMUNICATION & SECURITY SOLUTIONS
Add Paging to Your Existing Phone Line
Without an Expensive Phone System
Features
The SLP-1 Single Line Paging controller will
allow you to page family members or co-
workers from any phone in your home or
small office. The pages can be heard over
the same speakers that are installed for
multi-zone music distribution.
The SLP-1 connects in series with a single
existing phone line. The unit has a built-in 2
watt amplifier, pre-amp output, music on hold
input, intercom features and selectable loud
ringing. The SLP-1 provides an input for a
lighted doorbell switch, allowing a door chime
to be heard over existing speakers. Page
from several different phone lines by
connecting multiple units.
• Whole house/small business paging from existing
phones
• Built-in 2 watt mono paging amplifier with gain control
• Phone to phone intercom
• Page from several different phone lines by connecting
multiple units
• Music on hold
• Caller on hold
• Can provide background music from external source
• Background music mute (automatic during paging or
touch tone selectable while you are on a call)
• Selectable loud ring (electronic warble over speakers)
• Doorbell switch input (lighted or non-lighted) for acti-
vating door chime (ding-dong sound over speakers)
• Unique door chimes when used with a C-200, C-500,
C-1000B or C-2000B doorbox/entry phone controllers
• Switch selectable On-Hold alarm tones
• Stereo pre-amp input and line level output for use with
receivers and high wattage amplifiers
• Simple control commands: no touch tone programming
• Page trigger output (12V signal for enabling paging
source input on multi-source amps)
• Pre-amp volume control
• Bypass code: ignores all touch tones on next off-hook
allowing you to steer through auto attendants, etc.
• Comes complete with power supply
• Whole house paging from an existing phone line
• Add paging, intercom, and music on hold features for
small businesses
• Loud ringing / night bell
• Provide unique door chimes when used with a C-200,
C-500,C-1000B or C-2000B
Power: 120V AC/13.8V AC 1.25A, UL listed adapter provided
Dimensions: 5.25” x 3.5” x 1.75”1 (33mm x 89mm x 44mm)
Shipping Weight: 3 lbs (1.36 kg)
Environmental: 32°F to 90°F (0°C to 32°C) with 5% to 95%
noncondensing humidity
Paging Amplifier Output: 2 watts - powers up to (3) 8 Ohm
or (16) 45 Ohm speakers
Sound Pressure: 100 dB @ 1 meter (loud electronic warble
from 25AE paging horn)
REN: 0.5A
Maximum Speaker Output Wire Run: 91m (300 ft) maxi-
mum, 18 AWG
Maximum Doorbell Switch Wire Run: 305m (1000 ft) max-
imum, 24 AWG
Max Load on Page Trigger Output: 1K Ohm
Talk Battery: 36V DC
Connections: (1) 6-position and (1) 8-position screw termi-
nal blocks, (1) 3.5mm (1/8”) jack, (4) RCA jacks, 1.85m (6 ft)
audio cord with 3.5mm (1/8”) double ended mono plugs in-
cluded
SLP-1
Single Line
Paging Controller
November 13, 2017
Applications
Specifications
VIKING

