Vivax HPS-42HM65AERI/I1T19H3s User manual

&/
8VHUPDQXDO
HPS-84HM100AERI/IT241H3s
HPS-120HM155AERI/IT241H3s
ɂ
HPS-42HM65AERI/I1T19H3s


CONTENTS
1SAFETY PRECAUTIONS
2
ACCESSORIES
02
08
2.1
3INSTALLATION SITE
4
INSTALLATION
09
10
4.1 Dimensions of the unit
4.2 Installation requirements
10
11
4.3
4.4
Servicing space requirements
Mounting the indoor unit
11
11
5
CONNECTING THE REFRIGERANT PIPING
6
CONNECTING THE WATER PIPING
12
13
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
Connecting the space heating(cooling) water piping
Connecting the domestic water piping
Connecting the recirculation water piping
Connecting the drainage hose to the indoor unit
Connecting the solar circulation piping (if needed)
Water piping insulation
Water circuit anti-freeze protection
Filling water
13
13
14
15
15
15
15
17
GNIRIWDLEIF7 20
7.1
7.2
7.3
7.4
7.5
7.6
Precautions on electrical wiring work
Precautions on wiring of power supply
Safety device requirements
Before connecting the wiring
Connecting the main power supply
Connecting for other components
20
20
21
21
22
23
8
START-UP AND CONFIGURATION
29
8.1
8.2
8.3
8.4
Initial start-up at low outdoor ambient temperature
Pre-operation checks
Field settings
About FOR SERVICEMAN
29
29
30
31
6.9 Typical Applications 18

9
TEST RUN AND FINAL CHECKS
37
9.1 Final checks
9.2 Test run operation (manually)
37
37
10
MAINTENANCE AND SERVICE
TECHNICAL SPECIFICATIONS
37
11
38
ERROR CODE
12
44
ANNEX A
47

1 SAFETY PRECAUTIONS
DANGER
WARNING
CAUTION
NOTE
WARNING
This appliance which connect 1-phase 6KW backup heater can be connected only to a supply with system
impedance no more than 0.3079Ω. In case necessary, please consult your supply authority for system impedance
information.
WARNING
02

Special requirements for R32
WARNING
NOTE
WARNING
NOTE
charged
charged >
WARNING
03

T
#
##A
A ≥VA B
min
a
≥VAmin
≥1.8m
Use Table 2 in page5 to calculate the
total minimum floor area (A
mintotal
)
(m2)
required for the total refrigerant charge (m
c
)
Use Table 3 in page5 and dm to calculate
the minimum opening area (VA
min
,cm2)
for natural ventilation between # A room
and # B room
04

1
2
2
Table 1-Maximum refrigerant charge allowed in a room:indoor unit
Table 2-Minimum floor area:indoor unit
Table 3-Minimum venting opening area for natural ventilation:
indoor unit
NOTE
The value of " (H)" is the distance from the lowest point of the refrigerant pipe of indoor unit to the
ground
Minimum floor area(m
2
) Minimum floor area(m
2
)
mc(kg) mc(kg)
H=1230mm(100/190)
6.90
7.31
7.70
8.10
8.51
8.93
9.36
9.80
10.3
10.7
11.2
11.7
12.2
H=1500mm(100/240,160/240)
4.70
4.92
5.18
5.45
5.72
6.01
6.30
6.59
6.89
7.20
7.52
7.84
8.10
1.85 1.85
1.90 1.90
1.95 1.95
2.00 2.00
2.05 2.05
2.10 2.10
2.15 2.15
2.20 2.20
2.25 2.25
2.30 2.30
2.35 2.35
2.40 2.40
2.45 2.45
mcmmax dm=mc-mmax(kg) Minimum venting opening area(cm2) Minimum venting opening area(cm2)
H=1230mm(100/190)
375
350
330
315
302
H=1500mm(100/240,160/240)
290
280
268
258
247
0.3 2.11
0.5 1.91
0.7 1.71
0.9 1.51
1.1 1.31
1.3 1.11 278 228
1.5 0.91 245 200
1.7 0.71 203 167
1.9 0.51 154 126
2.1 0.31 98 80
05

DANGER
WARNING
:
:
:
CAUTION
06

10
NOTE
CAUTION
07

abcd
1Unpacking
08
17.5mm
Installation Fittings Installation Fittings
Quantity Shape Quantity
Name Shape Name
100 190 100 240 160 240 100-190 100-240 160-240
Installation and owner’s
manual(this book)
M9 Copper Nut
1111 1 1
M16 Copper Nut 1 1 1
Operation manual 1 1 1 Y-shape filter 111
M16 Copper Nut Tamper
Cap 1 1 1 Operation manual
(Wire controller) 1 1 1
M9 Copper Nut Tamper
Cap 1 1 1 Transfer 9.52-6.35 1 1 1
M6 Copper Nut Tamper
Cap 1 1 1
Belt L200 2 2 2
Throat bander 1
11
17.5mm

