IMPORTANT INSTRUCTIONS
SPECIFICATIONS
Read all instructions before installing or using this heater.
This heater is hot when in use. To avoid burns keep bare skin away from hot surfaces.
Keep combustible materials, such as electrical cords, furniture, pillows, bedding, papers,
clothing, and curtains at least 3 feet (0.9 m) from the front of the heater and keep them
away from the sides and rear.
Extreme caution is necessary when any heater is used by or near children or invalids and
whenever the heater is left operating and unattended.
Always switch off the power to the heater when not in use.
Do not operate any heater if it is faulty, has been dropped or damaged in any manner.
Disconnect the power supply at the service panel and have the heater inspected by a
reputable electrician before reusing.
Do not use outdoors.
This heater is not intended for use in bathrooms, laundry areas or similar indoor locations.
Never locate the heater where it may fall into a bathtub or other water container.
Do not push objects of any kind into the ventilation or exhaust openings as this may result
in electric shock, fire or damage to the heater.
To prevent the risk of fire, do not block the air intake or exhaust openings in any way. Do
not use on soft surfaces, like a bed, where openings may become blocked.
A heater has hot parts inside that may arc or spark. Do not use it in areas where gaso-
line, paint, or flammable liquids are used or stored.
Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or personal injury.
To disconnect the heater, turn the device off, and turn off the power to the heater circuit
at the main disconnect panel.
This heater may include a visual alarm to warn that parts of the heater are getting exces-
sively hot. If the alarm illuminates, immediately turn the heater off and inspect for any
objects on or adjacent to the heater that may have blocked the airflow or otherwise
caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WHILE
THE ALARM LIGHT ILLUMINATING.
When using electrical appliances, basic precautions should always be taken to reduce the
risk of fire, electric shock, and personal injury, including the following:
WARNING TO PET OWNERS:
The health of some small pets, including birds, is extremely sensitive to the fumes produced
during the first-time use of many appliances. These fumes are not harmful to humans but we
recommend that you do not use your heater around birds and small pets during its initial use
until the manufacturing corrosion coatings have burned off.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
IMPORTANT INSTRUCTIONS
This product may expose you to chemicals including Diisononyl phthalate (DINP), which is
known to the State of California to cause cancer, and Diisodecyl phthalates (DIDP), which is
known to the State of California to cause birth defects or other reproductive harm.
Warning
Rating AMPS BTU/hour
8500W II 240-1-60 35.4 29010
5600W I 240-1-60 23.3 19112
6400W II 208-1-60 30.7 21843
4200W I 208-1-60 20.2 14334