Features Overview
DIP Switches - For on-hold alarm
and mode selections. (see page 7)
ON
OFF
1 2 3
ON
C.O. / Phone Line Input
Line Out to Phones
Speaker Output (2 watt maximum, connect
up to three 8-Ohm speakers in parallel)
Pre-Amplifier Volume Control - For paging,
loud ringing, door chime and on-hold alarm tones.
- +
Doorbell Switch Input (lighted or non-lighted) - Provides door chime over
speakers (not polarity sensitive). This input can also be connected to a
Viking model C-200, C-500, C-1000B or C-2000B for unique door chimes.
Loud Ring Enable Input (shorted: enabled, open: disabled) Provides
warble over speakers during phone line ringing.
I.O. Communications - Connect to multiple units for multi-line applications
with one amplifier (polarity sensitive).
Page Trigger Output - Connect to multi-zone amplifiers requiring a switched
12VDC signal (or dry relay contact closure) for enabling the paging source input.
Left and Right Audio Loop Input
(stereo, RCA-type) Line level pre-amp
input for background music, etc.
Music on Hold Input mono 1/8" ( 3.5mm)
Line level input from radio, etc.
Left and Right Audio Loop Output
(stereo, RCA-type) Line level output
to external amplifier.
Power Indicator LED
Page Active LED
Mute Status LED
J10 Page Trigger Contact
Closure: Remove both jumpers
and reconnect one jumper
across pins 2 & 3 to change
"Page Trigger Output" to a N.O.
relay contact.
J9 Optional Page Trigger (Dry)
Secondary relay output contacts
for controlling existing door
chimes, etc. (solder pads only,
available on top or bottom side
of PCB).
D
OOR BELL
SW. INPU
T
L
OUD RIN
G
ENABLE
-
+
I.O. COM
.
ON
1 2 3
P
WR
P
AG
E
MUT
E
PAGE TRIG. OU
T
C.O. LIN
E
INPU
T
OUT TO
P
HONE
S
-
S
PKR
+
OUTPUT
L
L
RR
-+
V
IKIN
G
©
V
IKIN
G
E
LECTRONIC
S
HUDSON, WI 5401
6
SINGLE LIN
E
P
AGING CONTROLLER
P
OWER 13.8 VAC
M
ODEL
S
LP-1
P
REAM
P
V
OLUM
E
2
WA
TT
A
A
AM
P
G
AI
N
MIN
MIN
MAX
MAX
MIN
MIN
MAX
MAX
M
USI
C
O
N
HOL
D
INPU
T
AUDIO
INPU
T
L
R
AUDIO
OUTPU
T
L
R
Internal 2 Watt (Mono) Amplifier Gain
Control - To adjust speaker output volume.
See Diagram A below
for these specifications
D
OOR BELL
SW. INPU
T
L
OUD RIN
G
E
NABL
E
-
+
I.O. COM
.
P
AG
E
T
RI
G
OU
T
-
+
Diagram A
+
-
+
-
2
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical
surges from both the AC outlet and the telephone line. It is recommended that a surge protector
be installed to protect against such surges.

Installation and Applications
A. Installation Using the Internal 2-Watt Amplifier, Stereo Receiver, Doorbell Input,
Music On Hold and Providing Optional Loud Ringing
25AE Paging
Horn (not included)
Music On Hold
Source (Radio)
13.8V AC
Adapter
(included)
120V AC
C.O. / Phone
Line
Standard
Analog Phone
To Additional Standard
Analog Phones
1/8" (3.5mm) Double Ended
Audio Cord (included)
- or -
Optional
30AE Ceiling
Speaker (not included)
Up to (3) 8-Ohm Paging Horns
or Ceiling Speakers may be connected
Doorbell Switch (lighted or
non-lighted) SPST with 6-16V bulb
Pre-Out or
* Tape Out Main In or
* Tape In
L R
Stereo Receiver
* Note: Tape monitor loop
(switch) on the stereo receiver
must be enabled (ON).
L R
"Night"
Switch (SPST) ShortedTime Controlled
Relay
- or -- or -
Optional Methods for
Enabling Loud Ringing
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
See DIP Switch
Programming (page 7)
B. Connecting to a Separate Pre-Amp and Power Amp
Music On Hold
Source (Radio)
13.8V AC
Adapter
(included)
120V AC
C.O. / Phone Line
Standard
Analog Phone
To Additional Standard
Analog Phones 1/8" (3.5mm) Double Ended
Audio Cord (included)
-
+
Main Out Input
L R L R
Pre-
Amplifier
(Background
Music Source)
Power
Amplifier
Up to (3) 8 Ohm Speakers
or Paging Horns (optional)
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
See DIP Switch
Programming (page 7)
3

Line 1
(C.O. / Phone Line)
Standard
Analog Phone
To Additional
Standard Analog
Phones
Main Out
L R
Pre-Amplifier
(Background
Music Source)
+
-
Input
L R
Power
Amplifier
To Additional
SLP-1 Units
(Up to 10 total)
Line 2
(C.O. / Phone
Line)
Standard
Analog Phone
To Additional Standard
Analog Phones
To more
SLP-1’s
(up to 10
total)
- +
or
*
Up to (3)
Optional
Speakers
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
- +
13.8V AC
Adapter
(included)
120V AC
or
4
D. Multi-Line Paging with a Single Amplifier
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
C.O. / Phone Line
Standard
Analog Phone
To Additional Standard
Analog Phones +
-
Page Input
** Multi-Zone
Controller/Amplifier
Page Trigger
(Control) Input
+
-
*Optional 12VDC or
relay contact page
trigger output
(20mA maximum)
- +
Optional Page Trigger
"Dry" Secondary Relay
Output Contacts
(1A @ 30VDC maximum)
Note: Connections to J9 require
soldering to back side of PCB.
3 2 1
N.O. COM N.C.
J9
Doorbell
Switch
Up to (3) 8 Ohm Speakers
or Paging Horns (optional)
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
13.8V AC
Adapter
(included)
120V AC
* Note: Most multi-zone controllers/amplifiers require a 12VDC trigger signal or relay contact closure to automatically switch the source to the “page” input. The SLP-1
will provide a switched 12VDC (20mA maximum) signal or relay contact closure which is maintained while the unit is paging or for the duration of the chime/ding-dong
sound (approximately 2 seconds). The SLP-1 can also provide a secondary “dry” contact page trigger output. N.O. and N.C. relay contacts are available on solder
pads J9 1-3 (see diagram above). Users often turn off all zones when they retire for the evening. In this event, we recommend dedicating up to three 8-Ohm speakers
on the SLP-1’s 2 watt speaker output. They should be placed in central locations (hallways, etc.) on each level so the door chime can be heard when all zones are dis-
abled. Caution: This connection is polarity sensitive.
** Warning: Multi-zone controllers with-
out a page trigger input (audio sensing
only) are not recommended, as the 1st
word during paging is usually omitted.
C. Connecting to the “Page” Input on Multi-Zone Controllers / Amplifiers and Controlling an
Existing Doorchime
Note: The background music mute command (#5), should not be used when connecting multiple SLP-1’s to a
single amplifier, see Operation section K, page 8.
* Note: The internal 2 watt amplifier
should only be used on the last
SLP-1 in the chain.
Caution: I.O. communications
connection is polarity sensitive.

