manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vista
  6. •
  7. Power Supply
  8. •
  9. Vista VPSU1221EXTe User manual

Vista VPSU1221EXTe User manual

1
Ref: VPSU12xyEXTe
12VDC 2A/4A
WEATHERPROOF POWER
SUPPLY
VPSU12xyEXTe
2.0A (1 x 2A)
4.0A (1 x 4A)
4.0A (4 x 1A PTC Fused Outputs)
4.0A (8 x 0.5A PTC Fused Outputs)
Where x is the rated load current and yis the number of fused outputs
Thank you for choosing this high quality 12V dc power supply. Before attempting
to connect or operate this product please make sure you carefully read these
instructions for your safety.
General:
A range of 12V dc power supplies capable of delivering fully rated current to load, housed within an IP68
enclosure allowing for external use. Provided with 1, 4 or 8 individually fused outputs, they are ideal for
low powered CCTV installations.
INSTALLATION AND SET-UP
This unit is only suitable for installation as permanently connected equipment and MUST be fed from a
mains power source having a separate (approved) disconnect device - fitted with a fuse or other over-
current protection device rated at 3A maximum.
The enclosure is rated at IP68; make sure that the appropriate connections made to and from the enclosure
are to this level to retain the required IP rating for the product.
Note: The lid of the enclosure is keyedand must be in correct orientation to ensure IP68 rating.
The PSU should be installed according to all relevant safety regulations.
1) Fix to wall or other support structure using the screws/fixings supplied or use appropriate types for the
surface it is being mounted to –note IP68 enclosure mounting holes are located within the lid screw
apertures.
2) Mains input cable must be to the applicable standard with a 3A or greater current capacity, having a
minimum operating voltage of 300/500V ac.
Norbain SD Tel: +44 (0)118 912 5000
210 Wharfdale Rd, Fax: +44 (0)118 912 5001
Winnersh Triangle, Web: www.vista-cctv.com
Wokingham, Berkshire,
RG41 5TP, UK.
2
Ref: VPSU12xyEXTe
3) The low voltage output cable must be correctly sized to carry the rated load current to the devices
connected to the PSU.
4) Mains input and low voltage output cables should be routed to use different entry/exit holes in
enclosure.
5) To comply with current BS EN60950 safety legislation the supplied cable ties must be used to secure
mains input and low voltage output wiring.
OPERATION
This unit is intended for use by Service Personnel only - There are NO USER SERVICEABLE parts inside.
The green Mains LED will be illuminated whilst the mains supply is present. In the event of a fault
condition, the red Fault LED will also be illuminated on the module.
MAINTENANCE
There is no regular maintenance required of this PSU.
If the output of the PSU fails the cause of the failure should be investigated e.g. short circuit load. The
fault should be rectified before restoring power to the PSU. The fuse(s) may need to be replaced on the
single output versions. Ensure the correct fuse rating and type is used.
DISPOSAL OF PRODUCT AT END OF LIFE
This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic
Equipment (WEEE). At the end of life, the product must be separated from the domestic waste stream
and disposed via an appropriate approved WEEE disposal route in accordance with all national and local
regulations.
For more information see: www.recyclethis.info
3
Ref: VPSU12xyEXTe
SPECIFICATION
Input Specification
VPSU12xyEXTe
Voltage (rated)
100-240V ac
Voltage (operating)
90-264V ac
Frequency
50-60Hz
Mains Input Fuse (Terminal)
T2.0A HRC
Module fuse - Mains
T2.0A HRC
Max standby Power
0.5W (no load connected)
Max Mains Input Current
1.5A
Output Specification
Voltage
11.4 –12.6V dc (12V dc nominal)
Max load current
2A or 4A dependant on model
Ripple
150 mV pk-pk max
Load output Fuses
See Model Specification Table below
Overload
Electronic shutdown until overload or short circuit removed
Local Indicators
MAINS LED (Green)
Mains present
FAULT LED (Red)
Fault present: Output fuse fail
(requires load to be connected)
Fused Outputs
Model:
VPSU1221EXTe
VPSU1241EXTe
VPSU1244EXTe
VPSU1248EXTe
No. of Fused outputs:
1
1
4 x PTC
8 x PTC
Output fuse Value
F2.0A
F4.0A
1.0A
500mA
Mechanical
IP68 - Enclosure
Enclosure Dimensions
h x w x d (mm) [external]
250 x 150 x 100
Weight
1.05kg
Environmental
Temperature
-10 to +40°C (operating) 95% RH non-condensing
-20 to +80°C (storage)
4
Ref: VPSU12xyEXTe
COMPLIANCE
This product meets the essential requirements of the following EU Directives:
Low Voltage: 2014/35/EU
EMC: 2014/30/EU
RoHS2: 2011/65/EU
WEEE: 2012/19/EU
The packaging supplied with this product may be recycled.
Please dispose of packaging accordingly.

This manual suits for next models

3

Other Vista Power Supply manuals

Vista VPSU2444EXTe User manual

Vista

Vista VPSU2444EXTe User manual

Vista Viper HDA 8 User manual

Vista

Vista Viper HDA 8 User manual

Vista VPSU24VAC Series User manual

Vista

Vista VPSU24VAC Series User manual

Vista VPSU12-500e User manual

Vista

Vista VPSU12-500e User manual

Popular Power Supply manuals by other brands

Meanwell RSP-2400-12 manual

Meanwell

Meanwell RSP-2400-12 manual

KEPCO HSF 12-53M Operator's manual

KEPCO

KEPCO HSF 12-53M Operator's manual

Hi-Tec ePowerBox 30A instruction manual

Hi-Tec

Hi-Tec ePowerBox 30A instruction manual

Checkpoint TE250X Replacing

Checkpoint

Checkpoint TE250X Replacing

GOAL ZERO YETI200X user guide

GOAL ZERO

GOAL ZERO YETI200X user guide

Adel System CBI-1280 Series manual

Adel System

Adel System CBI-1280 Series manual

Abus TVAC35500 user manual

Abus

Abus TVAC35500 user manual

Meanwell DRDN20 installation manual

Meanwell

Meanwell DRDN20 installation manual

DekoLight IE-45D Product notes

DekoLight

DekoLight IE-45D Product notes

Tripp Lite PR40 Brochure & specs

Tripp Lite

Tripp Lite PR40 Brochure & specs

KEPCO EFX 100-T instruction manual

KEPCO

KEPCO EFX 100-T instruction manual

I-Tech IT7300 Series user manual

I-Tech

I-Tech IT7300 Series user manual

Vox Power NEVO+600 Series installation manual

Vox Power

Vox Power NEVO+600 Series installation manual

Corsair AX Series manual

Corsair

Corsair AX Series manual

HQ Power PS1306 quick start guide

HQ Power

HQ Power PS1306 quick start guide

Multitech PS9648 user guide

Multitech

Multitech PS9648 user guide

Powerten 3300 Series Operation manual

Powerten

Powerten 3300 Series Operation manual

KEPCO MAT FULL RACK 6V instruction manual

KEPCO

KEPCO MAT FULL RACK 6V instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.