1
2
3
4
1 2 3 4
1234
1White Data RX
2Black Ground (-)
3 Blue Data TX
4 Red Battery 12V (+)
DBI
1Green Data RX
2Blue Data TX
3 Black Ground (-)
4 Red Battery 12V (+)
RF
1Blue Data TX
2White Data RX
3 Black Ground (-)
4 Red Battery 12V (+)
CarLink
4 Red Battery 12V (+)
3 Black Ground (-)
2Blue Data TX
1White Data RX
Weblink
4 Red Battery 12V (+)
3 Black Data TX
2 Green Warn AwayInput (-)
1 Blue Full TriggerInput (-)
Shock
1 2 3 4
PRESTIGE
FLCART Dock
Replacement Part #4120459
Replacement Part #4120460
Replacement Part #4120461
Not Included
Not Included
Not Included
Not Included
85 Red Ignition Input (+)
86 OrangeStarter Kill Input (-)
87ABlack Starter Interrupt - Key Side
30 White/Black Starter Interrupt - Motor Side
Starter Kill
86 85
87
87A
30
1 White Parking Light (30)Output
2 Black Ground Input (-)
3 White/RedParking Light (87)Input
4 YellowIgnition Input (+)
5 White/Black Siren Output (+)
6 Red Battery 12VInput (+)
6 Pin Power
P
20 BlueTrunk Shunt Input (+)
19 OrangeStarter Kill Relay/ Anti-Grind Output (-)
18 Red/Black Disarm 2 Input
17 Black/White Horn Output (-) (NOC 9)
16 Red/Yellow Disarm 1 Input
15 Dk. Blue/Black Ch. 3 Alt Output (-) (NOC 8)
14 Green/Black Arm 2 Input
13 Green/White Domelight Output (-) (NOC 7)
12 Green/Yellow Arm 1 Input
11 Lt. Blue/GreenCh. 5 AUX Output (-) (NOC 6)
10 Dk. GreenInstant TriggerInput (-)
9 Green/Lt. Blue Ch. 4 AUX Output (-) (NOC 5)
8 Lt. GreenTrunkTriggerInput (-)
7 Dk. BlueTrunkOutput (-) (NOC 4)
6 Gray/Black Hood Input (-)
5 White/BlueHeadlight Output (-) (NOC 3)
4 Purple/BrownDoorTriggerInput (- / +)
3 GreenUnlock Output (-) (NOC 2)
2Empty Empty
1 Red Lock Output (-) (NOC 1)
20 Pin Input/Output
Replacement Part #4360828
1 Black Ground (-)
2 Gray Valet Switch Input
Valet
1 Blue LED Output (-)
2 Red Battery 12V (+)
LED
Replacement Part #4120474
Replacement Part #4360833
This Harness is included with the FLCART.
For Wire Information and Diagram Please Refer to Vehicle
Specific FlashLogic Install Guide.
Visit www.FlashLogic.com for More Information.
Not Included
19
17
15
13
11
9
7
5
3
1 2
4
6
8
10
12
14
16
18
20
1
2
3
4
1 3 5
2 4 6
19
17
15
13
11
9
7
5
3
1 2
4
6
8
10
12
14
16
18
20
PROSEC
Security w/Keyless Entry
System Layout
2018 Voxx Electronics. All Rights Reserved.
Shock Sensor
Part #4700033
Compatible RF Kits
PR1BZ
PR1BZLR
PR1BTWZ
PR5BZ
PROSEC
Security w/Keyless Entry
Quick Installation Guide
For Complete Installation Guide and Technical
Support Please Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
Notications
Remote Programming
1 Chirp 2 Chirp
3 Chirp 4 Chirp 5 Chirp 6 Chirp
1Lock / Unlock Function 500ms 3.5sec
500ms L, DBL UL DBL L, 500ms UL DBL L, DBL UL 500ms L, 350ms UL
2 Ignition Lock OFF ON
3 Ignition Unlock OFF Unlock All
Unlock Driver
4 Exterior Illumination OFF With Arm
With Disarm With Arm & Disarm
5 Auto Relock OFF Auto Lock Only
Auto Lock & Arm
6 Auto Arming / Locking OFF Auto Arm Only
Auto Lock & Arm
7 Notification SoundBoth Siren
Horn
8 Horn Timing 16ms 30ms
40ms 50ms 10ms
9 Valet Override MethodValet Custom Code
Stand Alone Valet
10 Driver Priority Unlock OFF ON
11 Silent Choice OFF From Transmitter
OEM Style
12 Security ProfileAll On Doors Off
Hood/trunk Off All Off
13 Door TriggerInputNegative Positive
14 Park Light / Trunk Swap OFF ON
15 Data Port Protocol ADSDBI
16 1 or 2 Wire Disarm 2 Wire 1 Wire
17 Disarm Input
120ms Dr OR Pass
80ms Dr OR Pass 120ms, UL & Light80ms, UL & Light
18 Arm 2 InputNegative Positive
19 Disarm 2 InputPositive Negative
20 Trunk Shunt InputPositive Negative
Features
Options
Features
Negative Output Control (NOC)
1 Second Pulse
5 Second Pulse
10 Second Pulse
15 Second Pulse
20 Second Pulse
30 Second Pulse
Push & Hold
Latch ON/OFF
Horn
LED
Ch. 3 ALT Output
Ch. 4 AUX
Ch. 5 AUX
Ch. 6 AUX
Ch. 7 AUX
Lock
Unlock
Trunk
2nd Unlock
Dome Light
Head Light
AUX Output Control
2018 Voxx Electronics. All Rights Reserved.
1 Shock
2 Trunk/ Hood
3 Door
Factory Keyless Upgrade
Shock Sensor
The PROSEC can be used without transmitters as a Factory Keyless Alarm
Upgrade. Arm / Disarm 1 inputs will be connected to the Driver Door Lock Motor.
Arm / Disarm 2 inputs will be connected to the Passenger Door Lock Motor and / or
the Lock Switch. The polarity detection for Arm / Disarm 1 is preset to Positive (+).
The Arm / Disarm 2 input polarity can be set for Positive (+) or Negative (-). This is
found in Feature Bank 2, Features 17 & 18. Please refer the your vehicle specic
wiring information to determine the correct polarity.
Note: If this feature is supported by FLCART do not connect Arm / Disarm wires.
