vitapur VPS1140-1 User manual

2018-12-13
Whole Home
Ultraviolet (UV) Water
Treatment System
Maison entière
Système de filtration
d'eau ultraviolet (UV)
Sistema ultravioleta (UV)
de tratamiento de agua
para todo el hogar
SAVE THESE INSTRUCTIONS
CONSERVER CES INSTRUCTION
GUARDE ESTAS INSTRUCCIONES
VPS1140-1
Installation, Use & Care Guide
Guide d’installation, utilisation et d’entretien
Manual d uso y cuidado
YY.MAN.105

VITAPUR VPS1140-1
1. SAFETY INSTRUCTIONS ......................................................................2
2. PRODUCT OVERVIEW ........................................................................3
2.1 water quality parameters .................................................................. 4
2.2 about your system ....................................................................... 4
3. INSTALLATION INSTRUCTIONS................................................................ 5
3.1 accessibility, orientation & fittings ........................................................... 5
3.2 optional bypass line and drain valve installation.................................................. 5
3.3 in-house water distribution system disinfection .................................................. 6
4. OPERATING INSTRUCTIONS .................................................................. 7
4.1 initial start-up procedure.................................................................. 7
4.2 accredited service technician ............................................................... 7
5. SERVICE AND MAINTENANCE ................................................................ 7
5.1 lamp installation and replacement ........................................................... 8
5.2 cleaning the quartz sleeve ................................................................. 8
5.3 replacement of filter cartridges ............................................................. 9
5.4 seasonal use maintenance requirements ........................................................ 9
5.5 replacement components ordering information .................................................. 10
6. TROUBLESHOOTING GUIDE.................................................................. 10
7. MANUFACTURER’S LIMITED WARRANTY .............................................. 11
1

Congratulations on purchasing a Vitapur®UV Water Treatment System. You have taken the first step in ensuring your water is safe for yourself
and your family. This system has been deigned to disinfect your water source using UV technology, which has been proven to kill bacteria and
viruses including E. coli, Salmonella and Legionella. The Vitapur®UV System is a natural non-chemical, environmentally friendly, safe technique
for water treatment that will give you years of piece of mind.
1. Safety Instructions
The installation of this system must be in accordance with all provincial/state and/or local laws and regulations regarding plumbing and
electrical services. Installation by a certified plumber is recommended. Always comply with the following warnings and safety instructions, to
prevent bodily harm, injury or property damage.
• Do not attempt to install, operate, clean or perform routine maintenance on your VPS1140-1 system unless you have first read and
understood all of the warnings and safety instructions that are contained in this manual and on the labels that are affixed to the
VPS1140-1 system.
• Do not attempt to operate the VPS1140-1 system if it has been visibly damaged, (e.g., due to shipping) or if it may have sustained
damage, (e.g., if the unit has been dropped).
• To prevent faulty operation of the system, inspect it carefully to ensure it is free of leaks and physical damage before using.
• Never start the VPS1140-1 system, (e.g., after the initial installation) before confirming that the exterior is dry and that there are no
visible leaks.
• To prevent damage to the unit, always install the VPS1140-1 system indoors, where it will not be exposed to the elements.
• Always install and operate the unit in an environment where both the air and water temperatures will normally range between 41°F
(5°C) and 100°F (37.7°C).
DANGER: The lamp in the unit emits ultraviolet light that can cause permanent damage to skin and eyes.
Never look at the lamps when unit is operating.
• Never attempt to operate your VPS1140-1 system unless it has first been properly grounded, to avoid creating an electric shock hazard.
• To prevent an electric shock, do not plug the VPS1140-1 into any socket that has not been equipped with a Ground Fault Interrupter
(GFI). See examples below.
• Always unplug the power cord before attempting to install, clean or perform other routine maintenance on the unit.
• Always stop the inlet water flow before performing any maintenance on the unit.
• Do not attempt to service this unit unless you are an accredited service technician, as system operation could be detrimentally
affected.
• Never operate this unit in an oxygen-rich environment, or within 6 feet, (2 metres) of any oxygen source.
• Always drain all water from the unit, cap the inlet and outlet ports, and drain and disconnect all plumbing lines, if temperatures should
fall below freezing (0°C / 32°F).
15 Amp White Duplex
GFCI Outlet with Indicator Light
15 Amp White Decora Duplex
GFCI Outlet
2

3
2. Product Overview
The vitapur®Whole Home Ultraviolet (UV) Water Treatment System has been engineered to rigid standards, and has been quality inspected at
the factory prior to packaging. Please review this manual in its entirety for a detailed system explanation, and ensure that the following
components accompany this system:
Reversible
Mounting Bracket
Lamp Connection
Water Outlet (3/4" NPTM)
VuCap™
UV Lamp & Quartz Sleeve
(inside chamber) Water Inlet
Carbon Block Filter
(inside filter housing) Sediment Filter
(inside filter housing)
UV Reaction Chamber
Power Lamp
Failure
WARNING
This Product can expose you to chemicals including
Diisononyl phthalate (DINP) which is known to the State of
California to cause cancer and Mercury Compounds which is
known to the State of California to cause reproductive harm.
For more information go to www.p65Warnings.ca.gov

To ensure maximum system performance, all replacement components should be purchased directly from an authorized dealer or directly from
GHP Group inc. The use of components purchased from other sources will void the warranty, and will potentially cause the system to function in a
lesser capacity than intended.
The UV lamp and quartz sleeve should be serviced annually to ensure proper performance. Clean quartz sleeve regularly for optimum performance.
Filter cartridges should be replaced every six months, or when the pressure drop through the cartridges inhibit water flow in the home to the
point where pressure losses are being experienced.
The life of the UV lamp, quartz sleeve and filter cartridges are estimates only, and will vary dependant upon the influent water quality.
Replacement/service schedules referenced above should be a maximum, and more frequent service/cartridge replacement may be required
dependant upon your local water quality.
The VPS1140-1 is intended for the supplemental bactericidal treatment of disinfected public drinking water or other drinking water which has
been tested and deemed acceptable for human consumption by the provincial/state or local health agency having jurisdiction. The VPS1140-1 is
designed to reduce normally occurring non-pathogenic nuisance microorganisms.
If you will be using an untreated surface water or groundwater source (rather than a municipal supply source) that has been deemed
unacceptable for human consumption by the provincial/state or local health agency having jurisdiction, additional pre-treatment of the water
prior to the VPS1140-1 is required.
2.1 Water Quality Parameters
Water quality will adversely affect the performance of your Vitapur®VPS1140-1, particularly when untreated surface water or groundwater
is being used as the source of supply, if the Maximum Contaminant Levels (MCL’s) for the following six critical water quality characteristics are
being exceeded:
Iron Total iron count must be less than 0.3 ppm (0.3 mg/L)
Turbidity Count must be less than 1 NTU
Tannins Count must be less than 0.1 ppm (0.1mg/L)
Manganese Count must be less than 0.05 ppm (0.05mg/L)
Hardness Count must be less than 120 ppm (7 grains per gallon)
%UVT (transmittance) Must be greater than 75%
If you are using untreated surface water or untreated groundwater as your source of supply, the suitability of the water supply for potable
applications must be confirmed by provincial / state and/or local health agency having jurisdiction.
If the test results indicate that: (1) any of the above contaminant levels are being exceeded, or (2) any prevailing drinking water health standards
are not being met, additional pretreatment facilities must be installed that will eliminate all contaminants, which pose health risks.
2.2 About Your System
4
Specifications VPS1140-1
Rated Service Flow 30LPM / 8GPM
Unit Dimensions (L x W x H) 55.9cm/22” x 21.6cm
8.5” x 75cm/31.25”
Power Input 115V / 60Hz
Operating Pressure Range 30 - 100 PSI
Feed Water Temperature Range 40 – 99 ˚F (4 – 37 ˚C)
Unit Volume 17L / 4.5G
Ambient Temperature Range 36 – 104 ˚F (2 – 40 ˚C)
Inlet Port Size 3/4” Male NPT
Outlet Port Size 3/4” Male NPT
Minimum distance for adjacent
combustible materials 15 cm/6”