Use only copper wires rated for at least 60°C.
The air flow from the heater must be directed parallel to or away from the adjacent wall.
Observe all wall, floor and ceiling clearance requirements.
All wiring must comply with national and local electrical codes. The heater must
be grounded as a precaution against possible electric shock.
The heater circuit must be protected with proper fuses.
The mounting structure and fixing hardware must be capable of supporting the weight of
the heater and the mounting bracket (if used).
All electrical power must be disconnected from the main service box, which must be
locked before connecting, inspecting, cleaning or servicing the heater. This is an import-
ant precaution to prevent serious electric shock.
This is heater is not suitable for use in hazardous areas containing explosive liquids or
vapors. This heater has hot, arcing or sparking pads inside. Do not use it in areas
where gasoline, paint or flammable liquids are used or stored.
This heater is not suitable for use in corrosive atmospheres such as marine greenhouses
or chemical storage areas.
This heater must be mounted at least 8 feet above the floor. For specific clearances,
please see the next page.
1.
2.
3.
4.
5.
6.
7.
8.
9.
SAFETY INFORMATION
3 4
Install the heater away from traffic areas, maintaining the clearances shown in Figure 1
(below). The air flow direction should not be restricted (e.g., by columns or machinery). The
airflow should wipe exposed walls rather than blowing directly onto them. Where more than
one heater is used in an area, the heaters should be installed so that the air discharge from
each heater supports the air flow of the others, to provide best warm air circulation as shown
in Figure 2.
LOCATING HEATER
THIS HEATER REQUIRES HARDWIRE INSTALLATION (NO PLUG). THE INSTALLATION
OF THIS PRODUCT MUST BE CARRIED OUT BY A CERTIFIED ELECTRICIAN AND IN
ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.
NOTE: COMPATIBLE WITH A 240V LINE VOLTAGE DOUBLE POLE WALL THERMO-
STAT. MUST BE INSTALLED BY A CERTIFIED ELECTRICIAN.
READ AND UNDERSTAND ALL INSTALI ATION &OPERATION INSTRUCTIONS PRIOR TO
OPERATING THIS UNIT. OBSERVE ALL SAFETY INSTRUCTIONS.
Warning
IMPROPER INSTALLATION OR FAILURE TO FOLLOW THE PROCEDURES OUTLINED
IN THIS INSTRUCTION MANUAL CAN RESULT IN SERIOUS ELECTRICAL SHOCK.
Warning
1212in.
1035in.
738in.
412in.
134in.
34in.
12in.,
412in.
14 in.
13 in.
Minimum
Distance
To Wall
Minimum
Distance
To Wall
Minimum
Distance
From
Discharge
To Any
Object
Minimum
Distance
To Floor
8ft.
Note: Min. clearance to ceiling
when not using mountng
brackets is 1 in.
MAXIMIUM MOUNTING HEIGHT FRO
Vertical air delivery unit=11 ft.
Horizontal air delivery unit=8 ft.
FRONT VIEW SIDE VIEW
24 in.
Figure 1
Figure 2

5 6
PRE-INSTALL ATION INSTALLATION
HANGING THE HEATER
Garage Heater
x1pc
Mounting Bracket
x1pc
Infrared Remote Control
x1pc
Screw
x3pcs
Washer
x6pcs
INSTALLATION
MOUNTING THE BRACKET
Locate a wooden stud in the wood ceiling joist. If you cannot locate a wooden stud, you
must install a piece of wood on the ceiling as this heater must be securely fastened.
Remove the mounting bracket from the heater unit by loosening the bracket screws with a
wrench and sliding the handle off over the screw heads.
Place a washer on the screws before inserting them through the holes in the mounting
bracket and screw them securely into a ceiling joist.
1.
2.
3.
Attach the heater unit to the mounting bracket.
Lift the heater up and into the mounting bracket.
Align the bracket screws with the keyhole slots in the mounting bracket.
If the heater is to be tilted it must be positioned in the keyhole slots - see Figure 4.
Tighten the bracket screws with a wrench the unit is securely suspended horizontally or
vertically.
1.
2.
3.
4.
5.
(Refer to Figures 3a and 3b.)
NOTE: If the heater is to be swivelled either to the right or left, it is recommended that a
washer is added to both sides of the bracket. A longer lag bolt may be required to secure the
unit properly. See Figure 3a.
Figure 3a. Single-Screw Mounting Figure 3b. Double-Screw Mounting
Washer
Bracket
Wood Ceiling
Diagonal Lag Bolt
38in.
Washer
Bracket
Wood Ceiling
Diagonal Lag Bolt
38in.
Use top keyhole
slots if heater is
to be tilted down
1. remove screw to
open door
2
Figure 4