5
E. Provide Paging, Music-On-Hold and Single Entry Phone Control
C.O. / Phone
Line Input
Analog
Phone
* Earth Ground
(optional)
Optional wiring for
door chime over
speakers. If used,
set the C-200 DIP
switch 2 to OFF. E-40-SS
Door Entry
Phone
(not included)
To Additional
Analog Phones
Page
Input
Multi-Zone
Controller/Amplifier
Page Trigger
(Control) Input
+
-
- +
DIP Switch 2
must be ON
ON
OFF
1 2 3
ON
Music On Hold
Source (Radio)
1/8" (3.5mm) Double Ended
Audio Cord (included)
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
*Optional 12VDC
page trigger
output (20mA
maximum)
EARTH
GND C.O. LINE
INPUT OUT TO
PHONES ENTRY
PHONE N.O. COM N.C.
AUX CONTACTS
ON
1 2 3
AUX POWER
OUTPUT
VIKING
POWER 13.8V AC
©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE ENTRY PHONE
CONTROLLER
MODEL C-200
RING COUNT
1
EARTH GND
1
RELAY MODE
2
DOORBELL MODE
3
IN USE
LINE IN
23
PHONES
45
ENTRY
6789
AUX POWER
OUTPUT
10 11 12
AUXILIARY
RELAY
N.O.
COM
N.C.
13.8V AC
Adapter
included
120V AC
* Note: Most multi-zone controllers/amplifiers require a 12VDC trigger signal or relay contact closure to automatically switch the source
to the “page” input. The SLP-1 will provide a switched 12VDC (20mA maximum) signal or relay contact closure which is maintained while
the unit is paging or for the duration of the chime/ding-dong sound (approximately 2 seconds). The SLP-1 can also provide a secondary
“dry” contact page trigger output. N.O. and N.C. relay contacts are available on solder pads J9 1-3 (see diagram above). Users often turn
off all zones when they retire for the evening. In this event, we recommend dedicating up to three 8-Ohm speakers on the SLP-1’s 2 watt
speaker output. They should be placed in central locations (hallways, etc.) on each level so the door chime can be heard when all zones
are disabled. Caution: This connection is polarity sensitive.
F. Provide Paging, Doorbox, and Doorstrike Control with Unique Front and Back Door Chimes
Note: To provide unique front door bell chime (ding-dong) and back door chime (ding-ding), the C-1000B must be programmed to enable
the “Auxiliary Contact Mode” (
Q
7) and have the auxiliary contact programmed for custom ring cadence (12#03). Doorbox ringing can
also be disabled by placing the C-1000B in the “Doorbell Mode” (
Q
1). See the C-1000B Technical Practice for programming details. The
C-1000B CCTV Video Control Mode can NOT be used in conjunction with unique front and back door chimes. See Operation section I,
page 7. The caller’s music on hold is limited to 5 seconds while communicating with a doorbox.
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
CONTROLLER
POWER 13.8V AC
MODEL C-1000B
PHONE LINE
INPUT
EARTH
GND
21 3 4 5 14 15 16
LINE OUT
TO PHONES
67
KEYLESS CONTACT
CLOSURE INPUT
DOORBOX 1
DOORBOX 2
891011
DOORBOX
PWR OUTPUT
12 13
DOOR
STRIKE 1
N.O.
COM
N.C.
17 18 19
DOOR
STRIKE 2
N.O.
COM
N.C.
C.O. / Phone Line
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
N.O. COM N.C.
DOOR STRIKE 1
SIG GND
VIDEO 1 IN
SIG GND
VIDEO 2 IN
SIG GND
VIDEO OUT
N.O. COM N.C.
DOOR STRIKE 2
TALK BATTERY
OFF ON
C
LED1
C
LED2
C
LED3
ON
1 2 3
COM N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
Standard
Analog Phone
To Doorstrike/
Magnetic Lock 2
To Doorstrike/
Magnetic Lock 1
To Additional
Standard
Analog Phones To Viking Doorbox 1
(Front Door)
To Viking Doorbox 2
(Back Door)
DIP Switch 2
must be ON
ON
OFF
1 2 3
ON
Up to (3) 8 Ohm
Speakers or Paging
Horns (optional)
Page Input
Multi-Zone
Controller/Amplifier
Page Trigger
(Control) Input
+
-
DOOR BELL
SW. INPUT
LOUD RING
ENABLE
- +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT
OUT TO
PHONES
- SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME
2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
*Optional 12VDC
page trigger output
(20mA maximum)
- +
13.8V AC
Adapter
(included)
120V AC
13.8V AC
Adapter
(included)
120V AC
* Note: Page trigger output can be changed to a contact closure, see “Note” in section Eabove.
Model C-1000B (DOD# 168)
For more information on
Doorboxes, see DOD 170.

VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED 2 DOOR ENTRY PHONE
CONTROLLER WITH CALL FORWARDING
POWER 13.8V AC
MODEL C-500
PHONE LINE
INPUT
LINE OUT
TO PHONES
1234
ENTRY
PHONE 1
56 789
DOOR
STRIKE 1
N.C.
N.O.
COM
ENTRY
PHONE 2
13 14
SLP
CONTROL
18
+19
TRIGGER
INPUT 1
10 11 12
TRIGGER
INPUT 2
15 16 17
DOOR
STRIKE 2
N.C.
N.O.
COM
C.O. /
Phone Line
Music On Hold
Source (Radio)
1/8" (3mm) Double Ended
Audio Cord (included)
To Optional Speakers
or Paging Horns
To "Page" input
on your whole house
audio controller
Standard
Analog
Phone To Additional Standard
Analog Phones
To Standard Analog Phones
or Viking Entry Phones
models: E-10A, E-20B, E-30,
E-40, E-50, E-60,K-1500-7,
K-1700-3 or K-1900-8.
To Doorstrike/Magnetic Lock
ON
OFF 1 2 3
ON
DIP switch 2 must
be ON (see below)
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
13.8V AC
Adapter
included
120V AC
13.8V AC
Adapter
included
120V AC
To Doorstrike/
Magnetic Lock
+ -
+ -
6
LED3
LED1 LED2 LED4 LED5 LED6 LED7 C
CCCC
C C
J11-
123
J10-
123
J9-
123
J8-
123
J7-
123
123
on
4 5
VIKING©MODEL C-2000B
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7 89
10 11 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PWR 13.8 VAC
EARTH GND
ENTRY PHONE 1
DOOR STRIKE 1
ENTRY PHONE 2
DOOR STRIKE 2
ENTRY PHONE 3
DOOR STRIKE 3
ENTRY PHONE 4
DOOR STRIKE 4
DOORBELL SWITCH /
AUX. INPUT
AUX. CONTACT
OUTPUT
PHONE LINE
INPUT
LINE OUT
TO PHONES
ANALOG STATION
INPUT
C.O. /
Phone Line
Music On Hold
Source (Radio)
1/8" (3mm) Double Ended
Audio Cord (included)
To Optional
Speakers or
Paging Horns
To "Page" input on
your whole house
audio controller
Standard
Analog
Phone To Additional Standard
Analog Phones
To Standard
Analog Phones
or Viking
Entry Phones
To Doorstrike/
Magnetic Lock
DIP switch 2
must be ON
(see Programming)
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
13.8V AC
Adapter
(included)
120V AC
* DIP switch 1
must be OFF
13.8V AC
Adapter
(included)
120V AC
G. Provide Paging with Four Unique Door Chimes and Control of Up to Four Entry Phones
and Doorstrikes from a Single Phone Line
Note: To provide unique door chimes, the C-2000B must have the “Auxiliary Contact Mode”
enabled (DIP switch 1 OFF) and have the auxiliary contact programmed for “Entry Phone
Triggered Ring Cadence Activation” (3#60). Entry phone ringing can also be disabled (0#62).
See the C-2000B Technical Practice for programming details.The caller’s music on hold is
limited to 5 seconds while communicating with an entry phone.
Door Chimes:
Entry 1 = “ding-dong”
Entry 2 = “ding-ding”
Entry 3 = “ding-ding-ding”
Entry 4 = “ding-ding-ding-ding”
H. Provide Whole House Paging, Control Up to 2 Entry Phones and Doorstrikes and Provide
Entry Phone Triggered Unique Front and Back Door Chimes from a Single Line Phone
The SLP-1 can be used with one or two Viking C-500 entry phone controllers. The phone line first runs through the SLP-1, then runs
through one or two C-500’s before continuing on to the house phones. Connect both C-500’s “SLP Control” output terminals 18 & 19 to
the SLP-1’s “Doorbell Sw Input” input (CAUTION: This connection is polarity sensitive.) When entry phones call in, the SLP-1 will play a
“ding-dong” door chime for an entry phone 1 call and a “ding ding” door chime for an entry phone 2 call, a “ding-ding-ding” chime for an
entry phone 3, and a “ding-ding-ding-ding” chime for an entry phone 4 call. To provide the 4 different door chimes, the SLP-1’s “Doorbell
Mode” DIP switch 2 must be set to ON. The C-500’s entry phone ringing can be disabled by entering 0#62 in programming. See the C-500
Product Manual for complete programming instructions (DOD 177).
* See the C-2000B Product Manual for complete programming instructions (DOD# 156).
Important: With a C-2000B as the controller, the P/N number of the SLP-1 must be 259967F or higher in order for
this application to work. If the controller is a C-2000A, the P/N number of the SLP-1 must be no higher than 259967E.