3. Installation Instructions
3.1 Accessibility, Orientation & Fittings
Always mount the VPS1140-1 in a location that provides ample space for accessing the ultraviolet lamps. Service may require removing the
UV lamp and quartz sleeve. A minimum of 18”, (45 cm) of clear space should be provided on either the left or right side of the unit based on the
direction of installation of the UV lamp. As the VPS1140-1 generates heat during use, please ensure that no combustible items come into
contact with, or are in proximity to the system.
It is recommended that you maintain at least 6” (15 cm) of clear wall space on all sides of the VPS1140-1 for cooling purposes. This will prolong
the operating life of the system.
CAUTION: Whenever soldering is required on any VPS1140-1 system component, always detach that component from the system first.
3.2 Recommended Bypass Line and Drain Valve Installation
WARNING: To prevent contamination of water in the plumbing, which may pose a health hazard, do not use bypass line and valve if your source
of supply is untreated surface water or groundwater.
If your source of supply is treated municipal water, use of the bypass line and valve will permit uninterrupted treated water service in the event
of system malfunction.
Always test the bypass valve following each use of the bypass line, prior to re-starting the VPS1140-1 to confirm that the valve has been fully
closed and that only water from the outlet port will thereafter be going downstream.
The installation of a drain valve, while not required for system operation, is recommended for all installations of the VPS1140-1. The installation
of a drain valve will allow the service technician to drain the system of water prior to conducting any service on the unit.
A bypass system for the VPS1140-1 can be installed as outlined below:
BYPASS LINE SETUP DIAGRAM
5
Please note that the VPS1140-1 is not equipped with a
bypass valve system when purchased. The addition of a
bypass valve system is at the discretion of the user. All
plumbing components must be purchased separately.
«Mounting Bracket allows for a reversible
installation if preferred
Bypass valve
Outlet valve
Inlet valve

6
3.3 In-House Water Distribution System Disinfection
The following procedure is recommended for non-municipally supplied water installations of the VPS1140-1 system. For systems
installed on a municipal water system, plumbing system disinfection is at the discretion of the user.
The entire household water system, between the VPS1140-1 and your taps and water outlets, MUST be sterilized before system start up in
order to destroy any residual contamination. The same treatment can also be completed at any time in the future that untreated water is
allowed into your distribution system (e.g. through an inadvertent by-pass, plumbing additions or repairs, etc.) or in the case of seasonal dwell-
ings at the beginning of each operating season.
Unscented household bleach (5% sodium hypochlorite) is an acceptable decontaminant when used at the rate of 1 liter, (0.3 gallons) of bleach
per 1000 liters, (264 gallons) of household plumbing volume. This includes the volume of water contained in all lines, hot water tanks, etc.
located 'downstream' of the filter housings. This ratio provides a dosage of 50 mg / L or 50 ppm, which is sufficient for disinfection.
To disinfect the distribution system, carry out the following steps (please ensure that the UV System remains on during the
entire process):
1. Familiarize yourself with the various shut-off valves on your system. It is important to understand which combinations of valve
positions allow you to isolate the VPS1140-1.
2. Shut the main water supply off and drain the hot water tank and any other storage tanks that may be downstream of the filter
housing.
3. Close the valves necessary to isolate and remove the Carbon Block filter cartridge from the housing with the wrench provided.
Remove the filter housings using the wrench provided with the system. Pour 1-2 cups of household bleach into the carbon filter
housing and reattach to the filter cap. Remember to leave the carbon filter out during chlorination.
4. Re-install the filter housing (without filters). Make sure that the housings are seated properly against the filter heads. Re-open
water lines, checking to ensure there are no leaks.
5. Go to the furthest tap in the house and run the cold water until you notice the odor of bleach. Repeat this step at all other taps,
including washing machine, shower heads and toilets.
Caution: The above procedure (steps 1-5): The addition of Chlorine (Bleach) to a hot water tank that has in the past been
fed with untreated raw water with high levels of contaminants (iron, manganese, hydrogen sulfide, organics, etc) will
result in oxidation of these contaminants and may require repeated flushing of the hot water tank. This contingency must
be dealt with independently under the start-up procedure.
6. Allow the solution to remain in the lines for 30 minutes.
7. Remove the filter housings with the wrench provided with the system. Re-insert both the Sediment and Carbon Block filters into
their housings and attach them to the system. Make sure that the housings are seated properly against the filter heads.
8. Slowly open up the main water lines and check the system for any leaks.
Caution: It is critical to ensure that the water distribution system is fully flushed of all residual chlorine prior to use.
EXTREME CAUTION SHOULD BE EXERCISED, as the level of chlorine in the system is approximately 25-50 times greater
than that observed in municipally treated water (this is required for the disinfection of the household lines). It is
extremely important that proper flushing procedures be followed for all taps prior to use.