Fig. -
WARNING
Do not install the IDU near a bedroom;
Suggest install it in a garage, utility room, corridor, basement, or laundry room;
Be sure to adopt adequate measures to prevent the unit from being used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunction, smoke or fire. Please instruct the customer
to keep the area around the unit clean.
The equipment is not intended for use in a potentially explosive atmosphere.
Please connect the top pipe or fill the water tank immediately after removing the wooden frame, so as not to cause
the machine to tip over.
Remove the wooden base
5
Fig. -5
09
17.5mm
17.5mm
Four
Four one of them
Fig. -4
17.5mm

The indoor unit is to be floor mounted in an indoor location that meets the following requirements:
The installation location is frost-free.
The space around the unit is adequate for serving(Refer to Fig.4-2).
There is a provision for condensate drain and pressure relief valve blow-off.
CAUTION
When the unit is running in the cooling mode, condensate may drop from the water inlet and water outlet pipes. Please
make sure the dropping condensate will not result in damage of your furniture and other devices.
4 INSTALLATION
4.1Dimensions of the unit:
Select an installation site where the following conditions are satisfied and one that meets with your customer's approval.
- Safe places which can bear the unit's weight and where the unit can be installed at an even level.
- Places where there is no possibility of flammable gas or product leak.
- The equipment is not intended for use in a potentially explosive atmosphere.
- Places where servicing space can be well ensured.
- Places where the units' piping and wiring lengths come within the allowable ranges.
- Places where water leaking from the unit cannot cause damage to the location (e.g. in case of a blocked drain pipe).
- Do not install the unit in place s often used as a work space. Incase of construction work (e.g. grinding etc.) where a lot of
dust is created, the unit must be covered.
- Do not place any object or equipment on top of the unit (top plate)
-Do not climb, sit or stand on top of the unit.
- Be sure that sufficient precautions are taken in case of refrig erant leakage according to relevant local laws and regulations.
- Don’t install the unit near the sea or where there is corrosion gas.
When installing the unit in a place exposed to strong wind, pay special attention to the following.
In normal condition,refer to the figures below for installation of the unit:
CAUTION
The indoor unit should be installed in an indoor water proofplace.
2
1
2
1
17.5mm
17.5mm
10
Fig.4-1

unit:mm
NO. NAME NO. NAME
1Refrigerant gas connection 5/8"-14UNF 6Space heating (cooling) water inlet .R1"
2Refrigerant liquid connection 3/8" -14 UNF 7Space heating (cooling) water outlet .R1"
3Domestic hot water outlet R3/4‘’ 8Drainage 25
4Domestic hot water water
inlet (Plugged by the nut). 9Solar circulation outlet ( )
5Domestic cold water inlet 10 Solar circulation inlet ( )
The content in the dotted
The indoor unit is packed by the carton cap and corner.
At delivery, the unit must be checked and any damage must be reported immediately to the carrier claims agent.
Check if all indoor unit accessories are enclosed.
Bring the unit as close as possible to the final installation position in its original package in order to prevent damage during transport.
When the water tank is free of water, the maximum net weight of indoor unit with water tank shall reach about 158Kg,which needs
to be lifted by special equipment.
Unit:mm
Lift the indoor unit from the pallet and place it on the floor.
Slide the indoor unit into position.
Adjust the height of the leveling feet(Refer to Fig.4-3)to compensate for floor irregularities. The maximum allowed deviation is 1°
(Refer to Fig. 4-4)
≥100 ≥100
≥800
11
≥
600
300
4.2 Installation requirements
4.3 Servicing space requirements
4.4 Mounting the indoor unit

Fig. -3
Fig. -4
5CONNECTING THE REFRIGERANT PIPING
,tinuroodtuodnatinuroodniehtneewtebepip. tnaregirfergnidragersnoitacificepsdnasnoitcurtsni,senilediugllaroF
please refer to "Installation and ower's manual (M-thermal split outdoor unit)
Connecting the 16mm refrigerant pipe to the refrigerant gas connection.
Sufficiently tighten the flare nut
(Refer to Fig.5-3)
Check the tightening torque(Refer to the right table).
ighten it with a spanner and torque wrench (Refer to Fig.5-4)
The protective nut is a one-time part, it can not be reused. In
case it is removed,it should be replaced with a new one.(Refer to
Fig. - )
Outer
Tightening
Additional tightening
torque(N.cm)
diam.
torque(N.cm)
6.35 1500
1600
(153kgf.cm)
(163kgf.cm)
9.52
2500 2600
(255kgf.cm) (265kgf.cm)
16
4500 4700
(459kgf.cm) (479kgf.cm)
Indoor unit tubing Flare nut Pipings
a Refrigerant liquid connection
b Refrigerant gas connection
Protective nut
Fig. - Fig. -
b
a
17.5mm
b
a
17.5mm
Fig. - Fig. -
CAUTION
;.
Fig. -
12
﹤
17.5mm
!(Refer to Fig.5-4)
Refer to