The SLP-1 can provide on-hold alarm tones to alert you that a caller has been left on hold. After each minute the
call has been left on hold, the SLP-1 will momentarily mute the background music and output a double beep tone
over the speakers. This feature can be disabled by setting DIP switch 1to OFF (see DIP Switch Programming
above).
Operation
7
Programming
A. DIP Switch Programming
Switch Position Description
1 OFF On-hold alarm disabled
1 ON
On-hold alarm tone enabled, a double
beep each minute a call is on hold
(factory default)
2 OFF Doorbell input connected to a typical
doorbell switch (factory default)
2 ON
* Doorbell input connected to a C-200,
C-500, C-1000B, or C-2000B N.O.
auxiliary contact output
3 OFF Instant outside line access (factory de-
fault)
3 ON Dial “9” to access an outside line
Paging feedback squeal can occur when phones are used in close proximity to the paging speakers. To eliminate
paging feedback, turn down the paging volume, move the phones away from the speakers or install a Viking
model FBI-1A Digital Anti-Feedback Paging Interface. For more information on installing the FBI-1A with the SLP-
1, see DOD 873.
B. Eliminating Paging Feedback Squeal
DIP Switches
(shown in factory
default positions)
ON
OFF 1 2 3
ON
DOOR BELL
SW. INPUT LOUD RING
ENABLE - +
I.O. COM.
ON
1 2 3
PWR PAGE MUTE
PAGE TRIG. OUT
C.O. LINE
INPUT OUT TO
PHONES - SPKR +
OUTPUT
LLRR
- +
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE LINE
PAGING CONTROLLER
POWER 13.8 VAC
MODEL SLP-1
PREAMP
VOLUME 2 WATT
AMP GAIN
MIN MAX MIN MAX
MUSIC
ON
HOLD
INPUT
AUDIO
INPUT
L R
AUDIO
OUTPUT
L R
Note: Place DIP switches in the desired position then
momentarily power down the unit.
* Note: This mode will provide unique chimes for each doorbox/entry phone when
used with a C-200, C-500, C-1000B or C-2000B (see Operation section I).
To page throughout the house/small business, simply press #, then 7(the letter “P” key on your keypad). Speak
into the phone receiver and your voice will be heard throughout the house or small business over the speakers.
If background music is present over the speakers, it will automatically mute allowing your page to be heard. If you
have a caller on the phone, they will automatically be put on hold. You can get the caller back by simply pressing
#8 or by momentarily hanging up. Note: The PAGE LED will light during paging.
A. Paging
To place a call on hold, simply press #then 6(the letter “O” key on your keypad), two beeps should be heard
confirming the call is on hold, then hang up. The call can then be taken on another phone elsewhere in your home
or small business. Optional Music-On-Hold can be provided.
B. Placing a Call On Hold
If you hang up the phone after placing a call on hold, simply coming off-hook with any phone will return you to the
caller on hold. If you have placed a caller on hold (#6) or have announced a page (#7) and have remained off-
hook, enter #8 or momentarily hang up to return to the caller on hold.
If the caller hangs up while on hold, the SLP-1 can sense a CPC disconnect signal and will automatically release
the line. Note: The SLP-1 has a maximum on-hold call time of 1 hour. After a caller has been on hold for 1 hour,
the SLP-1 will automatically disconnect the call.
C. Releasing a Call On Hold
D. On-Hold Alarm Tones