4. Operating Instructions
4.1 Initial Start-Up Procedure
The VPS1140-1 system has been designed to be installed on the cold water line only.
NOTE: The UV System should remain on continuously to ensure protection of your water system. During normal operation of the system, the
green power LED will be illuminated. When there is no flow in the system, the water in the vitapur®chamber will be warmed by the ultraviolet
lamps. Running a cold water tap for about 30 seconds will eliminate all of the warm water.
The presence of small air bubbles in the water system may occasionally give tap water a milky appearance, but air bubbles will not affect water
quality or taste. Initially, filtered water may appear cloudy due to the release of air trapped within the filters and throughout the system.
Dependant upon your use of the system, this condition should disappear within a few days to a few weeks following system installation.
Always perform the following start-up procedure when starting your VPS1140-1 system for the first time or after a dormant period:
1. Shut off the main water supply valve.
2. Mount the UV rack system to the wall. Please note that due to the weight of the UV rack, it is essential that the unit is mounted
directly to a concrete wall (screws and washers not provided) or directly into framing studs (screws and washers provided).
Do not mount the unit directly on dry wall.
3. Hook up inlet water connections and the outlet water connection. For ease of installation and service it is
recommended using couplings on both the inlet and outlet lines.
4. The filters are wrapped and the wrapping around the filter(s) has to be removed. Mount the filter(s) and housing(s) on the
UV rack system.
5. Plumb inlet water connections and the outlet water connection. For ease of installation and service it is recommended using
union couplings on both the inlet and outlet lines.
6. Confirm that all of the plumbing connections are secured. Partially open the main supply valve while releasing air from the
system by opening a downstream faucet.
7. Plug in the Vitapur UV disinfection system and confirm that the UV lamp is illuminated; (purple glow through the VuCap®).
8. If no leaks are visible at low flow, then fully open the main supply valve. Check for leaks.
9. For chlorine disinfection of household water distribution system, follow procedures outlined in section 3.3.
10. Open a downstream tap and flush the system for 15 minutes prior to initial use.
11. Your UV rack system is now ready for use.
The following instructions have been provided to assist with general maintenance of the system; UV lamp replacement and quartz sleeve
cleaning/replacement. All other system repairs must be completed by an accredited service technician.
5. Service and Maintenance
Your VPS1140-1 uses a dual treatment process involving both filtration and UV disinfection to treat water. The water filters, quartz sleeve and
ultraviolet lamp require regularly scheduled replacement / service in order for the VPS1140-1 to provide maximum performance.
The ultraviolet lamp has an approximate life of 9000 hrs. (one year). Replacement UV lamps and quartz sleeves are available from an authorized
retailer and GHP Group inc. Use only vitapur®lamps and sleeves to ensure maximum system performance. Replacement lamp and quartz
sleeve model # VUVL-8
Your vitapur®UV disinfection system in equipped with a visible/audible lamp failure indicator. In the event of a failure of the UV lamp, the red
LED light will flash and a loud beeping will be audible. Please note that if these conditions occur and you are on a non-municipal supplied water
source, you should immediately stop using the water for potable applications until the lamp is replaced and disinfection of the distribution lines
is completed.
7

8
5.1 Lamp Installation and Replacement
WARNING: The lamp heats up after continuous use and can burn your skin if touched. Allow lamp to cool for at least 5 minutes before removing.
DANGER: Do not operate the UV lamp outside of the reactor. The lamp in the unit emits Ultraviolet light that can cause permanent damage to
skin and eyes. Never look at the lamp when unit is turned on.
Handle the UV lamp by the ends only. Do not touch the bulb of a lamp with your fingers. If the surface of the lamp becomes dirty, use a clean
lint-free cloth to remove the dirt.
Procedure for Replacing / Installing the Ultraviolet (UV) Lamp:
1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. Allow at least 5 minutes for lamp to cool.
4. Remove the connector from the end of the UV lamp.
5. Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only by the ceramic tips.
6. Insert the new UV lamp into the quartz sleeve and attach the connector.
7. Slowly open water supply and check the system for leaks.
8. Plug in unit and ensure that the UV lamp is operating. A purple glow should be visible through the VuCap®.
5.2 Cleaning the Quartz Sleeve
Mineral deposits and sediment build-up on the quartz sleeve will affect system performance by decreasing the UV light transmitted through the
quartz sleeve into the water column.
The proper maintenance and replacement of the Sediment and Carbon Block filters supplied with the VPS1140-1 system will reduce the
accumulation of mineral and sediment residue on the quartz sleeve.
The quartz sleeve may be cleaned with a commercially available, non-abrasive, scale remover and a lint free cloth. Cleaning of the quartz sleeve
should be done on a regular basis to ensure maximum system performance. The amount of cleaning required will be dependant upon local
water conditions.
All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system. Care should be taken to prevent
any cleaning fluid from coming into contact with the inside surface of the quartz sleeve.
Procedure for Removing / Installing the Quartz Sleeve:
1. Turn off the water supply at the inlet valve.
2. Unplug the unit.
3. Drain water from the Stainless Steel UV Chamber.
4. Allow at least 5 minutes for lamp to cool.
5. Rotate VuCap® counter-clockwise to allow for UV lamp removal.
6. Remove the connector from the end of the UV lamp.
7. Remove the UV lamp from the quartz sleeve. Be sure to hold the UV lamp only by the ceramic tips.
8. Remove quartz sleeve retaining nut and O-ring from the quartz sleeve.
9. Remove the quartz sleeve and clean as noted above. A final wipe down with isopropyl alcohol will remove any cleaner residue.
10. Insert quartz sleeve into the UV chamber.
11. Place O-ring onto quartz sleeve and then tighten retaining nut hand tight to ensure a water tight seal.
12. Insert new or old UV lamp into the quartz sleeve and attach the connector from ballast to the UV lamp. Then attach the VuCap®
head to the VuCap® base by turning a quarter turn clockwise.
13. Refill the UV chamber slowly by opening the water supply just enough to fill the chamber with water.
14. Check the system for leaks. If no leaks appear, fully open the inlet water valve.
15. Plug in power to ballast.
16. Ensure that the UV lamp is operating. A purple glow should be visible through the VuCap®

5.3 Replacement of Filter Cartridges
Filter cartridge life varies depending on usage and/or water conditions. Changes in taste, color, and flow of the water being filtered indicate that
the cartridge should be replaced. It is recommended that the filter cartridges be replaced every 6 months. Replace sooner if water pressure at
faucet begins to drop noticeably or cartridge fails to perform satisfactorily.
WARNING: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after
the system.
Procedure for replacing filter cartridge:
1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. Depress the red pressure relief buttons on both filter housings, (a small amount of water may come out of the release valve
when the pressure is released, this is normal).
4. Place a pail under the filter housing to catch any water during filter removal.
5. Using the filter housing wrench, loosen the filter housing.
6. When the filter housings, is turning freely, hold onto it with both hands while backing the housing off the threads. The housing,
filled with water and a wet filter is heavy, be cautious and ensure that you are adequately positioned to support the weight.
7. Remove the old filter, and dispose in the trash. Used filters are not considered hazardous waste.
8. Empty the housing of water, clean filter housing if stained, and insert the new filter cartridge. Make sure the o-ring on the filter
housing has not fallen off the housing when dumping the excess water or removing the old filter.
9. Attach the filter housing onto the system.
10. Tighten the filter housing back into position lightly with your hands. Use the wrench to ensure a good seal, although caution should
be taken to ensure the housing is not over tightened.
11. Slowly refill the system by opening the inlet water line just enough to fill the chamber with water.
12. Check the system for leaks.
13. If no leaks are evident, open the inlet water line completely and re-check for leaks.
14. Plug the system in and ensure that the UV lamp is operating.
15. Open the water supply line from the system.
16. Flush the system for a minimum of 5 minutes prior to use.
5.4 Seasonal Use Maintenance Requirements
If your system is only being used seasonally, it must be stored properly for the winter. Drain all water from the system and disconnect it from
the power source. Cap both the inlet port and the outlet port, to prevent entry of insects and small animals.
Remove the filters from the system and discard in the trash.
Before placing the system back in service, it is recommended that the household plumbing procedures described in section 3.4 be followed and
that the entire plumbing network be fully disinfected and flushed prior to using the VPS1140-1 system.
Install new filters in the system, (see section 5.3). Do not re-install filters used during the previous season.
To clean any dust build up and/or dirt on the outside of the Quartz Sleeve, use a lint-free cloth with alcohol or non-abrasive scale remover.
9