To rotate the unit if it has been installed with a single lag bolt (as shown in Figure
4a), simply turn the entire heater as needed. The unit cannot be rotated horizontally if it
has been installed with 2 lag bolts.
To tilt the unit vertically, loosen the bracket screws (see Figure 4).
7 8
INSTALLATION
ADJUSTING THE AIRFLOW DIRECTION
INSTALLATION
CONNECTING THE POWER
If you are using an external temperature controller (external thermostat) to control whether
or not the heater is on, please note the following points:
Make sure that the heater's temperature control knob (thermostat knob) is turned fully
clockwise.
Connect the wire according to the below wiring diagram.
1.
2.
1.
2.
Adjust the louvers to the desired position (see Figure 5).3.
MULTIPLE VERTICAL ANGLES
Ceiling 90°
90°
45°
45°30°
BG G
GND
A
ACL2
ACL1
PCB
Selected Switch
Selected Switch
(Heater's thermost at,
External thermost at)
2500W
2500W2500W
Temperature
Regulator
240AC or 208AC
60HZ
External
Thermostat
External
thermostat
Heater's
thermostat
L1
1
2
E
L2
TO PREVENT POSSIBLE ELECTRIC SHOCK, DISCONNECT POWER TO THE HEATER AT
THE MAIN SERVICE BOX BEFORE ATTEMPTING TO ADJUST THE HEAT OUTPUT OF
THIS UNIT.
Warning
Warning: disconnect power
before servicing.
NOTE: If the heater is to be tilted vertically, it must be mounted in bottom keyhole slots of
the mounting brackets to maintain adequate clearance and prevent possible overheating.
NOTE: The louvers are designed not to
close completely. Do not attempt to bypass this
feature as this may result in damage to the unit.
Figure 5
BG G
GND
A
ACL2
ACL1
PCB
Selected Switch
2500W
2500W2500W
Temperature
Regulator
240AC or 208AC
60HZ
External
Thermostat
L1
1
2
E
L2
Terminal station
External Thermostat
Line
red
Load
Black

Conduit Conduit Connector
White Green
(or bare copper)
Black
L2
L1
Flexible Conduit ConnectorFlexible Conduit
Flexible NM Cable
1 2
3 4
Flexible NM Cable Connector
3ft
INSTALLATION
The external temperature control (external thermostat) should be in accordance with the
requirement of the UL or ETL standard.
The lead wire of the external temperature control (external thermostat) must not be less
than 22 AWG.
3.
4.
Remove the screw from the front of the unit to connect the power supply to the heater.
Attach the cable connectors to the unit (see Figure 6) and slide the 10-gauge wire
through the cable connector.
1.
2.
Connect the wire to the power block located in the base of the heater - see Figure 6.
Switch on the power to the main service.
3.
4.
9 10
INSTALLATION
When starting the heater, slowly turn the temperature control clockwise slowly to terminal,
the unit starts the fan first, then starts the heater.
When switching off the heater by turning the temperature control counterclockwise to off,
the heating element first will turn off then the fan will run a short cooling cycle and then turn
off.
TO PROTECT THE HEATER
NOTE: All wiring must be carried out by a qualified electrician and must be in accordance to
national and local electrical codes. For certain applications, conduit may be required, see
Figure 6. Check local electrical codes. If you are running the wiring in conduit and wish to be
able to turn the heater, be sure to purchase enough flexible conduit to allow the heater to be
rotated.
CONNECTING THE POWER
THIS APPLIANCE MUST BE GROUNDED!
THE APPLIANCE MUST BE CONNECTED TO A CURRENT PROTECTION CIRCUIT OR
DEVICE AT 50AMP OR LESS BEFORE BEING CONNECTED TO POWER SUPPLY!
Warning
TO REDUCE THE RISK OF FIRE, DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS NEAR THE HEATER.
Warning
HIGH TEMPERATURES - RISK OF FIRE. KEEP FLAMMABLE MATERIALS, SUCH AS
FURNITURE, PILLOWS, BEDDING, PAPERS, CLOTHING, ELECTRICAL CORDS AND
CURTAINS AT LEAST 3 FT. (0.9 M) FROM THE FRONT AND TOP OF THE HEATER AND
KEEP THEM AWAY FROM THE SIDES AND REAR. TO REDUCE THE RISK OF FIRE, DO
NOT USE IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE USED
OR STORED.
Warning
Conduit Conduit Connector
White Green
(or bare copper)
Black
L2
L1
Flexible Conduit ConnectorFlexible Conduit
Flexible NM Cable
1 2
3 4
Flexible NM Cable Connector
3ft
Connectors, cable, and hardware used to wire the heater Figure 6