This feature allows you to first page someone over the speakers, then speak with them over the phone without
the conversation being heard over the speakers. To perform this function, simply press #, then 7(the “P” key on
your keypad), announce your page, then press the numeric 0key. Another phone coming off-hook will be instantly
connected.
E. Phone to Phone Intercom
The system bypass allows you to use outside phone services (automated attendants, etc.) that require the use of
the #key. Come off hook with any phone and enter #9, two confirmation beeps should be heard, hang up the
phone. The SLP-1 will now ignore all Touch Tone commands on the next off-hook.
F. System Bypass
To mute the background music any time you are on the phone, simply enter #5. The background music will return
when you enter #5 again or hang-up the phone. The MUTE LED will light while the background music is muted.
Note: The music mute command (#5) should not be used in multi-line applications.
G. Music Mute
With DIP switch 3in the OFF position (see DIP Switch Programming page 7), simply coming off-hook will instantly
give you the outside line. With DIP switch 3in the ON position, you must dial a “9” to get an outside line. The
SLP-1’s features remain the same in either mode. Note: Instant outside line access mode is for use with private
dial tone.
H. Outside Line Access Mode
With DIP switch 2in the OFF position (see DIP Switch Programming, page 7), the doorbell input terminals on
the SLP-1 can be connected to a normally open switch (lighted or non-lighted doorbell buttons, etc.). When the
switch is activated, the unit will momentarily mute the background music and provide a door chime (ding-dong)
sound over the speakers. Note: This input is not polarity sensitive and is designed to light standard 6-16V lighted
doorbell switches.
With DIP switch 2in the ON position, the doorbell input terminals on the SLP-1 can be connected to a C-200,
C-500, C-1000B or C-2000B normally open auxiliary relay contacts. When doorbox 1 on the C-1000B (or an entry
phone on a C-200) is activated, the SLP-1 will momentarily mute the background music and provide a door chime
(ding-dong) sound over the speakers. When doorbox 2 on the C-1000B is activated, a double chime (ding-ding)
will be heard over the speakers. When doorphone 1 on the C-2000B or C-500 is activated, the SLP-1 will
momentarily mute the background music and provide a door chime (ding-dong) sound over the speakers. When
door phone 2, 3 or 4 on the C-2000B or C-500 is activated, the SLP-1 will produce 2, 3 or 4 dings respectively.
This is ideal for determining which door the visitor is located at without having to answer the telephone. Note:
The C-1000B or C-2000B must have the auxiliary contact mode programmed for custom ring cadence. For more
information, refer to the C-200, C-500, 1000B or C-2000B Product Manual.
I. Door Chime (Doorbell Switch Input)
The SLP-1 can momentarily mute background music and provide loud ringing (warble sound) over the speakers
each time the incoming phone line rings. To enable this feature, short terminals labeled LOUD RING ENABLE.
This input can also be connected to a SPST switch or time controlled relay for night ring applications. Note: With
loud ringing enabled, if the incoming phone line rings during a page or phone to phone intercom, a short “loud
ring” burst will be heard over the speakers every 15 seconds or until the line stops ringing.
J. Loud Ringing
The SLP-1 is designed to operate on a single phone line. If paging is required on two or more phone lines, connect
one SLP-1 per line. Multiple SLP-1’s can be connected to the same Pre-Amp, Amp or Receiver. In this application
the terminals labeled IO COM should be connected in parallel to each SLP-1. Caution: This connection is polarity
sensitive. With the I.O. communication connected between each SLP-1, paging will be allowed on a first come,
first serve basis. If paging is active on one SLP-1, any person attempting to page on another SLP-1 will hear a
busy signal on their phone.
K. I.O. Communications (for Multi-Line Applications)
8