Problem Possible Cause Suggested Solution
Pressure Drop
(More than 40 psi loss at
8GPM).
Prefilter(s) clogged. Replace filter cartridge.
Warm Output Water. Water sitting in VPS1140-1 and heating up due to
infrequent use.
Run tap for short time.
VPS1140-1 leaking water. Misaligned or cross-threaded ports (inlet or outlet).
Excessive water pressure (beyond 80 psi).
Water Hammer causing pressure spikes.
Installed on the system without a pressure relief device.
Reinstall to ensure a good solid connection with ports.
Install pressure regulator ahead of system.
Install a Water Hammer* Arrestor in system.
No power to UV lamp when
system is plugged in.
GFI wall socket is tripped. Reset, following instructions provided with that device.
Check socket with other appliances.
System has power but UV
lamps not coming on.
Lamps not installed correctly. Check to see that the lamp is installed correctly and not
loose.
Water is milky. Small air bubbles are trapped in water.
Air purging from new filters / system.
Leave tap on for short time.
Find source of air bubbles and correct (flush more).
System is Vibrating. Not mounted securely.
Water Hammer* causing vibrations.
Secure fasteners.
Install a Water Hammer* Arrestor in system.
Excessive heat generated. Not being allowed sufficient space for cooling.
Operated in an excessive ambient temp.
Water temp too high.
Clear space for cooling. (see section 2.4 for details).
Unplug unit until temp. is lower than maximum rated
ambient air conditions.
Water temp. is higher than 37.7oC / 99.9oF.
Outlet water has bad taste. Filters not installed.
Filter(s) / Housing(s) not seated properly.
Testing / source identification / additional pre-treatment
may be required.
Ensure filters are in position.
Ensure filters are correctly seated in the housing, and the
housings are seating properly.
Testing should be conducted to determine cause of bad
taste. Additional pre-treatment may be required.
6. Troubleshooting Guide
10
5.5 Replacement Components Ordering Information
Please contact the Customer Service Department : 1-866-253-0447 If additional replacement component items are required, please contact the
Customer Service Department.
Part Description Quantity Per Unit Part #
Sediment Filter 1 VS20RF-PP
Carbon Block Filter 1 VS20RF-CTO
UV Lamp & Quartz Sleeve 1 VUVL-8
* Water Hammer: Sudden closure of a control valve or stopping of a pump produces excess pressure in a pipeline. The hydraulic engineer, water supply designer and pumping
system operator have the responsibility to ensure the surges due to Water Hammer are within acceptable limits and can be dampened as quickly as possible.
Note: If you experience trouble with your system other than the symptoms described above, please visit www.ghpgroupinc.com, or contact
the Customer Service Department at 1-866-253-0447.

Retailer: Model Number:
Serial Number: Purchase Date:
DO NOT RETURN THIS PRODUCT TO THE STORE:
Please contact Customer Service at: 1-866-253-0447
Definitions:
GHP Group inc: Manufacturer
UV Water Treatment System: VPS1140-1 UV water treatment system manufactured by GHP Group inc
Purchaser: Purchaser of the UV water treatment system
Distributor: Facility authorized to sell GHP Group inc Systems
Warranty Card: GHP Group inc Limited Warranty registration card identifying the purchaser
GHP warrants to the Purchaser that the UV water treatment system is free from defects in material and workmanship, under normal use
and service, for 1 year (limited parts) from the date of purchase.
This warranty shall be fulfilled by an authorized GHP Repair Facility. All warranty repairs must be pre-authorized by GHP Group inc. GHP
will, at its option, replace or repair free of charge any defective part, which the Purchaser shall notify their Distributor
or GHP Group inc within the warranty period. The obligation of GHP Group inc under this warranty is expressly limited to such replace-
ment of repairs.
The provisions of this limited warranty shall not apply to the following:
1. Accidents.
2. Unauthorized repairs or alterations.
3. Normal maintenance.
4. Changes made to other units manufactured after this UV water treatment system was manufactured.
5. Incidental damages caused by failure of the UV water treatment system such as water damage, inconvenience, loss of use.
6. Improper operation.
7. Improper installation.
The provisions of this limited warranty shall not apply to deterioration due to wear and exposure beyond the following limitations.
1. For 6 months from the date of purchase for UV lamps.
2. For 6 months from the date of purchase for Quartz Sleeves.
3. For 1 year from the date of purchase on electrical components and circuit boards.
4. For 1 year from the date of purchase on filter housings, connections, and stainless steel reaction chamber.
Water filters provided with the UV water treatment system are exempt from warranty coverage as variations in local water conditions will
directly affect the overall lifetime for these components.
GHP Group inc Limited Warranty is void unless the following conditions are adhered to:
1. Warranty registration must be completed within 30 days and returned to GHP Group inc.
2. All warranty repairs must be pre-authorized.
3. GHP reserves the right to inspect defective parts that have been replaced under warranty. Dealer is required to hold defective
parts for 60 days.
4. Only parts and accessories and other material, available through GHP Group inc are to be used in the performance of
warranty service.
5. Purchasers are responsible for presenting/notifying their Distributor as soon as a problem exists. The warranty repairs should be
completed in a reasonable amount of time from the date of authorization. Not to exceed 30 days past notification.
GHP Group inc or GHP approved replacement components purchased for annual routine maintenance or other parts purchased for
replacement of product components which are no longer covered in the original warranty, excluding replacement filter cartridges, are
warranted to be free of defects in material and workmanship for a period of 3 months from the date of purchase. GHP will, at is option,
replace or repair free of charge any defective part which the Purchaser shall notify their Distributor or GHP Group inc within the replace-
ment component warranty period. The obligation of GHP Group inc under this warranty for
replacement components is expressly limited to such replacement and repairs subject to the provisions detailed above.
This limited warranty is expressly in lieu of any other expressed or implied warranty, including any implied warranty or merchantability
or fitness for a particular purpose and of any obligations or liabilities on GHP Group inc which neither assumes nor authorizes any other
person to assume for it any other liability in connection with the UV water treatment system manufactured by it.
The warranty is null and void if used in commercial or industrial applications.
Limited Warranty:

12
VITAPUR VPS1140-1
1. CONSIGNES DE SÉCURITÉ ...................................................................................................................................... 13
2. APERÇU DU PRODUIT ............................................................................................................................................. 14
2.1 PARAMÈTRES DE QUALITÉ DE L'EAU ......................................................................................................................... 15
2.2 À PROPOS DE NOTRE SYSTÈME ................................................................................................................................ 16
3. DIRECTIVES D'INSTALLATION ............................................................................................................................... 16
3.1 ACCESSIBILITÉ, ORIENTATION ET RACCORDS................................................................................................................ 16
3.2 INSTALLATION FACULTATIVE D'UNE CONDUITE DE DÉRIVATION ET D'UN ROBINET DE VIDANGE.................................................. 16
3.3 DÉSINFECTION DU SYSTÈME D'ALIMENTATION EN EAU DE VOTRE DOMICILE........................................................................ 17
4. CONSIGNES D'UTILISATION................................................................................................................................... 18
4.1 DÉMARRAGE INITIAL ............................................................................................................................................... 18
4.2 TECHNICIEN D'ENTRETIEN AGRÉÉ............................................................................................................................... 19
5. SERVICE ET ENTRETIEN......................................................................................................................................... 19
5.1 INSTALLATION ET REMPLACEMENT DE LA LAMPE ......................................................................................................... 19
5.2 NETTOYAGE DU MANCHON DE QUARTZ....................................................................................................................... 19
5.3 REMPLACEMENT DES CARTOUCHES FILTRANTES.......................................................................................................... 20
5.4 DIRECTIVES D'ENTRETIEN POUR UNE UTILISATION SAISONNIÈRE ...................................................................................... 20
5.5 COMMANDE DE PIÈCES DE RECHANGE ....................................................................................................................... 20
6. GUIDE DE DÉPANNAGE .......................................................................................................................................... 21
7. GARANTIE LIMITÉE DU FABRICANT ........................................................................................................................22

13
Merci d'avoir acheté le système vitapur® de traitement de l'eau par UV. Vous avez franchi la première étape vers l'assurance que votre famille
consomme de l'eau vraiment saine. Ce système a été conçu pour désinfecter l'eau provenant de votre source d'approvisionnement en recourant
à une combinaison éprouvée de technologie et de rayons ultraviolets pour éliminer les bactéries et les virus qui s'y trouvent, y compris les
colibacilles, la salmonelle et la légionnelle. Le système vitapur® est une technique d'épuration naturelle, non chimique, écologique et sécuritaire
qui vous permettra d'avoir l'esprit en paix pendant de nombreuses années.
1. Consignes de sécurité
Ce système doit être installé conformément à l'ensemble des lois et des règlements qui régissent les travaux de plomberie et les services
électriques dans votre province, votre région ou votre État. Nous vous recommandons de retenir les services d'un plombier agréé pour installer
cet appareil. Respectez en tout temps les consignes de sécurité et les avertissements mentionnés qui suivent pour éviter de vous blesser ou
d'endommager vos biens.
• Vous devez avoir lu et compris toutes les consignes de sécurité et tous les avertissements qui se trouvent dans ce manuel et sur les
étiquettes apposées sur votre système VPS1140 avant de tenter de l'installer, de l'utiliser, de le nettoyer ou d'en effectuer l'entretien de
routine.
• Ne tentez pas d'utiliser votre système VPS1140 si vous constatez qu'il a été abîmé (p.ex. durant le transport) ou si vous soupçonnez
qu'il pourrait avoir été endommagé (p.ex. si l'appareil a été échappé).
• Pour éviter tout mauvais fonctionnement de l'appareil, inspectez-le soigneusement pour vous assurer qu'il n'y a pas de fuite ou de
dommages matériels avant de l'utiliser.
• Ne mettez jamais le système VPS1140 en marche (p.ex. après son installation initiale) sans d'abord vous assurer que sa paroi
extérieure est sèche et qu'il n'y a aucune fuite apparente.
• Pour éviter d'endommager votre système VPS1140, installez-le toujours à l'intérieur, à l'abri des intempéries.
• Installez et utilisez toujours l'appareil dans un environnement où la température de l'air et celle de l'eau varient normalement entre
41°F (5°C) et 100°F (37,7°C).
DANGER : La lampe de cet appareil émet des rayons ultraviolets qui peuvent causer des dommages permanents à la peau et aux yeux.
Ne regardez jamais la lampe pendant que l'appareil est en marche.
• Pour éliminer les risques d'électrocution, n'allumez jamais votre système VPS1140 avant de l'avoir mis à la terre correctement.
• Pour prévenir les chocs électriques, ne branchez pas le VPS1140 dans une prise qui n'est pas dotée d'un interrupteur de défaut à la
terre (GFI). Voir les exemples ci-dessous.
• Débranchez toujours le cordon d'alimentation avant de tenter d'effectuer l'installation, le nettoyage ou l'entretien de routine de
l'appareil.
• Fermez toujours l'alimentation en eau avant d'effectuer l'entretien de l'appareil.
• À moins d'être un technicien d'entretien agréé, ne tentez pas de réparer l'appareil vous-même, car vous risqueriez de compromettre
l'efficacité du système.
• Ne faites jamais fonctionner cet appareil dans un milieu riche en oxygène ou dans un rayon de 6 pieds (2 mètres) d'une source
d'oxygène.
• N'oubliez pas de toujours vider l'appareil de son eau, de boucher les orifices d'entrée et de sortie d'eau et de vider et de débrancher
tous les tuyaux de plomberie lorsque la température descend sous le point de congélation (0°C ou 32°F).
Duplex Blacn 15 Amp
Sortie avec Indicateur lumineux GFCI
Decora Duplex Blanc 15 Amp
Sortie GFCI

14
2. Aperçu du produit
Le système vitapur® de traitement de l'eau par UV pour la maison entière a été conçu selon des normes rigoureuses et a subi un contrôle de
qualité avant d'être emballé. Veuillez lire ce guide en entier pour obtenir des explications détaillées sur le système. Assurez-vous également que
les pièces suivantes accompagnent bien votre appareil :
Support de montage
réversible
Raccord lampe
Sortie d’eau (3/4 po NPTM
— tuyau filetage mâle)
VuCap™
Lampe UV et douille
en quartz (dans la chambre) Entrée d’eau
Filtre à carbone
(dans le boîtier à filtre) Filtre à sédiments
(dans le boîtier à
filtre)
Chambre de
réaction UV
Alimentation Défaillance
de la lampe
AVERTISSEMENT
Ce produit peut vous exposer à des substances chimiques comme le phtalate
de diisononyle (DINP), qui est reconnu par l’État de Californie comme causant
le cancer, ainsi qu’à des composés du mercure, qui sont reconnus par l’État
de la Californie comme causant des problèmes de reproduction.
Pour plus de renseignements, visitez le www.p65Warnings.ca.gov