Using the touchpad control panel located on the front of the garage heater below the air
guide plates.
Using the multi-function remote control unit.
-
-
Check that the garage heater outlet grill is not covered or obstructed in anyway, and make
sure the power to the unit is switched on.
The garage heater control functions can be accessed in two (2) ways:
This button supplies power to all functions of the garage heater. It must be switched on for
the garage heater to operate.
OPERATING INSTRUCTIONS
11 12
OPERATING INSTRUCTIONS
1
12453
Control Panel
2
4
5
6
THE HEATER MUST BE PROPERLY INSTALLED BEFORE IT IS USED.
Warning
1. Main Power Button:
This button adjusts the 3 heating levels: OFF, FA (Fan Only), AU: LOW (6400W displays "L")
or High (8500W displays "H").
2. Heater Control Button:
This LED display shows the set point for the temperature and timer functions. When either of
these functions is activated, the display will show the set point for about 10 seconds and
then fade to black. Any change to the set point of the temperature or timer set point reacti-
vates the display, which then disappears after approximately 10 seconds.
3. Temperature/Timer Display:
This button controls the Timer OFF (no display) and 8 settings from 1 to 8 hours. When the
Timer is turned on, it will come on at the shortest time setting (1hour). Each time the Timer
button is pressed, the time increases by 1 hour, up to the longest setting (8 hours). Once the
set time expires, all garage heaters functions will be automatically turned off.
5. Timer Button:
REMOTE:
▼ DOWN Control Button: Only in "AU" mode, this button is used to decrease temperature.
▲UP Control Button: Only in "AU", this button is used to increase temperature.
GARAGE HEATER :
Only in "AU", this button is used to increase the temperature setting. To switch from Fahren-
heit to Celsius, or vice versa, hold this button for 3 seconds.
The temperature range is between 10°C - 35°C (50°F - 95°F) in 1-2°F (1°C) increments. In the
AU (H/L) gear, when the set temperature more than or equal to ambient temperature 0
degrees but less than or equal to 5 degrees, the heater will be switched to low power to save
energy. The heater is firing high power only when the set temperature is out of 5 degrees
range. Until the ambient temperature is more than the set temperature, the heater will stop
heating, but the fan will stop working after 60 seconds.
4.Temperature Control Button

1
6 7
8 9 10 11 12 13 14
15
16
23
45
Before cleaning, make sure that the power is switched off at the circuit breaker panel and
that the heating element of the heater is cool.
To maintain the external appearance of the heater it is necessary to occasionally wipe the
unit with a dry cloth. During the summer months, or at other times when the appliance is
not in use and is completely cold, it should be wiped over with a damp cloth.
Do not use abrasive clearing powders or furniture polish. Do not use chemical or abrasive
products, metal scourers, etc., to clean the unit as they may damage the surface.
Disconnect the power supply during the summer months or when not in use. Store the
unit in a dry and cool place.
All other services should be carried out by qualified service personnel. Do not try to repair
the heater yourself.
1.
2.
3.
4.
5.
OPERATING INSTRUCTIONS
MAINTENANCE
13 14
1
2
Part Descriptiom Part#
Back mesh HS1250-06001
Hanging plate HS1250-06002
3
4
Fan blade HS1250-06003
Air guide plate HS1250-06004
5
6
Large handle seat HS1250-06005
Small handle seat HS1250-06006
7
8
Spring HS1250-06007
Motor HS1250-06008
9
10
Part Descriptiom Part#
Heater HS1285-06001
Selection switch HS1250-06011
11
12
Main board HS1275-08001
Terminal block HS1250-06014
13
14
Temperature
CUT-OFF HS1250-06017
Control panel
circuit board HS1275-08002
15
16
Button surface sticker HS1275-08003
Infrared remote
control HS1275-08004
REPLACEMENT PARTS
REMOTE:
This button displays F (Fahrenheit) or C (Celsius) depending on how the temperature mode
is set. When the garage heater is turned on, the temperature is displayed in Fahrenheit (F).
GARAGE HEATER :
To switch from Fahrenheit to Celsius or vice versa, when the garage heater is ON, hold
HEATER CONTROL button for 3 seconds. Unless power to the unit has been interrupted,
the garage heater will remember the last temperature mode setting and will start at that
setting.
6. Fahrenheit/Celsius Button:
NOTE: The motor is permanently lubricated, and no further lubrication is needed.