The Trunk Shunt input will be used if the vehicle is equipped with a factory power
trunk / hatch release. If equipped, connect the Trunk Shunt input to the Positive (+)
wire of the factory power trunk / hatch release motor. This will override the system’s
trunk and shock trigger inputs until the vehicle’s trunk / hatch is closed.
Negative output control allows any NOC to be programmed for any one of thirteen
(13) options. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Any AUX output can be congured using the AUX Control Menu. This feature is
only accessible via FlashLogic Weblink or Weblink Mobile.
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon
disarm, the system will beep 4x and ash the LED to indicate the Alarm Trigger
Zone.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the
Feature Bank programming.
1. Turn the ignition key ON/OFF.
2. Press and release the valet button 3x.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF.
This feature will not affect alarm trigger or programming.
User Programmable LED
System LED notications can be turned ON or OFF without entering Feature
Bank programming.
1. Turn the ignition key ON/OFF, ON/OFF.
2. Press and hold valet button for ve (5) seconds.
The LED will ash 1x for ON, 2x for OFF. This feature will not affect LED ash
during programming.
The shock sensor should be mounted to a solid surface in the center of the
vehicle. Once mounted the shock sensor will require adjustment.
To increase sensitivity: Turn adjustment dial clockwise.
To decrease sensitivity: Turn adjustment dial counter clockwise.
To test sensitivity, strike the vehicle with an open palm. Adjust the dial to provide
coverage to as much of the vehicle as possible.
Important Update:
The default data port protocol of this system is ADS. When ashing the FLCAN, or other integration module,
be sure to choose iDatalink 2-Way as the installation method.
This module will also support DBI. This will require programming Feature Bank 2, Feature 15 to DBI.
For Technical Support Visit www.voxxuniversity.com or Call 1-800-225-6074.
Feature Programming
Dome Delay Programming
The PROSEC Feature Banks can be programmed by using the valet button and
remote. To enter Feature Bank programming:
1. Turn the ignition key to ON.
2. Press and release valet button 3x. System will beep and ash lights 1x for
Feature Bank 1, Remote Programming.
3. Cycle ignition key OFF/ON. System will beep and ash lights 2x for Feature
Bank 2.
4. Press valet button to cycle features. LED will ash to display feature number.
5. Press lock button to cycle options. System will beep to indicate option number.
To exit Programming cycle ignition key OFF and wait ten (10) seconds. The System
will also automatically exit programming after sixty (60) seconds of no activity.
This system can be programmed to ignore the vehicle’s theater dimming dome light.
This feature will be used when connecting the door trigger input to the dome light
circuit for alarm trigger. Note: Vehicle windows should be open to prevent accidental
locking of keys in the vehicle.
Start with all doors closed and the vehicle dome light off.
1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2. Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns off the
system will set the delay time and add an additional two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for ve (5) seconds.
The system will beep 1x to indicate reset is complete.
The Feature Bank below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Please visit www.FlashLogic.com for more detail.
The PROSEC does not include an RF remote kit. The RF remote kit Includes two
(2) remotes, one (1) antenna, and one (1) cable. When added, remotes must be
programmed to the system. Remote Programming is located in Feature Bank 1. To
enter Remote Auto Programming:
1. Turn the ignition key to ON.
2. Press and release the valet button 3x. System will beep and ash the parking
lights 1x.
Press the lock button on each remote. The system will beep 1x to indicate the
remote has been programmed. If programming one (1) button remotes, press the
Start button. Only primary remote functions are auto programmed. This Includes
Lock, Unlock, and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels
to the remote. Please see the complete installation guide for manual remote
programming instruction.
Note: If programming 2-Way remotes, wait for the remote to beep before
programming additional remotes. This beep is conrmation that a 2-Way response
has been received from the main module.