15
Pour assurer le rendement maximal du système, achetez toutes les pièces de rechange dont vous aurez besoin chez un distributeur agréé ou
directement chez GHP Group inc. L'utilisation de pièces vendues par d'autres fournisseurs annule la garantie et risque de nuire au rendement du
système.
La lampe à rayons UVA et le tube de quartz ont besoin d'être entretenus chaque année pour maintenir un niveau de fonctionnement adéquat.
Nettoyez le manchon de quartz régulièrement pour obtenir un rendement optimal.
Les cartouches filtrantes devraient être remplacées tous les six mois ou dès que la perte de charge subie par l'eau en traversant les cartouches
ralenti suffisamment le débit d'eau dans la maison pour créer un problème de diminution de pression.
La durée de vie utile de la lampe à rayons UVA, du tube de quartz et des cartouches filtrantes est approximative et varie selon la qualité de l'eau
influente. Les délais de remplacement ou d'entretien susmentionnés devraient être considérés comme des maximums. Selon la qualité de l'eau
dans votre région, vous pourriez devoir effectuer l'entretien de l'appareil ou le remplacement des cartouches plus fréquemment.
Le VPS1140-1 est conçu pour le traitement bactéricide supplémentaire de l'eau potable publique déjà désinfectée ou d'autres types d'eau potable
qui ont été analysés et déclarés propres à la consommation humaine par un organisme de santé compétent de la région, de la province ou de
l'État. Le VPS1140-1 vise à réduire les taux de micro-organismes non pathogènes et nuisibles présents normalement.
Si vous utilisez de l'eau de surface ou une source d'eau souterraine non traitée (au lieu d'une source d'approvisionnement municipale) qui a été
déclarée propre à la consommation humaine par un organisme de santé compétent de la région, de la province ou de l'État, vous pourriez devoir
soumettre votre eau à un traitement préalable avant de la désinfecter à l'aide du VPS1140-1.
2.1 Paramètres de qualité de l'eau
La qualité de votre eau peut nuire au rendement de votre vitapur®VPS1140-1, particulièrement si vous utilisez de l'eau de surface ou de l'eau
souterraine non traitée comme source d'approvisionnement et si cette eau contient un ou plusieurs des six éléments principaux qui altèrent la
qualité de l'eau en quantité supérieure aux taux de contaminants maximaux (TCM) recommandés :
Fer La concentration totale en fer doit être inférieure à 0,3 ppm (0,3 mg/L)
Turbidité La concentration doit être inférieure à 1 uTN
Tanin La concentration doit être inférieure à 0,1 ppm (0,1 mg/L)
Manganèse La concentration doit être inférieure à 0,05 ppm (0,05mg/L)
Dureté Le taux doit être inférieur à 120 ppm (7 grains par gallon)
% UVT (transmittance) La transmittance doit être supérieure à 75 %.
Si vous utilisez de l'eau de surface ou de l'eau souterraine non traitée comme source d'approvisionnement, elle doit être déclarée potable par un
organisme de santé compétent de la région, de la province ou de l'État.
Si les résultats des analyses indiquent que (1) le niveau d'un des contaminants susmentionnés dépasse les limites maximales ou que (2) votre
eau ne satisfait pas aux normes sanitaires actuelles concernant l'eau potable, vous devrez mettre en place des installations de traitement
préalables pour éliminer les contaminants qui présentent des risques pour la santé.
2.2 À propos de notre système
Spécifications VPS1140-1
Débit nominal d'utilisation 30LPM / 8GPM
Dimensions de l'appareil (L x L x H) 55.9cm/22” x 21.6cm
8.5” x 75cm/31.25”
Puissance consommée 115V / 60Hz
Pression d'utilisation 30 - 100 PSI
Température de l'eau d'alimentation 40 – 99 ˚F (4 – 37 ˚C)
Volume de l'appareil 17L / 4.5G
Température ambiante 36 – 104 ˚F (2 – 40 ˚C)
Taille de l'orifice d'entrée 3/4” Male NPT
Taille de l'orifice de sortie 3/4” Male NPT
Distance minimale pour les matériaux
inflammables 15 cm/6”

16
3. Directives d'installation
3.1 Accessibilité, orientation et raccords
L'emplacement où votre VPS1140-1 est installé doit vous permettre d'accéder aux lampes UV facilement. Au moment de l'entretien de l'appareil,
vous devrez peut-être retirer la lampe UV et son manchon de quartz. Pour ce faire, vous aurez besoin d'un minimum de 18 po (45 cm) d'espace
libre du côté gauche ou du côté droit de l'appareil, selon les directives d'installation de la lampe UV. L'utilisation du VPS1140-1 produit de la
chaleur. Veillez à ce qu'aucun article inflammable ne soit placé près du système ou n'entre en contact avec celui-ci.
Il est recommandé de garder environ 6 po (15 cm) d'espace libre par rapport au mur autour du VPS1140-1 pour faciliter son refroidissement. Ceci
prolongera la durée de vie utile du système.
AVERTISSEMENT : Si vous devez souder certains éléments du système VPS1140-1, retirez-les de l'appareil avant de les souder ensemble.
3.2 Installation facultative d'une conduite de dérivation et d'un robinet de vidange
AVERTISSEMENT : Pour éviter la contamination de l'eau dans la tuyauterie et la création d'un danger pour la santé, ne posez pas de conduite ou
de robinet de dérivation si vous utilisez de l'eau de surface ou de l'eau souterraine non traitée comme source d'approvisionnement.
Si votre municipalité vous approvisionne en eau traitée, la conduite et le robinet de dérivation vous garantiront un accès ininterrompu à une
source d'eau traitée en cas de défaillance du système.
Après chaque utilisation de la conduite de dérivation et avant de redémarrer le VPS1140-1, assurez-vous toujours que le robinet de dérivation est
complètement fermé pour que seule l'eau provenant du raccord de sortie s'écoule en aval.
L'installation d'un robinet de vidange est recommandée pour tous les systèmes VPS1140-1, bien qu'elle ne soit pas essentielle à leur
fonctionnement. Le robinet de vidange permet au technicien d'entretien de vider le système avant de réparer l'appareil.
Un système de dérivation peut être ajouté au VPS1140-1 tel que l'illustre le diagramme ci-dessous.
DIAGRAMME D'INSTALLATION DES CONDUITES DE DÉRIVATION
Veuillez noter qu'au moment de l'achat, le VPS1140-1
n'est pas doté d'un système de dérivation. L'ajout d'un
tel système est à la discrétion de l'utilisateur. Toutes les
pièces de plomberie doivent être achetées séparément.
«Le support de montage permet des installations
réversibles si besoin.
Robinet de dérivation
Robinet de sortie
Robinet d'entrée