TROUBLESHOOTING
15 16
Unit is not
heating
Problem Root Cause Corrective Action
Garage
heater
emits a
burning
smell
The thermostat sensor is
broken or disconnected. Please call customer service.
Display
shows "EE"
Display Code
The breaker has tripped Rest the breaker at the fuse panel
and restart the heater
The heater
will not start
The overheat protection has
activated.
Inspect the garage heater and check
that the air inlets and outlets are not
blocked as this may cause overheat-
ing. Switch off the circuit breaker to
the garage heater for 30 minutes and
allow it to cool down. Turn the power
back on and operate.
The product
does not
have
electricity
entering
Heater is in Lock Mode Hold the POWER button for 10
seconds to unlock the heating
function.
The heater
button is
invalid
The heater is set to FAN
ONLY mode
Change the setting and switch to
"AUT" heating mode
Display
shows "FA"
and blows
cold air
The room temperature has
already reached the set
thermostat temperature
Adjust the temperature setting to
make sure the thermostat setting
temperature is higher than current
room temperature.
The heater
will not start
During production dust
and/or oil debris gathered
on heating coils.
Make sure the room is well
ventilated. Allow the garage
heater to run until the smell is
dissipated.
Check and make sure there
is no combustible material
within 0.9 meters (3 feet) of
the garage heater.
Remove the combustible material
around the garage heater.
This heater must be
mounted at least 8 feet off
the floor, for specific
clearances, please check
the "LOCATING HEATER"
section in the instruction
manual
Relocate the garage heater so there
is enough space between the heater
and the adjacent wall and floor.
WARRANTY
We offer a 3-year warranty against manufacturing defects for all of our products from the
date of purchase. If you need warranty assistance, please contact us as soon as possible.
The warranty does not cover damage due to high moisture levels, water damage, power
surges, improper hanging/mounting, improper use, dust build-up, or users' unauthorized
modifications.
In the USA, if any product ceases working within 30 days of use, you can choose:
Exchange: We will email you a pre-paid return label. Please ship the product back to
our USA warranty center and a replacement will be sent to you free of charge as soon
as we receive the defective product.
Refund: We will email you a pre-paid return label. Please ship the product to our USA
warranty center and we will issue a refund as soon as the product has been received.
Refund periods may depend on the processing time of your bank or institution—usual-
ly, a refund takes about 5 business days to be processed.
1.
2.
3.
Our company reserves all rights to the final explanation of this warranty structure. If you
have any questions about our warranty policy, please contact us.
4.
(A)
(B)
Table of contents
Popular Heater manuals by other brands

RADSON
RADSON FLORES C CH E - MOUNTING Instruction

LUCHT LHZ
LUCHT LHZ VPN Series Installation and operating instructions

Mestek
Mestek TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT... Installation instructions and parts identification

RAMTONS
RAMTONS RM/475 owner's manual

Dimplex
Dimplex OFC1500TLG manual

Zehnder Rittling
Zehnder Rittling ZX1 Service manual

Orbegozo
Orbegozo FH 5001 instruction manual

Viessmann
Viessmann VITOPLANAR EI2 Operating Instructions for the System User

NOBOCOOL
NOBOCOOL E2E installation instructions

VonHaus
VonHaus 2500108 instruction manual

Adler Europe
Adler Europe AD 7728 user manual

Roberts Gorden
Roberts Gorden GordonRay BH-60 Installation, operation & service manual