PROSEC
Security w/Keyless Entry
Quick Installation Guide
For Complete Installation Guide and Technical
Support Please Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
Notications
Remote Programming
1 Chirp 2 Chirp
3 Chirp 4 Chirp 5 Chirp 6 Chirp
1Lock / Unlock Function 500ms 3.5sec
500ms L, DBL UL DBL L, 500ms UL DBL L, DBL UL 500ms L, 350ms UL
2 Ignition Lock OFF ON
3 Ignition Unlock OFF Unlock All
4 Exterior Illumination OFF With Arm
With Disarm With Arm & Disarm
5 Auto Relock OFF Auto Lock Only
6 Auto Arming / Locking OFF Auto Arm Only
7 Notification SoundBoth Siren
8 Horn Timing 16ms 30ms
9 Valet Override MethodValet Custom Code
10 Driver Priority Unlock OFF ON
11 Silent Choice OFF From Transmitter
12 Security ProfileAll On Doors Off
13 Door TriggerInputNegative Positive
14 Park Light / Trunk Swap OFF ON
15 Data Port Protocol ADSDBI
16 1 or 2 Wire Disarm 2 Wire 1 Wire
17 Disarm Input
80ms Dr OR Pass 120ms, UL & Light80ms, UL & Light
18 Arm 2 InputNegative Positive
19 Disarm 2 InputPositive Negative
20 Trunk Shunt InputPositive Negative
Features
Negative Output Control (NOC)
AUX Output Control
2018 Voxx Electronics. All Rights Reserved.
2 Trunk/ Hood
Factory Keyless Upgrade
Shock Sensor
The PROSEC can be used without transmitters as a Factory Keyless Alarm
Upgrade. Arm / Disarm 1 inputs will be connected to the Driver Door Lock Motor.
Arm / Disarm 2 inputs will be connected to the Passenger Door Lock Motor and / or
the Lock Switch. The polarity detection for Arm / Disarm 1 is preset to Positive (+).
The Arm / Disarm 2 input polarity can be set for Positive (+) or Negative (-). This is
found in Feature Bank 2, Features 17 & 18. Please refer the your vehicle specic
wiring information to determine the correct polarity.
Note: If this feature is supported by FLCART do not connect Arm / Disarm wires.
The Trunk Shunt input will be used if the vehicle is equipped with a factory power
trunk / hatch release. If equipped, connect the Trunk Shunt input to the Positive (+)
wire of the factory power trunk / hatch release motor. This will override the system’s
trunk and shock trigger inputs until the vehicle’s trunk / hatch is closed.
Negative output control allows any NOC to be programmed for any one of thirteen
(13) options. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Any AUX output can be congured using the AUX Control Menu. This feature is
only accessible via FlashLogic Weblink or Weblink Mobile.
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon
disarm, the system will beep 4x and ash the LED to indicate the Alarm Trigger
Zone.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the
Feature Bank programming.
1. Turn the ignition key ON/OFF.
2. Press and release the valet button 3x.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF.
This feature will not affect alarm trigger or programming.
User Programmable LED
System LED notications can be turned ON or OFF without entering Feature
Bank programming.
1. Turn the ignition key ON/OFF, ON/OFF.
2. Press and hold valet button for ve (5) seconds.
The LED will ash 1x for ON, 2x for OFF. This feature will not affect LED ash
during programming.
The shock sensor should be mounted to a solid surface in the center of the
vehicle. Once mounted the shock sensor will require adjustment.
To increase sensitivity: Turn adjustment dial clockwise.
To decrease sensitivity: Turn adjustment dial counter clockwise.
To test sensitivity, strike the vehicle with an open palm. Adjust the dial to provide
coverage to as much of the vehicle as possible.
Important Update:
The default data port protocol of this system is ADS. When ashing the FLCAN, or other integration module,
be sure to choose iDatalink 2-Way as the installation method.
This module will also support DBI. This will require programming Feature Bank 2, Feature 15 to DBI.
For Technical Support Visit www.voxxuniversity.com or Call 1-800-225-6074.
Feature Programming
Dome Delay Programming
The PROSEC Feature Banks can be programmed by using the valet button and
remote. To enter Feature Bank programming:
1. Turn the ignition key to ON.
2. Press and release valet button 3x. System will beep and ash lights 1x for
Feature Bank 1, Remote Programming.
3. Cycle ignition key OFF/ON. System will beep and ash lights 2x for Feature
Bank 2.
4. Press valet button to cycle features. LED will ash to display feature number.
5. Press lock button to cycle options. System will beep to indicate option number.
To exit Programming cycle ignition key OFF and wait ten (10) seconds. The System
will also automatically exit programming after sixty (60) seconds of no activity.
This system can be programmed to ignore the vehicle’s theater dimming dome light.
This feature will be used when connecting the door trigger input to the dome light
circuit for alarm trigger. Note: Vehicle windows should be open to prevent accidental
locking of keys in the vehicle.
Start with all doors closed and the vehicle dome light off.
1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2. Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns off the
system will set the delay time and add an additional two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for ve (5) seconds.
The system will beep 1x to indicate reset is complete.
The Feature Bank below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Please visit www.FlashLogic.com for more detail.
The PROSEC does not include an RF remote kit. The RF remote kit Includes two
(2) remotes, one (1) antenna, and one (1) cable. When added, remotes must be
programmed to the system. Remote Programming is located in Feature Bank 1. To
enter Remote Auto Programming:
1. Turn the ignition key to ON.
2. Press and release the valet button 3x. System will beep and ash the parking
lights 1x.
Press the lock button on each remote. The system will beep 1x to indicate the
remote has been programmed. If programming one (1) button remotes, press the
Start button. Only primary remote functions are auto programmed. This Includes
Lock, Unlock, and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels
to the remote. Please see the complete installation guide for manual remote
programming instruction.
Note: If programming 2-Way remotes, wait for the remote to beep before
programming additional remotes. This beep is conrmation that a 2-Way response
has been received from the main module.