Other Voxx Electronics Remote Starter manuals

Voxx Electronics PRESTIGE APS787Z User manual

Voxx Electronics

Voxx Electronics PRESTIGE APS787Z User manual

Voxx Electronics SRT-9000 User manual

Voxx Electronics

Voxx Electronics SRT-9000 User manual

Voxx Electronics Prestige APS997Z User manual

Voxx Electronics

Voxx Electronics Prestige APS997Z User manual

Voxx Electronics PRESTIGE APSSECRS User manual

Voxx Electronics

Voxx Electronics PRESTIGE APSSECRS User manual

Voxx Electronics Elite Series User manual

Voxx Electronics

Voxx Electronics Elite Series User manual

Voxx Electronics CA-510 User manual

Voxx Electronics

Voxx Electronics CA-510 User manual

Voxx Electronics Prestige APS997ZLR User manual

Voxx Electronics

Voxx Electronics Prestige APS997ZLR User manual

Voxx Electronics Pursuit PRO9556Z User manual

Voxx Electronics

Voxx Electronics Pursuit PRO9556Z User manual

Voxx Electronics Prestige PE1BZ User manual

Voxx Electronics

Voxx Electronics Prestige PE1BZ User manual

Voxx Electronics Prestige PE2LCD User manual

Voxx Electronics

Voxx Electronics Prestige PE2LCD User manual

Voxx Electronics Prestige PE1BTWZ User manual

Voxx Electronics

Voxx Electronics Prestige PE1BTWZ User manual

Voxx Electronics Prestige APS901TM User manual

Voxx Electronics

Voxx Electronics Prestige APS901TM User manual

Voxx Electronics Prestige APS510Z Installation and operating manual

Voxx Electronics

Voxx Electronics Prestige APS510Z Installation and operating manual

Voxx Electronics PURSUIT PR1BTWZ User manual

Voxx Electronics

Voxx Electronics PURSUIT PR1BTWZ User manual

Voxx Electronics CA-420 User manual

Voxx Electronics

Voxx Electronics CA-420 User manual

Voxx Electronics Pursuit PRO9056Z Installation and operating manual

Voxx Electronics

Voxx Electronics Pursuit PRO9056Z Installation and operating manual

Voxx Electronics Code Alarm ELITE ca1155E User manual

Voxx Electronics

Voxx Electronics Code Alarm ELITE ca1155E User manual

Voxx Electronics Prestige APSRS1Z User manual

Voxx Electronics

Voxx Electronics Prestige APSRS1Z User manual

Voxx Electronics Code Alarm Professional Series ca6155 User manual

Voxx Electronics

Voxx Electronics Code Alarm Professional Series ca6155 User manual

Voxx Electronics PRESTIGE APS901Z User manual

Voxx Electronics

Voxx Electronics PRESTIGE APS901Z User manual

Voxx Electronics PurSuit PRO9776Z User manual

Voxx Electronics

Voxx Electronics PurSuit PRO9776Z User manual

Voxx Electronics Prestige PE1BTWZ User manual

Voxx Electronics

Voxx Electronics Prestige PE1BTWZ User manual

Popular Remote Starter manuals by other brands

Directed Electronics AutoCommand 40027 installation manual

Directed Electronics

Directed Electronics AutoCommand 40027 installation manual

Schumacher Electric BE01255 owner's manual

Schumacher Electric

Schumacher Electric BE01255 owner's manual

Schumacher FR01240 owner's manual

Schumacher

Schumacher FR01240 owner's manual

NEO TOOLS 11-997 manual

NEO TOOLS

NEO TOOLS 11-997 manual

NOCO Genius genius BOOSTMAX GB500 User guide & warranty

NOCO Genius

NOCO Genius genius BOOSTMAX GB500 User guide & warranty

DieHard 71686 owner's manual

DieHard

DieHard 71686 owner's manual

Walmart EverStart manual

Walmart

Walmart EverStart manual

Audiovox Pursuit PRO-9175FT owner's manual

Audiovox

Audiovox Pursuit PRO-9175FT owner's manual

Schumacher SL1474 user manual

Schumacher

Schumacher SL1474 user manual

AutoLoc KL400 User guide and installation manual

AutoLoc

AutoLoc KL400 User guide and installation manual

Smartech JSL-1250 Operator's manual

Smartech

Smartech JSL-1250 Operator's manual

Vector START-IT Compact Elite VEC010INV Owner's manual & warranty

Vector

Vector START-IT Compact Elite VEC010INV Owner's manual & warranty

Bahco BBCE24-10 manual

Bahco

Bahco BBCE24-10 manual

Bulldog Security RS82 Installation guide and owners guide

Bulldog Security

Bulldog Security RS82 Installation guide and owners guide

Schumacher SL1397 owner's manual

Schumacher

Schumacher SL1397 owner's manual

Chamberlain 942FP manual

Chamberlain

Chamberlain 942FP manual

idatastart TR3420BF user manual

idatastart

idatastart TR3420BF user manual

Jaycar Electronics MB3730 user manual

Jaycar Electronics

Jaycar Electronics MB3730 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.