17
3.3 Désinfection du système d'alimentation en eau de votre domicile
La marche à suivre décrite ci-dessous est recommandée dans le cas de l'installation d'un VPS1140-1 non alimenté en eau par une municipalité.
Pour les VPS1140-1 installés dans un édifice alimenté en eau par le réseau municipal, la désinfection du système est à la discrétion de
l'utilisateur.
Avant de démarrer le VPS1140-1, il est préférable de stériliser le système d'alimentation en eau de votre foyer qui relie votre VPS1140-1 à vos
robinets et à vos autres sorties d'eau pour détruire toute source de contamination résiduelle. Vous pouvez également avoir recours à ce traitement
lorsque de l'eau non traitée s'est introduite dans votre système d'approvisionnement (p.ex. suite à une dérivation involontaire, à des ajouts ou
des réparations de plomberie, etc.). Vous pourriez également désinfecter le système d'alimentation de votre habitation saisonnière au début de
chaque saison d'utilisation.
Les agents blanchissants domestiques inodores (solution de 5 % d'hypochlorite de sodium) sont des désinfectants efficaces lorsqu'ils sont utilisés
à raison de 1 litre (0,3 gallon) d'agent blanchissant par 1 000 litres (2,64 gallons) de volume de la tuyauterie dans la maison. Ceci comprend le
volume d'eau que contiennent l'ensemble des conduits, le réservoir à eau chaude, etc. situés «en aval» des boîtiers de filtres. Cette formule crée
une concentration de 50 mg/L ou 50 ppm, ce qui est suffisant pour la désinfection.
Pour désinfecter votre système d'alimentation en eau, veuillez suivre les étapes ci-dessous (assurez-vous que votre système de
traitement d'eau par UV reste en marche pendant l'opération) :
1. Apprenez à reconnaître les différents robinets d'arrêt de votre système d'alimentation en eau. Vous devez savoir quelles combinaisons
de robinets vous permettent d'isoler le VPS1140-1.
2. Fermez la conduite principale d'alimentation en eau et videz le réservoir à eau chaude ainsi que tout autre réservoir de stockage situé
en aval des boîtiers de filtres.
3. Fermez les robinets qui isolent la cartouche du filtre à sédiment et du filtre au charbon et pour les retirer de leurs boîtiers. Retirez les
boîtiers de filtres en utilisant la clé fournie avec votre système. Versez une ou deux tasses d'agent de blanchiment domestique dans
le boîtier vide du filtre à sédiment et rattachez le boîtier au couvercle du filtre. Le filtre à sédiment et le filtre au charbon ne doivent pas
être dans l'appareil durant la chloration.
4. Réinstallez les boîtiers de filtres (toujours sans les filtres). Assurez-vous que les boîtiers s'appuient correctement sur les têtes de filtres.
Rouvrez les conduites d'eau et assurez-vous qu'il n'y a pas de fuite.
5. Allez au robinet le plus éloigné dans la maison et laissez couler l'eau froide jusqu'à ce que vous remarquiez une odeur d'agent de
blanchiment. Répétez le processus avec tous les robinets de la maison, y compris la machine à laver, les pommes de douche et les
toilettes.
Attention à la procédure ci-dessus (étapes 1 à 5) : l’ajout de chlore (eau de Javel) dans un réservoir d’eau chaude qui a été alimenté dans le
passé avec de l’eau brute non traitée avec des taux élevés de contaminants (fer, manganèse, sulfate d’hydrogène, organismes, etc.) entrainera
une oxydation de ces contaminants et pourra nécessiter un rinçage répété du réservoir d’eau chaude. Cette éventualité doit être adressée
indépendamment en suivant la procédure de démarrage.
6. Laissez agir la solution dans les conduits pendant 30 minutes.
7. Retirez les boîtiers de filtres à l'aide de la clé fournie avec le système. Replacez le filtre à sédiment et le filtre au charbon dans leurs
boîtiers respectifs et rattachez-les au système. Assurez-vous que les boîtiers s'appuient correctement sur les têtes de filtres.
8. Ouvrez lentement la conduite principale d'approvisionnement en eau et vérifiez si le système présente des fuites.
Attention : Vous devez absolument vous assurer que votre système d'alimentation en eau ne contient plus de chlore avant de l'utiliser à nouveau.
FAITES PREUVE D'UNE EXTRÊME PRUDENCE, car la quantité de chlore que vous avez versée dans l'appareil était 25 à 50 fois plus élevée que
celle que contient l'eau traitée par les municipalités (ceci était nécessaire pour désinfecter les tuyaux d'alimentation de votre domicile). Il est
essentiel de suivre les consignes de rinçage pour tous les robinets de la maison avant de les réutiliser.

18
4. Consignes d'utilisation
4.1 Démarrage initial
Le système VPS1140-1 a été conçu pour être raccordé à la conduite d'eau froide seulement.
REMARQUE : Le système UV devrait fonctionner en permanence pour protéger votre système d'alimentation en eau en tout temps. Lorsque le
système fonctionne normalement, le témoin à DEL de mise en marche vert est allumé. Lorsque l'eau ne circule pas dans l'appareil, l'eau qui
se trouve dans la chambre de réaction vitapur® sera réchauffée par la lampe UV. Ouvrez le robinet d'eau froide et laissez couler l'eau pendant
environ 30 secondes pour enlever toute l'eau réchauffée.
La présence de petites bulles d'air dans votre système d'alimentation en eau donne parfois à l'eau une apparence laiteuse, mais ces bulles n'ont
aucun effet sur la qualité ou le goût de l'eau. Au cours des premiers jours ou des premières semaines qui suivent l'installation d'un VPS1140-1,
l'eau filtrée peut sembler trouble, car l'air contenu dans les filtres et dans le reste du système se libère dans l'eau. Plus vous utiliserez l'appareil,
plus vite votre eau redeviendra limpide.
Les étapes de mise en marche suivantes doivent toujours être respectées, tant à la première utilisation de votre système VPS1140-1
que lorsque vous le remettez en service après une certaine période :
1. Fermez la vanne principale d’alimentation en eau.
2. Montez le système UV avec support au mur. Veuillez noter qu’à cause du poids du support UV, il est essentiel que l’unité soit montée
directement dans un mur en béton (vis et joints non fournis) ou dans les colombages (vis et joints fournis). Ne montez pas l’unité
directement sur une cloison sèche.
3. Branchez les prises d’entrée et de sortie d’eau. Pour faciliter l’installation et les rechanges, il est recommandé d’utiliser des coupleurs
sur le conduit d’entrée et de sortie.
4. Les filtres sont emballés; retirez cet emballage autour des filtres. Montez le(s) filtre(s) et le(s) boîtier(s) sur le système UV avec support.
5. Aplombez les branchements d’entrée et de sortie d’eau. Pour faciliter l’installation et les rechanges, il est recommandé d’utiliser des
coupleurs sur le conduit d’entrée et de sortie.
6. Vérifiez que tous les raccordements de plomberie sont sécurisés. Ouvrez partiellement la vanne principale pendant que vous évacuez
l’air du système en ouvrant le robinet en aval.
7. Branchez le système de désinfection Vitapur UV et vérifiez que la lampe UV est allumée : lueur violette visible à travers le VuCap®.
8. Si aucune fuite n’est visible à faible débit, ouvrez la vanne d’alimentation principale à fond. Vérifiez s’il y a des fuites.
9. Pour la désinfection au chlore du réseau d’eau domestique, suivez les instructions à la section 3.3.
10. Ouvrez le robinet en aval et faites couler l’eau dans le système pendant 15 minutes avant usage.
11. Votre système UV avec support est prêt à l’usage.
4.2 Technicien d'entretien agréé
Les instructions suivantes vous sont fournies pour vous aider à effectuer l'entretien général du système, à remplacer la lampe UV ou le manchon
de quartz et à nettoyer le manchon de quartz. Toutes les autres réparations doivent être effectuées par un technicien d'entretien agréé. Pour
obtenir une liste des techniciens d'entretien agréés, veuillez visiter notre site Web au www.ghpgroupinc.com ou téléphoner à notre centre de
service à la clientèle au 1 866-253-0447.
5. Service et entretien
Votre distributeur d'eau VPS1140-1 fait appel à un procédé de traitement incluant la filtration et un système optique qui traite l'eau à l'aide d'une
lumière ultraviolet. Les filtres à eau, le tube de quartz tube et la lampe à rayons UVA doivent être remplacés régulièrement pour que le VPS1140-1
offre un rendement maximal.
La lampe à rayons UVA a une durée de vie approximative de 9000 heures (un an). Les lampes UV et les manchons de quartz de rechange UV
sont disponibles chez un détaillant autorisé et à GHP Group inc. N'utilisez que les lampes et les manchons vitapur® afin d'assurer le rendement
maximal du système. Le numéro de modèle de la lampe et du manchon de quartz de rechange est # VUVL-8
Votre système vitapur® de désinfection par UV est doté d'un témoin de défaillance visible et audible. En cas de défaillance de la lampe UV, le DEL
lumineux clignotera et le ballast électronique de l'appareil émettra un long signal sonore. Veuillez prendre note que si cela se produit et que votre