CAUTION
When flared joints are reused ,the flare part should be re-fabricated.
6 CONNECTING THE WATER PIPING
6.1 Connecting the space heating(cooling) water piping
To facilitate service and maintenance, two shut-off valves(field supply) and one overpressure bypass valve should be
installed. The two shut-off valves should be mounted on the space heating(cooling)water inlet and outlet .
Fig. -1
The shut-off valve should be mounted on the domestic cold water inlet.
1.Connect the shut-off valve to the cold water inlet .
2 Connect the cold water pipe to the shut-off valve.
3 Connect the domestic hot water pipe to the hot water outlet
1.Connecting the shut-off valves to the indoor units.
2.Connecting the shut-off valves to the space heating(cooling) water pipes.
Fig. -2
17.5mm
17.5mm
13

6.3 Connecting the recirculation water piping
If domestic hot water recirculation function is requested,the recirculation pipe should be connected.
Fig.6-3
Fig.6-4
1.Removing the nut of the recirculation on the indoor unit.
2.Connecting the recirculation water pipe to the indoor unit.
17.5mm
17.5mm
14

The water coming from the pressure relief valve and the condensate water is collected in the drain pan.
The drain .
Fig. -5
Fig. -6
When the unit is not running for a long time,make sure the unit is powered on all the time
The power of the unit also needs to be cut off after water in the system is drained.
The insulation material should at
least of B1 fire resistance rating and complies with all applicable legislation. The thickness of the sealing materials must be at least
13 mm with thermal conductivity 0.039 W/mK in order to prevent freezing on the outside water piping.
If the temperature is higher than 30°C and the humidity is higher than RH 80%, then the thickness of the insulation
materials should be at least 20 mm in order to avoid condensation on the surface of the insulation piping.
which use the heat pump and backup heater (if aviliable) to protect the entire system from
freezing. When the temperature of the water flow in the system drops to a certain value, the unit will heat the water by using the heat
pump or the electric heating tap or the backup heater. The anti-freeze protection function will turn off only when the temperature
increases to a certain value.
needed
If the solar kit is designed in the system. The solar circulation water pipe should be connected to the inlet and outlet connector of
indoor unit.
6.4 Connecting the drainage hose to the indoor unit
17.5mm
Floor drain
15
Throat bander
Connect the drainage pipe with a throat bander and insert the drainage pipe into the floor drain.

The
flow switch should be removed and dried, then can be reinstalled in the unit.
NOTE
CAUTION
Be careful not to deform the unit’s piping by using excessive force when connecting the piping. Deforming the piping may
lead to malfunction of heat pump.
If air, moisture or dust gets in the water circuit, problems may occur. Therefore, always take into account the following when connecting
the water circuit:
Use clean pipes only.
Hold the pipe end downwards when removing burrs.
Cover the pipe end when inserting it through a wall to prevent dust and dirt entering.
Use a good thread sealant for sealing the connections. The sealing must be able to withstand the pressures and temperatures
of the system.
When using non-copper metallic piping, be sure to insulate two kind of materials from each other to prevent galvanic corrosion.
As copper is a soft material, use appropriate tools for connecting the water circuit. Inappropriate tools will cause damage to the pipes.
NOTE
The unit is only to be used in a closed water system. Application in an open water circuit can lead to excessive corrosion of the
water piping:
Never use Zn-coated parts in the water circuit. Excessive corrosion of these parts may occur as copper piping is used in the
unit's internal water circuit.
When using a 3-way valve in the water circuit. Preferably choose a ball type 3-way valve to guarantee full separation between
the domestic hot water and floor heating water circuit.
When using a 3-way valve or a 2-way valve in the water circuit. The recommended maximum changeover time of the valve
should be less than 60 seconds.
1.Counterclockwise rotation, remove the flow switch.
2.Dry the flow switch completely.
1
2
There need drying
Fig. -7
16

During filling, it might not be possible to remove all air in the system. be removed through the automatic air
purge valve during the first operating hours of the system. Topping up the water afterwards might be required.
The water pressure indicated on the manometer will vary depending on the water at higher
bar to avoid air entering the circuit. The
Directives.
Connect the water supply to the filling valve and open the valve.
with water until the indicates a pressure of approximately 2.0 bar. air in the circuit as
much as possible using the automatic air purge valves.
least 2 full turns to release air
from the system.
3 Close all water taps after all air is purged.
low through the discharge pipe.
When circulation in each space heating loop is controlled by remotely controlled valves, it is important that this minimum
17
●
Cold water inlet pressure should be less than 1.0MPa. Expansion vessel and safety valve(field supply,protection pressure
is 1.0MPa)must be installed.
●
Warning and Water Quality Directive and Groundwater:This product is designed to comply with the European Water Quality
Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case of the use of
groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in
areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
CAUTION
This manual suits for next models
2
Table of contents
Popular Heat Pump manuals by other brands

Carrier
Carrier 50MQ Installation, Start-Up and Service Instructions

GE
GE Zoneline AZ91H18E E Series owner's manual

Viessmann
Viessmann VITOCAL 300-A operating instructions

Panasonic
Panasonic Aquarea WH-SXC09H3E5 quick guide

Carrier
Carrier 50TJQ004-007 Installation, Start-Up and Service Instructions

DeDietrich
DeDietrich MIT-M /E Installation, user and service manual