Quick Reference Guide
VIKING SLP-1 Quick Reference Guide
FEATURE
TOUCH
TONE
COMMAND
DESCRIPTION
Page # 7
“P” for Page. Speak into the phone and your voice
will be heard throughout the house or small busi-
ness over the speakers. Pressing #7 automatically
places a caller on hold; to return to the caller after
the page press #8 or momentarily hang-up.
Hold # 6
“O” for On-Hold. Allows you to place a caller on hold
(with music), hang up and take the call on another
phone in the house or small business.
Release
Hold
# 8 or
momentarily
hang-up
This releases the caller on hold, allowing you to con-
verse with the caller.
Phone To
Phone
Intercom
# 7 then 0
This allows you to talk with someone at another
phone in the house or small business after a page,
without the conversation being heard over the
speakers.
System
Bypass
# 9, then
momentarily
hang-up
Enter #9, hear two beeps, and hang-up. The SLP-1
will now ignore all commands on the next off-hook.
This allows you to use outside phone services (au-
tomated attendants, etc.) that require the # key.
Music
Mute # 5
This command allows you to mute the background
music coming through your speakers for the dura-
tion of an incoming or outgoing call.
Outside
Line
Access
(use only with
DIP switch 3 ON)
9
Enter 9to gain access to outside dial tone. Note:
With DIP switch 3in the OFF position, you will in-
stantly have outside line dial tone from off-hook (for
use with private dial tone).
Standard Features
Door Chime: Background music mutes and door chime (ding-dong) will be heard over the speakers.
Loud Ringing: When enabled, background music will mute and incoming call ringing (warble) sound
will be heard over the speakers for the duration of the ring.
On-Hold Alarm Tones: Each minute the call has been placed on hold, the background music will
mute and a double On-Hold alarm tone will be heard over the speakers. Note: This feature can be
disabled by setting DIP switch 1to OFF.
Make a photocopy of the Quick Reference Guide (below) and place one near
your phones for quick reference to all of the SLP-1 Touch Tone commands.
Note: Touch Tone commands are ignored during doorchimes, loud ringing and on-hold alarm tones.9

10
The C-200 allows single line telephones or a telephone system to share a phone
line with a single Viking entry phone. Tenants may answer an entry phone call and
converse with the visitor.
The C-200 provides a “Call Waiting” tone when the phone line is in use.
Tenants may call out to the entry phone for monitoring purposes. Auxiliary contacts
are provided to operate a doorbell, or activate a camera, lights, etc.
Basic Single Entry Phone Interface
• Add an entry phone to your standard
home or office phones to provide door
communication
• Provide commercial or residential secu-
rity via two-way handsfree communica-
tion at the door or gate
• Connects in series with a single phone
line or to a phone system’s unused line
input (loop start trunk input)
For more information, see DOD 169
Advanced Two Door Entry Phone Controller
with Call Forwarding and Door Strike Controls
The C-500 allows single line telephones or a
telephone system to share a phone line with
two Viking entry phones. Up to four C-500’s
can also be connected in series allowing con-
trol of up to eight entry phones and/or
doorstrikes. Tenants may answer an entry
phone call, converse with the visitor and let
them in with a touch tone command which
activates one of two relays to control a gate
or door strike.
The C-500 also has a built in five number di-
aler to call your cell phone or an outside line
if there is no answer on the inside phone. If
the outside call is busy or ring no answer, the
C-500 can call up to four more numbers.
The C-500 provides the house phones with
user programmable entry phone “Caller ID”.
Tenants may also call the entry phones for
monitoring purposes or enter touch tone
commands to activate, deactivate or toggle
the doorsrike/gate relays.
The C-500 allows up to 6 permanent keyless
entry codes, 2 “one time use” entry codes
and 1 toggle entry code for each door. The
C-500 provides optional entry phone distinc-
tive ring, two trigger inputs for “Request to
Exit” and field programmable Caller ID or
beep tones when answered to indicate which
door is activated.
For more information on the C-500, see DOD 177