19
source d'eau n'est pas celle de la municipalité, vous devriez cesser immédiatement d'utiliser l'eau si vous avez besoin d'eau potable jusqu'à ce
que la lampe ait été remplacée et que le processus de désinfection des canalisations de distribution soit terminé.
5.1 Installation et remplacement de la lampe
AVERTISSEMENT : La lampe peut chauffer après une utilisation prolongée et risque de vous brûler si vous y touchez. Laissez-la refroidir pendant
au moins 5 minutes avant de l'enlever.
Ne faites pas fonctionner la lampe UV à l'extérieur du réacteur. Elle émet une lumière ultraviolette qui peut causer des dommages permanents à
la peau et aux yeux. Ne regardez jamais la lampe lorsqu'elle est allumée.
Ne manipulez la lampe UV que par les extrémités. Ne touchez pas l'ampoule de la lampe avec vos doigts. Si la surface de la lampe est sale,
utilisez un linge propre non pelucheux et un nettoyant pour verre pour enlever la saleté.
Instructions de remplacement et d'installation de la lampe à rayons UVA (UV)
1. Fermez l'alimentation en eau aux deux extrémités du système.
2. Débranchez l'appareil.
3. Laissez la lampe refroidir pendant au moins 5 minutes.
4. Retirez le connecteur à l'extrémité de la lampe UV.
5. Retirez la lampe UV du manchon de quartz en la dévissant doucement. Assurez-vous de ne tenir la lampe que par les pointes en
céramique.
6. Insérez la nouvelle lampe UV dans le manchon de quartz et fixez-y le connecteur.
7. Ouvrez lentement l'alimentation en eau et vérifier l'étanchéité du système.
8. Branchez l’unité et assurez-vous que la lampe UV fonctionne. Une lueur violette devrait se voir à travers le VuCap®.
5.2 Nettoyage du manchon de quartz
Les dépôts minéraux et l'accumulation de sédiments sur le manchon de quartz diminuent le rendement du système, car ils augmentent la
quantité de lumière UV transmise par le manchon dans la colonne d'eau.
L'entretien et le remplacement adéquats du filtre à sédiments et de la cartouche de charbon fournis avec le système VPS1140-1 permettent de
réduire l'accumulation de minéraux et de sédiments sur le manchon de quartz.
Pour nettoyer le manchon de quartz, il suffit d'utiliser un produit antitartre commercial non abrasif à l'aide d'un linge non pelucheux. Il est
préférable de nettoyer le manchon de quartz régulièrement afin d'en assurer le rendement maximal. Le nombre de nettoyage requis dépend de la
qualité de l'eau du réseau local.
Il ne doit rester aucune trace de solution de nettoyage sur le manchon avant qu'il ne soit réinstallé dans le système. Prenez soin d'empêcher que
tout liquide nettoyant n'entre en contact avec la surface intérieure du manchon de quartz.
Instructions pour enlever et réinstaller le manchon de quartz :
1. Fermez l’alimentation en eau à la vanne d’entrée.
2. Débranchez l’unité.
3. Videz l’eau de la chambre UV en acier inoxydable.
4. Donnez 5 minutes à la lampe pour refroidir.
5. Tournez le VuCap® dans le sens opposé des aiguilles d’une montre pour pouvoir retirer la lampe UV.
6. Retirez le raccordement au bout de la lampe UV.
7. Retirez la lampe UV de la douille en quartz. Assurez-vous de tenir la lampe UV par les bouts en céramique.
8. Retirez l’écrou de maintien de la douille en quartz et le joint torique de la douille en quartz.
9. Retirez la douille en quartz et lavez comme indiqué ci-dessus. Essuyez une dernière fois à l’alcool isopropylique pour éliminer
les résidus de produit nettoyant.
10. Insérez la douille en quartz dans la chambre UV.
11. Placez le joint torique dans la douille en quartz, puis serrez fortement l’écrou de maintien pour assurer l’étanchéité du joint.
12. Insérez une nouvelle ou ancienne lampe UV dans la douille en quartz et branchez le raccord du ballast à la lampe UV.
Ensuite attachez la tête du VuCap® à la base du VuCap® en tournant à un quart dans le sens des aiguilles d’une montre.
13. Remplissez la chambre UV lentement en ouvrant juste assez pour remplir la chambre d’eau.
14. Vérifiez s’il y a des fuites. S’il n’y en a pas, ouvrez la vanne d’entrée d’eau à fond.
15. Branchez le secteur au ballast.
16. Vérifiez que la lampe UV fonctionne bien. Une lueur violette devrait se voir à travers le VuCap®.
Table of contents
Languages:
Other vitapur Water System manuals
Popular Water System manuals by other brands

ECOScience
ECOScience 6300wt Installation and user manual

HydraMaster
HydraMaster Diamond Products GTXR+ Owner's Guide and Maintenance Logs

Weishaupt
Weishaupt WHI freshaqua 44 manual

Field Controls
Field Controls CLEARWAVE CW-125 Installation and maintenance manual

Tecnogas
Tecnogas ProCLEAN STORMY Operation manual

Orbinox
Orbinox RB manual

ELKHART BRASS
ELKHART BRASS HydroBlast 7100MG EXM2 Installation, operating, & maintenance instructions

Zip
Zip HydroTap G4 Installation and operating instructions

Watts
Watts Series N36-M1 installation instructions

Jmey
Jmey JM-F001 user manual

Sears
Sears CRAFTSMAN 390.252157 owner's manual

Julabo
Julabo Corio C Original operating manual