11
Add One or Two Doorboxes to an Existing
Phone Line and Provide CCTV Camera Control
The C-1000B allows single line phones or phone systems to share a phone line with one or
two Viking doorboxes or paging amplifiers. The C-1000B provides two Touch Tone controlled
relays to operate door strikes or gate openers and provides doorbox triggered CCTV cam-
era switching.
Viking doorboxes and paging amplifiers can be used on single line, residential or home office
applications as well as on fully loaded systems, because they are no longer limited to instal-
lation on unused trunk ports.
• Add one or two Viking Doorboxes to your home or
office phones
• Switch between two CCTV cameras automati-
cally when either doorbox is activated
• Add a Viking SLP-1 Single Line Paging Controller
to provide paging, intercom, loud ringing, door
chime and music on hold features
• Provide commercial or residential security via two-
way handsfree communication from a door or gate
• Use as a line concentrator (one fax machine or an-
swering machine can answer three lines)
For more information, see DOD 168
Add Entry Phones and Doorstrike Control to an Existing
Line Or Securely Operate Multiple Doorstrikes
The C-2000B offers two operational modes for
flexibility in operation.
In the Single Line Ring Through Mode, the C-
2000B allows single line phones to share a phone
line with 1 to 4 entry phones. Tenants may con-
verse with visitors and activate a contact closure
to control gates or strikes. The C-2000B provides
entry phone “Caller ID” and “Call Waiting Caller ID”
and a “Call Waiting” tone when the phone line is in
use. Tenants can enter at each location by enter-
ing a keyless entry code.
In the Analog Station Dial Through Mode, the C-
2000B allows 1 to 4 entry phones to share one
analog PABX extension or telephone line and
place outgoing calls. When a remote party an-
swers, they can converse with visitors and activate
a contact closure to control gates or strikes. Mon-
itoring entry phones, forcing doorstrike relays to
operate or remote programming of the C-2000B
can be accomplished by calling the analog PABX
extension or telephone line connected. Authorized
personnel can enter at each location by entering a
keyless entry code.
In either operational mode, the secure relay control
of the C-2000B prevents the entry phone from di-
aling the activation code on the keypad of the entry
phone or using a hand held touch tone dialer. An
auxiliary input is available for connecting a lighted
doorbell switch, a common garage door opener/re-
ceiver or an auxiliary keyless entry keypad.
For more information on the C-2000B, see DOD 156

Printed in the U.S.A.
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday through Friday 8am - 5pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Product Manual in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem,
with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag,
sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or
freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued.
This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the Viking product using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to
pay a restocking charge.
DOD 478
ZF302030 Rev D
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates
and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued
to incorporate such changes.
Warranty
Product Support: (715) 386-8666
If trouble is experienced with the SLP-1, for repair or warranty information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666
If the equipment is causing harm to the telephone network, the telephone company may request
that you disconnect the equipment until the problem is resolved.
Connection to Party Line Service is subject to State Tariffs. Contact the state public utility com-
mission, public service commission or corporation commission for information.
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO
EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such
activities in the off-peak hours, such as early morning or late evenings.
It is recommended that the customer install an AC surge arrester in the AC outlet to which this
device is connected. This is to avoid damaging the equipment caused by local lightning strikes
and other electrical surges.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA.
On the side of this equipment is a label that contains, among other information, a product identifier in
the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone com-
pany.
The REN is used to determine the number of devices that may be connected to a telephone line. Ex-
cessive REN's on a telephone line may result in the devices not ringing in response to an incoming
call. In most but not all areas, the sum of the REN's should not exceed five (5.0) To be certain of the
number of devices that may be connected to a line, as determined by the total REN's, contact the
local telephone company. For products approved after July 23, 2001, the REN for this product is part
of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are
the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately
shown on the label.
The plug used to connect this equipment to the premises wiring and telephone network must comply
with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If your home has spe-
cially wired alarm equipment connected to the telephone line, ensure the installation of this SLP-1
does not disable your alarm equipment. If you have questions about what will disable alarm equipment,
consult your telephone company or a qualified installer.
If the SLP-1 causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required. But if advance notice isn't practical, the
telephone company will notify the customer as soon as possible. Also, you will be advised of your right
to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect the operation of the equipment. If this happens, the telephone company will provide ad-
vance notice in order for you to make the necessary modifications to maintain uninterrupted service.
TWO YEAR LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two
years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed
defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact
Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence
or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been
exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE
AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER,
OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED
TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEG-
LIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR RE-
PLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND
ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES
FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF
LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT
OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
12
Table of contents
Other Viking Electronics Controllers manuals
Popular Controllers manuals by other brands

AirStage
AirStage UTY-DCGG installation manual

Berker
Berker 7531 31 07 Operating and assembly instructions

Dor-O-Matic
Dor-O-Matic 96000 Series installation instructions

Zaber Technologies Inc.
Zaber Technologies Inc. NA Series user manual

Elsner
Elsner Cala KNX M-T CH Series Installation and adjustment

IBM
IBM 3270 manual

Ariston
Ariston RVS 63 operating instructions

Rosslare
Rosslare AC-A41 Installation and programming manual

MSR ELECTRONIC
MSR ELECTRONIC PolyGard 2 CGC6 user manual

Compaq Storageworks
Compaq Storageworks HSG80 quick start guide

ILX Lightwave
ILX Lightwave LDC-3700B Series user guide

Pego
Pego Vision Touch Wellness User and maintenance manual